Extractor Installation Procedure Move the unit to the location where it is going to be installed and remove the unit from its packaging.

Similar documents
Material Safety Data Sheet

Material Safety Data Sheet Masonite TM Hardboard

Material Safety Data Sheet

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

Z86 Safety-Plus Industrial Cleaner Concentrate

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

This MSDS has been compiled in accordance with - EC Directive 91/155/EC - OSHA's Hazcom Standard (29 CFR )

MATERIAL SAFETY DATA SHEET

PRODUCT SAFETY DATA SHEET

Radiator Additive. ZetaLube. Description

MATERIAL SAFETY DATA SHEETS. SECTION I Manufacturer/Distributor Telephone No.: (315)

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

Kent Reef Carbon Material Safety Data Sheet

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

3.1. Substances Not applicable 3.2. Mixtures Name Product identifier % GHS-CAN Classification GHS-US classification

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

MATERIAL SAFETY DATA SHEETS

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

EMERGENCY PHONE: or (651) (24 hours)

Solid Fiber Sheets Safety Data Sheet Revision Date: 02/04/2016 Date of issue: 02/04/2016 Version: 1.0

Disposal Manual. m{zd{ 6. Capacitor( -ELOOP ) October 2012 Mazda Motor Corporation

Material Safety Data Sheet

SAFETY DATA SHEET CHUBB ABE40 DRY CHEMICAL POWDER FIRE EXTINGUISHER FLAMEGUARD R ABE DRY CHEMICAL POWDER FIRE EXTINGUISHER

MATERIAL SAFETY DATA SHEET

EMERGENCY PHONE: or (651) (24 hours)

SAFETY DATA SHEET. 1. Chemical Product and Company Identification. 2. Hazards Identification. 3. Composition/Information of Ingredients CH 3

1. Chemical Product and Company Identification

Material Safety Data Sheet

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 02/12/2016 CATCHMASTER Brand Adhesive Devices

MATERIAL SAFETY DATA SHEET 3M Micropore Surgical Tape 1530, 1530S, 1530B, 153NS, /24/12

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Emergency Telephone Number Emergency Number : CHEMTREC / CANUTEC

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

EMERGENCY PHONE: or (651) (24 hours)

Chargebuster Ion Gun Installation, Operation and Maintenance

MATERIAL SAFETY DATA SHEET

EMERGENCY PHONE: or (651) (24 hours)

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

EMERGENCY PHONE: or (651) (24 hours)

Paper Tape Safety Data Sheet*

Material Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

EMERGENCY PHONE: or (651) (24 hours)

PARABOND DETACH II Adhesive Remover

Chargebuster Ion Gun Installation, Operation and Maintenance

EMERGENCY PHONE: or (651) (24 hours)

Bench Top Ionizer Installation, Operation and Maintenance

Industrial Descale Solutions & Descale Services

LOP-3600 Safety Data Sheet

PRODUCT SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

MATERIAL SAFETY DATA SHEET 3M Earloop Fluid Resistant Face Mask Cat. # 1820, 1820FS 09/18/12

Preparation Date: February 9, 2018 Revision Date: -- Version: 1 0. INTRODUCTION

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET 3M Single Coated Medical Plastic Tape 1527L, 1527LX, 1527SP and 1527ENP 02/21/11

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

Zep Dyna Clean Installation and Operator's Manual

MATERIAL SAFETY DATA SHEET 3M Durapore Surgical Tapes Cat. # L (with liner) and 1538S series 02/03/12

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 11/06/14 CATCHMASTER Brand Adhesive Devices. Peanut Butter Mouse Size Glue Boards

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

Material Safety Data Sheet

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 2. COMPOSITION/INFORMATION ON INGREDIENTS

Powr-Zone Ozone Generator

ICE BANK DESCALER & ICE MACHINE CLEANER

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet. acc. to ISO/DIS Printing date 01/26/2001 Reviewed on 03/28/2000

07/18/2016 EN (English US) 1/8

Material Safety Data Sheet

Inclyno 2 Sieve Shaker SV020. Impact Test Equipment Ltd & User Guide. User Guide

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

MATERIAL SAFETY DATA SHEET FOR MOISTUREGUARD FOR CCA. 1.0 Introduction NZS 5433:1999.

