MiNi Server environment MoNitoriNg SySteM

Similar documents
ENtErPriSE SErvEr ENviroNMENt MoNitoriNg SyStEM SNMP and Web monitoring/management of server room environments

ENtErPriSE SErvEr ENviroNMENt MoNitoriNg SyStEM SNMP and Web monitoring/management of server room environments

ENTERPRISE SERVER ENVIRONMENT MONITORING SYSTEM SNMP and Web monitoring/management of server room environments ENVIROMUX

Monitoring Solutions

CAN unit for Analog Sensors

Outdoor Temperature Sensor

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Typical applications include the vibration detector. Detection of vibrations and shocks

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

IndigoVision Alarm Panel. User Guide

AirFlow Sensor for Dry Contact connection

IntesisBox BACnet/IP Server - Notifier ID3000 series

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM RAMOS Ultra

600 Range Dialer Installation Manual. Version 1.0

SC-F3G User Manual 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

REMOTE MONITORING AND ALARM SYSTEM

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

ModBus DE-1 INSTALLATION AND USER MANUAL

ECO PDU PE7214/PE7216/PE7324/PE7328

Galaxy Pulsar Plus Digital Battery Plant Controller

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Optional Parts (sold separately): E-4WNSC-x 4-Wire Non-Sensing cable (available in lengths 10/25/50/100 feet and custom lengths up to 1000 feet)

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

Security designed for your lifestyle

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Data Center. Cold Storage

Added password for IP setup page : Password must be in IP format!

SMS GSM Alarm Messenger

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

idware Idware Remote Site Monitoring Solution

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

The future of security, secured IP by security professionals, for the professional security industry

MODEL NUMBER: SRCOOL60KCW

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

NTI ENVIROMUX-SDS-CELC(P) PHOTOELECTRIC SMOKE DETECTION SENSOR. Installation Instruction. Introduction. Product Features

GLOBAL. InstallatIon & operation manual

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

Innovative Circuit Technology Ltd.

Didactum Monitoring System 50

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

Innovative Circuit Technology Ltd.

Complete packages with Software and Controller

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

GUARD YOUR MISSION-CRITICAL IT EQUIPMENT ALERTWERKS SERVSENSOR MONITORING HUBS AND INTELLIGENT SENSORS BLACKBOX.

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

Advanced Power Monitor (APM)

T4000 Security Communicator

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

EXPANDABLE SMART HOME SECURITY KIT

COMMUNICATOR ET08 / ET081

SENSAPHONE 901 Tryens Road Aston, PA PH:

WebAlert WA500 Series Process Monitor Instruction Manual

Alarm module for leak detection with webserver

UNC100 Integra Manual

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Smart Wireless Sensor

User-Manual MultiSensor-RACK. From Firmware Version 3.xx.xx.

Architectural and Engineering Specification for a. Flash / Flare

TM3 monitoring unit. installation and users manual

your silent and loyal servant

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Smart Wireless Sensor

Installation, Configuration and User Manual

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

ACTIVE INFRARED BARRIER

Elderly Care Alarm System

Environmental Monitoring and Alarming

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

One panel offers everything you want built-in

LORAIN CIP 4890/48120 DC Power System

Instruction Manual Environmental Monitoring Unit with Output Relay

RLP-2048BBSCLVD-MU Internet Ready Heavy Duty AC to DC Power Supply With Built-in Remote Monitoring and Control. Owners Guide

Ontech GSM 9040/50. Reference Manual English -1 -

Model 135 Reference Document

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

LORAIN CSP DC Power System

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Didactum Monitoring System 100 III

Healthy. Atmosphere. for Pigs and Poultry. for a

Installation and User Instructions

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

SEE DISCLAIMER ON REVERSE

D3D Wi-Fi GSM Smart Alarm System -User Manual

Fratech Multipath-IP

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Transcription:

