Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Similar documents
TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Centrum stavebního inženýrství a.s.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Reaction to fire test

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Centrum stavebního inženýrství a.s.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional Reaction to Fire Classification Report

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION REPORT

CE marking of fire-resistant doors the right way!

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

Classification Report

DELTA Classification Report

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Form: KSD-100:10 Page 1 of 3

Report VNLF Test Report

Additional reaction to fire classification report No H

Analysis Report

Abrasion Resistance of Fluoropolymer and polyester Coatings

Classification report

Test Report: ICL/CR15/11/087

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

BS EN ISO : 2010

ISO INTERNATIONAL STANDARD

Reaction to fire classification report No C-rev.1

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

PRESS RELEASE

~~oeti. Report VN71 O Classification Report. Reference

BS EN ISO : 2010

Reaction to fire classification report No C

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

~,oeti. Report VN Classification Report. Reference

Review Fire Test Report

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

EFFISUS BRAZE MEMBRANE

BS EN ISO : 2010

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Report VNNF Test Report

BCTC CARPET TECHNICAL CENTRE

YOUR GUIDE TO UNDERSTANDING CPR

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Üntel is ready for CPR

Procedure for the Approval of New Fire Detection and Alarm Technologies

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

CERTIFICATE OF APPROVAL No ME 5085

Test Report No: ICL/H17/7967

EC CERTIFICATE OF CONFORMITY 0432 CPD 0018

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Performance Specifications LSF LIFT-SMOKE-FREE

FAÇADE FIRE TESTS Towards a new European standard method

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

European Technical Assessment. ETA-17/0624 of 8 September English translation prepared by DIBt - Original version in German language

Approved Sound Proofed Systems

European Technical Assessment. ETA-05/0069 of 3 July English translation prepared by DIBt - Original version in German language.

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Notice. Approval number: Z Scope of validity By: 08 January 2013 to: 01 November 2017

FUNDERMAX GMBH FIRE TEST REPORT

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

European Technical Assessment. ETA-12/0208 of 26 May English translation prepared by DIBt - Original version in German language.

Development of a European approach to assess the fire performance of facades

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

Analysis Report

BS EN : 2001 & IEC :2000


EC-Type Examination (Module B) Certificate. A.1/3.11 b "B" dass divisions, fire integrity

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

FIRST-CLASS IN TRAINS

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

NON-FLAMMABLE WALL COVERING SYSTEM FOR INNOVATIVE FIRE PROTECTION

Z from: 1 April 2015

European Technical ETA-10/0305 Assessment of 6 December 2017 General Part

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

6915 Highway 225, Deer Park, TX 77536

TEMPORARY IMMERSION AND DUST TEST REPORT

New European Cable Testing and Classification

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Smoke and heat control systems - Part 10: Power supplies EN Classification according to operational and environmental class

Report Test Report

Transcription:

Classification Report Reaction to fire of building elements 10-001641-KB02-K06-01-e-01 Translation of Classification report 10-001641- KB02-K06-01-de-01 dated 16. May 2011 Client Deventer Profielen CV Voorerf 75 NL-4824 GM Breda Basis DIN EN 13501-1:2007 Fire classification of construction products and building elements Part 1: Classification using test data from reaction to fire tests Notified Body Notified Body No. 0757 Issue 1 ift Rosenheim GmbH Theodor-Gietl-Str. 7-9 D-83026 Rosenheim Object elastic sealing profiles from silicone Designation product family "DS" Instruction of use This classification report defines the resistance to fire classification assigned to element in accordance with product name in accordance with the procedure given in EN 13501-1. This classification document doesn't represent type approval or certification of the product. Validity The named data and results relate exclusively to tested and described specimen. Notes on publication The ift-guidance Sheet "Conditions and Guidance for the Use of ift-test Documents" applies. This classification report may not be used in extracts or reproduced in extracts. Classification Classification of reaction to fire DIN EN 13501-1:2007 Class E Content The report comprises a total of 6 pages 1 Introduction 2 Details of classified product 3 Test reports / extended application 4 Classification and field of application 5 Limitations ift Rosenheim GmbH 11. July 2011 Volker Müller, Dipl.-Ing. (FH) Head of Testing Department Fire safety Mathias Rauh, Dipl.-Ing. (FH) Operating Product Officer Building Components 5 3 7 / 9 0-9 0