INSTRUCTION MANUAL. Stirring Hotplate, Cimarec. Brand :

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 2. COMPOSITION/INFORMATION ON INGREDIENTS 3. HAZARDS IDENTIFICATION 4. FIRST AID MEASURES

HWX GAS BOILERS USER S INFORMATION MANUAL

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014 BIG RIG NEW EQUIPMENT YELLOW

Material Safety Data Sheet. Printing date 09/13/2011 Reviewed on 09/13/2011

Safety Data Sheet CONKLIN COMPANY, INC.

FILE NO.001 NAME OF PRODUCT MSDS DATE: 01/01/2018

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

BETACURE 100 CO-REACTANT

Material Safety Data Sheet

SAFETY DATA SHEET (603)

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5 5 GALLON BENCH TOP

Certificate of Compliance

Certificate of Compliance. 1.2 ITEM NUMBER AND SIZES: ml, ml, ml, ml

Transcription:

TECHNICAL BULLETIN TB-4012 Fume Extraction Inspection Remove the Fume Extractor from the shipping carton and inspect for damage. Items included with model 35440: 1 MENDA Solo Extractor with one inlet, 120VAC 1 35456 30" 50mm ESD Stay Put Extraction Arm with Nozzle 1 35457 5' 50mm Flex Hose 1 35454 Flip Top Flush Seal Mounting Plate includes a grounding wire with ring terminal 1 35453 Table Bracket Installation Kit 2 35458 Jubilee Clips 1 Sleeve 1 6' Power Cord, 120VAC, North American Plug 1 35451 Combined Filter (HEPA) 1 35450 Pre-Filter, Pack of 5 Made in Britain 35452 Gas Filter is availible as an option Items included with model 35445: 1 MENDA Duo Extractor with two inlets, 120VAC 2 35456 30" 50mm ESD Stay Put Extraction Arms with Nozzle 2 35457 5' 50mm Flex Hoses 2 35454 Flip Top Flush Seal Mounting Plate includes a grounding wire with ring terminal 2 35453 Table Bracket Installation Kits 4 35458 Jubilee Clips 2 Sleeves 1 Black Inlet Cover 1 6' Power Cord, 120VAC, North American Plug 1 35451 Combined Filter (HEPA) 1 35450 Pre-Filter, Pack of 5 35440 35452 Gas Filter is availible as an option Items included with model 35460: 1 - MENDA Quad Extractor with two inlets, 120VAC 1-35461 Filter All accessories are sold separately. 2 - Item 35459 (75mm Funnel Arm) are recommended. 35459-40" 75mm Mounted Arm Funnel 35445 35456-30" 50mm Extraction Arm with Nozzle 35457-5' 50mm Flex Hose Sleeve 35458 - Jubilee Clips Power Cord Back BACK 35453 - Table Bracket Installation Kit 35454 - Flip Top 35460 TB-4012 February 2012 Page 1 of 10

Installation Extractor Installation Procedure Move the unit to the location where it is going to be installed and remove the unit from its packaging. Caution The unit should be installed in a well ventilated room. Ensure that a 18" space is available around any louvered areas of the unit to ensure adequate air flow. Do not block or cover any louvers or cooling holes on the unit as this severely restricts air flow and may cause damage to the unit. The filtered air exhaust is at the base of the 35440, 35445 and 35460 units. Under no circumstances should the exhaust outlet(s) be covered as this will restrict the airflow and cause overheating. Check filters are located in their correct position and carefully replace lid. Connect the extraction ducting between the extractor inlet(s) and the extraction arms using hose adaptors and jubilee clips as required. Ducting runs should be kept as short as possible. The 35440 and 35445 are supplied with an installation kit. This kit gives the option of fixing the extraction arms through the workbench using the flip top flush sealing mounting plates (Figure 2) or the clamp on bench mount brackets as preferred (Figure 3). The top of the work bench must be suitably drilled using a 2.5" hole cutter if the flip top flush sealing mounting plates are used. When using the flip top use the grounding wire with ring terminal to ground the ESD Stay Put Extraction Arm with Nozzle (Figure 1) to equipment ground (preferably 3-wire AC outlet ground). For the 35460 the required installation fittings would have been selected at the time of ordering. GREEN WIRE UTILITY GROUND POINTS RING TERMINAL CAN BE ATTACHED HERE Figure 1 TB-4012 Page 2 of 10

