Watch Movement Specification and Drawing CHRONOGRAPH. Cal. YM62A. Movement Size. Casing Diameter. Ø 27.0mm. Height. 3.7mm. Battery Life.

Similar documents
CAL. 7T62, YM62 ALARM & CHRONOGRAPH

QUARTZ YACHT TIMER WITH DATE AND ALARM

CITIZEN QUARTZ ALARM CHRONOGRAPH. Model No. AI3XXX Cal. No INSTRUCTION MANUAL CTZ-B6813

IFM6W70 CHRONOGRAPH CALENDAR INSTRUCTION MANUAL

Setting Instructions for Movement Caliber 0855

IMPORTANT Before using

COMPASS S3 S2 CALIBRATION

CAL. YM22 ANALOGUE ALARM

Operation Guide 5510

Operation Guide 3408

CAL. V071, V072 ALARM CHRONOGRAPH

CAL. W150 DIGITAL QUARTZ

Regatta-alarm I n st r u ct i o n M a n ua l

PULSAR LC DIGITAL QUARTZ

The combination watch of the analog and digital display. Solar-powered no need for battery replacement ( page 9)

OFF SAT TEMP. THU TUE 10 SET SUN -10 SET MODE AL-2 TME TMR AL-1 CHR

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

MIG-29 CHRONO RONDA 5130.D SWISS MADE WATCHES

Trotec PAC FT 2600 Portable air conditioner

DOCUMENT CREASING MACHINE

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

Navigator 3000 User's Manual

Agrifim A675CT Timer. Frequently Asked Questions

Battery-Powered Controller with Inline Valve

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Comfort Compact Controller ZG 252N

5) Do not start or stop the unit by inserting or pulling out the power plug.

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Casio Telememo 30 World Time 3 Alarm

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

User Manual. Dryer Controller M720

FD 2052 AutoSeal 12/2007 OPERATOR MANUAL FOURTH EDITION

Home and Building Control Home and Building Control Helping You Control Your World

INSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio

Operation Guide Things to check before using the watch. About This Manual. Contents. Mode Reference Guide 2015 CASIO COMPUTER CO., LTD.

Operation Guide 5259

DEHUMIDIFIER INSTRUCTION MANUAL

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

ENGINEER S MANUAL No.01

PCE_YBD60-100_IB_WM_ENG_V2_ indd 1

Induction Cooktop User's manual

PRODUCT INFORMATION IMPORTANT SAFETY INFORMATION PROGRAMMING MAINTENANCE TROUBLESHOOTING PARTS LIST WIRE DIAGRAMS

EN Manual FINAL (Ambient) NEW 4/26/99 5:03 PM Page 1 AMBIENT

RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Air Paper Jogger AJ-700 Operation Manual. Keep this manual at hand where it can be referenced at any time.

Operating Instructions

Euromixer Thermostatic Mixing Valves

IR FLAME DETECTOR RIV-601/F

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

on the use of the device and understand the dangers its use involves. User cleaning and maintenance may not be done by unsupervised

U-CLASS SPA SYSTEMS. Dealer TechBook by Gecko Alliance. Technical Specifications, Programming, Installation & User's Instructions!

Portable Room Air Conditioner and Heat Pump

Operating Manual Bathroom Balance

INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS FOR USING AND MAINTAINING INDUCTION AND CERAMIC HOT PLATES TOUCH CONTROL

PRODUCTS. Operating Manual

PAC 2600 E OPERATING MANUAL PORTABLE AIR CONDITIONER TRT-BA-PAC2600E-TC-001-EN

DYGIZONE GJD910 Lighting Controller & Enunciator

Part 2: Installation Instructions cl

BMC OPERATION AUTOMATIC & MANUAL SYSTEMS

Operators Manual. E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18

Read this manual carefully before installing and using the appliance. This will ensure optimum results and maximum safety.

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

Operating & Installation Instructions Fully Automatic Washing Machine (Domestic use)

TREO SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

POLYMIX PX-IG 2000 Operating Instructions

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Instruction manual. Please keep safe for future reference

Front Drive Elliptical Model No: E750

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

Step-by-step interpretation of 10-day electronic temperature monitoring devices for international vaccine shipments

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

What to expect from your water softener

Operating instructions

danfoss Heating Solutions 5

Safety Warnings. Work area safety. Electrical Safety. Personal Safety

REACH-IN SAFETEMP (-AAC)

Operating Your Microwave

60W Multi PIR Bulkhead

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

Model: PC600. Batch: PR3496. POWER:1000W AC V, 50/60Hz For your safety, always read the instruction book carefully before using.

