Infrared Moisture Balance (FD-800)

Similar documents
Infrared Moisture Balance (FD-660)

Infrared Moisture Determination Balance FD-610. Operating Manual

Moisture analysis in minutes - not hours. Metal, Ceramic, Halogen or Quartz The Choice is Yours

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Pressure measuring instruments

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

incubator, the best in its class

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

EC 160 CO 2. Incubator

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Refrigerated Incubators / Environmental Testing Chambers

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Full-range moisture analysis from a single source

Number of instruction: LMI-11-02/01/08/ENG-C. Moisture analyzer MBC series

Introductions. Safe for cultivation

Constant climate chambers

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Moisture analyzer PMC series

Constant climate chambers

Counting Scales. HC-i Series.

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

WASTEWATER Online UV%Transmission Analyzer

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO2 Carbon Dioxide Sensor

ENVAIR lab CO2 Incubator

intelligent fire alarm ID60series panels

ID50series. intelligent fire alarm panels

Nardalert S3 TM Non-Ionizing Radiation Monitor

VWR symphony CO 2 INCUBATORS

Manufacturer since

Process Gas Chromatograph

THERMOMETERS Dataloggers/Refrigerator

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

SD Storage Cabinet. Outstanding performance

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Heal Force Laboratory Equipment. CO2 Incubators. Heal Force leads you to healthier life

FITOCLIMA 600 & 1200 PHARMA

Specifications Wavelength Range: 190 nm to 800 nm continuous

Black Body Calibration Source User Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Halogen Moisture Analyzer

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

SD Storage Cabinet. Outstanding performance

This document hosted by: Instruction Manual MB120 Moisture Analyzer

Operating instructions for moisture analyzers - UX 3001 (UX 3011, UX 3031, UX 3081) series

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Your competent partner for measuring and services.

Automatic Isokinetic Sampler ST5

HSD Dry Cabinet

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Model D12-IR. Digital Gas Transmitter...

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

UV Weather Resistance Test Chamber Technical Data

FitoClima 600 PDH. Climatic Chamber specially developed for reaching low humidity levels DC013EN/03

Technical data sheet TDS0060

ECOLOG Data logger series we prove it.

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

MB-T Moisture analyzers

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Photo Stability Chamber

Mercury Vapor Monitor VM-3000

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

CO2 Incubators The Complete Line

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

SDR Dry Room. Outstanding performance

XSD Dry Cabinet

FITOCLIMA 600 & 1200 STABILITY

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

VM-3000 Mercury Vapor Monitor

for Drinking Water Systems

Model gffoz Process Ozone Sensor (In-Line)

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

Specification for On-Line UPS Battery Monitoring and Data Management System

Commodity Description

Refrigerator/Freezer Thermometer

Technical data sheet TDS0034

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Multifunction IAQ Monitor

PSA Series. Particle Size Analyzer

PREMIER PLATINUM INFRARED GAS SENSOR

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Transcription:

Dual Temperature Control Moisture Analyzer (FD-800) FD-800 is premium infrared moisture determination balance which employs a revolutionary dual temperature sensor method to enable high precision moisture measurements. In addition to the thermistor that measures the environment temperature within the drying chamber, it is mounted with a radiation thermometer that measures the sample temperature directly without contact. This enables the user to optimize the heat drying settings to match the characteristics of the sample, and allows a reduction in measuring time and increase in measurement accuracy without burning or deforming the sample. This type of world-class control allows the FD800 to be the standard in R&D and QC departments desiring the finest accuracy in moisture measurement. Seven measurement modes, 10 product drying programs, and 100 test memories provide tremendous versatility of the FD-800. Data can be output to optional printers or PC's for full traceability. This feature as well as password protection for instrument and program settings allows you to maintain GMP, GLP, and ISO compliance FD-800 Dual temperature sensor In addition to the ambient temperature in the drying chamber (T1), the FD800 monitors sample temperature (T2) (Patent pending), providing unsurpassed drying control, resulting in optimized drying times, and minimizing or eliminating sample degradation and resulting measurement accuracy. Page 1 / 5

Advantages: Shortened drying time The dual-mode temperature control substantially reduces drying cycle time Advanced temperature control In addition to temperature control using a conventional thermistor (T1), a radiation thermometer (T2) is newly employed to directly measure sample temperatures, allowing advanced temperature control that makes the maximum use of the merits of both types. High accurate measurements Since the sample temperature can be measured, it is possible to set optimal drying conditions that match the characteristics of the sample, avoid burning or quality changes, and enable a more accurate moisture measurement. High precision integrated weight sensor Unibloc It has superior response, temperature, and anti-shock characteristics. Unique auto-tare mechanism Adjusts the zero drift and ensures high accuracy, even with the large sample pan Built-in mid-infrared quartz heater The 2.6 μm quartz heater provides superior heating, is not affected by sample color and doesn't over dry due to surface temperature effects. The 20,000-30,000 hour MTBF is 5-10 times longer than infrared and halogen lamps Can measure a variety of materials 100 measurement/control programs The FD-800 enables to save up to 100 different measurement modes and to test a variety of samples without "re" programming the instrument Six measuring modes Allow the user to select the optimal drying program for the sample, again assisting in optimizing drying time and measurement accuracy The FD-800 displays 30s interval moisture change volume (ΔM) numerically and on a scale. By showing the change of moisture over the last 30 seconds, the user can more efficiently develop measurement protocols Optional data logger software FDL-01 The FD800 may be connected to a PC and data automatically imported into Microsoft Excel) Data can be printed By connecting the FD-800 to an optional printer (VZ-300), information such as the intermediate drying state and final measured values can be printed out in graphical form. The radiation thermometer can be calibrated Calibration kit GF-200 is available Ability to measure a variety of sample forms Powders, Particulates, Pastes and Liquids Cereals, Foods and Chemicals Page 2 / 5

Various moisture measurements are possible with the multiple drying modes Page 3 / 5

Specifications: Measurement method Detection of weight loss by heating & drying Sample weight 0.1-120g (optional weight sampling) Measurement subject Moisture / Solid content / Weight Measurement range 0-100% (wet base, solids); 0-500% (dry base) Repeatability (standard Sample with a weight of 5g or higher : 0.05% deviation) Sample with a weight of 10g or higher : 0.02%) Resolution Moisture percentage 0.01% / 0.1%; Weight 1 mg Temperature setting range for thermistor (T1): 30-180 C (1 C interval); for radiation thermometer (T2) 30-250 C (1 C interval) Measurement modes Automatic stop mode; Timer stop mode; Rapid drying mode; Equilibrium drying mode; Step drying mode; Predictive (comparative) measurement mode Temperature range Display C in 1-degree increments when using a thermistor (T1) C in 1-degree increments when using a radiation thermometer (T2) Backlit LCD display (137 mm x 43 mm) Page 4 / 5

External output Storage of measurement conditions Data memory Temperature/ Humidity operating range Sample dish Heat source Temperature sensor Power source Power consumption Dimensions & weight Applications Options RS-232C interface 100 of measurement conditions 100 of data 5~40 C, max of 85% RH SUS (diameter 130 mm, depth 13 mm) Mid-wave infrared quartz heater (200Wx2) Termistor (T1), Radiation thermometer (T2)s AC100~120V / 220~240V (50/60Hz) Max 900W 220 (W) x 415 (D) x 190 (H), 4.5kg Pharmaceuticals, agriculture, food processing, textiles, chemicals, fertilizer, paper, construction Printer VZ-330, Radiation thermometer calibration kit GF-200, Data logger software FDL-01, Windshield with deodorizer case FW-100 Page 5 / 5