HVAC for Raters & Inspectors

Similar documents
Consumer Features & Benefits of Energy Efficient Products

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Supplement A- Improving Forced Air Heating Systems

Managing HVAC in High Performance Buildings

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Ventilation in Humid Climates: Data from Field Experiments

b.) Technical Information:

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

TR Series - The Ultimate ERV

ENERGY STAR Qualified Homes

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Put the V back in HVAC

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

FirstEnergy Program Overview

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Applying ducted, split-ductless systems. in High-Performance Homes

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Ventilation Techniques. Topic 5 - Audio 53

Effects of Kitchen Ventilation on Residential Dwellings

The ultimate fresh air solution.

Model 1750A/ 1770A Dehumidifier Installation Instructions

CHAPTER 4. HVAC DELIVERY SYSTEMS

Dehumidifying with Dedicated Outdoor Air

Spray Polyurethane Foam and Open-Combustion Appliances

Residential HVAC System Design

Indoor Air Quality Product Brochure.

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

How to Take Basic Readings to Show Energy Efficiency

Basic Building Science insights for Spray Foam, HVAC and Moisture

Desiccant Dehumidifier

Zoning System Design Manual

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Safety and Installation Instructions Model 1700

Choosing Heating and Cooling Systems

Tech to Tech May 07 HRV s & ERV s

2009 IECC Commercial Mechanical Requirements

In accordance with the Department of Labor and Industry s statute , Subd. 11,

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Indoor Air Quality Product Brochure.

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

THE ULTIMATE ROOFTOP SOLUTION

The Housing Assistance Council is a national nonprofit organization that helps build homes and communities

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

A Glossary of HVAC Terms

Suggested Retail Price: $300

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

wattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

ENERGY STAR v3.0 HVAC Checklists

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

LARGE CAPACITY HEATERS

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Because all SPF-insulated homes are very tightly constructed,

Equipment Specifications and Required Information Quantity Rebate

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

SAFETY AND INSTALLATION MANUAL MODEL 8100

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

ACCA Manual J Load Calculations

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

RESNET HERS Rater Sample Test Questions 2

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

MANUAL J/S Summary One summary sheet for each system

RoofPak Applied Rooftop Systems

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Tuning up ventilation systems

Buildings that Connect People to Nature. Heating/Cooling/Ventilation Strategy. Create an efficient building envelope.

Keeping the Heat In 9 Operating your house

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Residential Heat & Energy Recovery

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Home WHOLE-HOME COMFORT SOLUTIONS. Bringing balance. Creating comfort.

Uniform Dwelling Code 2017 Updates SPS 323

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

Transcription:

HVAC for Raters & Inspectors A Practical Overview of HVAC Impacts On Home Performance With Useful Take-Away Tools Presenter: David Slater 2010 Stream Residential LLC. All Rights Reserved. February 23, 2010

Topics 1. HVAC System Types & Fuels 2. HVAC Design Process & Load Calculations Overview 3. Duct Size Guidelines 4. Airflow, Variable Speed Blowers & Zoning 5. Combustion Venting & Carbon Monoxide Safety 6. Common Conditions For Fungal (Mold) Growth 7. Recognizing Great HVAC Systems 8. Particulate Filtration 9. Fresh Air Ventilation 10. Dehumidification

Please consult a licensed professional HVAC contractor for repairs, alterations and installations requiring licensure in that state. Sub-system level diagnostics such as refrigerant pressures, temperatures, compressor current, etc. are useful in assessing performance or diagnostic issues and typically best performed by a certified HVAC technician.

Residential System Types & Fuels Configurations: 1) Split systems 2) Packaged units ODU Either configuration may be Gas furnace & AC, heat pump, or dual fuel ( hybrid ). Splits may have oil boiler with hydronic or forced air distribution.

Residential System Types & Fuels Furnaces vs. Heat Pump Air Handlers (AHU s) Furnaces have blower near inlet most air leaks blow out. Air Handlers have blower nearer to outlet most air leaks suck air in! Air Handler Unit (AHU) Furnace and Evaporator Coils

Residential System Types & Fuels Furnace and air handler models are designed for specific orientations which may include upflow, downflow, left, right. Many newer popular furnace models have multiple stages of heating. Some now are modulating. Higher end AC s (ODU) have two stage compressors, and some now are variable speed. Different thermostats must have multi-stage capability to suit. ODU label model numbers contain compressor size info as a multiple of 6. Since there s 12,000 BTUH per Ton of cooling, 6 represents a 0.5 Ton. E.g. TWR036A1000 is 3 Tons. Furnace/Boiler model numbers contain BTU/Hr inputs. E.g. TUD080A1000 is 80,000 BTUH input.

