NOTEBOOK I 760 BGA/SMD Rework System. Operation Manual

Similar documents
QUICK BGA2005. Operation Manual

QUICK BGA2015 BGA/SMD Rework System. Operation Manual

QK-IR2005. User s Manual

I760B-DX BGA Rework System. Operation Manual

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

QUICK BGA2015. Precision BGA Rework System. Features:

QUICK BGA 2025 BGA/CSP Rework Station Operation Manual

BK3300/BK3300L. Intelligent Lead free Soldering Station. Instruction Manual V1.0. Warning

INTELLIGENT LEAD FREE SOLDERING STATION INSTRUCTION MANUAL V1.0 WARNING

ASE-4313 Users Manual

Instruction Manual QUICK 855PG PROGRAMMABLE SMD REWORK STAION

HRS55PG PROGRAMMABLE SMD REWORK STAION. Instruction Manual. Thank you for purchasing our SMD Rework station. The unit is exclusively designed for

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U)

474A+ TIP CARE AND USE INSTRUCTION MANUAL DESOLDERING STATION

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

QUICK EA-A10. BGA/CSP Rework Station. Operation Manual

INSTRUCTION MANUAL FOR

SMD REWORK SYSTEM. Instruction Manual 401H000505

4 Port Rework Station with 140 desoldering gun, M-type soldering iron and 670W hot air

Lead Free Soldering Pot I100-15S

SMD HOT TWEEZER. Instruction Manual

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

Desoldering Tool. Instruction Manual

Mini SMT Reflow Oven Model: T-961

34737-TL SMD REWORK STATION

LED New Light Source Reflow Oven. Model: T-960

Desoldering Tool. New. Portable Desoldering Tool. Packing List. Specifications

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

Instructio" Manual. for. Temperature Cnntrolled Soldering Station LF 1600

S ATION EWORK ST BGA R

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL. Correct Disposal of this product

VT-DESOL2 DESOLDERING STATION DESOLDEERSTATION STATION DE DESSOUDAGE ENTLÖTSTATION USER MANUAL GEBRUIKERSHANDLEIDING MANUEL D'UTILISATION

BGA Rework Station TOUCHBGA GM490 User Manual

S ATION EWORK ST BGA R

METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE

Desoldering Tool. (HAKKO FR-4102) Instruction Manual. Table of Contents

Accessories for WHA 3000P and WHA 3000V

OPERATING MANUAL FOR LF-852DII HOT-AIR S.M.D. REWORK STATION

INSTRUCTION MANUAL FOR LF-369D TENWERATURECONTROLLED SOLDERING STATION

SMD Rework Station TABLE OF CONTENTS

WHA 3000V Hot Air Station

Soldering Station INSTRUCTION MANUAL

Big Board Rework. Joerg Nolte Ersa GmbH Wertheim, Germany

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.

Instruction Manual. SMD Rework Station with Vacuum Pickup TABLE OF CONTENTS

RD-500V RD-500SV ESD SMT REWORK SYSTEM

JOVY SYSTEMS RE-7500 User Manual Rev Index

RD-500V RD-500SV ESD SMT REWORK SYSTEM

Operating Manual. for. SMD/BGA Rework System IR860

BGA Rework Station Pro-660

HAKKO 703B REWORK SYSTEM TROUBLESHOOTING GUIDE

Variable Temperature Digital Solder and Desolder Station

Int2930. Soldering Station. Instruction Manual

ZD-985 Desoldering Station

JOVY SYSTEMS RE User Manual Rev. 1.00

SMD Rework Station with Vacuum Pickup. Instruction Manual

Operation and Maintenance Manual for the SODRTEK ST 325 Digital Convective Soldering/Desoldering System P/N

Lead-Free Repairing System INSTRUCTION MANUAL AIR NOZZLES

Service: to SLK Laboratory Hot Plates glass made of ideas

474A+ INSTRUCTION MANUAL DESOLDERING STATION

touchbga.com TOUCHBGA BGA Rework Station GM330 IR+HR User Manual

852 SMD REWORK SOLDERING STATION MANUAL

SMD Rework Technology Complete solutions

SMD Rework Technology Complete solutions

NTS STRUME IN N-ON DE

premium line Stations Different equipment designed for a specific soldering or rework job

Shenzhen SCOTLE Technology 深圳市玉海源科技有限公司 SHENZHEN SCOTLE TECHNOLOGY LTD

Premium Desoldering station with Electric Pump

over 100 are used all over India by our top customers many with repeat... repeat orders

SMD Rework Station with Vacuum Pickup. Instruction Manual

Rework: IR Technology vs. Convection Air

SMT DESOLDERING DX LONER ATMOSCOPE Self-Contained SMT Deluxe Hot Air Station, Page 22

Ersa IR 550 A plus Microprocessorcontrolled Rework System

Hot Air Station Ref. JT-B

Rework System Instruction Manual

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

WHA 3000P Hot Air Station

AOYUE. Int 852A+ pro Int 852A++ pro. SMD Rework Station INSTRUCTION MANUAL. (Centigrade / Fahrenheit switchable)

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

TF 1800 and TF2800. BGA Rework Systems. Solutions and systems for soldering, rework and repair of electronics. A family-owned company since 1958

