Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Similar documents
CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Inverter Wall Mounted

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

Inverter Wall Mounted

Inverter Wall Mounted

PCR0709A. Options. Indoor unit

Split Type Air Conditioners

Split Type Air Conditioners

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

The Comfort and Luxury You Deserve

FAQ. Wall Mount Heat Pump or Cooling Only

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

Inverter Wall Mounted Series

LV Series. SEER 20+ Wall Mount Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

for your home FTYN-GX FT(Y)N-F

Daikin air conditioners for your home

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

LV Series. SEER 15+ Concealed Built in Heat Pump

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

About Daikin: WARNINGS:

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

FBQ. DC Duct Heat Pump or Cooling Only

w w w. d a i k i n. e u ATXS-E

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Daikin air conditioners for your home

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

PLXSID1605. Warning HEAD OFFICE :

The Comfort and Luxury You Deserve

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Lineup of DC Inverter Air Conditioners with R-32 Refrigerant

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

The Comfort and Luxury You Deserve

Daikin air conditioners for your home

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

DESIGN & TECHNICAL MANUAL

BENEFIT FROM LOWER FUEL COSTS.

The World s No.1 Heat Pump Company HEATING AND COOLING SOLUTIONS SUPER MULTI NX MULTI-SPLIT AIR CONDITIONERS DC INVERTER CONTROL

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Daikin air conditioners for your home, shops, restaurants and offices

DESIGN & TECHNICAL MANUAL

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Product Brochure 2017

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

Hi - Wall Split Systems 12K - 18K - 24K

SPLIT SYSTEM HEATING AND COOLING SOLUTIONS FROM DAIKIN. Energy efficient heating and cooling solutions for your home

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

. Creating Maximum Comfort

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

DESIGN & TECHNICAL MANUAL

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DESIGN & TECHNICAL MANUAL

AIR CONDITIONING REVERSE-CYCLE INVERTER

AIR CONDITIONERS, HEATING & COOLING for your home

Wall Mounted Mini Split Heat Pump Air Conditioner

DESIGN & TECHNICAL MANUAL

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Service Manual. Inverter Pair. Floor / Ceiling Suspended Dual Type B-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

for your home FTXS-G WALL MOUNTED UNIT

DAIKIN S URURU SARARA

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

DESIGN & TECHNICAL MANUAL

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

RC-0219-A. Single-Split Non Inverter Series

Using the Remote Control Unit

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

G Series Inverter Split Systems

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

HEAT PUMPS BY DAIKIN. Energy efficient heating and cooling solutions for your home

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioners Heating & Cooling

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

SiBE041525F. Service Manual. Inverter Pair Wall Mounted Type FTX/ATX-K Series. [Applicable Models] Inverter Pair: Heat Pump

Transcription:

PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the user s manual carefully before using this product. The user s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Split Type Air Conditioners FTNE-M Series Only [50 Hz] Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Specifications, designs and other content appearing in this brochure are current as of September 2015 but subject to change without notice. c All rights reserved PC

Personalise Your Cool Daikin s sophisticated airflow control and low sound pressure levels surround you with a cloud of quiet comfort. Choosing the right model is easy, with a full lineup of 4 models from 2.5 to 6.0 available. These stylish, compact units look just as cool as they feel. FTNE-M series using R-410A is newly launched. 2.5 and 3.5 Class 5.0 and 6.0 Class FTNE25MV18 / RNE25MV1 2.62 9,000 FTNE50MV18 / RNE50MV1 5.20 17,750 FTNE35MV18 / RNE35MV1 FTNE60MV18 / RNE60MV1 FTNE25/35M 3.35 11,450 FTNE50/60M 6.4 21,800 RNE25M RNE35M RNE50/60M 1 2

Comfortable Airflow Control Power-Airflow Dual Flaps Power-Airflow Dual Flaps flatten out during cooling operation to deliver air to every part of a room. Choosing the low angle sends air right to the corners, while choosing the high angle spreads air around the centre. Vertical Auto-Swing (up and down) Vertical Auto-Swing (up and down) automatically moves the flaps up and down to distribute air across a room. When the air conditioner is turned off, the flaps shut automatically so that dust can not enter. When you choose the low angle, cool air slides off to reach the corners of the room. Power Chill Operation Wide-Angle Louvers New Powerful Operation Power Chill Operation and New Powerful Operation boost airflow to maximum volume for a 20-minute period. This is convenient when you want to quickly adjust the indoor temperature to the set temperature. After this, the unit automatically returns to its previous settings. Power Chill Operation is available for 2.5 and 3.5 models and New Powerful Operation for 5.0 and 6.0 models. 20 minutes Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. The louvers can be adjusted to deliver cool air to the corners of a room by hand. The louvers cover even a spacious room. The angles of the louvers can be adjusted according to where people are in the room. If the indoor unit is not positioned in the centre of the wall, the louvers can also be adjusted to the left or right. 3 4

Energy Savings and Quiet Operation COP of or More The 2.5 to 6.0 models provide a high COP of or more. An air conditioner s COP (Coefficient of Performance) indicates how efficiently the unit uses energy. A higher COP means greater energy efficiency. It also means lower electricity consumption, so you save money. COP = (W) Power consumption (W) FTNE25M 3.20 FTNE35M FTNE50M FTNE60M Night Set Mode Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling for a pleasant sleep. Sixty minutes after the Off timer button is pressed, the room temperature is raised by 0.5 C. Set temp. before Off timer begins to operate Time 60 minutes Off timer turns on +0.5 C Off timer stops air conditioner operation: Room temperature is raised by 0.5 C after 60 minutes. Quiet Operation The key benefit of split type air conditioners is their quiet operation. This is made possible by the separate indoor and outdoor units. The FTNE25M offers a low sound pressure level of 28 db (A) for indoor unit operation and 50 db (A) for outdoor unit operation. Indoor Unit On/Off Switch This switch provides convenient manual starting of the indoor unit in the event the wireless remote controller is misplaced or its batteries are not charged. 28 db (A) Is So Quiet You Can Even Hear Whispers 20 28 30 40 50 50 (db (A)) FTNE50/60M Indoor Unit On/Off Switch Rustling of leaves Pendulum of a wall clock Library Normal office Based on Examples of Sound Pressure Levels, Ministry of the Environment, Japan, November 12, 2002 5 6