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

Thermo 230 / 231 / 300 / 301 / Troubleshooting

DS1286 Watchdog Timekeeper

Portable Air-conditioner

Induction Cooktop User's manual

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

To suit Daikin FDY "F" Series. (and other models incorporating BRC1C61 Remote Controller)

Security GSM Alarm System

Transcription:

Watch Movement Specification and Drawing CHRONOGRAPH Cal. YM62A Movement Size 12 Casing Diameter Ø 27.0mm Height 3.7mm Battery Life 3 years

Date: 15/Dec./'17 Cal. YM62A Items Rev. Page Specifications 04 1 Appearance 01 2 Casing 04 3 Hand fitting 02 4 Hand setting stem 02 5 Dial-01 02 6-01 Dial-02 01 6-02 Dial-03 01 6-03 Dial-04 01 6-04 Holding ring for dial-01 03 7-01 Holding ring for dial-02 02 7-02 Attention for assembly 03 8 Attention of casing part structure 03 9 Operation-01 02 10-01 Operation-02 02 10-02

Cal. YM62A Specifications Date : Rev. : 04 30/Jan./'15 Analog Quartz 12''' Center second Chronograph and Alarm Movement 1. MOVEMENT DIMENSIONS Outside diameter Casing diameter Total height 2. TIME STANDARD Type of quartz oscillator Frequency of quartz oscillator Accuracy Operating temperature range Regulation device 27.60mm(12H-6H) 24.00mm(3H-9H) 27.00mm(12H-6H) 3.7mm (including battery) Tuning fork 32,768 Hz 20 seconds per month (on wrist) 5 to 50 Nil (Pre-adjusted) 3. INDICATOR / FUNCTIONS 3 Hands Hour / Minute / 1/5 second chronograph (Center) Small hands Alarm hour and minute (6H) / Small second (9H) Minute chronograph (12H) Calendar Instant setting device for date calendar Reset switch Power depletion warning function (BLD) (Small second hand moves at 2-second intervals) Alarm Chronograph The chronograph can measure up to 60 minutes in 1/5 second increments, capable of timing 12 hours. 4. FEATURES Jewels 0 Jewels Anti-magnetism Over 1600A/m (Direct current magnetic field) Maximum unbalance of hands Small second hand : 0.03 N m Minute chronograph / Alarm minute hand : 0.03 N m 1/5 second chronograph hand : 0.09 N m Minute hand : 0.70 N m Moment of Inertia 1/5 second chronograph hand : less than 0.2 g m² 5. BATTERY Type / Size Recommended battery Nominal voltage Battery life Driving current consumption Operation stopping voltage Silver oxide battery / 9.5mm t 2.73mm SR927W 1.55 V Approx. 3 years (2 hours chronograph and 20 seconds alarm operation per day) Approx. 0.80 A 0.9 V 6. SEPARATED PARTS (Parts code) Hand setting stem 0351584 (Standard) or 0351585 (Long) Holding ring for dial 0866650 (Standard) or 0866789 (Special) Battery SR927W Piezoelectric element 4589801 7. TEST OF ACCURACY Equipment to be used Duration of measurement Microphone to be used SEIKO quartz tester QT-99, QT2100 Greiner quartz timer-c, Witschi Q-tester 4000 10 seconds Electromagnetic detection type All specifications are subject to change without notice. P. 1

Cal. YM62A Attention for assembly Date : Rev. : 03 15/Dec./'17 1.How to replace the battery Please use the specified battery to keep the stable performance for a long time. Please install the minus part of the battery towards inside of the watch. When installing or changing the battery, it is recommended to remove two battery clamp screws first, then remove the battery clamp not to damage the movement parts. If you install the battery without removing the battery clamp, please install the battery from [ ] direction as illustrated below Fig.[1]. Install the battery under the circuit cover as illustrated below Fig.[1] and Fig.[2]. System-reset is not required. After installing the battery, set the current time and then set the alarm time same as current time to let the alarm work correctly, set the 1/5 second chronograph hand and minute chronograph hand at "0" position. Battery clamp Circuit cover A Battery Fig.[1] Fig.[2] A section 2.How to remove the stem When removing the stem, pull out the crown at 1st click position and then remove the stem while pressing the hollow portion of setting lever by tweezers. (Refer to the Fig.[3].) Fig.[3] Crown pulled out at 1st click 3.How to set the hands Each hand moves at step interval. Set the each hand at correct position according to the scale on the dial in order not to make a mistake in reading time. Do not turn the hand forcibly. 4.How to remove the hands When removing the hands, use exclusive fork-shaped tools. Do not remove the dial under the condition that any hands are set. 5.How to test the accuracy When measuring the time accuracy, use specified Quartz Tester and change the gate time in 10 seconds. P.8

