PARALLEL USE OF SEVIRI LSA SAF FRP AND MPEF FIR PRODUCTS FOR FIRE DETECTION AND MONITORING

Similar documents
A temporal active fire detection algorithm applied to geostationary satellite observations

Supplement of LSA SAF Meteosat FRP products Part 1: Algorithms, product contents, and analysis

The operational MSG SEVIRI fire radiative power products generated at the Land-SAF

Global Biomass Burning Emissions from a Constellation of Geostationary Satellites for Global Model Forecast Applications

SEVIRI/MSG sensor early fire detection performances assessment

University of Puerto Rico at Mayagüez Direct Broadcast Polar Orbiter Workshop

Physical concepts. Remote sensing of fires and vegetation. Applications of SEVIRI channels.

Recent Developments and Prospects for Innovative Remote Sensing of High-Temperature Events and Vegetation Fire Impacts

P1.9 CHARACTERIZING AND UNDERSTANDING THE DIFFERENCES BETWEEN GOES WF_ABBA AND MODIS FIRE PRODUCTS AND IMPLICATIONS FOR DATA ASSIMILATION

[Some] Updates on Research into Fire Radiative Power & Energy

Ivan Csiszar, Martin Wooster

GOES-R AWG Land Team: Fire Detection and Characterization

Review of MTG FDHSI Mission Requirements Regarding Fire Applications

GOFC/GOLD Fire IT Strategic Planning. Day 1 - Break Out Group Discussion

Overview of the WF_ABBA Global Geostationary Fire Monitoring Program: Current Implementation and Future Plans

Elaine M. Prins* NOAA/NESDIS, Office of Research and Applications, Advanced Satellite Products Branch (ASPB) Madison, WI

DETECTION AND MONITORING OF ACTIVE FIRES USING REMOTE SENSING TECHNIQUES

Interim evaluation of the New IR Sensor Technology (NIRST) as a wildfire monitoring tool

Google-Earth use as a monitoring tool for EUMETSAT s active fire product

Use of new spatially refined satellite remote sensing fire detection data in support of advanced wildfire mapping and modeling

FIRE DETECTION AND MONITORING USING AVHRRA AND MSG SYSTEMS. Version Tuesday, 1.0, 1530 November Slide: 1

Advanced Fire Information System

Detection and analysis of high-temperature events in the BIRD mission

SAF for Land Surface Analysis (LSA SAF)

FIRE DETECTION AND PARAMETERIZATION WITH MSG-SEVIRI SENSOR

There are various resources and toolkits available to perform this task.

Session 2: LSA-SAF evapotranspiration: files, format and applications

Development of a Canadian Wildland Fire Monitoring Sensor (CWFMS)

BEYOND for atmospheric hazards monitoring and forecasting

Analysing Threshold Value in Fire Detection Algorithm Using MODIS Data

S-NPP/VIIRS and Landsat-8/OLI Global Active Fire Data Sets

DEMONSTRATION OF A SEMI-OPERATIONAL FIRE RECOGNITION SERVICE USING BIRD MICRO- SATELLITE - DEMOBIRD

Fire Detection and Monitoring

Verification and Validation of OOV-TET1 Multispectral Camera Observations within the FireBIRD Project

Using VIIRS Direct Readout Capabilities for the Improvement of Mexico's Wild Fire Alert System

Long-term Inventory of Fire Burned Areas and Emissions of North America s Boreal and Temperate Forests

Global fire hotspots detected by NASA satellite to help United Nations

VIIRS FIRE PRODUCTS UPDATE

Land SAF LSA-SAF Evapotranspiration (ET) Product

Fire-Implementation Team (Fire-IT) Update and Future Steps

Methods of detecting burnt area and estimating emissions Dr. Kevin Tansey

Evaluation of remote sensing-based active fire datasets in Indonesia

Results on verification and validation of OOV-TET1 multispectral camera observations within the FireBIRD project