ERSA IR 500 A SMT/BGA Rework System

INSTRUCTION MANUAL Soldering Station Ref. LC-2SIA

474 DESOLDERING STATION

Soldering Station. Instruction Manual

MOBILE CALL GSM Alarm System User s Manual

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Inverter Split-type Room Air Conditioner

atten Color ^ Back to Top Clients Login Username: Password: Home About Us Products News Video Service Support Join Us Contact Us

Inverted Through Board Surface

Read this Safety Guide first.

touchbga.com TOUCHBGA BGA Rework Station HR6000 User Manual

Premium Micro Desoldering station

INT. Lead-Free Repairing System INSTRUCTION MANUAL

Transcription:

NOTEBOOK I 760 BGA/SMD Rework System Operation Manual Thank you for purchasing our IR Rework System. The system is exclusively designed for reworking and soldering SMD component. Please carefully read this manual before operating the system. Store this manual in a safe, easily accessible place for future reference.

Table Content 1. Summary...1 2. Specification and Technical Parameter...1 2.1 Specification...1 2.2 Technical Data...2 3. Product Picture...3 4. Safety Instructions...3 5. Install the unit and adjust parts...4 5.1 Place the unit...4 5.2 Check the unit...4 5.3 Install RPC...4 5.4 Connect the unit...5 5.5 Using Parts...5 6. Keyboard and parameter setting...7 6.1 IR Keyboard...7 6.2 PL Keyboard...7 6.3 Parameter setting...7 A. Input password...8 B. Modify working flow...9 C. Modify working mode...9 C-1. Modify Parameter of working flow...10 D. Modify laser alignment mode...14 E. System instruction...15 7. Technics instruction...15 7.1 Soldering Technics (Switch on the system s power)...16 7.2 De-soldering Technics (Switch on the system s power)...17 8. Turn off the system...17 9. System Maintenance...18 10. Setting & Operation about the soldering iron...18 10.1 Installation and use of the iron...18 10.1.1 Iron Holder and Sponge...18 10.1.2 Connection...19 10.2 Setting the temperature of the soldering iron...19 10.2.1 Set temperature normally...19 10.2.2 Set the temperature on-line...21 10.3 Setting working parameters...21

10.3.1 Setting password...21 10.3.2 Setting working mode...22 10.4 Sleeping...23 10.5 Calibrating the Iron Temperature...23 10.6 Select a correct tip...24 10.7 Tip care and use...24 10.8 Maintenance...25 10.8.1 Inspect and Clean the Tip...25 10.8.2 A de-tinned tip...25 10.8.3 To restore a de-tinned tip...25 10.8.4 Extending tip life...25 10.9 Error messages...26

1. Summary Thank you for using NOTEBOOK I760 Rework System. This system adopts micro-processor control and infrared sensor technology to do soldering and de-soldering to surface mount components safely and accurately and it can also control the whole technological process and record all information by means of the IR Software, thus meeting the higher technological demands of modern electronic industry. It becomes one of the most valued electronic equipments in this field. This NOTEBOOK I760 Rework System adopts micro-processor control and infrared sensor technology. It has the precision non-contact infrared temperature sensor for de-soldering parts and the middle wavelength infrared heater. The soldering process is under the monitoring of non-contact infrared sensor and optimum control of process can be achieved at any time. In order to get the best technological control and the nondestructive and reproductive PCB temperature, NOTEBOOK I760 supplies a 2400W heating power, suitable for all application, such as large or small PCB as well as lead-free process. The technology of re-flow soldering controlled by closed-loop ensures the precise and smaller technological window, even heat distribution and appropriate peak value of temperature for lead-free soldering. The middle-wavelength infrared heater of NOTEBOOK I760 has a well-proportioned and safe heating and power and flexibleness necessary for the system, so it can also deal with some PCBs with big thermal capacity and other high temperature situation (lead-free soldering) easily. The adjustable aperture under the infrared heater can protect the adjacent components (which are sensitive to the temperature) on PCB from being heated. No need for nozzles. NOTEBOOK I760 works under the open environment, that is, it can calibrate and test temperature in soldering process. When the melting of solder is found by visual inspection, press down the calibrating button to record the melting point temperature of solder. NOTEBOOK I760 has 10 types of working modes and programmable temperature controlling can modify the parameter of every work modes. IR system and setting of parameters are operated by outside Keyboard as well as by IR soft. The use of RPC (reflow process camera) provides the critical visual information to accurately judge the melting of solder during the whole soldering and desoldering process. Besides, NOTEBOOK I760 can cool down the PCB efficiently. With the intelligent lead-free digital calibrating soldering iron, it is a integrated and perfect soldering equipment for any professional user. 2. Specification and Technical Parameter 2.1 Specification 1.Max Power 2400W (Max) 2.Power of Bottom preheating 400W*4 (Infrared ceramic heating plate) 3.Power of Top heating 180W*4 (Infrared heating tube, 2~8µm Approx, Size: 60m 60 mm) 4.Preheating time of Bottom Heater 90s Approx (Size: 260 260mm) 5.Adjusting rang of Top Heater 20~60mm 6.Heating time of Top Heater Approx 10s ( From room temperature to 230 ) 7.Vacuum pump 12V/300mA, 0.05Mpa 8.Outer cooling fan 855F 9.Laser alignment tube 3V/30mA (1pcs) - 1 -