Arm Arm Bolt Flip Top Table Sleeve Jubilee Clip Flex Bolt Flip Top Table Bracket Washer Nut Sleeve Jubilee Clip Flex C-clamp Jubilee Clip Lid 50mm Inlet Jubilee Clip Lid 50mm Inlet Figure 2 Figure 3 Operation On/Off switch These extractor units are turned on and off by using the switch on the front or rear of the unit. See the note below for units supplied with a remote flow control box. Single LED Filter condition indication On 35440 and 35445 units only, an LED on the front panel of the machine will illuminate when the filters need attention. See the Maintenance section for information on changing filters. TB-4012 Page 3 of 10

Maintenance General User maintenance is limited to cleaning the unit and replacing the filters with new. Only MENDA is authorized to carry out component testing and replacement. Unauthorized work or the use of unauthorized replacement filters may result in a potentially dangerous situation and/or damage to the extractor unit, and will invalidate the manufacturer s warranty. Cleaning Unit The powder coated finish can be cleaned with a damp cloth and non aggressive detergent. Do not use an abrasive cleaning product as this will damage the finish. The cooling inlets and outlets should be cleaned once a year to prevent build up of dust and overheating of unit Replacing Filters The filter package needs attention when the filter change signal is alarmed and red LED s on the unit are illuminated. A log of filter changes should be maintained by the user. All filters are tested to BS3928. A certificate on conformity for each filter is available on request. It is recommended that a spare set of filters are kept on site to avoid prolonged unit unavailability. Refer to the consumable spares table. Caution To prevent overheating, units should not be run with a blocked filter condition, or with dust obstruction of inlets or outlets. Filter replacement indication The first few filter changes should only apply to the pre-filter. The indication that the Combined or Gas / HEPA filter needs replacing is when the filter alarm signal and LED s (if fitted) do not go off after the pre filter has been changed. Please note that the carbon media within the combined filter or Gas filter is hygroscopic and will absorb moisture from the atmosphere. This is why these filters should be changed every twelve months regardless. The filter change procedure depends on the specific model of extractor. (See layout diagrams below) TB-4012 Page 4 of 10

Filter replacement 35440, 35445, 35460 Isolate the electrical supply to the extractor. Undo the protex clips on either side of the unit and lift the lid or motor section clear of the filter package and place on a safe surface. Remove the filter package from the base of the unit. Vacuum out any dust in the base. (We recommend using a Menda Omega Field or Service Vac). Remove the pre-filter, which may be recessed into the combined filter. (See Figure 4) Replace the exhausted pre filter, or combined filter, or Foam filter as necessary. Place the filter package back into position. Replace the motor section, fasten the protex clips and start up the unit. 35440 35445 35460 Figure 4 TB-4012 Page 5 of 10

35440 System Specifications Capacity: 53 CFM Size: height 15" x depth 10" x width 10" Weight: 15 lbs. Exhauster: Centrifugal fan Rated Output: 60w (65w) Electrical supply: 120V 1ph 60Hz Full Load Current: 0.3A (0.65A) Noise level: 54dB (A) Filters: Pre filter Surface area 0.06 m² Efficiency F7 85% @ 0.8µ Combined filter Surface area 2.0 m² Efficiency H13 99.997% @ 0.3µ Impregnated Carbon Duct Size: 50mm Duct Run: 9.5 feet 35445 System Specifications Capacity: 125 CFM Size: height 15" x depth 10" x width 10" Weight: 22 lbs. Exhauster: Centrifugal fan Rated Output: 140w (95w) Electrical supply: 120V 1ph 60Hz Full Load Current: 1.1A (1.4A) Noise level: 55dB (A) Filters: Pre filter Surface area 0.06 m² Efficiency F7 85% @ 0.8µ Combined filter Surface area 2.0 m² Efficiency H13 99.997% @ 0.3µ Impregnated Carbon Duct Size: 2 x 50mm Duct Run: 16 feet TB-4012 Page 6 of 10

