INSTALLATION INSTRUCTIONS

Similar documents
! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

A B A B4

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Technical Data. Installation

installation, operation & Maintenance manual Floor-mounted Induction units

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

INSTRUCTION MANUAL HS-229G

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Installation, Operation & Service Manual

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Model 9001, Alarm

Ecodrain V1000. Selection and Installation Guide for Residential Applications TM MC TM

Control Panel For Water Wash Hoods AM2

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Model 9001, Alarm

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Installation Instructions

Installation Instructions

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

GAS MONITOR Model Model

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

TABLE 1 Electrical Specifications

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Nachi Series TM Z6957-XL

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

TABLE 1 Electrical Specifications. Phase

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Static Pressure Alarm For Hazardous Location Fume Hoods

Model 53 Macerator Pump Installation, Operation, Repair Manual

Protocol Station Remote Alarm

! WARNING. Before using product, read and understand instructions.

XT Series Thermostats

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Installation Instructions

Macurco HD-11 Hydrogen Gas Detector

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

Carbon Dioxide Sample-Draw Detector Operator s Manual

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Installation Instructions

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Installation Instructions Air Pump

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

User s Manual and Operating Instructions

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Combustible Gas Sample-Draw Detector Operator s Manual

INSTALLATION, OPERATION AND MAINTENANCE

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

INSTRUCTIONS FOR OPERATION AND CARE OF

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

INSTALLATION. Glass Panel Doors (select models) CAUTION

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation & Operation Manual

INTRODUCTION / TABLE OF CONTENTS

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

FUME HOOD MONITOR ALNOR AIRGARD 200

Figure 1. Figure 2. See notes 1 and 2 below.

The Series LFII (TY3596) Residential

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

INSTANT-FLOW C-MICRO WATER HEATER

Thermal Stability Systems

TR-SERIES LIFTKLEEN PARTS DRYER

installation, operation & Maintenance manual acb ceiling-mounted cassette models

BUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Installation Instructions Built-In Dishwasher

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

VP17A BUNN OPERATING & SERVICE MANUAL

Model 4001 Series Single Channel Controller

Installation Instructions

MICRO SWITCH NT Series

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

User s Manual and Operating Instructions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

918 Clock Gauge Installation, Operation, and Maintenance Instructions

HW-17 Record Cleaning Machine Setup and Instruction Manual

Transcription:

Harwil Model Q-16 fluid flow switch is intended for use in flow lines with fluids not harmful to brass, stainless steel, and EPDM. The switch is used to signal, start, or stop electrically operated equipment when flow or no-flow conditions occur. This device is designed for use only as an operating control. Where an operating control failure would result in personal injury and/or loss of property, it is the responsibility of the installer to add devices (safety, limit controls), or systems (alarm, supervisory systems) that protect against or that warn of, control failure. COVER INSTALLATION INSTRUCTIONS 15 AMP - SPDT MICROSWITCH NORMALLY CLOSED 1/2" CONDUIT CONNECTION NORMALLY OPEN ADJUSTING SCREW COMMON TENSION SPRING FIGURE 1. PRODUCT DIAGRAM FEED THRU SHAFT ASSY FLOW SWITCH BODY STAINLESS STEEL PADDLES (4) 2D 5D TURBULENT FLOW REDUCTION MOUNT IN THREE POSITIONS WARNING Before using product, read and understand instructions. Please save these instructions for future use. All work must be performed by qualified personnel trained in the proper applications, installation, and maintenance of plumbing and electrical equipment in accordance with all applicable codes and ordinances. To prevent electrocution DO NOT TOUCH the switch terminals when electrical power is connected to the flow switch. Make sure flow switch cover is secured before turning on electric power. P. 1

FIGURE 2. INSTALLATION DIMENSIONS SPECIFICATIONS 3 3 16 3 3 4 1 19 32 1 1 4 1 1 2 3 3 16 2 1 16 3 3 4 PLAN VIEW 1" NPT SIDE VIEW INCLUDED PADDLE SET GIVES LENGTHS OF: 1 1/2, 2 1/2 3 5/8, 7 1/4 FRONT VIEW Liquid Temperature Range Ambient Temperature Range Maximum Service Pressure Electrical Enclosure Rating Process Connection Conduit Usage 32-250 F (0-121 C) 32-150 F (0-66 C) 250 psi NEMA Type 1 (Not for use in hazardous locations.) 1 NPT One opening for ½ conduit 1 Pipe and Larger ELECTRICAL RATING Single-Pole-Double-Throw (SPDT) Contact Rating: 15A, ½ hp; 125, 250, 277VAC ½A, 125VDC; ¼A, 250VDC P. 2