Rapid Prototyping of NASA Next Generation Sensors for the SERVIR System of Fire Detection in Mesoamerica

Daytime Fire Detection Using Airborne Hyperspectral Data Philip E. Dennison 1 and Dar A. Roberts 2. University of Utah, Salt Lake City, UT 84112, USA

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

Band Selection & Algorithm Development for Remote Sensing of Wildland Fires

I. INTRODUCTION. Index Terms Fires, satellites.

Wildfire Mapping Using FireBIRD Data

Evaluating the Potential for Green Roof Retrofit in Urban Fabric

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

A Review of AVHRR-based Active Fire Detection Algorithms: Principles, Limitations, and Recommendations

Battery Performance Alert

Validating the TET-1 satellite sensing system in detecting and characterizing active fire hotspots

DISASTER LANDSCAPE ATTRIBUTION

Validation of MODIS Active Fire Detection Products Derived from Two Algorithms


CROWD-SOURCED REMOTE ASSESSMENTS OF REGIONAL-SCALE POST-DISASTER DAMAGE

Security Management System - Configuring Video Analytics

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

NEAR REAL TIME DETECTION OF BURNED SCAR AREA USING LANDSAT-8 IMAGERIES

Smart Fire Prevention

16.10 Johannes Kaiser HALO Proposal

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas

Space-borne high resolution fire remote sensing in Benin, West Africa

remote sensing ISSN

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

Failure Modes, Effects and Diagnostic Analysis

[ [ ADMIN PANEL USER GUIDE

Krasimira Petkova, Alexander Tashev University of Forestry - Sofia INTRODUCTION

Session Ten Achieving Compliance in Hardware Fault Tolerance

Fire Mapping Chapter. Working Paper

Brine Generation Study

Fire Information for Resource Management System (FIRMS)

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Fire Detection Using Image Processing

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Forest fire detection based on MODIS satellite imagery, and Comparison of NOAA satellite imagery with fire fighters' information

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

GOFC-GOLD Fire An Overview

A study of radiant cooling for a room with daytime application in tropical climate

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

This paper will discuss the leak detection technologies that have been adapted to detect thefts and secure accurate tapping point locations.

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

THE NORTHSTAR SYSTEM: A NEW ERA IN EARTH OBSERVATION

Radiation Environment on ISS in April 2013 According the Data from Liulin-5 Particle Telescope

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

THE ENVIRONMENTAL PROTECTION IN THE URBANISTICPLANNING AND LAND DEVELOPMENT IN EUROPEAN UNION LAW

INVESTIGATION OF THE DECREASE OF SOIL ORGANIC MATTER AND SOIL POLLUTION BY HEAVY METALS IN THE AREAS INTENSIVELY USED FOR MILITARY ACTIVITIES

September 11, 2012 Ministry of Economy, Trade and Industry

GOES-R ABI Emissive IR Bands Radiometric Performance Monitoring and Trending

Estimating Fire Properties by Remote Sensing 1.

Heat pump supplemental heating system for motor vehicles

Strategic Research Agenda for. High-Altitude Aircraft and Airship. Remote Sensing Applications

ALBERTA FOREST PROTECTION THERMAL INFRARED PROGRAM

Sub-Critical Operation of the CO2 Expander/ Compressor

Transcription:

