For Client Review Only. All Rights Reserved. Advanstar Communications Inc. 2005

Similar documents
An FT-NIR Primer. NR800-A-006

OMA-300 Process Analyzer

Application Note CBRNE Stand-Off Detection of Toxic Industrial Chemicals in Industrial Complexes Using RAPIDplus

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

APPLIED. OMA-406R Rackmount Process Analyzer

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

RAMAN SPECTROSCOPY See more, faster than ever before

Variable Temperature Microprobe Systems

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Variable Temperature Options for Optical Experiments

Chemistry Instrumental Analysis Lecture 14. Chem 4631

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

PUV, PIR and PFO Series BROCHURE

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

Gas Temperature Measurements with High Temporal Resolution

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Document Number March 23, 2016 Yokogawa Electric Corporation. Data Acquisition/Recorder. Data Acquisition and Monitoring. Paperless Recorder

From THz to X-ray - Inventing the Future. Progress in NIR spectroscopy and its industrial applications

SPECTRAL INSTRUMENTATION

Features and Benefits

OPEN PATH DETECTION OF ACROLEIN LEAKS

FIRE IR SENSOR Flame Detection

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

detectors UltiMate 3000 Variable Wavelength Detectors

Technical specifications of FT-IR Spectrometer

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

ACTIVITIES OF THE MEASURING GROUP

Spectrometer Systems Overview

Features and Benefits

Compact Raman spectrometer system for low frequency spectroscopy

Microwave Assisted Vacuum Drying and End Point Determination Using Mass Spectrometry, Part I

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

EXTENDING RAMAN INTO THE THz REGIME

Spectrum IR Series Mid-, Near- and Far-Infrared Spectroscopy THE WINNING PLATFORM

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Milano, 25 novembre 2015

Model S FT-IR SPECTROMETER

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

ROTO MIX HIGH SHEAR MIXER GRANULATOR

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

FACT SHEET Program: Lab Fire Safety

Monitoring for CWAs and TICs in Homeland Security Applications. Charles M. Phillips MKS Instruments Inc., Andover, MA 01810

Early Warning Solutions

Spectrum Detector, Inc.

Broadening IR applications through using spectral filters

QAQC LABS ANALYTICAL DRYING

Low-power laser-based carbon monoxide sensor for fire and post-fire detection using a compact Herriott multipass cell

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

For inspection purposes only.

Gas Detection in Process Industry The Practical Approach

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

New Technologies for Germination Testing

Developing UV LED Curing Processes for Converting Applications

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

REVIEW ON CONDENSER AIR LEAK TEST

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

Measuring Stokes shift. Easy, fast and reliable

High Sensitivity Explosives Detection using Dual-Excitation- Wavelength Resonance-Raman Detector

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Introduction to the Fusion TOC Analyzer

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

SIMRAD GD10PE IR GAS DETECTOR

Optical methods for monitoring gas turbine emissions

Dated 15-Dec-2000; J. Schilz, subject to change

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

CALIDUS tm the Modular micro Gas Chromatograph

Current Research Topics in Optical Sensors and Laser Diagnostics

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

Mercury Vapor Monitor VM-3000

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

SIMRAD GD10 IR GAS DETECTOR

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Specifications for Fluorocarbon Refrigerants

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Specifications for Fluorocarbon Refrigerants

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Transcription:

Monitoring API Drying Operations with NIR The authors describe implementation and performance of a miniaturized NIR analyzer and associated chemometric techniques applied to the monitoring of a drying process for active pharmaceutical ingredients (APIs). They also include a broader discussion of how process analytical technology (PAT) is designed to encompass total quality design concepts using on-line monitoring technology to gain a more complete understanding of pharmaceutical processes. Jill Parris, Christian Airiau, Richard Escott, James Rydzak, and Richard Crocombe There has been a significant increase in process analytical technology (PAT) activity within the pharmaceutical industry during the last 12 18 months largely due to the Guidance for Industry on PAT (1) issued in October of 2004 by FDA. The definition of PAT within the document is more encompassing than one might expect from the common understanding of PAT that has evolved in the chemical and petrochemical industries during the past 20 years. FDA defines PAT as: a system for designing, analyzing, and controlling manufacturing through timely measurements (i.e., during processing) of critical quality and performance attributes of raw and in-process materials and processes, with the goal of ensuring final product quality (1). The guidance goes further to explain the goal of PAT and link it to total quality systems that have been pervasive in many industries. The goal of PAT is to enhance understanding and control the manufacturing process, quality cannot be tested into products; it should be built-in or should be by design (1). The pharmaceutical industry is incorporating PAT into pharmaceutical development through the use of near-line and on-line monitoring tools in order to obtain greater understanding and control of their processes. Though these tools can include many instrumental techniques, mid- and near-infrared, Raman, UV and visible spectroscopy instruments are playing a prominent role (2 5). In this article, the use of a miniature, chip-based NIR spectrometer will be discussed in conjunction with the development of a dryer-monitoring process, one of a number of processes comprising unit operations in the production of APIs (active pharmaceutical ingredients). API Production In the production of APIs, once the material has been isolated from solution and washed, a critical unit operation is the drying of the material. The API material is placed into one of several types of dryers including both agitator and tray dryers. The dryer then is sealed and a vacuum is applied, the temperature is elevated and dry nitrogen make-up gas flows through the dryer. The end point for the drying of GlaxoSmithKline (GSK) production material usually is determined by a technician who samples the API manually a number of times during the process and determines the residual solvent contents by off-line analysis, such as high performance liquid chromatography (HPLC), nuclear magnetic resonance (NMR), or gravimetric analysis. On-line dryer monitoring has the potential to eliminate the need for multiple, in-process sampling during drying, thus speeding up the drying process. The time savings come through eliminating the need to bring the dryer back to atmospheric pressure and ambient temperature, open the dryer oven and sample the material, then close the dryer and resume the low-pressure and high-temperature drying condi- IMAGE COURTESY PHOTODISC 34 Spectroscopy 20(2) February 2005

