This label warns for risk of electrical shock when failing to observe.

Similar documents
Operation Guide for Hendor Pumps & Filters. 1. Introduction

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Food Waste Disposer Instruction Manual

PENGUIN SERIES HSC PUMPS INTRODUCTION

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

LC Series - Light Commercial Pump Station Installation and Operation Manual

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

OWNERS GUIDE TO INSTALLATION AND OPERATION

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

SELF-PRIMING JET PUMPS

INSTRUCTION AND REPAIR MANUAL

568X, 587X, 588X Series

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Chemical Motor Pump Unit BN

7165 Dust Collector Owner s Manual

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

APW PSI PRESSURE WASHER

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL

NON-SUBMERSIBLE WATER PUMP

Installation Instructions

SuperKlean Washdown Products

DUST EXTRACTOR MODEL No: CDE1000

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

CHAMPION PUMP OWNER S MANUAL

569, 570, 571, 572 Series

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

5HP CYCLONE DUST COLLECTOR MANUAL

SUBMERSIBLE DIRTY WATER PUMP

Tempest TP420/180 Electric Pressure Washer

Elite Primer Baldor Series External Pond Pump

Installation Instructions

SPECIFICATIONS FEATURES

Installation Instructions

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

Manual / Handbuch Spare parts list / Ersatzteilliste

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

569, 570, 571, 572 Series

Installation Instructions

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

QUIETFLO OWNER S MANUAL

English CNA-CNB. Centrifugal fans Installation and maintenance

SMF PUMP OWNER S MANUAL

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

LIMITED LIFETIME WARRANTY

Installation Instructions

SAM TURBO INDUSTRY LIMITED

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

Installation Instructions

Installation of Glass Lined Equipment

Mechanical seals external, single or double, to DIN EN 12756

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

CombiBloc Close-coupled centrifugal pumps

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

293 Wright Street Delavan, Wisconsin U.S.A BERKELEY Mississauga, Ont., Canada PUMP. 1994, Sta-Rite Industries, Inc.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Installation Instructions

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

Installation guide PRO3-VAQ. Before installing read this guide first

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Installation guide COMBI. Before installing read this guide first

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation & Operating Guide

Electric Pressure Washer

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Installation Guide COMBI. Before installing read this guide first

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

IEC- Direct-driven radial fans with IEC-Standardmotor

Installation Manual PS-225 & PS-275

Transcription:

MANUAL horizontal centrifugal pumps MB series ic drive SB series mechanical seal 1. Introduction 2. Safety precautions 3. Receipt 4. Installation / Operation and Maintenance 4.1 Installation 4.2 Operation and maintenance 4.3 MB series (Magnetic drive pumps) 4.4 SB series (Mechanical seal pumps) 5. EC declaration 6. Exploded view and Parts list 1. Introduction Thank you for choosing a Bofil product. Before starting to use this product we strongly recommend to read this owner s manual thoroughly and to follow instructions as closely as possible. In this way your product will function properly for years to come. This owner s manual contains all obligatory safety precautions. The manual should be put at disposal of the end-user of this product and should be present at site in order to allow operator and maintenance crew to use it. 2. Safety precautions The presented symbols are safety alert symbols. Be alert to potential personal injury in case symbols on the product or in this manual are shown. This label warns for risk of electrical shock when failing to observe. DANGER! WARNING This label warns about hazards that can cause personal injury, death or major property damage if ignored. Keep in mind that the product can contain chemical liquids. Carefully read and follow all safety instructions in the manual and on the pump. Keep safety labels in good condition. Replace missing or damaged safety labels. BOFIL - - 1 - Info 2011689/R0