PARALLEL USE OF SEVIRI LSA SAF FRP AND MPEF FIR PRODUCTS FOR FIRE DETECTION AND MONITORING C. G. Georgiev, J. S. Stoyanova National Institute of Meteorology and Hydrology, Bulgarian Academy of Sciences Tsarigradsko chaussee 66, 1784 Sofia, Bulgaria Abstract The paper is focused on operational application of LSA SAF FRP product as additional data to the MPEF FIR product for fire detection over South-eastern Europe. Detections by NASA TAP MODIS product are used as a reference for assessing the efficiency of the two algorithms using MSG SEVIRI measurements as input data. The performance of the MPEF FIR and LSA SAF FRP products over Bulgaria in July/August 2012 (an year of moderate fire activity) and August 2013 (an year of very low fire activity) is studied considering 40 forest fires (reported by State Forest Agency of Bulgaria). The actual differences or mismatches are studied in order to analyse the following products capabilities. - First detection by a product including early warnings (before fire detection by ground observations as reported in the National Fire Data Base of Bulgaria). - Which of the two algorithms using MSG SEVIRI measurements as input data was able to better detect the signals from the fires during the whole duration of the event (as reported in the National Fire Data Base). - Cases of small fires not detected by one of the SEVIRI fire products and detected by the other one. INTRODUCTION The aim of this study is to evaluate the efficiency of the fire detection algorithms based on data from Meteosat Second Generation (MSG) satellites. Products from two kinds of satellite systems and algorithms are available via the EUMETSAT's primary dissemination mechanism EUMETCast: Two products based on MSG SEVIRI instrument: FIR product of Meteosat Products Extraction Facilities (MPEF) of EUMETSAT for thermal anomalies detection by MSG data. Fire Radiative Power (FRP) product of Land Surface Analysis (LSA) Satellite Application Facilities (SAF) Programme of EUMETSAT. Thermal Anomalies Product (TAP) at the land surface of National Aeronautics and Space Administration (NASA) based on MODIS instrument on Aqua/Terra satellites. The MPEF FIR product has been operationally used since 2007 at NIMH of Bulgaria and, in parallel, the performance of its three versions has been evaluated (Stoyanova, et al., 2008; Stoyanova and Georgiev, 2010). In this paper the LSA SAF FRP product, available from 2008 in its five versions up to 2009 (LSA SAF, 2010) is used as an additional tool for fire detection (Wooster et al., 2003; Govaerts et al., 2010). The FRP product Version I/2010 has been used in the environment of NIMH of Bulgaria since 2012. Attention is given to some limitations of using satellite fire products regarding the dissemination file formats as well as specific synoptic situations, which are favourable for development of both fires and cloudiness aiming to avoid misunderstanding when assessing the performance of fire detection algorithms.

FIRE DETECTION ALGORITHMS AND DATA SET The so-called Fire Thermal Anomaly (FTA) algorithm (Giglio et al., 2003) is used for generation of the MODIS TAP as well as the LSA SAF FRP products. The first stage of the FTA algorithm work is the detection of all "fire pixels" within the image that are believed to contain actively burning fires. For Fire Detection the algorithm works mainly on statistics derived from the 3.9 µm and 10.8 µm brightness temperatures, and their differences. On a first pass a series of absolute thresholds are used with these data to detect "potential" fire pixels, which are then further assessed as "true" or "false" fire detections based on a series of further "contextual" tests whose thresholds are adjusted based on statistics derived from the immediately neighbouring non-fire "background" pixels. A cloud mask is used in order to eliminate specular reflections and cloud edges that can present a similar signature to fires under certain daytime conditions (Giglio et al., 2003). The FRP product is operationally generated by data from MSG2 Full scanning, sub-satellite point location 0.0 longitude, repeat cycle every 15 min, resolution 3 km at the sub-satellite point and 5-6 km over South Eastern (SE) Europe. The MPEF FIR SEVIRI product is operationally generated by EUMETSAT in two modes: MSG2 Full scanning, sub-satellite point location 0.0 longitude, repeat cycle every 15 min, resolution ~ 3 km at the sub-satellite point and 5-6 km over SE Europe. MSG2 Rapid scanning, sub-satellite point location 9.5 E longitude, repeat cycle every 5 min, resolution ~ 3 km at the sub-satellite point and ~5 km over SE Europe. The MPEF fire detection algorithm is based on a simple threshold test technique, using SEVIRI channels 4 (3.9 µm) and 9 (10.8 µm), considering a set of parameters: Brightness temperature IR3.9; Standard Deviation IR3.9); Standard Deviation IR10.8); Standard Deviation difference (StdDev3.9 StdDev10.8); Brightness temperature difference (IR3.9-IR10.8). The algorithm is applied for all land surface pixels, excluding desert/bare soil surface pixels and coastal pixels. The algorithm does not need any cloud masking as an input. Instead of cloud mask, it uses SEVIRI channel 1 (0.6 µm) to eliminate (low) clouds with a high reflectance. The algorithm does not perform "contextual" tests. The study is performed on the base of 31 forest fires in the summer of 2012 and 9 fires in August 2013 reported in the National Data Base, which is maintained by the State Forest Agency (SFA) of Bulgaria. The National Fire Data Base consists of information about various fire characteristics: The village, in which region a fire is located, fire evolution, ignition cause, affected area (total, under/at the forest canopy, herbs & grass), fire rescue operations, etc. Detections by MODIS TAP product are used as a reference for assessing the efficiency of the two SEVIRI algorithms. The performance of the MPEF FIR and LSA SAF FRP products is studied regarding the following products capabilities. First detection by a product, including early warnings (before fire detection by ground observations as reported in the National Fire Data Base). Which of the two algorithms using SEVIRI measurements as input data was able to better detect the signals from the fires during the whole duration of the event (as reported in the National Fire Data Base). Cases of small fires not detected by one of the SEVIRI algorithms and detected by the other one. Data from Thermal Anomalies Product based on measurements of MODIS instrument on polar orbiting satellites with repеat cycle four ooverpasses daily and resolution 1 km at the sub-satellite point, including ~ 1 km over SEE are used as a reference. DIFFERENCES AND MISMATCHES BETWEEN THE LSA SAF FRP AND MPEF FIR: CASE STUDY EXAMPLES OF FOREST FIRES IN 2012-2013 Tables 1 and 2 show results for a set of forest fires registered at the SFA Data Base. The fire cases are chosen to cover various fire characteristics (regarding size of area affected, duration and diurnal