10.LCD display screen Size: 65.7 23.5 (mm) 16 2 character 11.Soldering Iron Intelligent digital display lead free soldering iron 12.Power of soldering iron 60W 13.Communication Standard RS-232C (Connect with PC) 14.Keyboard 8 Buttons 15.Upward and downward Movement Motor 24VDC/100mA 16.Upward and downward Movement Range 93mm 17.Infrared Temperature sensor 0~300 (Testing range) 18.Outside K type sensor Optional 19.Dimension 33 38 44 (cm) 20.Weight 20Kg Note: When purchasing the equipment, please point out the working voltage. 2.2 Technical Data TL: Melting temperature of solder T1: Heat preservation starting temperature of reflow soldering T2: Heat preservation ending temperature of reflow soldering T3: Peak value temperature of soldering and de-soldering T0: Valve temperature: The lowest temperature of bottom heater when top heater heats up. T0<TB TB: The set temperature of bottom heater Tb: The real time temperature value of bottom heater TC: The real time temperature value of top heater S1: Heating time rising from T1 to T2 S2: Heating time rising from T2 to T3 S3: Heat preservation time of T3 NOTEBOOK I760 Rework System has ten working modes and its parameter can be changed according to demand. Refer to the following eight parameters: 0. T1=120 S1=50s T2=140 S2=45s T3=195 S3=15s TL=183 TB=150 T0=100 1. T1=130 S1=40s T2=145 S2=45s T3=200 S3=15s TL=183 TB=160 T0=150 2. T1=140 S1=30s T2=150 S2=50s T3=200 S3=20s TL=183 TB=160 T0=155 3. T1=140 S1=40s T2=150 S2=50s T3=195 S3=25s TL=183 TB=165 T0=160 4. T1=160 S1=50s T2=180 S2=40s T3=230 S3=15s TL=217 TB=170 T0=150 5. T1=160 S1=40s T2=175 S2=50s T3=225 S3=20s TL=217 TB=180 T0=170 6. T1=170 S1=40s T2=185 S2=50s T3=228 S3=20s TL=217 TB=180 T0=180 7. T1=180 S1=40s T2=185 S2=50s T3=228 S3=25s TL=217 TB=190 T0=185-2 -

3. Product Picture Vacuum Suction Tube Movement Arm Top Heater Cooling Fan Bottom Heater PCB Fixture 4. Safety Instructions Note: For safety of system and operator, please read this manual carefully before operating the unit. Please note that the unit is suitable for soldering and de-soldering of electronic components. Note: Top and bottom IR heater will be very hot during working, so explosive and combustible object or gas and solvent is strictly prohibited in working areas, also please don touch the hot housing parts Note: The laser alignment device includes a secondary laser device, so don t see the laser bean directly. Note: When the system happens trouble and needs maintenance, it should be maintained by an experienced and authorized technicist or mavin, or contact with service agent and factory. The unit with dangerous voltage! The inexperienced work is dangerous for operators. - 3 -

5. Install the unit and adjust parts Unwrap the packing of the unit, then take it out and put it on the solid level worktable. After installing RPC, put NOTEBOOK I760 main unit on the IR base plate. Please check whether the following parts are in good condition and they aren t missed. * NOTEBOOK I760 Main unit * IR Keyboard * Outer cooling fan (Optional) * NOTEBOOK I760 Operation Manual * Intelligent lead free soldering iron and Iron holder * IRsoft Disc * Power cord * IR Base plate with PCB Fixture (Optional) * PL Keyboard (Optional) * Monitor (Optional) * RPC IR Reflow Process Camera (Optional) Note: The parts will be packed according to the packing list, if you don t purchase the optional part and it isn t in the package. If any above part is missed out, please contact with our company or agents immediately. Note: Top and Bottom heater will be very hot during working, so explosive and combustible object or gas and solvent is strictly prohibited in working areas, also please don touch the hot housing parts. 1.Install RPC fixing bracket to the bottom of baseboard and tighten the fixed screw in the bush. Fixed screw 2.Unscrew the RPC fixed knob on the bracket and install RPC on it, tighten knob. 3.Put the plug of RPC into socket. - 4 -

Install RPC herein. RPC Fixed knob Plug of PL Keyboard Socket 24V Power RPC Fixing Bracket RPC * Please check whether the power voltage accords with the rated voltage on the equipment nameplate. * Please check whether switches are turned off. (Set to 0 ) * Connect Power cord to the power socket behind equipment. * Connect PL Keyboard to RPC. * Connect IR Keyboard to IR Keyboard socket behind unit. * Connect intelligent lead free soldering iron to IRON socket behind unit. * Connect the video lead in the RPC Fixing Bracket to corresponding socket in the Monitor. * Inert the plug of 24V Power into power socket of RPC * If need, connect K type sensor (optional) to the sensor socket behind unit. * If you use IR Soft, please connect the RS232 connecting cord to the RS232 socket behind the unit. After finishing above steps, insert power plug into power socket, and switch on power. Connect K type sensor Power switch Connect grounding cord Connect Lead free iron Connect IR Keyboard Connect RS232 cord Connect Power cord * Aperture system The aperture system of IR heater on the top of equipment can be adjust from 20 20 (mm) to 60 60 (mm) by two adjustment knobs. Unscrew the knob before adjusting, and adjust the window size, then screw down - 5 -

