The Principles, The Process, and The Results:

Similar documents
SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Cleaning Verification

ProFormanceTM Cleaning Verification Products

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

When you sterilize an instrument set, you know what the standards are.

Washer Test Kits User Guide

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

THE BASICS OF DECONTAMINATION

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

Instructions for Use Spinal Punches IFU

Lower Your Costs. Expand Your Flexibility.

STERITITE INSTRUCTIONS FOR USE

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

Cleaning & Sterilization

Improving the Performance of Your Medical Automatic Washer

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

In 2011 JCAHO in standard E.C.6.20; states that all medical equipment is maintained, tested and inspected (2).

Lower Your Costs. Expand Your Flexibility.

CLEANING INSTRUCTIONS

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

The Journal of ProFormance TM Monitoring

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

I.F.U Re/Processing Reusable Medical Devices

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

STERIS Instrument Cleaning Chemistries

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

HTM made easy. Testing Explained... in fact everything you need to know about HTM but were too afraid to ask!

FLASH PAK STERILIZATION CONTAINER SYSTEM

Clean Smarter. Systems Catalog

Processing instructions for the Ligamys suture forceps

Precision Ultrasonic Cleaning Equipment Buyers Guide

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Operating / User Manual

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

Ultrasonic From delicate microsurgery instruments to heavy duty sets

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

ENDOSCOPE DECONTAMINATION : Where are we now!

Cleaning and Sterilization for Instruments & Posts

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

2015 Myco Industries, Inc Fax:

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

Disclosure. Today. Why are we here today. The College of Clean The Foundation Part 1. This is why you are here today. Watch this short video 3/26/2015

Surgical Instrument Cleaning Process

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Disclosure. Running a Medical Devise Reprocessing Department(MDRD) requires a lot of Knowledge

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Accurately With HSE COP PT 1 5

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

RECOMMENDATIONS FOR CLEANING DEVICES

Clean Smarter. Systems Catalog

Sterile Processing. Knowledge, Skills, Competencies. Terri Goodman, PhD, RN

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

Sterling P1500 Washer-Disinf ec t or Acce s s or y Guide

Cleaning and Sterilisation for Burs, accessories and filling material

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

ULTRASONIC (SONIC) CLEANING ENHANCES THE INSTRUMENT

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Instrument Cleaning Chemistries Automated Washing Process

Flexible endoscope automated reprocessing system

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

Aesculap Implant Systems

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

Dr. Weigert - New Standards in Cleaning and Disinfection of Medical Devices

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

Recommendations for cleaning, decontamination and sterilisation. devices

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

CLEANING OF INSTRUMENTS

An evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments

ANSI/AAMI ST79: Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Suzanne Latta, CSPDT

AMITY INTERNATIONAL (U.K.)

PICNet CONFERENCE 2013

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

8/18/2014. Welcome! How do I get a CE Certificate?

Harvey Chemiclave 5000 Owner And Operator Guide

Important information

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

Classification of Instruments -

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

Transcription:

The Principles, The Process, and The Results: Presented by: Fred Alston, CSPDT Eastern Region Clinical Sales and Support Manager April 21, 2017

I am an employee of Healthmark Industries Fraser, Michigan USA I am involved with the manufacture and distribution of medical products to healthcare facilities and healthcare professionals No compensation has been received for this presentation or for travel to and from the seminar All opinions are those of the presenter

Healthmark s Policy is to provide our customers and the healthcare community with the highest quality, state of the art medical products and support services in a timely and cost effective manner. This goal is supported by a staff committed to individual accountability, professionalism, mutual respect, collaboration and service excellence. This presentation is part of that commitment, educating our customers.

Making Headlines

Ten surgery patients of Lawrence Hospital Center (LHC) in Bronxville are being notified of the need to get tested for HIV, hepatitis B and hepatitis C due to improperly cleaned equipment. The state Department of Health said the hospital reported that nine surgical trays were found to have been improperly sterilized after they had been used during procedures. They had, however, been cleaned and disinfected. The notice marks the second time in less than one month that an area health care facility has warned of possible exposure to blood-borne diseases. In February, more than 200 patients of the state-run Rockland Psychiatric Center were told they needed to get tested following a case of hepatitis B transmitted through a lancing device to collect blood samples http://www.thebody.com/content/art61004.html?wn From U.S. Centers for Disease Control and Prevention March 14, 2011