Cal. YM62A Attention of casing part structure Date : Rev. : 03 30/Jan./'15 1.Minute hand The center wheel have a safety stopper structure to prevent the minute hand from being pressed too much. However pay attention to the contact between hour hand and minute hand. 2.Holding ring for dial Use the specified holding ring for dial to prevent rotation of the movement inside of the case in order to stabilize the button operation. Refer to the [Holding ring for dial] page instruction as to the shape and tolerance. 3.Case Use the metal case to prevent from the movement mal-function by static electricity. 4.Hour wheel When set and remove the hour hand repeatedly, it may reduce the hand fixing torque because the hour wheel is made by plastic. To ensure the enough fixing torque, it isn't recommended to re-assemble the hour hand more than five times. 5.Piezoelectric element Stick piezoelectric element to the center of case back. Case back Piezoelectric element : 18mm Piezoelectric element must be stuck to case back by thermoplastic adhesive. Thermoplastic adhesive is already printed to the surface of piezoelectric element. Heating temperature and time to stick piezoelectric element is shown in the following table. Material of case back Heating temperature Heating time Stainless 250 5 seconds Titanium 250 6 seconds Check piezoelectric element is definitely stuck to case back after heating. Sticking position The amount of the misalignment between the center of case back and piezoelectric element : 0.35mm and less If the sticking position of piezoelectric element is drastically misaligned or if the electrical continuity is bad, no sound may occur. P.9

Cal. YM62A Operation-01 Date : Rev. : 02 31/Jul./'14 1/5 second chronograph hand Minute chronograph hand Hour hand Minute hand 2H button Small second hand 0 1 2 Crown 4H button Alarm hour hand Alarm minute hand Crown position 0 click 1st click 2nd click Crown Free Turn clockwise for date change Time setting 2H button Chronograph Start/Stop Restart Free (No effect) [*1] 4H button Chronograph Reset Split Split release Alarm time setting (at 6H small circle) [*1] [*1] How to set the "0" position Pull crown out to the 2nd click position. Press 4H button repeatedly to set alarm hands to the time the main time hands indicate. Press 2H button for 2 seconds. Minute chronograph hand turns a full round and can now be set to correct "0" position. Press 4H button repeatedly to set it to "0" position. Press 2H button for 2 seconds. 1/5 second chronograph hand turns a full round and can now be set to correct "0" position. Press 4H button repeatedly to set it to "0" position. Press 2H button for 2 seconds here will allow you to resume the procedure again as indicated by the arrow if necessary. Push crown back to normal position. P.10-01

Cal. YM62A Operation-02 Date : Rev. : 02 31/Jul./'14 Chronograph function The chronograph can measure up to 60 minutes in 1/5 second increments, capable of timing 12 hours. When the measurement reaches 12 hours, the chronograph automatically stops counting. Standard measurement 2H button 2H button 4H button Start Stop Reset Accumulated elapsed time measurement 2H button 2H button 2H button 2H button 4H button Start Stop Restart Stop Reset Split time measurement Restart and stop of the chronograph can be repeated by pressing 2H button. 2H button 4H button 4H button 2H button 4H button Start Split Split release Stop Reset Measurement and release of sprit time can be repeated by pressing 4H button. Alarm function The alarm can be set to ring only once at a designated time within the coming 12 hours. The alarm time can be set in one minute increments. Set the alarm time Crown 4H button Crown Pull out 1st. position Set the alarn time [*1] Push back Normal position [*1] Press 4H button repeatedly to set the alarm hands to the desired alarm time. The alarm hands move quickly when the 4H button is kept pressed. They stop when the hands reach to the current time. Release and press the 4H button, the alarm hands will start moving again. Stop the alarm At the designated time the alarm rings for 20 seconds, and it is automatically disengaged as it stops. It is possible to stop ringing manually when pressing any button. While the alarm is ringing, no chronograph operation can be made. Cancel the alarm (when alarm time is set) Crown 4H button Crown Pull out 1st. position Cancel the alarm [*2] Push back Normal position [*2] Press and hold 4H button until alarm hands stop and indicate the current time. P.10-02