the knob. The scale 2 on the housing means 20mm and 3 means 30mm, other scale is similar. For example, if you want to adjust it to 50 50 (mm), adjust two knobs to the scale of 5 and screw down them. Note: Adjusting the aperture system can protect the adjacent components on the PCB from being heated. But, when the aperture system is adjusted to small size, the top IR heater will become very hot, so it s necessary to increase the size appropriately to avoid being cut off of the safety switch on top IR heater. Adjustment knob Scale * PCB Fixture (optional) Movable PCB fixture is able to fix PCB with different size. The Lock Knobs lock PCB Fixed Bar to fix PCB. Unscrew PCB Lock Knobs and push Sliding Blocks by hand to open PCB Fixed Bars, make the distance between PCB Fixed Bars accord with PCB size. Fix PCB between them and screw down PCB Lock Knobs after adjusting position. The fixture can move toward to front and back. Adjust the movable bar toward front or back and then screw the PCB Lock Knob of fore-and-aft movable fixture. Movable bar PCB Lock Knob PCB Lock Knob of fore-and-aft Sliding Block movable fixture PCB Fixed Bar - 6 -

6. Keyboard and parameter setting A. During selecting working flow period, and keys are used for controlling the moving upward or downward of cursor and increase or decrease of number. During the soldering or de-soldering period, also top IR heater haven t yet started to heat up, key and key are used for controlling movement upward or downward of top IR heater. That is to say, during movement upward and downward of top IR heater, after pressing the key BEGIN, and keys make the top heater stop at a proper position. B. Under the standby condition, if the cooling fan have already drawn back, press and keys to make the top IR heater move up and down. C. Under the standby condition and the top IR heater is at top position, press ALIGN key, the cooling fan (it has laser alignment device inside) will hold out or draw back. When cooling fan completely holds out, the laser alignment device will switch on automatically. After the cooling fan has held out, if you double click ALIGN key, the cooling fan will be on or off. D. Function of SET key: Make the BGA-IR enter parameters setting mode and cursor move a step forward. E. Function of EXIT key: During the setting mode, make BGA-IR cursor exit until exiting the setting mode; During the soldering or de-soldering period, make BGA-IR exit operation. F. Function of BEGIN key: During the standby condition, make BGA-IR get into soldering or de-soldering situation. G. Function of CAL TL Key: During the soldering or de-soldering process, when the temperature increase from T2 to T3, press this key, the current temperature will multiply a coefficient to make TC=TL, calibrating TL. After the flow has finished and come back to initialization, it will save the coefficient. H. Function of CAL Delay Key: During the soldering or de-soldering process, pressing this key, make the setting value of S3 delays five seconds after the temperature up to T3. If pressing the key continuously, the time of heating (S3) continuously prolongs. Note: If press CAL TL Key again in the initialization situation, the temperature calibration coefficient of TL comes back to system initialization 1. A. Press LIGHT B or LIGHT T + keys simultaneously to increase the brightness of RPC light. Press LIGHT B or LIGHT T + keys simultaneously to decrease the brightness of RPC light. B. ZOOM+ and ZOOM- keys are used for controlling zooming of image. C. FOCUS+ and FOCUS- are used for the camera focusing. Parameter settings order as the follows: A._password: *** (Password settings) B._select: 0 (Flow settings, it can modify parameter inside.) C._type: solder (Working mode settings) D._laser: off (Laser alignment settings) - 7 -

E._baud: 19200 (Communication speed settings) A. Input password The initial password of system is 000. At the same time, system also has the omnipotent password 159. If you forget the setting password, you can input 159 to make the password of system come back to initial password 000. Note: If want to modify parameter of system, you must input correct password, otherwise, you can only browse them. For instance: Input the initial password 000 of system. When in initial state, TC, Tb display room temperature. TC:022 C Tb:019 C _password: *** ready for flow select: 0 password: *** password: 0** select: 0 select: 0 password: 0** password: 00* select: 0 select: 0 password: 00* password: 000 Press EXIT select: 0 select: 0 Saving Password! Any key return Finish password inputting: 1. If you want to modify the password, return to above mode to input the new password. If password is modified successfully, it will show: - 8 -

Saving Password! Any key return 2. If you want to modify the next working flow, operate as the following B item; If you don t want to modify, please press key to browse the following parameter settings. B. Modify working flow For instance: Modify the working flow and make it become 1 flow. password: *** password: *** select: 0 Step1 select: 0 Step2 password: *** Press password: *** Press EXIT select: 0 Step3 select: 1 Step4 password: *** select: 1 1. When carry on the forth step (Step4), if press SET key, you can browse and modify parameter of this flow, shown as C-1 item. 2. After finishing modifying of working flow 1, if you want to modify the next working mode, operate as C item shows; If you don t want to modify it, yon can press key to browse the next parameter settings. C. Modify working mode For instance: Modify the working mode and make it in desolder mode. password: *** select: 1 select: 1 type: solder - 9 -