35460 System Specifications Capacity: 320 CFM Size: height 17.5" x depth 14.5" x width 14.5" Weight: 50 lbs. Exhauster: Centrifugal fan Rated Output: 240W (255W) Electrical supply: 120V 1ph 60Hz Full Load Current: 1.8A (3.5A) Noise level: 60dB (A) Filters: Pre filter Efficiency F8 85% @ 0.8µ Gas activated carbon foam Duct Size: 4 x 50mm or 2 x 75mm Duct Run: 19.5 feet The 35460 will run a maximum of six 50mm arms or four 75mm arms and with a maximum duct run of 19.5 feet. Limited Warranty Menda expressly warrants that for a period of three (3) years from the date of purchase, Menda Fume Extraction Units will be free of defects in material (parts) and workmanship (labor). Within the warranty period, the product will be tested, repaired, or replaced at Menda s option, free of charge. Call our Customer Service Department at 909-627-2453 for a Return Material Authorization (RMA) and proper shipping instructions and address. Include a copy of your original packing slip, invoice, or other proof of purchase date. Any unit under warranty should be shipped prepaid to the Menda factory. Warranty repairs will take approximately two weeks. If your unit is out of warranty, call Customer Service at 909-627-2453 for a Return Material Authorization (RMA) and proper shipping instructions and address. Menda will quote repair charges necessary to bring your unit up to factory standards. Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products. Limit of Liability In no event will Menda or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. TB-4012 Page 7 of 10

HEPA FILTER (35451) MATERIAL SAFTEY DATA SHEET SECTION 1 COMPOSITION / INFORMATION ON COMPONENTS QAS NO Constituents Chemical Name Content % PEL & TLV 65997-17-3 Fibre Glass 75-95% 5mg/m3 OSHA breathable dust 10mg/m3 OSHA Total dust 1 fibre/cc (TWA) ACGIH 25038-59-9 Polyester 0-20% 5mg/m3 OSHA breathable dust 9004-34-6 Regenerate cellulose 0-3% 5mg/m3 OSHA breathable dust NA Acrylic latex 3-10% NA SECTION 2 HAZARDS IDENTIFICATION The ingredients in this product are not listed as carcinogens by ACGIH, IARC, NTP, or OSHA. Glass wool fibres; dust of breathable sizes has been classified by NTP as reasonable anticipated to be a carcinogen IARC has classified glass wool fibres as Group 2B, possibly carcinogenic to humans. OSHA has not classified glass wool. Glass wool fibres; dust of breathable sizes has been classified as Group III possibly carcinogenic to human according to the European Directive 97/69/C.E. Pre-existing upper respiratory and lung diseases may be aggravated by dust or loose fibres. Overexposure to loose fibres or dust may cause irritation or soreness in the throat and nose, skin irritation, rash, eye irritation or inflammation, may cause irritation to the gastro-intestinal tract. SECTION 3 FIRST AID MEASURES Eyes: Skin: Ingestion: Inhalation: Do not rub eyes. Flush immediately with large amounts of water for at least 15min. Eyelids should be held away from the eyeball to ensure through rinsing. If irritation persists or foreign body in the eye, get immediate medical attention. Wash area of contact gently with soap and water. Launder contaminated clothing before reuse. Get medical attention if irritation persists. Do not induce vomiting. Get medical attention for substantial ingestions or if symptoms develop. If symptoms develp, remove person from source of exposure to fresh air. Drink water to clear throat. Blow nose to evacuate fibres. Get medical attention if irritation persists. SECTION 4 FIRE FIGHTING MEASURES Flammable Properties: Hazardous Combustion Products: General Hazards: Extinguishing Media: Fire Fighting Equipment As regards toxicity, the gas coming out of the paper due to its small organic binder content does not represent any risk. The organic binder may burn-off at high temperatures, however this material will not support combustion. The packaging as well as the materials around might be flammable. Water spray, Carbon dioxide, Foam, Dry chemical Wear self-contained breathing apparatus when entering in oxygen deficient area. Avoid breathing combustion products from intial burn-off organic binder. SECTION 5 ACCIDENTAL RELEASE MEASURES Pick up large pieces. Use vacuum to clean up any dust. Wet dust with water where sweeping is necessary. Personal saftey and exposure recommendations described elsewhere in this data sheet apply to exposure during clean up of spilled material. TB-4012 Page 8 of 10

