Waste/Multi Oil Boilers from Flexiheat

Similar documents
KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

AIREX 2S WOOD PYROLYSIS SUCKING FAN

Importance of a Draught Regulator

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

TRIOPREX N /08 rev. 2. INSTALLATION, USE AND SERVICING INSTRUCTION (to be kept by the user)

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

DELTA-TE III. Nozzle-mix line burner

INSTALLATION AND OPERATION MANUAL

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

G215 G315 Cast Iron Residential Boilers

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

Mynute Green Condensing Wall-Hung Boilers

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

GAS CONDENSING TECHNOLOGY

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

Type BK 20 BK 30 BK 50

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

DOMESTIC WATER HEATER OIL FIRED

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

Prextherm Rsw High efficiency steel pressurised boilers

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Steam Fundamentals. (in heating & processing applications)

Series 4. Rotary rack oven. For pastry chefs and bakers, Series 4 rotary rack ovens concentrate a range of technology to ensure real benefits:

TECHNICAL DATA MOBILE WASTE INCINERATOR

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Development of Boiler Design

G515/7 Cast Iron Boiler

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

STILE BEAUTY AND TECHNOLOGY

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

G615/11 Cast Iron Boiler

FUEL-FIRED VERTICAL TUBELESS BOILERS

WOOD CHIP HEATING HPK-RA

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Subclass F24H covers heater as such, i.e. the arrangements where the heat is generated.

WOOD CHIP HEATING HPK-RA

Model 601CRD Oil Burner

Oil burners fuel unit with solenoid valve

Air Cross 21 Installation and User Manual

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

ENTROPIE boiler TT100-01

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Heating with log wood

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

TERSEC TERSEC DUO /05 rev.0. INSTALLATION, USE AND SERVICING INSTRUCTION (to be kept by the user)

Light oil burners. One stage operation

We offer ceramic radiant heaters and infra-red radiant tubes.

Intelligent Heating for Your Home

Bosch Uni 7000F Cast Iron Hot Water Boiler

Burner Comparisons. Typical Competitor s Burner

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

RODI DUAL RODI DUAL HR

Forced draught gas burner

Oil burners Brûleurs fioul Stookoliebranders

Heat Exchanger Module for Industrial Applications

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

CHAPTER 10 STEAM AND HOT WATER BOILERS

Heating with Wood. Part 2

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Technical Specification

G315/6 Cast Iron Boiler

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Max-3 Steel Shell Boiler

Fuel-Fired Vertical Tubeless Boilers

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

NEXT GENERATION OF ELECTRICAL LADLE HEATERS: A CASE STORY. Marcus Andersson. Sandvik Heating Technology, Hallstahammar, Sweden ABSTRACT

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

OIL AND GAS INDUSTRY

LEAD RECYCLING PLANT. Battery Machine Manufacturers: Since 1989

G315/5 Cast Iron Boiler

The iqe Boiler Range. Combination and System T Boilers.

Boiler Technical Specifications (2013)

"HC" AIRFLO. In-duct firing line burner

Industrial furnaces and associated processing equipment Safety. Part 2: Combustion and fuel handling systems

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

pressurejetrange Buccaneer GTE, Falcon GTS, Harrier GTS, Viceroy GTS, Viscount GTS, Vanguard L Pressure jet boilers kW

HI-TECH COMPONENTS. the world of heat. Circond Stainless Steel Condensing Heat Exchanger VALMEX GROUP. Heat exchangers - Cold Pressing

Oil burners fuel unit with solenoid valve

New generation heat exchanger improves industrial energy efficiency

USER S INFORMATION MANUAL

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Transcription:

Waste/Multi Oil Boilers from Flexiheat At a time of rising fuel costs, the Flexiheat FMOB universal/waste oil boiler range, which can burn nearly all vegetable, animal, conventional and waste oil, will save you money. It provides you with flexibility in choosing your preferred fuel source