select: 1 or select: 1 Press EXIT type: solder type: desolder select: 1 type: desolder After finishing modifying working mode, if you want to modify laser alignment mode, operate as D item shows; if no need to modify it, please press key to browse the next parameter settings. C-1. Modify Parameter of working flow 1. If it is necessary to modify parameter of a working flow, first you must select the working flow and then modify its parameter. 2. The modification of parameter must accord with the following technics graph. TL T3 TB Tb=T0 S2 S3 T1 T2 Tb TC S1 Tb TC The soldering technics is decided by T0, TB, T1, T2, T3, S1, S2 and S3. It describes the temperature graph during the system working. TL denotes Melting temperature of solder and the range between T2 and T3. T0 T0 is the valve temperature for bottom heater required by top heater when it heats up. Also it is the first temperature of this technics process. When the work flow begins, the bottom heater starts to heat up. After reaching the T0, the top heater begins to heat up. TB, Tb, TC TB: The setting temperature of bottom preheating Tb: Real-time temperature of bottom heating TC: Real-time temperature of top heating T1 It is the heat preservation starting temperature of reflow soldering. It is the second temperature of this - 10 -

technics process. The temperature rises to T1 with a proper speed the component permits. In parameter modifying, use the and key to set the value of T1. T2 It is the temperature when finish the heat preservation of reflow soldering. The pre-heating temperature rises to T2, after the time of S1 finishes. Within this time, PCB and component pre-heating is finished and the solder is activated. In parameter modifying, use the and key to set the value of T2. T3 It is the peak value temperature of reflow soldering. When the temperature reaches T2, the temperature equably rises to T3 with a definite raising speed. The soldering or de-soldering will be finished when the temperature reaches to the peak value and performs the next step. In parameter modifying, use the and key to set the value of T3. TL Melting temperature of solder. At this temperature, the solder starts to melt down and turn into liquid. During the soldering and de-soldering, users can press CAL TL Key to calibrate the value of TL when the solder turn into liquid. In parameter modifying, use the and key to set the value of TL. S1 Heating time rising from T1 to T2. User can set the value in the range of 0~300s. S2 Heating time rising from T2 to T3. User can set the value in the range of 0~300s. S3 Prolonged heating time (Heat preservation time) after the temperature reach T3, and user can also set the value in the range of 0~300s. Unit It s able to set the unit of display temperature during work flow. In parameter modifying, use and keys to set the value of it. Sense It is used for choosing the system s sensor type. Users can also choose K type sensor used for measuring temperature, besides system s IR sensor. The signal of chosen sensor will be displayed and used for process controlling. In parameter modifying, use the and key to set the value. Password It is used for setting password. It is designed for preventing the equipment unnecessary or non-authorized change. When it is set to 000, the password protecting is useless. The password is used for all flows and it can be useful and useless in each flow. The system requires inputting correct password before any change. Using of password refer to A item. For instance : Modify parameter of flow one (Flow one has been selected) and make T1=130, S1=70s, T2=160, S2=50s, TB=130. - 11 -

password: *** _T1: 110 select: 1 S1: 060s T1: 110 T1: 110 Press twice S1: 060s S1: 060s T1: 130 Press EXIT _T1: 130 S1: 060s S1: 060s T1: 130 T1: 130 _S1: 060s S1: 060s T1: 130 Press T1: 130 Press EXIT S1: 060s S1: 070s T1: 130 S1: 070s S1: 070s T2: 150 S1: 070s S1: 070s Press T2: 150 T2: 150-12 -

S1: 070s T2: 160 Press EXIT S1: 070s T2: 160 T2: 160 T2: 160 S2: 030s S2: 030s T2: 160 Press twice T2: 160 Press EXIT S2: 030s S2: 050s T2: 160 S2: 050s S2: 050s T3: 200 T3: 200 S3: 010s S3: 010s TL: 183 TL: 183 TL: 183 TB: 140 TB: 140 TL: 183 TL: 183 Press EXIT TB: 140 TB: 130-13 -

TL: 183 TB: 130 TB: 130 T0: 090 T0: 090 unit: unit: sense: IR sense: IR type: desolder D. Modify laser alignment mode For instance: Modify the laser alignment mode and set it to on. select: 1 type: desolder type: desolder laser: off type: desolder or type: desolder Press EXIT laser: off laser: on type: desolder laser: on 1. After finishing the modification, the next step communication speed, will not be able modified by keyboard. 2. Press EXIT key to exit. Now, the system has saved all parameter settings, IR window will display: - 14 -

TC:022 C Tb:019 C ready for flow 3. After all technological parameters have been selected, press BEGIN key and the system perform the set flow. E. System instruction 1. In initial state, if the top sensor or outer sensor is broken, it displays: TC: *** Tb: *** T sense error! If the bottom sensor is broken, it displays: TC: *** Tb: *** B sense error! When happening above status, user must stop operating. 2. During movement upward and downward of Top Heater or holding out and drawing back of fan arm, if it doesn t reach over 10 seconds, the unit will come back to initial state all and singular in spite of what state it is here. It displays: TC: *** Tb: *** Move error! 3. When TC is less than 180 during working, if the rising temperature is less than 7, and the system will exit the process and display TC raise error. 4. If TC is more than 265 during working, the system will also exit the process and display TC over error. 7. Technics instruction - 15 -