A Philadelphia hospital was struck last year by an outbreak of drug-resistant bacteria associated with the use of a special kind of hard-to-clean endoscope, according to city data. Just reported on 2/6/2015 one year later Eight people examined with the scopes became infected with bacteria resistant to a class of last-resort antibiotics called carbapenems, and two patients died. The city Department of Public Health said. These "superbug" bacteria have an estimated mortality rate ranging from 25 percent to 50 percent in those infected. But both of the Philadelphia patients who died had serious underlying conditions, so their deaths were deemed "not clearly related" to the infection, department spokesman Jeff Moran said. Read more at http://www.philly.com/philly/health/20150206 Superbug infects_eight_p atients_at_philly_hospital.html#vhj0c74movgglmtf.99

Any organic matter that remains after manual cleaning lowers the effectiveness of the disinfectant, but the complex nature of endoscopes makes them very difficult to thoroughly decontaminate. With imperfect cleaning, bacteria could survive the disinfection process and infect the next patient. Spach D., Silverstein F. & Stamm W. Annals of Internal Medicine 118, 117-128 (1993).

Water quality Temperature Chemical activity Dilution/Concentration Mechanical action Human factor Time Item to be cleaned Type of soil The various combinations determine how clean your instrument will be.

Water quality is a broad concept covering several key characteristics of the water used. The relevant, measurable characteristics are ph level, Hardness, and Alkalinity.

The ph scale measures the acidity or alkalinity of a liquid. The diagram shows that the scale ranges from 1 which is acid to 14 which is alkaline, the mid-point between the two being 7 which is neutral. As a guide, water would fall around 7.

Water hardness is defined as the concentration of calcium and magnesium ions expressed in terms of calcium carbonate. These and other minerals bind with the cleaning agents in detergents and prevent them from reacting with the soil on instruments.

The amount of hardness minerals and other dissolved solids in water present obstacles to good cleaning. Hardness minerals can cause spotting and filming on instruments. They must be effectively tied up or sequestered if the cleaning results are to be satisfactory. You want a low ppm reading number for hardness (less than 200ppm is good).

Total Alkalinity is a measure of the buffering capability of water to resist changes in the ph level. It is desirable at every given level of ph, to have a high level of Alkalinity (a high number is good).

Dependent upon the cycle & machine design Pre-wash cold water (target 60-90F) Chemistry cycles targeted range Enzyme: 110-140 F See IFU s Detergent: 140-160 F - See IFU s Thermal disinfection 180-205 F Time depends on washer manufacturer: 1 2 min

Enzymes speed up cleaning action. Enzymes are like living cells which attack and breakdown organic soils Each enzyme acts on a particular kind of substance, which is called substrate. In short, an enzyme is thought to fit its substrate much as a key fits a particular lock.

A detergent for medical use must be able to remove all organic and inorganic materials without damaging the device. Temperature of water and the storage environment can affect detergent efficacy

Precise concentration and dilution is dependent on water quality, soil load and temperature Needs to falls into to an range based on expectation of cleaning More is not better residuals

MANUAL PROCESS Sink manifold, lumen flush, and spray gun AUTOMATED PROCESSORS Automated washers, cart washers, and sonic cleaners

An effective management control system which includes all aspects of the cleaning cycle Appropriate facilities are provided Appropriate equipment is available, and utilized appropriately Processing equipment is calibrated, validated and monitored Properly trained and supervised staff Single use items are not reprocessed Records of the decontamination process are maintained

3 Sink Process Rinse - Enzyme - Rinse Brush & Flush Use Cleaning Chemistry Water Temp is Important

Automated Washer / Decontaminators Instrument Washers Ultrasonic Washer Washer Sterilizer Cart Washers

Automated Washers

Observations of machine operations & condition: Occlusion of spray arms Nozzle directions Freedom of movement of spinner arms Instrument rack coupler alignment Staining, scaling of inside of chamber Clean screens, wipe down equipment Make sure the light in the washer is working Is the cleaning solution being delivered properly? Routine monitoring Keep a record of all results (log book) Document the optimal cycle settings (master copy retained)

WHAT S WRONG

Missing Spray Arm Broken

Choose wisely, as they do not all assess the key factors nor meet the criteria for a surrogate testing device Understand the 9 Factors

Test Object Surgical Instrument (TOSI) Nooks and crannies (e.g box lock)

Test Soil - Mimics dried blood; same components of blood Transparent Holder Angled, provides increasing challenge Stainless Steel Plate Scratched, just like a surgical instrument may be

Cart washers are important tools in the overall effort to reduce cross contamination. Often they are used to clean not just surgical case carts, but also basins, instrument trays, wheel chairs and other supply and patient transport equipment.