GAS FILTER (35452) MATERIAL SAFTEY DATA SHEET SECTION 1 COMPOSITION / INFORMATION ON INGREDIENTS Chemical Characterisation: SECTION 2 HAZARDS IDENTIFICATION This product is an odourless black granule or extruded pellet. Never enter a confined space containing carbon as it will absorb oxygen and asphxiation may result. Prolonged or repeated exposure to dust may cause eye and respiratory tract irritation. SECTION 3 FIRST AID MEASURES Steam Activated Carbon, black, granular impregnated with approx 5-10% wt. Phosphoric acid and Carbamide. Components: CAS number UN number Carbon 7440-44-0 1362 Phosphoric Acid 7664-38-2 1805 Carbamide 57-13-6 Eyes: Skin: Ingestion: Inhalation: Promptly flush with running water for 15 minutes including water under eyelids. Obtain medical attention. Wash affected area well with water. Remove clothing, clean and dry thoroughly before re-use. Get medical help if irritation develops. Give 1 / 2 pint of warm water to drink. Seek medical help urgently. Do not induce vomiting. Remove to fresh air. Get medical help if irritation develops. SECTION 4 FIRE FIGHTING MEASURES Flammable Properties: Hazardous Combustion Products: General Hazards: Extinguishing Media: Fire Fighting Equipment Material will burn in a fire, releasing combustion products of carbon monoxide, carbon dioxide and phosphorus oxide. Other material adsorbed on to the carbon may also be released. Water fog, foam, dry chemical. Self-contained breathing apparatus and full body protective clothing. SECTION 5 ACCIDENTAL RELEASE MEASURES Notify safety personnel for large spills. Avoid generation of dust. Collect solid for recovery or disposal. Personnel involved in clean up need protection against skin and eye contact and inhalation of dust or mist. SECTION 6 HANDLING AND STORAGE Handling: Storage: Follow good handling and housekeeping procedures, avoid spills, accumulation of dust and generation of airborne dust. Avoid prolonged contact with skin and eyes. Avoid inhalation of dust. Wear protective gloves and safety glasses or goggles. Use in a well ventilated area. Store in a sealed container in a clean, dry, well ventilated area away from strong oxidisers, strong acids, ignition sources, combustible materials and heat. SECTION 7 EXPOSURE CONTROLS AND PERSONAL PROTECTION Eye Protection: Skin Protection: Wear safety glasses with side shields, safety goggles or a face shield, especially in dusty conditions. Provide eye wash station nearby. Gloves and overalls should be worn when handling this product. TB-4012 Page 9 of 10

Respiratory Protection: A dust mask meeting CEN or NIOSH regulations should be worn when handling this product. Maximum permissible exposure limit for inert dust: 6mg/m 3. When exceeded, an irritation of respiratory tract is possible. SECTION 8 PHYSICAL AND CHEMICAL PROPERTIES (TYPICAL) Form Solid Colour Black Danger of Explosion Under normal conditions no danger of explosion. In unfavourable conditions may form an explosive dust/air mixture. Bulk Density: Approx 630gl -1 Solubility Insoluble (the acid impregnation is water soluble) ph Value Strong acid/suspension with water forms potassium hydroxide solution Ignition Temperature >350 C Auto-Ignition None SECTION 9 STABILITY AND REACTIVITY Chemical Stability: Conditions to Avoid: Hazardous Decomposition Products: Hazardous Polymerisation: Stable Heat and ignition sources, strong oxidisers and combustible materials. CO, CO 2, phosphorous oxide, ammonia None. SECTION 10 TOXICOLOGICAL INFORMATION No toxological properties SECTION 11 ECOLOGICAL INFORMATION Slightly hazardous SECTION 12 DISPOSAL CONSIDERATIONS In accordance with local regulations. SECTION 13 TRANSPORT INFORMATION Land Transport ADR/RID Class: 8, corrosive substances UN - Number 3244 Maritime Transport IMDG Class: 8, corrosive substances UN - Number 3244 Air Transport IATA Class: 8, corrosive substances UN - Number 3244 SECTION 14 REGULATORY INFORMATION Corrosive solid, activated carbon containing phosphoric acid Hazardous Component R-Phrases S-Phrases Corrosive = C R 36/38 irritates the eyes and skin S 20 when using so not eat or drink S 26 In case of contact with eyes flush careful with water and consult a physician S 45 In case of accident or indisposition consult a physician immediately TB-4012 Page 10 of 10