2.1 Installation Pumps and filters should be connected in the prescribed way. The user always has to consider personal safety and health for himself as well as his direct vicinity. I 3-phase r single phase W2 U2 V2 W2 U2 V2 U1 V1 W1 U1 V1 W1 N L L1 L2 L3 L1 L2 L3 2.2 Electrical 1. Only qualified electricians are allowed to connect pumps according to local regulations of the power supplier. 2. Grounding of the motor should be applied first; failure to ground can cause severe or fatal shock. Do not ground to gas supply lines. 3. Before connecting the motor check corresponding voltage of motor and power supply. Incorrect connection can cause fire or serious damage to the motor and voids warranty. See wiring diagram. 4. Avoid unexpected or accidental starting of the motor by disconnecting and locking out power supply. 5. In case of repair and maintenance disconnect and lock out power supply. 6. Do not point a jet of water at the motor to avoid personal injury (risk of electrical shock). 7. Check wiring dimensions according to the power of the motor. 8. Check fuses on the power supply connection. 9. Thermal overload switch should be used on the connection to the pump. The current overload is adjusted to the value of the motor name plate including +10%. 10. Do avoid damage to the cord line by not hoisting the pump by the cord line and be sure the cord line is not jammed; avoid sharp edges. 11. General rule for Hendor pump shaft rotation: Always run clockwise (CW), looking at cooling fan side. Direction of rotation is also indicated on the motor by arrow. 2.3 Checking direction of rotation! Vertical pumps: Always check direction of rotation outside the liquid. Horizontal pumps: Always check the direction of rotation flooded with liquid. Briefly switching on the power will show direction of rotation, looking at cooling fan side. Ignoring these recommendations will damage the pump severely. 2.4 Plumbing! 1. Connections to the pump and filter should be provided with reliable, persistent materials. 2. Where hoses are used, take care of correct hose clamps. 3. Use the right O-rings for connections. 4. Pipes and hoses should be internally cleared of any obstructions. 5. Check tightness of connections before starting up. 6. Thermoplastic components will not tolerate any plumbing stress. 7. Plumbing should be properly aligned and supported to prevent distortion and damage of parts. 8. Leave enough space for easy access and/or maintenance. 9. Keep position of pump away from any heaters or heater coils. 10. Pumps and filters should be mounted on a sturdy base. 3. Receipt At receipt of the product the identity of the product (by checking name plate data), the completeness of delivery as well as absence of visible damage should be ascertained. The end-user or his representative must ascertain the match of material specification and specific liquid used. Any problems arising from these checks should be made in writing and preferably signed by the forwarding agent as evidence. BOFIL - - 2 - Info 2011689/R0

4. Installation / Operation and Maintenance 4.1 Installation Horizontal ic drive and seal pumps are very sensitive to suction conditions. Many pump problems are caused by poor suction conditions. The bigger the pump and the higher the temperature, the more important the general hydraulic guidelines should be applied. Always try to respect the basic rules for liquid velocity v (m/s). We recommend for Suction side v = 1-2 m/s; Discharge side v = 1,5-3 m/s Flow Inner pipe diameter (mm) l/h 15 20 25 32 40 50 65 80 100 Velocity (m/s) at given flow (l/h) 1000 1,57 0,88 0,57 2000 3,15 1,77 1,13 0,69 4000 6,29 3,54 2,26 1,38 0,88 6000 5,31 3,4 2,07 1,33 8000 4,53 2,76 1,77 1,13 10000 5,66 3,46 2,21 1,42 0,84 15000 5,18 3,32 2,12 1,26 0,83 20000 6,91 4,42 2,83 1,68 1,11 30000 10,4 6,63 4,25 2,51 1,66 1,1 40000 8,85 5,66 3,35 2,21 1,4 Golden rules for proper pipe work 1. Keep suction pipe work as short as possible. 2. Increase pipe size on suction side by at least one pipe diameter for longer suction pipe and/or higher temperature. 3. Use eccentric adaptors at varying diameters to prevent air pockets. 4. Avoid elbows, bends and fittings at suction side. When unavoidable keep fittings at a distance of 10 times pipe diameter away from pump inlet. 5. Pipe work should slope up towards pump to prevent air pockets. 6. Pipe work should be completely leak free. 7. Support pipe work near to pump to prevent stress on plumbing. 8. Allow sufficient liquid level to prevent air intake on suction side. 9. Use generously oversized strainer in case of foreign particles. 10. Use siphon breaker when priming over top of tank. 11. Never throttle pump on suction side. 12. In case of doubt consult Hendor for proper sizing and NPSH calculation. 4.2 Operation and maintenance Magnetic drive pumps. How it works? Driver (motor) and impeller (driven) are physically separated by a shell. Pump part (wet end) is completely sealed. Power transmission is established by ic force between *motor shaft and impeller. Bearings are lubricated and cooled by liquid itself. Mechanical seal pumps. How it works? Impeller is directly attached to the motor shaft by shaft coupling. Mechanical seal on pump shaft prevents liquid from coming out. Mechanical seal is lubricated and cooled by liquid itself. These type of pumps are not self priming and not designed to run dry. Optional priming chambers and dry run protection devices are available. Initial start-up 1. Check for direction of rotation before start-up by shortly switching on/off. Priming instructions at flooded suction: 2. Open all valves on suction and discharge side. 3. At start up the pump always should be flooded with liquid to prevent any damage on s. 4. These type of pumps are not self priming. Therefore liquid level in the bath should be ample above entrance level of the pump. 5. Start the pump when no air remains in the pump. 6. When pumping liquid with higher density than water, start up with almost closed discharge valve to reduce power consumption. Priming instructions at non flooded suction: 2. Ensure entrance of suction pipe is in liquid. 3. Slowly fill pump casing and suction pipe. Use discharge connection to fill. 4. Check if pump is free of air. 5. Close discharge valve and start the pump. 6. Wait until pump is building up pressure, and slowly open discharge valve. Restart after power failure: Check if the pump is able to prime again. Suction pipe and pump should be filled. BOFIL - - 3 - Info 2011689/R0