Note: Top and bottom Heater will be very hot during working, so please don touch the hot housing parts. Note: The laser alignment device includes a secondary laser device, so don t see the laser bean directly. 1. Turn on power switch of each part. 2. Move PCB Fixture with fixed PCB to make PCB over the Bottom Heater and make the soldered component between Top Heater and Bottom Heater. The position is easy to be measured with laser alignment device. The right position should make the red laser point in the center of component. The component which to solder on the PCB have been aligned before soldering. Suggest to use PLI760 precision placement system. 3. Adjust aperture system to get a proper window size. 4. Adjust RPC in appropriate place, adjust size and focus of image with PL keyboard to display component image in the monitor clearly. 5. Select parameter with keyboard. (Refer to Parameter setting ) A. Input password 000 B. Select the required flow, if need to modify, perform relevant operation. C. Select solder working mode. D. Select IR laser alignment mode. E. Not to change communication speed, and press EXIT key to exit. IR window shows: TC:022 C Tb:019 C ready for flow F. Press BEGIN key and the system start to work, perform content of selected flow. 6. IR window will show series of setting temperatures and the current temperature of Tb and TC during working, and indicate when it reaches T0, T1, T2, T3 and TL. S1, S2 and S3 are counted down and user can know about the setting value clearly. 7. If you see the solder has melted down (It is watched with IR camera and LCD), you can press CAL TL Key to calibrate temperature of TL to adjust the display temperature to liquid temperature TL. 8. When the temperature reaches TL, there will be a voice signal. 9. When the temperature reaches T3, the voice signal is change to a hurry sound and the system prolongs heating by S3 seconds, after it, the system will not heat up anymore, and the technical process is over. 10. The system can perform a series of function action during working. A. After press BEGIN key, the top heater move downwards near to bottom. B. After the system sounds unvaryingly, the top heater move upwards and cooling fan spread out to blow cooling wind. C. After 150 seconds, the cooling fan stop blowing, and the soldering technics has finished. 11. The cooling fan stop working and the whole process has finished. 12. Move the PCB Fixture over to cool PCB with Cooling Fan. - 16 -

1. Turn on power switch of each part. 2. Fix the PCB on the top of Bottom Heater and make the de-soldered component between Top Heater and Bottom Heater. The position is easy to be measured with laser alignment device. The right position should make the red laser point in the center of component and the suction pad also in center of component. 3. Press the vacuum suction tube to check whether suction pad is in the center of component. (If the deflection is too much, the tube will not be able to pick up the component. 4. Adjust aperture system to get a proper window size. 5. Adjust RPC in appropriate place, adjust size and focus of image with PL keyboard to display component image in the monitor clearly. 6. Select parameter with IR keyboard. (Refer to Parameter setting ) A. Input password 000 B. Select the required flow, if need to modify, perform relevant operation. C. Select desolder working mode. D. Select IR laser alignment mode. E. Not to change communication speed, and press EXIT key to exit. IR window shows: TC:022 C Tb:019 C ready for flow F. Press BEGIN key and the system start working, perform content of selected flow. 7. After pressing BEGIN key, bottom heater starts to heat up and top heater moves downwards and reach to bottom. 8. IR window will show a series of setting temperatures during working. Indicate when it reaches T0, T1, T2, T3 and TL. When the bottom temperature reaches T0, the top heater begins to heat up. 9. When the temperature reaches TL, it will give a sound alert automatically (Low frequency). 10. When the temperature reaches T3, it will also give a sound alert automatically. (Middle frequency) 11. When the solder has melted down, press the vacuum suction tube to pick up the component. 12. Press the vacuum suction tube, the vacuum pump start to work and pick up component, then return to original position. The system stops heating. 13. The top heater moves upwards and stops at top. 14. Cooling fan spreads out to blow cooling wind. 15. 90 seconds after the Top Heater moving upwards, the vacuum suction tube looses component automatically. 16. After cooling fan blowing cooling wind for 150 seconds, the whole soldering technics has finished. 17. Move the PCB Fixture over to cool PCB with Cooling Fan. 8. Turn off the system Please turn off power switch of each part and pull out power plug when not using it. - 17 -

9. System Maintenance Remark: For ensuring reliable function and maintenance of equipment, please use parts provided by original factory. Note: After cutting off the power supply, the housing is still very hot, so please don t use any dangerous or combustible solvent to clean it. Clean parts: Clean the dust on system with clean towel. Use the towel with cleaning oil to clean PCB fixture and orbit. Solder on the gridding of the bottom heater can be cleaned out with hard object. Replacement of suction pad: If you want to replace the suction pad, please turn off power and replace it after the vacuum suction nozzle and the top heater have cool down. Take suction pad out of suction nozzle downwards, and install a new one in opposite direction. 10. Setting & Operation about the soldering iron The soldering iron can be used to clean the PCB, soldering or de-soldering and so on. CAUTION: Before setting, please check whether the voltage and power accords with the rated voltage on the unit s nameplate. 10.1.1 Iron Holder and Sponge! The sponge is compressed. It will swell when moistened with water. Before using the unit, moisten the sponge with the water and squeeze it dry. Failure to do so may result in damage to the soldering tip. 1. Dampen the small cleaning sponge with water and then squeeze it dry. 2. Place it in groove of the iron holder base. 3. Add a little water to iron holder. The small sponge will absorb water to keep the large sponge around it wet at all times. 4. Dampen the large cleaning sponge and place it on the iron holder base. Note: If the sponge becomes dry during working, add appropriate water. - 18 -