Ultrasonic cleaners work by producing ultra high frequency sound waves that cause micro explosions. These explosions generate very high pressure of water and also create ultra high temperatures. This combination helps to blast contaminants off of instruments.

Like any mechanical device, from time to time, transducers fail. Given the nature of ultrasonic cleaning, observation of failure is not easy. Also, in a series of transducers, one may be failing, while the remaining units are functioning, creating dead spots within the ultrasonic. Monitoring devices for detecting cavitation are now commercially available.

The cleaning effectiveness of an ultrasonic cleaner can be monitored with a piece of aluminum foil it must be suspended into the cleaning solution extending the full width and depth of the solution. The unit is activated, and after 20-30 seconds, the foil can be removed and examined. The presence of significant pitting and a uniform pattern of dents and holes indicate the cleaning unit is performing properly. This is a very subjective test. SonoCheck

The Sonocheck is put in an empty tank. Record the time the SonoCheck changes color ( it can turn as quickly as 10 seconds). Color change should be from green to yellow. No color change you need to service the equipment. Sonocheck is easy and quick to use.

9 Factors Water Quality Chemistry Mechanical Action Time Temperature

Test object simulating cannulated instruments Use for monitoring the cleaning efficiency for reprocessing cannulated instruments in washerdisinfectors or ultrasonic cleaners Test soil correlating to human blood Video

Manual Ultrasonic Auto Washer Assess work area, environment, facilities X X X Assess water quality X X X Assess use of proper chemicals X X X Monitor temperature for chemical use X X X Monitor chemical dilutions X X X Assess proper functioning of equipment X X Check and clean filters & screens X X Observe machine operations X X Monitor staff performance and competency X X X Visually inspect instruments X X X Test efficacy with a validated test soil device (soil swab device for manual) Document and record results of all measurements and observations X X X X X X

Customer Reference Decontamination Standards, Guidelines & Articles in support of using the TOSI 2014 AAMI New Standard ST-79 Weekly, Preferably Daily After all repairs Must be surrogate device JCAHO: E.C.6.20 All medical equipment must be maintained, tested and inspected. ASTM Standard D7225-06 for Blood Cleaning Efficiency Of Detergents And Washer-disinfectors Based on a standardized test soil correlating to coagulated blood suitable for screening tests and the evaluation of the cleaning efficiency of washerdisinfectors used for reprocessing of surgical instruments.

Recommended Practices for Cleaning and Care of Surgical Instruments and Powered A quality management program should be in place to test mechanical cleaning equipment. Mechanical instrument washers should be tested for proper functioning before initial use, weekly during service, and after major maintenance. Manual cleaning should be evaluated when new types of instruments are reprocessed and periodically, at intervals determined by the health care organization. Testing washer decontaminators on a regular basis verifies that the equipment is functioning properly or identifies an opportunity for corrective action.

Washer testing products are commercially available. XXII.a.2. Periodic testing provides an opportunity to evaluate the performance of personnel. Manual clening is a learned skill and subject to human error. New instruments can pose unique challenges when cleaning. Protein indicators are commercially available to assist with this evaluation. XXII.a.4. Adverse events should be reported in the adverse event reporting system and reviewed for potential opportunities for improvement. When investigating surgical infections, documentation of the cleaning process of instruments should be reviewed. Near misses should be investigated and corrective action taken to prevent serious adverse events.

Simulated testing should be done with a surrogate device that closely approximates the actual types of soil the instrument is exposed to in clinical use. Further the surrogate device should be made of the same type of material as the medical device.

Implement Washer Verification Program Test washer performance Load into empty chamber on each level Test loading configuration Load into full washer in location of concern Mechanical cleaning equipment should be tested upon installation, weekly (preferable daily) during routine use, and after major repairs AAMI ST79 2010 7.5.3.3

Proper Cleaning Patient Use Cycle Selection Biological Read PATIENT PCD / Biologicals Documentation Sterilization Load Release 53

Thank You! Questions? On behalf of Healthmark, I would like to thank you all for the opportunity to be here today. THANK YOU!