Worry-Free Design Functions Function List Anticorrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are covered with a thin acrylic resin layer to enhance their resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets. Cross section of anticorrosion-treated fin Hydrophilic film Aluminium Corrosion-resistant acrylic resin Comfortable Airflow Power-Airflow Dual Flaps The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. See page 4 Wide-Angle Louvers The smoothly curved Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room. See page 4 Vertical Auto-Swing (up and down) This function automatically moves the flaps up and down to distribute air across a room. See page 4 Comfort Control Timers Programme Dry Function The microprocessor works to rid the room of humidity while maintaining the most consistent temperature possible. It automatically controls the temperature and airflow rate. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. Count Up-Down On/Off Timer This timer function allows an off time (up to 9 hours later) and on time (up to 12 hours later) to be set simply by pressing the Timer On/Off button on the remote controller. Indoor Unit Functions Comfortable Airflow Comfort Control Power-Airflow Dual Flaps Wide-Angle Louvers Vertical Auto-Swing (up and down) Programme Dry Function Auto Fan Speed s FTNE 25/35M FTNE 50/60M Heat exchanger fin Long Piping Length for Flexible Unit Placement The FTNE35/50/60M supports a piping length of up to 20 metres to give flexibility during unit installation. This allows the outdoor unit to be placed on a balcony or where it can not be seen. s can also be installed where they do not compromise the decor of a room. Max. level difference 15 m Max. piping length Max. piping length 20 m Max. level difference FTNE25M 15 m 12 m FTNE35/50/60M 20 m 15 m FTNE60M Lifestyle Convenience Cleanliness Power Chill Operation Power Chill Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings. See page 3 New Powerful Operation New Powerful Operation boosts airflow to maximum volume for a 20-minute period. After this, the unit automatically returns to its previous settings. See page 3 Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. See page 6 Wipe-Clean Flat Panel The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning. Worry Free 24 Hour On/Off Timer This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10-minute steps by pressing the On/Off timer button on the wireless remote controller. The On timer and Off timer can be used in combination. Night Set Mode Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5 C. See page 6 Auto-Restart after Power Failure The air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure. Self-Diagnosis with Digital Display Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance. Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion. See page 7 Lifestyle Convenience Cleanliness Timers Worry Free Outdoor Unit Functions Power Chill Operation New Powerful Operation Indoor Unit On/Off Switch Wipe-Clean Flat Panel Count Up-Down On/Off Timer 24 Hour On/Off Timer Night Set Mode Auto-Restart after Power Failure Self-Diagnosis with Digital Display s RNE 25/35/50/60M Worry Free Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins 7 8

Controllers Specifications Wireless Remote Controller for FTNE25/35M Power Chill Operation Selects mode: cooling, dry, fan-only operation Cancels On/Off Timer Count Up-Down Off Timer and Night Set Mode On/Off switch Sets room temperature Selects fan speed Vertical Auto-Swing (up and down) Count Up-Down On Timer name Power supply Running current Power consumption COP Front panel colour Airflow rate Fan speed Sound pressure level Dimensions Machine weight Casing colour Compressor Refrigerant Sound pressure level Dimensions Machine weight Operation range Piping connection Max. piping length Max. level difference H H/L H x W x D Type Motor output Type Charge H x W x D Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) mm kg W kg db (A) mm kg CDB mm m FTNE25MV18 RNE25MV1 2.62 9,000 FTNE35MV18 RNE35MV1 3.35 11,450 FTNE50MV18 RNE50MV1 5.20 17,750 FTNE60MV18 RNE60MV1 6.40 21,800 1 phase, 220 V, 50 Hz 3.6 819 3.20 FTNE25MV18 5.0 1,063 FTNE35MV18 8.0 1,650 FTNE50MV18 9.3 2,032 FTNE60MV18 Almond white White 8.1 (286) 18.5 (653) 5 steps and automatic 37/28 39/33 48/35 48/36 273 x 784 x 195 290 x 1,050 x 238 8 12 RNE25MV1 RNE35MV1 RNE50MV1 RNE60MV1 Ivory white Hermetically sealed rotary type 760 900 1,300 1,959 R-410A 0.67 0.88 0.90 50 51 54 53 418 x 695 x 244 550 x 658 x 275 595 x 845 x 300 25 32 36 40 19.4 to 46 6.4 9.5 12.7 15.9 18.0 15 12 20 15 Note: The holder for the wireless remote controller is not available. Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5 m. 2. Sound pressure levels are measured in an anechoic chamber based on condition 1. above. These values are normally somewhat higher during actual operation as a result of ambient conditions. Wireless Remote Controller for FTNE50/60M Options No. 1 Item Remote controller loss prevention with chain FTNE25/35/50/60M KKF917A4 New Powerful Operation Selects fan speed Selects mode: cooling, dry, fan-only operation Sets room temperature On/Off switch Vertical Auto-Swing (up and down) Cancels On/Off Timer Remote controller loss prevention with chain KKF917A4 24-Hour On Timer 24-Hour Off Timer and Night Set Mode Sets clock Sets timer No. 1 Drain plug Item Note: *1. One set includes five pieces for five units. * 1 RNE25/35/50/60M KKP937A4 Drain plug KKP937A4 9 10