STRIKE GUARD DELIVERS:

Similar documents
WAVE SEQUENCER DELIVERS:

Nardalert S3 TM Non-Ionizing Radiation Monitor

Architectural and Engineering Specification for a. Flash / Flare

Fiber Optic Cable Fence Disturbance Sensor

Specification for On-Line UPS Battery Monitoring and Data Management System

Across-the-Line SERIES MP300 Combined Manual and Automatic

LaserFOCUS VLF-250 Engineering Specification

WG Buried Cable Perimeter Detection System

Soft Start Series MP700 Solid State, Reduced Voltage

LONE WORKER SAFETY HOW DO YOU PROTECT YOUR LONE WORKERS? EMPLOYEE CHECK-IN SYSTEMS DON T WORK! YOU NEED AN IMMEDIATE NOTIFICATION SYSTEM

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Alarm annunciation, control and communication systems

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

TECHNOLOGY GETS THE JUMP ON MOTHER NATURE.

GasGard 100 Control System

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Variable Frequency Drive SERIES MP800 VFD

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

ECO PDU PE7214/PE7216/PE7324/PE7328

EL-USB-TC Thermocouple Data Logger with USB Interface

Section PERIMETER SECURITY SYSTEMS

AS950 REFRIGERATED SAMPLERS

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

HRX Technical Manual. Version 1.2

Multi-Gas-Controller MGC2

HOBO U30 Remote Monitoring Systems

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Public Safety DAS Annunciator Panel

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Dräger REGARD -1 Control System

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Frequently asked questions: Intelligent Transmitter Series

PTE0705 Electric Fence Monitor

Presented By. BEI Security

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Octalarm-T: the latest in future-proof industrial alarm diallers

DGC-500 DIGITAL GENSET CONTROLLER

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Danfoss gas detection units

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

CHECKFIRE 210 Detection and Actuation System

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

SEE DISCLAIMER ON REVERSE

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

PRODUCT Instruction Manual for Rehabilitation Facilities

NETWORK FIRE ALARM CONTROL PANEL. Features

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Security designed for your lifestyle

EL-OEM-3 OEM Packaged Voltage Data Logger

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Addressable Fire Alarm Control Panel

Danfoss gas detection units

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Omniguard 4: Features

products and services

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

EC-BOS-602/616 AX Security

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Wireless 0-5 Volt Meter Sensor

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

HOW TO SPECIFY A DELPHIAN SYSTEM

Architectural and Engineering Specification for a Real-Time Locating System Flare

PL140 Sump Liquid Sensor-Controller Kit With Local or Remote Notification

AS950 PORTABLE SAMPLERS

EL-USB-1-LCD Temperature Data Logger with LCD

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

LDRA6 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Siemens Building Technologies Landis & Staefa Division. for central units OCI600 / OCI611 / OZW10 / OZW111 / OZW30 / OCI55

ACTIVE INFRARED BARRIER

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Model A1700 Series Annunciator

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Two-Channel Gas Controller

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

LORAIN CIP 4890/48120 DC Power System

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

SS2000 Software Configuration Manual

TrueAlarm Fire Alarm Systems

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

HOBO U14 Data Logger User Manual

TrueAlarm Fire Alarm Systems

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Transcription:

TM Strike Guard employs state-of-the-art technology to address the most demanding lightning safety and equipment protection applications. Designed for critical industrial applications, Strike Guard monitors cloud and cloud-to-ground lightning within a user-set radius and provides contact-closure signaling at user-set lightning activity thresholds. Patented optical signal processing and proprietary optical-coincidence technology prevent false alarms. Strike Guard Sensor data are communicated via lightning-proof fiber-optic cable to an independent Lightning Data Receiver with system status, caution and alarm indicators, relays, and PC compatible output. STRIKE GUARD DELIVERS: Fully automatic alarm triggering with user-set range categories 20 mile detection radius No false alarms! Patented technology Sensor and communication self-test Sensor is battery powered for easy installation Durable fiber-optic communication with connector-less technology Lightning-proof data communication NEMA 4X Sensor enclosure Lightning Data Receiver with battery-back up Optional, Strike View, Windows -based display software Strike Guard Simulation Software for training and testing The proven and patented technology in Strike Guard provides significant improvement over first-generation lightning sensors. Strike Guard enables automated initiation of lightning evacuation plans, data back-up, generator activation, and equipment shutdown procedures with utmost confidence.

LIGHTNING DATA RECEIVER SPECIFICATIONS: INSTALLATION: Wall-mountable with size 10 screws. ENCLOSURE: Type 304 stainless steel. BATTERY: User-replaceable alkaline C-cells. Low battery indicator. COMMUNICATION: Connector-less fiber-optic link for Sensor input and output to PC. Integral Sensor data repeater. EXTERNAL CONTROL: 2 relays, single pole, double throw. 1 A at 120 VAC, UL, CSA approved. LIGHTNING ALARM RANGE SETTINGS: <5 miles, <10 miles or <20 miles. SETTINGS: Lightning alarm range, alarm timeout, and lightning counts for contact-closure signaling. AUDIBLE NOTIFICATION: Alarm Mode, Lightning Flash. EXTERNAL POWER: In-line switching power supply. Input 100-240 VAC, 50/60 Hz. UL, VDE, FCC, CSA, CE. SENSOR SPECIFICATIONS: INSTALLATION: Materials and hardware included for roof-mount. SITE REQUIREMENTS: Minimal siting restrictions. ENCLOSURE: NEMA 4X COMMUNICATION: PMMA fiber-optic, 100 ft cable included. BATTERY: Lithium primary cells, 4-year life minimum. STRIKE VIEW SOFTWARE SPECIFICATIONS: COMPUTER REQUIREMENTS: 64 MB; Pentium I or higher recommended. PLATFORM: Windows 95/98 ME/2000/XP PC INPUT: Strike Guard RS-232 to Fiber-optic Converter provided with 9 socket serial interface. USB adapter cable available. CABLE: PMMA fiber-optic cable. INSTALLATION: CD-ROM. Strike Guard Sensor interfaces to a Lightning Data Receiver and optional Windows -based Strike View Software. The Lightning Data Receiver offers: 1. Audible and visual alarm and system status indicators 2. Full battery back-up (200 hr typical) 3. Relays to interface with sirens and remote-controlled equipment 4. Output for PC to run Strike View Software Strike View Software offers: 1. Lightning Data Receiver-to-PC fiber-optic communication link for RS-232 or USB port 2. Data logging 3. Exclusive countdown timer from last lightning detected 4. Lightning histograms to monitor storm progression Each lightning detection and notification problem presents unique challenges. Let us consult with you to configure a custom solution that meets your needs. Ask us about networked sensors to cover larger areas and multiple locations. Strike Guard is exclusively distributed by: Wxline, LLC 3924 North Calle Casita Tucson, AZ 85718 Call us today to discuss your specific For application more information needs and contact: to locate a representative in your area. Turf Toll Free: Products 1-800.615.0340 - Enfield, CT Int l: ++ 520.615.9999 1-800-243-4355 Fax: 520.615.0030 www.wxline.com Specifications are subject to change. TM

For more information contact: Turf Products - Enfield, CT 1-800-243-4355

For more information contact: Turf PRoducts - Enfield, CT 1-800-243-4355