evolution, type of fuel burned). A comparison of the fire detection efficiency of the two MSG SEVIRI products are presented in Table 1. Table 1. Actual differences between the performance of SEVIRI LSA SAF FRP and MPEF FIR products Product/Instrument Detection firstly by this product Total number of first fire detections Early Warning, before ground observations Better monitoring fire evolution by this product Number of nights with detections of the fire with this product Miss to detect by this product Total Partially fires cloudy failed to cases detect July-August 2012: moderate fire activity over Bulgaria Total number of cases 31 31 31 31 31 LSA SAF FRP / SEVIRI 16 6 9 3 9 2 (of 9) MPEF FIR / SEVIRI 9 2 9 3 16 5 (of 16) August 2013: very low fire activity over Bulgaria Total number of cases 9 9 9 9 9 LSA SAF FRP / SEVIRI 2 0 2 1 4 0 of 4 MPEF FIR / SEVIRI 6 0 2 1 0 0 In the year of moderate fire activity 2012, the results show that LSA SAF FRP is more efficient than MPEF FIR in detection of small fires as well as more efficient in providing early warnings. In the year of very low fire activity 2013, the results are opposite: FIR is more efficient than FRP in detection of small fires as well as more efficient in providing early warnings. FRP or FIR are efficient at a different extend (depending on specific conditions) in detecting signals during the whole duration of the fire events for the two years studied. Table 2 shows the performance of MODIS TAP algorithm regarding the fire detections by SEVIRI LSA SAF FRP and MPEF FIR products. Table 2. Performance of MODIS TAP product for July-August 2012. Performance of MODIS TAP Number Total number of cases Fires failed to detect by MODIS TAP algorithm 12 31 (all studied) MODIS faled to detect, while FRP and/or FIR detected 10 MODIS TAP detections when FRP and FIR failed to detect fire 4 6 (no detected by both FPR and FIR) MODIS TAP detections prior to FRP and/or FIR fire detection 2 15 detected by both FPR and FIR) For 2012, an year of moderate fire activity, among the fires detected by any of the three satellite products, the omissions by MODIS TAP are twice more than the omissions by the three MSG SEVIRI products considered all together. These are usually MODIS TAP omissions of small forest fires, because the high frequency observations by geostationary satellites (especially for the MSG Rapid Scan service) is critical for a remote sensing product to efficiently catch such a fire in a short period of its development. MODIS TAP managed to detect 2 fires (13 %) earlier than both SEVIRI products when the fire ignition time is very close before an Aqua/Terra satellites overpass allowing availability of relevant MODIS data. Large forest fires are usually detected by all products, and each of the products can show various abilities to follow the evolution of high energy and long lasting fire events. Table 3. Burned area (ha) characteristics of the fires in Fig. 1. Figure Date Location Total Forest Under canopy At Canopy Grass, herbs 1a 26/08/2012 42.267 N 27.067 E 8000.0 954.7 844.7 110.0 85.6 1b 22-30/08/2013 41.91 N, 26.4 E 366.4 366.4 318.5 47.9 124.9