Residential System Types & Fuels Gas Furnace Generations 1. Natural Draft Metal flue pipe, large slot for incoming combustion air under pipe. Upflow configuration.

Residential System Types & Fuels Gas Furnace Generations 2. 75% Induced Furnaces Inducer fan on outside of furnace cabinet. 75% AFUE Metal flue pipe.

Residential System Types & Fuels Furnace Types (By Generation) 3. 80% Generation. Split furnaces are typically 86% AFUE. Inducer fan and metal flue pipe. 4. 90% Generation (90 98%). A.K.A. condensing furnaces. These make water condensate during heating operation. Special precautions required for cold ambient unit locations. PVC flue pipe.

Residential System Types & Fuels Mini-Splits ( ductless ) units offer advantages in the proper application, such as larger open spaces, additions, sun rooms, etc. Most are variable speed with many other features.

HVAC Design & Installation Process Obtain House Info: Dimensions, Plans, Solar Orientation, etc. Manual T Register/Grille Selection Size: Manual J Load Calculation (By Zone) Generate Parts Lists, Job Plans, Work Orders Manual S Equipment Selection Install & Test (System Level) Manual D Duct Design Balance Airflows Room to Room

Anatomy of a Load Calculation Indoor target (design) temperatures can make an enormous difference in the resulting size of system. Should be 68 or 70 F heating, 75 F cooling, 50 or 55% RH summer. Heating, sensible cooling and latent cooling (moisture removal) must all be satisfied in selecting equipment. Critical inputs into Manual J Load Calculation: Climate use ACCA/ASHRAE table values Duct system location, sealing and insulation levels Solar gain Window construction type and size

Anatomy of a Load Calculation Other inputs into Manual J Load Calculation: Envelope insulation and infiltration. Consider impact of holes in thermal or air barriers fix the envelope! Above grade vs. below grade walls Occupant window treatments, behaviour Architecture (e.g. open cathedral ceiling up to second floor) Field installation & problem solving experience usually improves the efficacy of the designer s calculations. Conversely, a load calculation s input numbers can be manipulated to produce a range of resulting sizes.

Equipment Selection Equipment is often selected as deliberately oversized for one or more required load sizes (heating, sensible, latent), usually due to limitations in equipment availability. Example: very few if any furnaces are available in southern (mixed) climates which exactly meet both cooling and heating loads. Manufacturers typically make one or two furnace sizes for each cooling size. With a furnace that can handle a 3.0 Ton ODU, heating inputs are typically 60k 100k BTU/Hr. Combinations of heating/cooling equipment must be tested by AHRI labs and show a certificate to meet Federal Tax Credit.

Air-to-Air Heat Pump Equipment Selection ACCA Manual S

Air-to-Air Heat Pump Equipment Selection ACCA Manual S

North Carolina Mech. Code Update New general statute enforcement as of Jan. 1, 2010 requires load calculations and floor-to-floor zoning for all new construction and retrofit installations. New construction room by room; retrofit may be by whole house block load calculations. Zoning may be achieved by a separate HVAC system or zoning controls. designed and installed to maintain a maximum temperature differential of 4 degrees Fahrenheit room-to-room and floorto-floor. If a load calculation was not performed or if a load calculation was performed and it is later determined by the Board that the unit installed was undersized or oversized, the installation will be considered as evidence of incompetence. - NCDOI

Duct Design & Sizing Ducts are to be designed based on ACCA Manual D. Equipment size determines required airflow for cooling and heating. Undersized air Return grilles, return building cavities and return trunks typically create the most common bottle necks in duct systems. Problems from undersized duct systems include: Low airflow Reduced energy efficiency, capacity and comfort Noisy air existing registers Increased risk of mold growth inside ductwork

Duct Sizing Other duct system problems include: air leaks, poor air flow balancing, comfort issues, poor indoor air quality, poor mixing of air, un-insulated ductwork. Poorly designed ductwork often can t balance airflow room to room. Properly designed ductwork often is balanced with very little or no adjustment necessary of the volume control dampers to each room. 1 return air filters must not be too restrictive for any given size.

Return Air Filters Common 1 furnace filters often reduce system airflow due to infrequent replacement, undersized return filter grille design, and/or too high MERV rating of filter. 1 furnace filters are NOT designed with the adequate surface area to perform as a whole house air cleaner. May increase duct leakage due to high pressure drop. Recommend the cheapest pleated furnace filter available, and then have an HVAC contractor install a suitable whole-house filtration system, resulting in cleaner evaporator coils, lower risk of mold in ducts, higher energy efficiency, cleaner air, lower filter costs.