FIGURE 3. FLOW RANGE TABLE Pipe Size NPT Switchpoint Range (GPM) Min. Adjust. Max. Adjust. ON OFF ON OFF Paddle Size (inches) 1 4 2 8 7 1.30 FIGURE 4. PADDLE SIZES 0 1½ 7 5 13 11 1.85 2 12 7 27 26 2.30 2½ 18 12 35 32 2.83 3 27 19 52 49 3.40 4 63 50 123 120 4.50 5 125 100 238 232 5.50 6 190 158 350 338 6.50 Consult the factory for larger pipes and additional switch points. 1¼ PIPE 1½ PIPE 2 PIPE 2½ PIPE 1.30 1.60 1.85 2.30 2.85 3 PIPE 3.40 DIRECTION OF FLOW 4 PIPE 4.50 5 PIPE 5.50 6 PIPE 7 PIPE 6.50 7.00 FIGURE 5. MULTIPLE PADDLE CONFIGURATION P. 3

INSTALLATION INSTRUCTIONS The Model Q-16 should be mounted on the top of a horizontal section of pipe. If it is mounted in a vertical pipe, the switch points will deviate from those published. If the flow is DOWNWARD, switch points will be LOWER than published. If flow is UPWARD, switch points will be HIGHER than published. FIGURE 6. Q-16 IN PIPE 1 PIPE CONNECTION FLUID FLOW D 5 x D MINIMUM 5 x D MINIMUM D = PIPE DIAMETER The flow switch should be located in a straight run of at least 5 pipe diameters. 1. Determine the proper paddle length from the chart next to the Flow Range Table [FIGURE 3]. For intermediate sizes, trim the next largest paddle to the correct length. The paddle must not touch the inside of the pipe. If more than one paddle is being installed, stack one on top of the other with the larger ones first in line with the flow. [FIGURE 5.] 2. Use a reducing tee for pipe sizes larger than 1 to provide adequate paddle length in the liquid flow. A weldolet or half coupling may also be used. If a reducing tee is not available, use a bushing to reduce the tee outlet to 1 pipe thread. 3. Be sure the flow switch is mounted such that the flow direction is perpendicular to the paddle and that it activates the flow switch when there is flow and de-activates at rest when there is no flow. CAUTION: DO NOT TIGHTEN BY GRASPING THE SWITCH ENCLOSURE. USE THE HEX FLATS AND WRENCH. P. 4

ELECTRICAL WIRING WARNING To prevent electrical shock, turn off the electrical power before making electrical connections. To prevent electrocution, do not touch the terminals when electrical power is connected to the flow switch. To prevent an electrical fire or equipment damage, use properly temperature-rated supply wire for the anticipated temperature. Make all electrical connections in accordance with the National Electrical Code and local regulations. 1. Using a Phillips screwdriver, remove the two (2) cover screws and remove the cover. 2. Connect electrical conduit connector to the flow switch enclosure. Follow accepted electrical practices when installing fittings and making connections. Refer to, and follow, local codes and standards when selecting the types of electrical fittings and conduit to connect to flow switch. 3. Determine which switch action is required for the flow switch. 4. Using a scissor-style crimping tool (3M TH-450 or equivalent), crimp 14 gage wire to the female flag disconnect terminals (3M 752-187) included with the switch. *Note: Use copper wire only FIGURE 7. LOOSEN OR REMOVE SCREWS TO REMOVE COVER 5. Attach ground wire to green grounding screw on flow switch base. P. 5

Power applied to load when flow is GREATER than set point, interrupted when flow is LESS than set point (normally open). LOAD FIGURE 8. COM NO HOT NC LINE Power applied to load when flow is LESS than set point, interrupted when flow is GREATER than set point (normally closed). FIGURE 9. LOAD HOT COM NO NC LINE P. 6

