The Energy Mist System

Similar documents
AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

HYBRID ADIABATIC Cooling System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

100% Outdoor Air Dehumidification Methods

HVAC Water chiller selection and optimisation of operation

Air conditioning 23XRV

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Parilla Thermal Storage Project Case Study. May Page 1 of 11

The SMART COOLING adiabatic precooling panels will reduce up to 30% of your cooling systems energy consumption!

Presented By: John Dolan, P.E.

SECTION I: EXISITNG SYSTEM AND PROPOSED SYSTEMS

Refrigeration System Report March 2017

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Low GWP Refrigerants for Air Conditioning Applications

GEOTHERMAL DESIGN GUIDE

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

Engineered for flexibility and performance

Heat recovery systems - Free hot water by total recovery of the heat rejected by the cooling units

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

PPL Electric Utilities Energy Efficiency and Conservation Program

PRODUCT OVERVIEW. Dehumidifiers

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

Bulletin , March Electric Hot Gas Bypass Valves

Midwest Industrial Initiative Webinar: Industrial Refrigeration

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

TF Series With SECOPAC LS

ENGINEERING. Edition No. 13 October 2002

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

How Much Energy is Really Being Wasted?

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

The impact of water treatment on refrigeration system energy efficiency

Vicot Air Conditioning Co., Ltd. CONTENT

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Water Jet Nozzle to reduce the operation cost in Air Conditioning unit

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Method to test HVAC equipment at part load conditions

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

General HVAC Recommendations

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

PRINCIPLES OF REFRIGERATION ~ CHILLER EFFICIENCY & CONDENSATION by PM Husband

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Energy-Saving Refrigeration Dryers SECOTEC

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

APC APPLICATION NOTE #109

- Murdoch University, Western Australia.

energydesignresources

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz


b.) Technical Information:

Call us today! (800)

Call us today! (800)

Lynergy Comfort Control SCR Electric Heater Application Guide

Energy-Saving Refrigeration Dryers SECOTEC

Data Centre Cooling Solutions

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

R4H4. Product Specifications

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Patent Pending CO 2 OLrac. Blade Server Cooling

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Data Centre Cooling Solutions

THERMAL ICE STORAGE: Application & Design Guide

ASTRALPOOL HEAT PUMP CATALOGUE

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Tube-in-tube heat exchanger Type HE

JCseries EVAPORATIVE CONDENSER. engineering data

Leadership, Innovation, Advanced Technology Synergise Here!

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Daikin VRV Systems Plugin VE2012 User Guide

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Transcritical CO2 Bottle Cooler Development

The Importance of Integrated Design, Commissioning, and Building Tuning: A Grocery Store Case Study

Improving the performance of Air Cooled Chillers, Dry Coolers and Refrigeration Plants

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

ASTRALPOOL HEAT PUMP CATALOGUE

RoofPak Applied Rooftop Systems

Chapter-8 Capacity Control of Refrigeration Systems

Transcription:

The Energy Mist System by Miatech, Inc.

What is an Energy Mist System? A simple, cost-effective method of dramatically improving the upper ambient performance of refrigeration and air- conditioning systems

How Does It Accomplish This? By injecting a cool water mist into the condenser air. This lowers its temperature and allows the condenser to reject more heat.

What Are The Potential Benefits?

Increased Cooling Capacity Because the temperature of the condenser air is reduced through the evaporation of water into the air, the condenser can reject more heat and cooling capacity is increased.

Decreased Peak Demand Because the condenser can reject more heat, head pressures are reduced. As a result, the compressors require less power to run, which reduces peak demand.

Decreased Energy Use (kwh) Since the compressors draw less power and produce more cooling when they run, energy usage (kwh) is reduced.

Extended Compressor Life Since head pressures are lowered, the compressors are taxed less under peak ambient conditions, so compressor life is significantly extended.

Reduced Water and Sewerage Costs When the Energy Mist System replaces water sprinklers that are already being applied to air-cooled condensers, water and sewerage costs are slashed.

Why Is the Energy Mist System Needed? The performance of air-cooled systems is negatively impacted at high ambient temperatures so demand and energy use increase while cooling capacity falls. As condensers age, the coils, fins and fans deteriorate and they become less capable of rejecting heat. Newer refrigerants often run under higher pressures and temperatures, so more condenser capacity is needed.

The Proof: Manufacturer s Performance Data

Traditional i High Ambient Solutions Missing December

Evaporative Condensers and Cooling Towers These work well but they are a difficult, expensive, invasive retrofit. They also require a great deal of maintenance as well as continuous chemical treatment.

Evaporative Pad Systems These work to some extent, t but on horizontal condensers they are difficult to install. Furthermore, water use is high and mold tends to grow on the pads.

Mechanical Subcoolers Although peak ambient capacity is increased, peak demand and kwh usage may both rise.

Lawn Sprinklers Sprinklers are often placed under condensers to increase peak ambient cooling capacity. Since water use is uncontrolled, water and sewerage costs tend to skyrocket.

Note: Each of the traditional high ambient solutions previously listed, other than mechanical subcoolers, involves utilizing water to increase heat rejection. That is because it is a universally accepted solution. The trick, however, is to use the water judiciously.

The Energy Mist Solution

How The Energy Mist System Works Water is fed to the inlet of a positive displacement pump. Upon a signal from a thermostat or energy management system, the pump raises the water pressure to the desired level. The pressurized water then flows through tubing to atomization nozzles located on mist bars placed around the perimeter of the condensing coil. The mist is directed into the incoming condenser air, lowering its temperature and reducing system head pressure. This increases cooling capacity while decreasing peak demand.

How Misting Cools Condenser Air As the water evaporates, latent heat is extracted from the air, thereby lowering its temperature.

Components

Pump Module The heart of the Energy Mist System is the pump module. Manufactured for Latent Energy Solutions by world-renowned Miatech, Inc. of Clackamas, Oregon, these pumping modules are extremely reliable and require very little maintenance.

Mist Bars The patented mist bars deliver a super-fine micro mist. Atomization tips are spaced 9 apart, allowing for maximum coverage. A unique integrated ball check valve tip eliminates dripping and features on/off capability. With no spray nozzles to misdirect and/or break, they provide unparalleled reliability. Integral magnets on the back of the mist bars allow for rapid attachment t to condensers, minimizing i i i installation ti costs.

Adjustable Thermostatic Control By sensing the outside air temperature, the thermostatic control cycles the system on and off as needed, thereby minimizing water and sewerage costs.

Integral Water Meter This tracks water usage, allowing the user to eliminate sewerage charges for the water consumed in the misting process.

Horizontal Condenser Coil Mist bars are placed under the condenser.

Vertical Condenser Coil Mist bars are placed around the condenser coils.

Air-cooled Chiller Mist bars are placed around the vertical coils and below the horizontal coils.

How Energy Savings Are Predicted Latent Energy Solutions has developed a spreadsheet based on ASHRAE bin data. When site-specific conditions are fed into the spreadsheet, it calculates l the baseline kw and kwh, the revised kw and kwh, the energy savings and the water usage.

The Spreadsheet

Service is available through Miatech s Service is available through Miatech s international network of service dealers.