Flex Duct Field Guide Typical maximum duct sizes are listed below. See Manual D for details. Caution: Duct connections, fittings, other design and installation aspects will significantly impact the validity of these rules of thumb. See hand-out.

Flex Duct Size Max Airflow [CFM] Cooling [Tons] Typical Grille Supply Branch 6 100 0.2 4x10, 4x12 Supply Branch 7 130 0.3 4x12, 4x14, 6x10 Supply Branch 8 180 0.4 4x14, 6x12, 6x14 Supply Trunk 10 280-360 0.9 Supply Trunk 12 440 520 1.3 Supply Trunk 14 580 720 1.8 Supply Trunk 14 Short/Plenum 700-850 2.1 Supply Trunk 16 800 1,000 2.5 Supply Trunk 16 Short/Plenum 960 1,200 3.0 Return Trunk 14 600 1.5 14x25, 16x20 Return Trunk 16 780 2.0 20x20 Return Trunk 18 1,000 2.5

Duct Air Loss The Sneaky Leaks Leaks Around Line Set Entry Holes Leaks In Cabinetry Air Sucking In P-Traps on Air Handlers

Airflow and Blowers Single speed blowers have a few hard wired speeds to choose from but does not change once field wired. If duct system presents too much resistance to blower, lower air flow will occur. Variable speed blowers automatically try to adjust speed to meet selected airflow requirements via DIP switch settings on the control circuit board. If duct system presents too much resistance, blower will try to accommodate using more energy, increasing duct leakage and noise. Variable speed blowers don t guarantee actual airflow! You must measure airflow directly if you need to know actual airflow. There s no substitute for properly designed ductwork!

Measuring Air Flow Methods: 1. Static Pressure and Manufacturer s performanace table data. Accurate and quick. 2. Heat Pump Heat Rise Method measure temperature differential of Return and Supply air temperatures when only resistance heat is on, avoid radiant energy, measure current and voltage and calculate kilowatts, then convert to BTUH. Accurate, takes time. 3. Duct Pressurization Test on zero cruise. Accurate with a skilled field technician, takes time.

Measuring Air Flow Methods: 4. Airflow Capture Hood typically used for commercial. Can be within +-15% accuracy with training and quick. 5. Furnace Heat Rise Method measure temperature differential of Return and Supply air temperatures and calculate heat input from timing the gas meter and furnace AFUE. Inaccurate and cumbersome at best.

Static Pressure Measurement Overview Measure positive air pressure in supply plenum. Measure negative air pressure in return plenum. Add numbers and reference the manufacturer s performance tables. Example: TESP = +0.45 + 0.35 = 0.8 w.c. (inches water col.)

Tips For Measuring Air Flow Ensure HVAC fan is on at 100% speed. Many variable speed blowers will be set for 50% speed when the thermostat is set to FAN ON. Set for maximum cooling and wait for variable speed blower to reach 100%. If outdoor ambient below 65 F, pull the disconnect on the ODU to prevent damage to ODU compressor! If Zoned, ensure all zones calling for maximum cooling. Many single speed blowers set for two different speeds for heating than cooling. Which are you measuring?

Recognizing Zoned Systems Zoning panel (circuit board), zone motorized dampers, and (hopefully) a by-pass duct/damper. Multiple thermostats for one HVAC system - One thermostat per zone.

Combustion & CO Flue pipes must be intact and installed properly Back-drafting other appliances e.g. natural draft water heater in same space as non-direct vented furnace and space is tight. Certified Combustion Analyses can be performed on all combustion appliances to determine performance and safety factors. Get certified and work with HVAC contractor

Combustion Safety Issue Examples

Combustion Safety Issue Examples

Fungal Growth In HVAC Some common conditions for fungal growth may include: Low airflow with unsealed ductwork during A/C Low airflow, due to a variety of reasons, produces overly chilled air temps and an introduction of humidity may create condensation inside ductwork. Evaporator coils and drain pan Unsealed vent boots at registers allows attic/crawl space humid air into cool air stream at registers.