enviromux-mini with enviromux-t-3 temperature Sensor Features & Applications Monitors threats: temperature Humidity Water Leakage intrusion The ENVIROMUX Mini Server Environment Monitoring System monitors critical environmental conditions (such as temperature, humidity, and water leakage) that could destroy network components in your server room. When a sensor goes out of range of a configurable threshold, the system will notify you via email, SNMP traps, web-page alerts, a visual indicator (red LED), and SMS messages (via external GSM or 3G modem). Monitor and manage server room environmental conditions over IP. Integrates with various Open Source monitoring packages Nagios Sensors supported: and MRTG. 2 temperature/humidity sensors Optional industrial mini server environment monitoring system for 1 liquid detection sensor high temperature environments. This industrial system has the ability 4 digital inputs sensitive to contact closure to operate and monitor in harsh environments at high temperatures up Alerts are posted in message log, which is accessible through Web to 167 F (75 C). user interface. Add "-IND" to the end of the part number to specify this option. The log can be downloaded as a tab-delimited plain text file. Use in data centers, co-lo sites, web hosting facilities, telecom Flexible Zero-RU mounting. switching sites, POP sites, server closets, or any unmanned area that Mounting tabs included. needs to be monitored. Optional DIN mounting available. temperature/humidity inputs Two female RJ45 connectors for connecting temperature sensors, humidity sensors and/or combined temperature/humidity sensors. Water Detection Cable input One screw terminal pair for connecting liquid detection sensor. Additional water detection sensors can be connected to the dry contact closures. Output voltage: +5VDC. Current limited to 10mA Maximum resistance to close contact: 300K Ohm. Dry Contact Closures Four screw terminal pairs for connecting dry contact devices. Potential-free. Output voltage: +5VDC Current limited to 10mA Maximum resistance to close contact: 300K Ohm rs232 Port One female RJ45 connector for controlling a GSM modem. Supports 3-wire interface (Tx, Rx and GND) Used for flash upgrades (includes DB9F-RJ45F adapter). GSM modem supported: Teltonika WirelessCom/G10. 3G modem supported: NetComm N3GS003 MtBF 80,327 hrs. Specifications ethernet Port One female RJ45 connector with LEDs. 10 BaseT Ethernet interface. Protocols HTTP, SNMP V1, SMTP, TCP/IP, UDP, DHCP Compatible with any SNMP management software. Operates and configures via HTTP web page. Supports Microsoft Internet Explorer 6.0 and higher. An IP address can be assigned to the ENVIROMUX-MINI automatically by a DHCP server. Generates SNMP traps, email alerts, and syslog messages. Email alerts can be sent to three addresses. Up to four users can access the Web interface simultaneously. Dimensions WxDxH (in.): 5.6x2x2 regulatory Approvals ENVIROMUX-MINI: CE, UL, cul, RoHS ENVIROMUX-MINI-IND: CE, UL, cul, RoHS Power 110 or 220 VAC at 50 or 60 Hz via AC adapter. Power consumption: 5W Use the PWR-48V-5V1A DC-DC power converter to install the ENVIROMUX-MINI in a Telecom environment. 1

enviromux-t-xx Control Methods Configuration can be done over the Internet/LAN via Web page. Front Panel interface LEDs indicate the following: Fault (red) lights up if a sensor goes out of range of a configurable threshold. Power (green) lights up when the device is powered/all clear. Web interface Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC. Configure sensor s thresholds, alarm methods, formats of alerts, and system data log. View/edit sensors current values, thresholds and alert statuses. All sensors connected to the ENVIROMUX-MINI can be viewed on one summary page. User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert. View/edit entries stored in the system data log. The log can be downloaded as a tab-delimited plain text file. Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings. Up to four users can access the web page at one time. WAP Mobile Summary Page View summary page on WAP 2.0 compatible devices (smartphones, PDAs, cell phones, etc.) Supports Blackberry Software 4.2 and higher. Supports iphones using Safari 3.0 and higher. Summary page lists all connected sensors' current values and alert statuses. Temperature Sensor Applications from 32 F to 104 F (0ºC to 40ºC). Accurate to within ±1.35 F (±0.75ºC). Environmental Sensors DIN Rail Mounting Option enviromux-mini-d with optional DiN rail mounting for industrial applications Configuration and Cable illustration Temperature Sensor, Extended Range For use with ENVIROMUX-MINI-IND. Applications from 32 F to 167 F (0ºC and 75ºC). Accurate to within ±2.25 F (±1.25ºC). enviromux-t-ind-xx 330.562.1999 Worldwide fax sales@ntigo.com www.networktechinc.com 2005, 2010 NTI All rights reserved 2

Temperature/Humidity Combination Sensor enviromux-trh-xx enviromux-ldx-y enviromux-2w-xx Liquid Detection Sensor For warning of flooding. 100% waterproof electronics. Detects any conductive liquid. Puddle: 0.6" diameter. Detects liquid depth >0.1". Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/ 800/1000 feet. Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Sensor Cables Environmental Sensors (continued) Applications from 32 F to 104 F (0ºC and 40ºC) and 20% to 80% relative humidity. Accurate to within ±1.35 F (±0.75ºC) and ±5% relative humidity. 2-wire sensor cable. Use to connect dry contact sensors to the ENVIROMUX-MINI. Available lengths (ft): 3/6/10/25/50/100, UL enviromux-rh-xx Humidity Sensor Applications from 20% to 80% relative humidity at temperatures between 0ºC and 40ºC. Accurate to within ±5% relative humidity. Smoke Detection Sensor For warning of smoke. Built-in 135 F (57 C) thermal heat sensor. Photoelectric smoke detector. enviromux-sds-pa Regulatory approvals: UL enviromux-cmd-p Carbon Monoxide Detector Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes 150 ppm after 10 to 50 minutes 400 ppm after 4 to 15 minutes Flush or surface mount. Test functionality of electrochemical CO sensing cell. LED indicators for operation status and system test. Regulatory approvals: UL 3