Figure 1 shows the detections by the different products during the development of two large fire cases detected by ground observations on 26/08/2012 at 1100 UTC in the area of village Valtchanovo (42.267 N, 27.067 E) and Studena (41.91 N, 26.4 E) with two fire development stages: 22/08/2013 1050UTC - 26/08/2013; 26/08/2013 1645 UTC - 30/08/2013, along with the fire energy release at each detected pixel measured by the FRP product. The burned area characteristics are presented in Table. 3. (a) Fig. 1. Fire detections by different fire products: MSG 0º MPEF FIR (green dot symbols), MSG 9.5º MPEF RSS FIR (yellow dot symbols), LSA SAF FRP (blue dot symbols) and TAP MODIS (red dot symbols) for the two fires described in Table 3. For the first fire in Fig. 1a, there are successful fire detections by all products at the beginning of fire development and high energy release (up to 900 MW) as measured by FRP product. For SE Europe, the Rapid Scan FIR product from 9.5 E, because of its higher spatial resolution at the region, provides more efficient fire monitoring than FRP, which is based on Full Scanning from 0. During the first stage of the second fire (Fig. 1b), starting with burning, which produces high Fire Radiative Energy (up to 220 MW), there are fire detections by all products at the beginning of fire development. However, TAP and FRP (derived through FTA algorithm using MODIS and SEVIRI data accordingly) show better fire monitoring than the MPEF FIR product at the later stage of fire development of low radiative energy (lower that 60 MW) release. LIMITATIONS Cloudiness in Fire Weather situations: Failure detection by Satellite Products A significant fire remote sensing constrain is the presence of cloudiness in fire weather situations. The algorithms could not detect existing fires due to elimination of cloudy pixels or assuming some detections in partially cloudy pixels as "false" fire detections based on "contextual" tests. False alarms are also possible in cases of sun glint reflection from undetected small clouds. Specific synoptic situations, which are favourable for development of both fires and cloudiness have been identified to help avoid misunderstanding when assessing the performance of fire detection algorithms. This section presents several instances of differences/mismatches between SEVIRI FIR, SEVIRI FRP and MODIS TAP products in detection of actual fires reported in the National Data Base of SFA of Bulgaria in such synoptic conditions. Shallow convection during the summer produces partial cloudiness in the MSG satellite view (Fig. 2d). In some cases of partial cloudiness the SEVIRI fire products may be able to detect a fire in single slots due to its higher frequency of MSG observations, while TAP MODIS does not detect the fire because of cloudy conditions at the moment of satellite overpassing the fire location. Fig. 2 shows such an example of actual fire on 4 August 2012, at 42.66N 25.95E detected in single pixels by FRP and FIR RSS and no detected by TAP MODIS.