10.1.2 Connection! Be sure to turn off the power switch before connecting or disconnecting the soldering iron. Failure to do so may damage the soldering iron. 1. Connect the connector of the handle cord to the socket behind the unit. Take notice of inserting position about connector. 2. Place the soldering iron in the iron holder. 3. Insert power plug into grounded power socket. 4. Connect one end of grounding wire to grounding hole of unit and the other to ground. 5. Turn on power switch. 6. Press the * button to display the preset temperature. It will be displayed for two seconds.! Make sure the temperature of the iron can be adjusted (password is correct or the password is initial 000 ). When setting temperature, the heating element is on. Operate as following steps. 10.2.1 Set temperature normally If the * button is pressed for less than one second, the present temperature setting will be shown for two seconds and then the display will return to showing the tip temperature. Example: 400 to 350 1. Push the * button and the hold it down for at least one second. The left-most digit (the 100 s digit ) in the display will flash. This indicates that the iron is in temperature setting mode and that the 100 s digit can be adjusted. - 19 -

2. Select the desired value for 100 s digit. Use the and button to change displayed value as follows. Press the button when the desired value is displayed. This will cause the middle digit (the 10 s digit) in the display to begin flashing. Page 6 3. Select the desired value for the 10 s digit. Use the and button to change displayed value as follows. Press the button when the desired value is displayed. Here, the right digit (the 1 s digit) will begin flashing to indicate that the 1 s digit can be set. 4. Select the desired value for the 1 s digit. Using the or button will change displayed value as shown above for the 10 s place selection. Press * button. Here, pressing the * button a) Enter the temperature setting into the internal memory. b) Displays the temperature setting c) Starts heater control. Note: If you turn off the power switch during the temperature setting, setting value will not be stored in the memory. If a temperature value outside of this range is selected, the display will return to flashing the 100 s place. If this happens, reenter a correct temperature value. - 20 -

10.2.2 Set the temperature on-line In the work, if it is necessary to set temperature quickly and the heat elements cannot be cut off, the way may be selected. Temperature rising: Press knob directly. If so, the setting temperature will raise 1 and the display window will display the set temperature. When loosen the knob, the display window will delay to display the set temperature about 2 seconds. If within 2 seconds, press the knob again, the setting temperature will raise 1 again. If press the knob and not loose at least 1 second, the setting temperature will rise rapidly. Till the needed temperature reaches, then loose the knob. Temperature dropping: Press knob directly. If so, the setting temperature will drop 1 and the display window will display the set temperature. When loose the knob, the display window will delay to display the set temperature about 2 seconds. If 2 seconds later, press the knob again, the setting temperature will drop 1 again. If press the knob and not loose at least 1 second, the setting temperature will drop rapidly. Till the needed temperature reaches, then loose the knob. The iron has the following working parameters. If you want to set parameters, you must input right password. Setting parameters as followings: 10.3.1 Setting password The initial password in iron s memory is 000. The setting temperature is admitted in this status. If need to restrict the setting temperature, the password must be changed and turn off the unit, then turn on. 1. Turn off the power switch, Press and hold the and buttons simultaneously, then turn on the power switch. 2. Continue holding down the and buttons until the display shows. 3. When the LED shows, the iron is in parameter setting mode. 4. Press the button, the LED shows, and the leftmost digit (the 100 s digit) in the LED will flash. This indicates the iron is in password setting mode and the 100 s digit can be adjusted. Use the and button to change displayed value. Set the password value in the same way described in Input calibration temperature. After selecting the password of three digit, press the button. 5. If the iron enters into normal work state after display window shows the current setting temperature for two seconds, this indicates the input password is error, and the temperature setting can t be done. - 21 -

6. If the display window shows, this indicates the password of input is correct. After displaying about 4 seconds, the iron comes into normal work state, and the temperature setting and parameter setting will be admitted. 7. When display window is showing, press the button, and shows, it indicates the iron comes into inputting new password state. Press and button to change displayed value. See set temperature normally. 8. When three digits are selected, press button, the display window shows, again. Now input the new password once again. Repeat the same steps. 9. If the latest two passwords are the same, pressing button will modify the password successfully. The new password is stored into the internal memory. 10. If the latest two passwords are not the same, pressing button, and the display window shows, it needs to rewrite new password. (See the last 8~9 step). The changing of password is successful until the latest two passwords are the same. Note: The word of password is 0 to 9, ten figures. If not, the input password is invalid. 10.3.2 Setting working mode 1. When the display window shows, press and buttons simultaneously, then the display shows. This indicates the unit comes into working mode setting state, and pressing or button will change displayed value as shown below: 2. After selecting the working mode, press button. The working mode is stored into the internal memory. Please refer to the Working Mode Table for the meaning of the digit displayed. Note: X represents the original working mode digit. Warning: The heater and soldering tips will be seriously oxidized or damaged when working with a high temperature. So please choose the working mode carefully and try to operate with a lower temperature if possible. - 22 -