FMOB Warm water steel boiler for temperature up to 9 C Total radiation, dry, anti-condensate combustion chamber Hinged door with reversible opening Output from 26 to 233 kw DIMENSIONS F G H TECHNICAL DATA Models NOMINAL OUTPUT NOMINAL INPUT BOILER CONTENT T1 T3 T2 T WATER SIDE PRESSURE LOSSES * SMOKE SIDE PRESSURE LOSSES MAX. WORKING PRESSURE FLOW/RETURN CONNECTIONS DIMENSIONS DRY WEIGHT A B C D kw kw l m c.a. m mc.a. bar ISO 7/1 kkgg D C 78 30 33 0 0.09 2.8 Rp 1 70 60 77 80 10 P 2 Steel boiler for pressure jet gas/oil burner Reversed flame boiler range for pressure jet burners, suitable for small/middle size installations, where the traditional sturdiness and duration of the steel are favoured. Dry combustion chamber with anticondensate patent The combustion chamber walls that lean out to the flame are not directly cooled by the water because covered by a series of triangular fins, welded 3 8 67 0.12 Rp 11/ 660 730 81 630 210 A 2 7 67 0.1 3.7 Rp 11/ 660 730 81 630 210 E 00 FMOB26C FMOB30C FMOBC FMOB2C 26 28 8 0.09 2. Rp 1 70 60 67 80 120 1 T B Key: 1 - Panel board 2 - Flame sight glass 3 - Boiler basement (up on request) - Cleaning opening T1 - Central heating flow T2 - Central heating return T3 - Chimney connection T - Boiler drain T - Burner connection to each other and to the furnace cylinder so that to form a dry combustion chamber. This improves notably the combustion in comparison to that one obtained in the wet combustion chamber, reducing the fouling of the heat exchange surfaces and the risks of acidic condensate formation, responsible of the corrosion. The bottom of the combustion chamber, constituted by a refractory concrete casting, contributes to complete the raising of the combustion temperature, improving it. Anti-condensate smoke way The smokes continue their run within boiler in the channels drawn between the triangular baffles and the furnace cylinder in contact with the water. The particular processing of the baffles with interrupting joints, annuls the thermal expansions and, thanks to the wide surface that is heated, it subsequently reduces the condensation phenomena (patented system). Stainless steel turbulators Adjustable inside the smoke channels, they optimize the heat exchange and stabilize the counter pressure for the regular operation of the burner. (*) Pressure losses for a flow rate corresponding to a t of 1 K

* - For the model FHMOB233 the connections T1-T2 are flanged. The dimension H is applicable only to the model FMOB233 fig. 2 1 Panel board 2 Burner connecting plate 3 Cleaning door Sight glass T1 C.H. flow T2 C.H. return T3 Flue connection T Burner axis T Boiler drain MODAL Type FMOB6C FMOB76C FMOB93C (6).000 (76) 6.000 (93) 80.000 (10) FMOB10C 90.000 FMOB116C (116) 100.000 (10) FMOB10 FMOB163 FMOB186 Output (kw) kcal/h 120.000 (163) 10.000 (186) Input (kw) kcal/h (71) 61.000 (8) 72.000 (102) 88.000 (11) 99.000 (128) 110.000 (1) 133.000 () 1.000 (206) 160.000 177.000 (233) (28) FMOB233.000 222.000 A 690 690 690 860 B 722 722 722 937 C 990 990 990 120 120 120 138 138 137 DIMENSIONS D E 30 30 30 30 30 30 30 30 21 F 80 80 80 00 00 00 00 00 80 G 11 11 11 16 H 182 T1 - T2 ISO 7/1 UNI 2278 PN16 Rp 1½ Rp 1½ Rp 1½ DN 6 CONNECTIONS T3 Ø 20 T Ø T ISO 7/1 Combustion chamber dimensions Øi x Lg 330 x 670 330 x670 330 x 670 390 x 80 390 x 80 390 x 80 390 x 1030 390 x 1030 70 x 1070 Boiler capacity liters 86 86 86 126 126 126 11 11 203 Water side press. loss(*) m w.c. 0,10 0,13 0,16 0,10 0,10 0,1 0,20 0,2 0,22 Smoke Max. side allow. press. working losses pressure w.c. bar 1, 1,8 2, 3 3 8 1 18 Weight kg 19 19 19 280 280 280 318 318 20

Day Tank With all our heaters we can supply a 100L day tank. This tank comes complete with a pump, motor and fuel filter as standard. This day tank needs to be situated next to the heater. The main advantages of the tank are;- Via float suction it picks up the cleanest oil It picks up the latent heat from being in close proximately to the heater resulting in the oil being semipreheated prior to entering the burner. The tank also has a drainage point at the bottom allowing easy drainage of any water/contaminants from the oil. This results in the oil being semi-preheated prior to entering the burner. ** You can run your bulk storage tank supply to this day tank but you will need a float switch and solenoid valve to prevent oil overflow due to gravity

Flue gases cannot rise in a horizontal stack and bends also restrict their movement. If flue bends are used then we recoend bends instead of 90 and a gradual sloping stack