4.3 Magnetic drive pumps (MB series) General precautions prior to dismantling - always drain liquid from pump. - disconnect all necessary electric cables or use switch on pump. - disconnect suction and discharge piping (watch spilling liquid). - do work on a clean bench. When ordering Bofil parts always quote Pump Type and Serial Number. Dismantling - remove bolts from pump casing; take casing off. - carefully take out impeller and impeller shell; mind strong ic forces. Replacing worn or damaged wet end parts - complete impeller should be exchanged in case s show any damage. - exchange ceramic shaft when surface shows any damage. General description of dismounting the drive - remove the bracket from electric motor. - loosen both hex. screws. - by means of levers drive down the shaft; mind strong ic forces. - check for remaining metal particles on the s. General description of mounting the drive - slightly grease the shaft. - replace the drive by hand onto shaft, watching position of the keyhole. - ensure the drive is driven down the shaft until end is reached. - in case a hammer is used to drive the do not damage motor s. - secure drive by tightening both hex screws. - replace bracket onto electric motor. Assembly - take isolation shell together with ceramic shaft, bushing and O-ring. - put impeller into shell. - mind position of collar of pump type MB40 and MB50. - put casing onto shell in order to close wet end. - carefully place wet end complete onto bracket; mind strong ic forces. - fit all bolts and tighten them. After assembly always check for free rotation of parts by hand. Verify direction of rotation at start up as indicated by arrow on the pump and motor. BOFIL - - 4 - Info 2011689/R0

4.4 Mechanical seal pumps (SB series) General precautions prior to dismantling - always drain liquid from pump. - disconnect electric cables or use switch on pump. - disconnect suction and discharge piping. - do work on a clean bench. When ordering Bofil parts always quote pump type and serial number. Dismantling - remove bolts from pump casing. - take off pump casing. - unscrew locking nut from impeller (clockwise). - take off impeller from shaft (mind key and seal parts). - remove key from shaft. Replacing worn or damaged parts Type SB95 - carefully remove back cover of pump. - carefully take off ceramic bushing from shaft. - remove static seal ring out of back cover. - always renew O-rings and seal parts. Type SB110 / SB120 / SB130 / SB140 / SB150 / SB155 / SB160 / SB170 - carefully remove bellow seal from shaft. - carefully remove back cover of pump. - remove static seal ring out of back cover. - always renew O-rings and seal parts. Assembly - carefully replace new seal ring and O-rings. - put back cover onto pump. - carefully replace new rotating seal parts. - put key in keyhole of shaft. - put impeller onto shaft (mind position of key). - put locking nut on top of impeller (mind new O-ring). - firmly tighten nut, anti-clockwise (pre-load onto seal). - put pump casing onto pump and fit bolts. - tighten all bolts. Check for free rotation by turning cooling fan by hand. Prior to operation of the pump check direction of rotation as indicated by arrow on the pump and motor. Testing the rotation has to be done flooded with liquid. 5. EC-Declaration of conformity Manufacturer: Hendor Pompen BV Address: P.O. box 9 5530 AA Bladel The Netherlands Herewith we declare, that the product: - is in conformity with the provisions of the Machinery Directive, as amended, and with national implementing legislation (Directive 2006/42/EC) - is in conformity with the provisions of the following other EC directives: Low voltage directive (Directive 2006/95/EC) Confirmed at Bladel Signature Technical Director H.F.G. Bohncke BOFIL - - 5 - Info 2011689/R0

Type MB4 / MB6 / MB10 - PP/PVDF Pump MB4 MB6 MB10 Motor flange B3 - B5 kw Pump MB4 MB6 MB10

Type MB15 / MB31 / MB40 - PP/PVDF Pump MB15 MB15 MB31 MB31 MB40 MB40 Motor flange B3 - B5 kw Pump MB15 MB31 MB40

Type MB50 - PP/PVDF Pump MB50 MB50 Motor flange B5 kw Pump MB50

Mechanical seal pumps Series SB - PP/PVDF SB95 SB110 SB120 SB130 SB140 SB150 SB155 SB160 SB170 SB95 SB110 SB120 SB130 SB140 SB150 SB155 SB160 SB170

Type MB4 - PP/PVDF Description Washers Nut Front O-Ring Static Pumpshaft static rear Material Impeller Internal impeller Rear External Bracket

Type MB6 / MB10 - PP/PVDF Description Washers Nut Front O-Ring Static Pumpshaft static rear Material Impeller Internal impeller Rear External Bracket

Type MB15 / MB31 - PP/PVDF Description Washers Nut Front O-Ring Static Pumpshaft static rear Material Impeller Internal impeller Rear External Bracket

Type MB40 / MB50 - PP/PVDF Description Washers Nut Front O-Ring Static Pumpshaft static rear Material Impeller Internal impeller Rear External Bracket Bearing collar