Page 2 of 6 1 Introduction This classification report defines the resistance to fire classification assigned to element product family "DS" in accordance with the procedures given in DIN EN 13501-1:2007. 2 Details of classified product 2.1 General For this building element product family "DS" no product standard has been published 1. 2.2 Description The building elements of product family "DS" will described following or in the reports, which are taken in 3.1 to prove for the classification. Product description: Rollover- and door sealing from silicone. 3 Test reports and test results in support of this classification The following test reports, test results and evaluations will be submitted in support of this classification. 3.1 Test reports Details of the test reports will be listed here if necessary. Table 1 Building element: product family "DS" Test laboratory Client Test Report No. Test method ift Rosenheim Deventer Profielen CV 10-001641-PB01-K06-01-de-01 DIN EN ISO Notified Body: 0757 NL-4824 GM Breda Date: 16. May 2011 11925-2 1 specified by client

Page 3 of 6 3.2 Test results Table 2 Test results: elastic sealing profiles from silicone Building element: product family "DS" Results Test method and number Parameter Number of tests a Continuous Parameter - average (m) Compliance Parameter DIN EN ISO 11925-2 F s 150 mm 44 ( - ) Y 15 s surface exposure * flaming droplets / particles 44 ( - ) N 15 s F s 150 mm 44 ( - ) Y edge exposure * Note: flaming droplets / particles a ) applies not for extended field of application *) as required to the end use application of the prod uct ( - ) not applicable 44 ( - ) Y 4 Classification and field of application 4.1 Reference of classification This classification has been carried out in accordance with DIN EN 13501-1:2007. 4.2 Classification The building elements of product family "DS" in relation to their reaction to fire behaviour will be classified: E The additional classification in relation to smoke production is: - - The additional classification in relation to flaming droplets / particles is: - -

Page 4 of 6 The format of the reaction to fire classification for construction products is: Table 3 Classification of the reaction to fire according to DIN EN 13501-1:2007: Fire behaviour Smoke production Flaming droplets E - - - - Classification of reaction to fire: Class E The additional classification as to smoke production is inapplicable. The additional classification as to flaming droplets / particles is inapplicable. 4.3 Field of application This classification is valid for the following product parameters: For elastic sealing profiles from silicone of product family "DS", see annex 1 For composition of silicone according to test report ift Rosenheim GmbH 10-001641-PB01-K06-01-de-01 For named sealing profiles of product family with a density of approx. 1.15 g/cm³ The elastic sealing profiles from silicone shall be conformed to the deposited colours see annex 1. The elastic sealing profiles from silicone shall be conformed in the deposited dimensions, geometries and designs see test report ift Rosenheim GmbH 10-001641-PB01-K06-01-de-01. The classification is valid for the following end use conditions: The surface of sealing profiles shall be left uncoated respectively shall not be covered by a cover or any kind. The elastic sealing profiles from silicone must be installed in appropriate carrier profiles.

Page 5 of 6 5 Limitations 5.1 General The composition shall be met the composition deposited at ift Rosenheim. In composition with other building materials, subsurface or coatings other then mentioned in section 4.3, the reaction to fire may be influenced so bad that the classification in section 4.2 isn't longer valid. The reaction to fire in those cases has to be proofed separately. 5.2 Warning This document is no type approval or product certification. It doesn't replace an approval according to building code ("Landesbauordnung") where necessary. ift Rosenheim 11. July 2011

Page 6 of 6 Annex 1: product family "DS" Article report No. Article numbers Colours 1 DS112a, DS155a, DS185a, DS6922a, DS6955a, DS6988, DS6577a 2 DS9040 Red Black and white