enviromux-m-dcs enviromux-tds Door Contact Sensor Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. For normally closed circuit connection. 2-wire interface; screw terminal Wide actuating gap, about 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Ceiling Mount Infrared Motion Detector Detects movement across the detection field. 360 detection pattern. 113 conical detection angle from ceiling. 36' diameter protection when mounted 12' high. Provides substantial immunity to false alarms caused by environmental disturbances. Good RFI protection enviromux-imd-cmp enviromux-gbs-p Glass Break Detection Sensor Acoustically detects the cracking of glass. Adjustable sensitivity. Tamper Switch Sends activation signal when tamper switch is released. Normally closed contact when depressed. Dimensions (in): inner diameter: 0.8, outer diameter: 0.9, height: 2.9 2-wire interface. Motion/Intrusion Sensors (Continued) Sensors enviromux-imd-p enviromux-ebs Infrared Motion Detector Registers movement in the area covered. Condition display via LED. Provides immunity from common-mode signals such as the effect of strong hot or cold air currents, variation in ambient temperature, background radiation and acoustic noise. 24 dual-element detection zones for long, mid and short range protections. Good RFI protection. Mini Infrared Motion Detector Detects movement across the detection field. Provides substantial immunity to false alarms caused by environmental disturbances. Good RFI protection. Dimensions WxDxH (in): 2.2x1.2x2.9 enviromux-imd-mwp Emergency / Panic Button Sends activation signal when button is pressed. For normally closed or normally open circuit connections. 2-wire interface. Dimensions WxDxH (in): 0.4x0.9x3 330.562.1999 Worldwide fax sales@ntigo.com www.networktechinc.com 2005, 2010 NTI All rights reserved 4

Sends SMS text messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. GSM modem with antenna built into system. Convenient push-push SIM card holder Mini SIM card supporting SMS enviromux-gsm-p messaging required (not included) Protocols: AT commands Supports one configurable authorized phone number for sending SMS text messages. Auto PIN feature, no need to enter SIM card PIN after restart Quad band: 850/900/1800/1900 MHz SMS: Text mode Power: 110 or 220 VAC at 50 or 60 Hz via AC adapter. Regulatory Approvals: CE PWr-48v-5v1A GSM Modem Power Over Ethernet Adapter Enables ENVIROMUX-MINI to be powered over Ethernet connection. Eliminate the need to place ethernetenabled devices near power outlets, giving more freedom of placement. Supply Power and Data up to 300 feet enviromux-poe using standard Ethernet cabling. Outputs Power on an attached DC power cable, and Data on an attached Ethernet cable. Ethernet Pin Usage: Data: 1,2,3,6 Power: 4,5,7,8 No tools or software necessary for installation. Overload and short circuit protection. Standards: 802.3af Dimensions WxDxH (in): 3x3.25x1.5 Maximum power output: 5VDC @ 2.4A., FCC, CE Power Converter Alert/Communications Sensors Power Sensors & Accessories Use the PWR-48V-5V1A power converter to install the ENVIROMUX- MINI in a Telecom environment. Accepts 36~72VDC (48 VDC nominal). Accepts positive or negative polarity. Outputs +5VDC and can handle 1A load. 3-pole detachable screw terminal for connecting 48V input. 2.1x5.5mm male DC power jack. Dimensions WxDxH (in): 1.8x2.1x1 3G Serial Modem Sends SMS text messages to a cell phone when a sensor goes out of range of a configurable threshold. Removable antenna. Supports third generation (3G) digital cellular standards. Convenient push button SIM card holder. enviromux-3g Mini SIM card supporting 3G SMS messaging required (not included) Protocols: AT commands Supports one configurable authorized phone number for sending SMS text messages. Tri-band UMTS (HSDPA): 850/1900/2100 MHz Quad band EDGE/GPRS/GSM: 850/900/1800/1900 MHz Includes 12V/1A power supply. AC Voltage Detector Measurement range: detects voltage from 50 to 250 VAC. Measurement indication: Alarm or Normal. Sensor type: open/closed contact switch. Attached 3-foot power cord. ENVIROMUX-ACVD-515M: enviromux-acvd-515m Standard US 120V 15A NEMA enviromux-acvd-515 5-15 plug (When using with enviromux-acvd-c14m ENVIROMUX-MINI that was enviromux-acvd-c14 purchased before 11/1/2008, use part number ENVIROMUX-ACVD-515) ENVIROMUX-ACVD-C14M: Universal 250V IEC C14 socket (When using with ENVIROMUX- MINI that was purchased before 11/1/2008, use part number ENVIROMUX-ACVD-C14). DC Voltage Detector Measurement range: detects voltage from 24-36 VDC. Contacts remain closed between 26-36 VDC Contacts open when monitored enviromux-dcvd-24v-m voltage drops below 24 VDC Measurement indication: Alarm or Normal. Sensor type: open/closed contact switch. Includes 6-foot 2-wire cable to connect to the ENVIROMUX-MINI. Attached 3-foot power cord with tinned leads on 3 wires. For use with ENVIROMUX-MINI purchased on or after 11/1/2007. 5