0 2 4 6 0. 2. 4. 6. High frequency Soldering iron High frequency special very large type of soldering tip High frequency soldering iron High frequency soldering iron High frequency soldering iron High frequency tweezers or using special very large type of soldering tip High frequency soldering iron High frequency soldering iron 200-420 60W Iron Yes 200-420 60,90W Iron Yes 50-420 60W Iron Yes 200-480 60W Iron Yes 200-420 60W Iron No 200-420 60,90W Iron No 50-420 60W Iron No 200-480 60W Iron No If sleeping and working mode are selected, and the soldering iron is not used for 20 minutes, the power to the heating element will be decreased, and the display shows. This state is sleeping mode. When the iron is in sleeping mode, the tip temperature will decrease to 200 (if the set temperature is more than or equal to 200 ) or 50 (if the set temperature is less than 200 ) and remain the temperature until resuming the iron. To resume soldering, there are several ways as follows: 1. Cycle the power switch OFF, then ON. 2. Hit any one key among the keys, and *. 3. Take up the iron hand. If the soldering iron is not resumed more than 40 minutes after it comes to sleep, the power supply will be shut off automatically, and the display window will not show anything. The Soldering Iron should be recalibrated after changing the iron or replacing the heating element or tip. Method of recalibrating temperature: Use the thermometer to calibrate. 1. Set the iron s temperature to a certain value. 2. When the temperature stabilizes, measure the tip s temperature with thermometer and write down the reading. - 23 -

3. Press button not loose and press the and buttons simultaneously, the soldering iron enters into calibration mode. 4. At the moment, the 100 s digit of LED display temperature is flashing. Press the and buttons to select the value and press the button to select the digit. Press button after inputting the reading. Here, the calibration operation has been finished. 5. When inputting calibration temperature, if the value of calibration temperature is error and the iron have protection function after input the calibration temperature and press * button, the 100 s digit of display temperature will flash. 6. If the temperature still has deflection, you can repeat calibration in accordance with above steps. Recommend using the 191/192 thermometer for measuring the tip temperature. If the unit is locked by password, it will not be able to calibrate and you must input the right password. 1. Select a tip that maximizes contact area between the tip and solder joint. Maximizing contact area gives the most efficient heat transfer, allowing operators to produce high quality solder joints quickly. 2. Select a tip that allows good access to the solder joint. Shorter tip lengths allow more precise control. Longer or angled may be needed for soldering densely populated boards. 1. Tip temperature High soldering temperatures can degrade the tip. Use the lowest possible soldering temperature. The excellent thermal recovery characteristics ensure efficient and effective soldering event at low temperatures. This also protects the sensitive components from thermal damage. 2. Cleaning Clean the tip regularly with a cleaning sponge, as oxides and carbides from the solder and flux can form impurities on the tip. These impurities can result in defective joints or reduce the tip's heat conductivity. When using the soldering iron continuously, be sure to loosen the tip and remove all oxides least once a week. This helps prevent reduction of the tip temperature. 3. When not in use Never leave the soldering iron sitting at high temperature for long periods of time, as the tip's solder plating will be covered with oxide, which can greatly reduce the tip's heat conductivity - 24 -

4. After use Wipe the tip and coat it with fresh solder. This helps to prevent tip oxidation. 10.8.1 Inspect and Clean the Tip Caution: Never file the tip to remove oxide. 1. Set the temperature to 250. 2. When the temperature stabilizes, clean the tip with the cleaning sponge and check the condition of the tip. 3. If there is black oxide on the solder-plated portion of the tip, apply new solder (containing flux) and wipe the tip on the cleaning sponge. Repeat until the oxide is completely removed. Coat with new solder. The solder protects the tip from oxidation and prolongs the life of the tip. 4. If the tip is deformed or heavily eroded, replace it with a new one. 10.8.2 A de-tinned tip A detinned tip is one which cannot wet with solder. This exposes the plating to oxidation and degrades the heat transfer efficiency of the tip. (1) Failure to keep the tip covered with fresh solder while not in use. (2) High tip temperatures. (3) Insufficient melting in soldering operations. (4) Wiping the tip on dirty or dry sponges and rags. (Always use a clean, wet, industrial grade, sulfur-free sponge.) (5) Impurities in the solder, iron plating, or on the surfaces to be soldered. 10.8.3 To restore a de-tinned tip 1. Remove the tip form the solder handle and allow the tip to cool down. 2. Remove scale and oxides from the timed area of the tip with 80-grit abrasive polyurethane foam stock or a 100-grit emery cloth. 3. Wrap rosin core solder ( 0.8mm diameter or larger) around the newly exposed iron surface, insert the tip into the handle, and turn on the power switch. NOTE: the de-tinned tips are preventable by proper daily care! 10.8.4 Extending tip life 1. Tin the tip before and after each use. This protects the tip from oxidizing, and prolongs tip life. 2. Do the job at the lowest temperature. Lower temperatures decrease tip oxidation and are easier on the components being joined. - 25 -

3. Use fine point tips only when necessary. The plating on fine precision tips is less durable than the plating on blunter tips. 4. Do not use the tip as a prying tool. Bending the tip can cause the plating to crack, shortening tip life. 5. Use the minimum activation flux necessary to do the job. Higher activation flux is more corrosive to the tip plating. 6. Extend tip life by switch the system off when not in use. 7. Don t apply pressure to the tip. More pressure does not equal more heat. To improve heat transfer, use solder to form a thermal bridge between the tip and the solder joint. Various error messages will be displayed when there is something wrong with the unit. If there is a failure in the sensor or anywhere in the sensor circuit, S-E will be displayed and power to the soldering iron will be cut off. If power is being sent to soldering iron and the tip temperature goes below the setting temperature about 80, the temperature display will flash. Draw your attention to this. If power can t be sent to soldering iron, the display window will show H-E. This indicates the possibility of a heater malfunction. - 26 -