(a) (c) (d) Fig 2. A situation of shallow convection on 4 August 2012 in which TAP MODIS failed to detect a fire detected by (a) LSA SAF FRP at 0800 UTC and MPEF FIR RSS at 1125 UTC. (c) MPEF Cloud Mask product at 0800 UTC, (d) MSG HRV channel image at 1100 UTC. In other partially cloudy cases (Fig. 3b), fires are detected by MODIS because of higher spatial resolution while the SEVIRI algorithms classify the corresponding pixel as cloudy and do not detect the fire. Such an example of a fire on 19 August 2012 at location 42.3N 27.23E is presented in Fig. 3. There is only detection by TAP MODIS and no detections by FRP and FIR products based on MSG SEVIRI data. (a) Fig 3. A situation of shallow convection on 22 August 2012 in which MPEF FIR and LSA SAF FRP failed to detect a fire detected by (a) TAP MODIS at 1135 UTC. MSG HRV channel image at 1200 UTC.

In other cases, partially cloudiness can be produced my deep convection (Fig. 4b) and a fires can be detected by MODIS because of higher spatial resolution while the SEVIRI algorithms classify the corresponding pixel as cloudy and do not detect the fire. As an example, the fire case on 22 August 2012 at location 42.3N 23.767E is presented on Fig. 4. In this case of deep convection TAP MODIS product was able to detect the fire at a cloud free area near the convective development, while FRP and FIR algorithms did not detect the fire in this cloudy scene. (a) Fig 4. A situation of deep convection on 22 August 2012 in which MPEF FIR and LSA SAF FRP failed to detect a fire detected by (a) TAP MODIS at 1205 UTC. MSG HRV channel image at 1200 UTC. Invalid EUMETCast files of MPEF FIR in CAP format: Mismatches between the MPEF FIR files in GRIB2 and CAP format In 2011, EUMETSAT changed the file format for dissemination of fire pixel coordinates from ASCII (American Standard Code for Information Interchange) to CAP (Common Alert Protocol). After this change, some MPER FIR files, disseminated in CAP format do not consist fire pixels, which are present in the corresponding GRIB2 files, received via EUMETCast. Many of these invalid CAPformat files from the Full Scan service have been received on EUMETCast DATA CHENNEL-3. The invalid CAP format files can cause fire misdetection in the first stage of fire development. Fig. 5 shows the MSG 0º MPEF FIR fire pixels indicated in the GRIB2 file (green dot symbols) and in the CAP format file (magenta triangular symbols). (a) Fig. 5. MSG 0º MPEF FIR fire pixels indicated in the GRIB2 file (green dot symbols) and in the corresponding CAP format file (magenta triangular symbols) along with the detections by other fire products (LSA SAF FRP in blue dot symbols, MSG 9.5º MPEF RSS FIR in yellow dot symbols and TAP MODIS in red dot symbols). (a) Fire on 22 August 2013 at location Studena, 41.91 N, 26.4 E; b) Fire on 20 August 2013 at location Ostra Mogila, 42.467 N, 26.467 E.