Fungal Growth In HVAC

Recognizing Great HVAC Systems Right size capacity Matched system components High efficiency Right duct sizes & design Sealed ductwork Meets all Codes Full system test performed postinstallation Condensate water overflow safety switches and sensors

Recognizing Great HVAC Systems Air balanced room to room, accessible volume control dampers Direct vented furnaces Variable speed blowers Accessibility for future service Access to clean evaporator coils Quiet operation Level solid mounting Ducts insuled on outside with wrap

Hard To Recognize The difficult things to identify are technician installation best practices, control strategy and wiring accuracy, and correct refrigeration: Technicians should always pull a triple vacuum in the refrigeration system, nitrogen purge during brazing, oil removal, accurate weight scales, measure correct refrigerant charge. TXV (Thermal Expansion Valve) now comes standard on all high efficiency equipment, usually found on evaporator coils; also on ODU for heat pumps. Need to know this to measure sub-cooling or super heat for refrigerant charge.

Recognize TXV

Filtration Device Types Media Filter media physically captures particulate Electronic electro-statically charged plates capture particulate Hybrid media and electro-static In-line vs. By-pass type: Bypass air cleaners have their own blower motors and require different ducting, connections and controls

Fresh Air Ventilation Methods 1. Duct into Return plenum 2. Duct into Return plenum with fixed dampers, filters, etc. 3. Duct into Return plenum with automated damper and better controls 4. Energy Recovery Ventilator (ERV) or Heat Recovery Ventilator (HRV)

Energy Recovery Ventilators (ERV) ERV is an indoor air quality device that delivers the fresh outdoor air of opening a window but without the loss of energy. Removes stale air from house Introduces same amount of fresh air Has an enthalpic core (special heat exchanger) which transfers the heat and humidity from incoming air stream to outgoing stream.

Energy Recovery Ventilators

Energy Recovery Ventilators The Necessity of Fresh Air Ventilation Nearly every building research, government and industry expert agrees that fresh air ventilation is recommended in homes. It removes and dilutes polluted air and restores proper carbon dioxide levels. It is part of a total indoor air quality strategy. ERV s are the best method of fresh air ventilation.

Energy Recovery Ventilators The Necessity of Fresh Air Ventilation Older homes with leaky envelopes experience significant natural air infiltration. However, the source of the air usually comes from the crawl space or attic. This does not improve IAQ. New high performance homes have ultra-tight envlopes and require fresh air ventilation. Typical new homes with tight envelopes have some of both problems above.

Energy Recovery Ventilators ERV vs. HRV: HRV (Heat Recovery Ventilator) designed for colder climates. ERV designed for warmer climates with longer more humid cooling seasons. Enthalpic core transfers moisture as well as heat. Cost: $1,500 to $3,000 Brands: Honeywell, Venmar, Carrier, Broan, Aprilaire, Ultimate Air, etc.

Energy Recovery Ventilators Common Problems: Airflow is short circuiting due to poor duct design (on either side of a plenum) Exhaust stream intake grille is located in bathroom or kitchen Low Total Recovery Effectiveness performance (leading to higher indoor humidity)

Energy Recovery Ventilators Common Problems: Fresh air from ERV ducted into a small heating/cooling air handler plenum (results in re-evaporation) Installed so that ERV blower is fighting against heating/cooling air handler blower

Energy Recovery Ventilators Proper Design and Installation of ERV s are CRITICAL to their effective operation and resulting improvement in indoor air quality! Topic Q&A

Central Dehumidifiers The Benefits: Maintains proper indoor humidity levels (50-60% RH) whenever, A/C system does not run (spring, fall, equipment failure) A/C system is oversized House envelope or duct system are so leaky that A/C cannot wring out the enormous amounts of infiltrating humidity before its thermostat shuts it off

Central Dehumidifiers Oversized A/C systems won t control humidity. Evaporator coils require 8-10 minutes to produce condensate; if system short-cycles and runs less than 10 minutes, air will become cold and clammy (uncomfortable). Mold growth on walls may result. Oversized systems also cost more, cycle more and fail sooner.

Central Dehumidifiers Cost: $1,500 to $3,000 Brands: Aprilaire, Thermastor, Honeywell, etc Common Problems: Installed before fundamental problems (such as duct leakage, envelope leakage, moisture issues, etc.) are resolved first Installed with blower fans fighting each other

Central Dehumidifiers Common Problems: No auxilliary drain pan or overflow safety switch for attic installation Ducting resulting in too much airflow bypassing around A/C evaporator coils (proper A/C airflow is critical) Poor maintenance or operation by homeowner Topic Q&A

Q & A

House As A System Building Performance is the new broadly-scoped industry that promotes designing, building and retrofitting homes to be healthy, comfortable, energy efficient, durable and sustainable. A key concept of building performance is to see the house as a system with the various parts interacting with one another. Example: sealing air ducts improves indoor air quality, energy efficiency and comfort.