SWITCH POINT ADJUSTMENT SPRING POSITION WHEN DELIVERED LEADSCREW FIGURE 10. MICROSWITCH ADJUST LEADSCREW BEST ADJUSTMENT POINT (CENTERED) 1. TURN OFF POWER. 2. Remove cover. 3. Adjust fluid flow in system to desired rate WITHOUT regard to Q-16 switch point setting. 4. The switch point adjusting mechanism consists of an adjusting screw, a U shaped nut, and a helical spring. CLOCKWISE rotation of the adjusting screw changes the microswitch actuation point toward HIGHER flow rates. NOTES: All Q-16 units are factory set at the lower end of the flow range, e.g. the adjusting screw is set at the low flow counter-clockwise position. The lead screw nut locks the adjusting screw in position, maintaining the flow switch set point under all environmental conditions. 5. Starting with the nut in low-flow position (tension spring relaxed), turn the adjusting screw in a clockwise direction until the microswitch is actuated, while maintaining the desired fluid flow rate in the system. Turn the adjusting screw TWO (2) additional turns in the clockwise direction and then slowly back off in a counterclockwise direction, until the microswitch is de-actuated. The Q-16 flow switch is now set at maximum sensitivity for detecting small flow changes. 6. When set at maximum sensitivity (100% point) as described above, flow turbulence may cause rapid on/off switching (dithering) of the microswitch contacts, resulting in reduced switch contact life and noise in the electrical circuit. This is eliminated by turning the adjusting screw in a counter-clockwise direction. 7. Microswitch actuation point may be monitored during the adjustment procedure detail in steps 5 and 6 P. 7

by an audible click, with an ohmmeter, or with other continuity tester before connecting line power to the microswitch. 8. If the system flow rate is changed, the Q-16 can be adjusted to monitor the new flow rate by turning the adjusting screw in a counter-clockwise direction to the minimum flow position and then proceeding as in 5 and 6 above. 9. Place cover on the flow switch and turn on power. 10. Test the operation of the flow switch after each adjustment. TESTING Place cover on flow switch and turn on power. Observe whether the flow switch is being activated by the flow. Turn off fluid flow to determine if the device is operating as required. Repeat initiating and turning off fluid flow several times. If operating as required, put system into service. If not operating as required, flow switch may need to be adjusted. P. 8

CERTIFICATE OF CONFORMANCE All Harwil Corporation ( HARWIL ) products are manufactured using new materials and components. Our products meet the applicable performance and materials specifications indicated in our current Specifications Sheets and Parts List. HARWIL endeavors to obtain its materials and components from American Companies. DOMINANCE OF HARWIL LIMITED EXPRESS WARRANTY Each user MUST make appropriate analysis and tests to determine the suitability of the HARWIL product for the intended use prior to purchase. HARWIL warrants that all HARWIL products will be free from defects in material and workmanship for a period of one year from the date of original shipment. This Warranty shall be LIMITED to the replacement and reconditioning of our products and parts. HARWIL reserves the right and sole discretion to modify or change the composition, design and appearance of its products at anytime. THIS WARRANTY SHALL BE IN LIEU OF ALL WARRANTIES OF MERCHANTABILITY AND OF ALL WAR- RANTIES OF FITNESS FOR A PARTICULAR PURPOSE RELATING TO HARWIL PRODUCTS AND PARTS. BUYER S SOLE REMEDY SHALL BE REPLACEMENT OR RECONDITIONING AS SET FORTH HEREIN. HARWIL SHALL INCUR NO OBLIGATIONS HEREUNDER AND NO LIABILITY IN THE EVENT OF (1) BUYER NOT FULFILLING ITS RESPONSIBILITIES; INCLUDING AS SET FORTH HEREIN; (2) NEGLECT, ALTERATION OR IMPROPER PRODUCT USE, INCLUDING USE WITH NON-COMPATIBLE DEVICES OR CHEMICALS; OR (3) REPAIR BY ANOTHER COMPANY OR PERSON THAN HARWIL. ANY LAWSUIT RELATING TO THIS LIMITED EXPRESS WARRANTY MUST BE COMMENCED WITHIN ONE YEAR OF THE DATE THE LAWSUIT ACCRUES. HARWIL provides NO WARRANTY and ASSUMES NO RESPONSIBILITY for corrosive attack on any material, component or design features associated with any of its products. Corrosion resistance information listed in HARWIL specification sheets, information sheets and product brochures is solely for general background information. This information table has been compiled from literature published by various material suppliers and by equipment manufacturers who use these materials in their products. Inasmuch as these data are based on tests by entities over which HARWIL has no control, HARWIL DOES NOT GUARANTEE AND DOES NOT ACCEPT ANY RESPONSIBILITY FOR THE ACCURACY OF SUCH THIRD PARTY TESTING. When using the table, please remember that in any given case several factors such as concentration, temperature, degrees of agitation and presence of impurities influence the rate of corrosion. The information table is intended, in a general way, to rate materials for resistance to chemicals which contain their usual impurities and for types of equipment in common use. Ratings should be used only as a general tool to first approximation of your material requirements rather than as the final answer. WHEN IN DOUBT, TEST MATERIALS BEFORE INSTALLATION. AFTER INSTALLATION, FOLLOW UP WITH SCHEDULED PREVENTATIVE MAINTENANCE AND PERIODIC INSPECTION. 16306 P. 9