In an invalid CAP-format file, all fire-pixels latitudes are negative. There are no any fire locations in the Northern hemisphere (positive longitude) that is not the case for the corresponding GRIB2 file. The problem is reported to EUMETSAT and entered in the incoming register of User Service Helpdesk as 300023176 Meteosat 0 Service enquiry from 23 August 2013. According to our experience, there are no any examples for such invalid CAP format files from the Rapid Scan service disseminated on EUMETCast DATA CHENNEL-6. A few invalid CAP format files for MPEF product from Full Scan Service in the end of August 2013 are listed below. L-000-MSG3 -MPEF -FIRC -000001-201308201245- L-000-MSG3 -MPEF -FIRC -000001-201308211045- L-000-MSG3 -MPEF -FIRC -000001-201308211100- L-000-MSG3 -MPEF -FIRC -000001-201308221115- L-000-MSG3 -MPEF -FIRC -000001-201308221130- L-000-MSG3 -MPEF -FIRC -000001-201308261000- L-000-MSG3 -MPEF -FIRC -000001-201308261330- The invalid CAP is a problem concerning the operational application of MPEF FIR data because fire warnings for the National Authorities should be normally provided based on the FIR data in CAP format. It was announced that the fix for this issue, regarding the data in CAP format, is introduced operationally by EUMETSAT on the 14 th November 2013. CONCLUSIONS Fire detection is subject to several remote sensing constrains because satellite data is available only at discrete intervals, as well as due to the sensor and satellite orbit geometry and cloud contamination. The results of this study for a year of moderate fire activity and a year of very low fire activity show that the different satellite fire products do not exhibit any systematic fire detection characteristics (advantages and/or shortcomings). For small fires (FRP < 100 MW per pixel, as derived by MSG data), SEVIRI fire products may fail to detect fires detected by MODIS product, and LSA SAF FRP may provide more efficient early warnings and fire monitoring than MPEF FIR. For Large fires (reaching FRP > 200 MW per pixel, as derived by MSG data), SEVIRI FRP and FIR (both based on Full Scan from 0 and Rapid Scan from 9.5 E measurements) can be equally efficient for fire detection. For the South Eastern Europe, the FIR product from Rapid Scan at 9.5 E subsatellite point provides a better view for fire monitoring than FRP, which is based on Full Scanning from 0 because of the higher spatial resolution over the region. Since the FIR and FRP algorithms are different, the performance of these two products (both using MSG SEVIRI measurements as input data) is case dependent. In synoptic situations which are favourable for development of both fires and cloudiness, SEVIRI fire products may be able to detect a fire in single slots due to their higher frequency of observations, while MODIS TAP does not detect the fire because of cloudy conditions at the moment of satellite overpassing the fire location. In other partially cloudy cases fires may be detected by MODIS TAP because of higher spatial resolution while the algorithms using SEVIRI data classify the corresponding pixel as cloudy and do not detect the fire. Invalid CAP format files currently disseminated for some slots via EUMETCast can cause problems in operational application of MPEF FIR data Therefore, for an efficient fire detection, it calls for using various available sources of information in order to avoid as mush as possible the remote sensing constrains due to the sensor and satellite orbit geometry and cloud contamination.

REFERENCES EUM (2007) Active Fire Monitoring with MSG. Algorithm, Theoretical Basis, Document. EUM/MET/REP/07/0170, 1, 11 April 2007. EUMETSAT, Darmstadt, Germany. Giglio, L., Descloitres, J., Justice, C. O., and Kaufman, Y. J., (2003) An enhanced contextural fire detection algorithm for MODIS, Remote Sens. Environ. 87. 2-3. 273-282. Govaerts, Y., Wooster, M., Freeborn, P., Lattanzio, A., Roberts, G. (2010) Algorithm theoretical basis document for MSG SEVIRI Fire Radiative Power (FRP) Characterisation. EUM/MET/SPE/06/0398, EUMETSAT, Darmstadt. LSA SAF (2010) Validation report FRP. SAF/LAND/IM/VR_FRP/V_10. Available online at: http://landsaf.meteo.pt/ algorithms.jsp;jsessionid=9d6a4c970dffb00dce20d61c9cdcc107?seltab=12&starttab=12#intro. Stoyanova J.S. and Georgiev C.G. (2010) Drought and vegetation fires detection using MSG geostationary satellites. Proceedings of 2010 EUMETSAT Meteorological Satellite Conference (Córdoba 20 24 September 2010). ISSN 1011-3932. Stoyanova J.S., Georgiev C.G., Yordanova D., Mladenov K. (2008) Active fire monitoring over Bulgaria: Validation of SEVIRI FIR product. Proceedings of the EUMETSAT Meteorological Satellite Conference 2008, 8-12 September Darmstadt, ISBN 978-92-9110-082-8, ISSN 1011-3932. Wooster, M. J., Zhukov, B., and Oertel, D., (2003) Fire radiative energy for quantitative study of biomass burning: derivation from the BIRD experimental satellite and comparison to MODIS fire products, Remote Sens. Environ. 86. 83-107.