Intensity (Abs) 0-5 -1 1620 1640 1660 1680 1700 1720 1740 1760 Frequency (nm) tions after the sample is taken. Often, drying is allowed to proceed overnight, which can result in dryer processing problems. Over-drying can cause loss of desired hydrate forms such as a monohydrate, a change in polymorphic form, as well as processing complications such as fracturing of crystals leading to smaller-than-desired particle sizes. This can arise from agitating too long after the solvent has evaporated. Establishing the actual drying For Client Review Only. All Rights having the Reserved. API spectrum Advanstar present as Communications well Inc. 2005 end point can eliminate these problems, reduce drying and cycle times, eliminate over drying of product, lower energy costs, and minimize product sampling with its associated hazards, time, and costs all of which ultimately improve API quality. These are all benefits derived from PAT that also are consistent with the FDA Guideline, and that help to produce data-driven process understanding. Isopropyl acetate Acetonitrile Methylene chloride Ethanol Ethyl acetate Hexane Isopropanol Methyl-tert-butyl ether Isopropyl acetate Methanol Methyl isobutyl ketone Petroleum ether Figure 1. Vapor phase spectra of most of the typical solvents seen in drying applications. probe contact with the API can coat or foul the probe with a small amount of material that is not representative, causing misleading results or blocking the probe from seeing any new material. Another advantage of vapor phase monitoring is that the solvent is present in a nitrogen matrix that is inert in the NIR. This makes developing a monitoring method much less complex than it would be if there was contact with the solid, which would be complicated by as the solvent. Most, if not all, of the Vacuum pump To NIR spectrometer Bypass valve Gas optical interface major solvents used to produce APIs have spectra that can be detected in the near-infrared spectrum and analyzed using chemometric modeling or spectral pre-processing such as first or second derivative. In Figure 1, we see a number of vapor phase solvents measured in a one-meter gas cell with an NIR spectrometer (6). The dryer monitoring application discussed here is one that can be applied to a tray dryer or agitated filter dryer. Figure 2 shows the arrangement for a tray dryer. The API powder, wetted with solvents, is placed in a pan or several pans in the dryer. The system then is heated, a vacuum is applied, and dry nitrogen is drawn through the dryer. The vacuum can pull the gases (nitrogen plus the solvent vapor) directly to the vacuum exhaust or through the gas phase optical interface. This allows the dryer system to be operated when the interface is being serviced, allowing it to be calibrated or cleaned without interfering with drying operations. In addition to the normal particulate filters on the dryer, additional filtration is incorporated before the gas interface to prevent contamination with particulates from the API powder being dried. Experimental The spectrometer used was the Axsun NIR (Axsun Technologies, Billerica, MA). This system is based upon a su- From NIR spectrometer Dryer-Monitoring Application One approach that GSK has taken to dryer monitoring is to analyze the composition of the vapor-phase gases that are drawn from the dryer. This has several advantages to monitoring the solid phase. The primary advantages of the vapor phase approach are its universal applicability to different types of dryers used and that it does not require direct contact of a probe with the API. Direct N 2 + solvent Tray dryer Figure 2. Block diagram of the vacuum tray dryer equipped with the optical gas cell interface. 36 Spectroscopy 20(2) February 2005

perluminescent diode source, MEMS Fabry-Perot tunable filter, and an In- GaAs detector. The system is suitable for the process environment. The optical bench is mounted on a thermoelectric cooler, and is sealed to eliminate exposure to plant gasses that may interfere with the measurement or cause a safety problem. Each scan of the spectrometer is wavelength and absorbance referenced to provide accurate and reproducible spectral measurements. Sixty-four scans were averaged routinely and the measurement time was under 3 seconds. Spectra were measured at 0.25 nm resolution. Communications were tested using s 4-20 ma, USB connection and wireless. The wireless was found to have a range of over 200 feet in all directions. Gas-phase analyses have long been performed using an FT-IR spectrometer in conjunction with a long path length gas cell, of the White design (7). A custom multi-pass gas cell (Axiom Analytical, Irvine, CA) was designed, fabricated and used for the interface to the dryer. Light was delivered to the cell via a single-mode optical fiber and a collimator, resulting in an approximate 2 mm diameter beam. This was coupled via a periscope into the cell. The optics inside the stainless-steel cell consisted of two plane, gold-coated, mirrors and enclosure. provided a pathlength of 1.4 m. The Sampling points 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 12:00 13:12 Drying start 14:12 1.0 Purest spectra for individual solvent 0.9 0.8 0.7 0.6 n-heptane? (end of drying time: scan 143) 0.5 0.4 Methylene chloride (beginning of drying time: scan 50) 0.3 0.2 0.1 0 1550 1600 1650 1700 1750 1800 Wavelength (nm) light was collected by a second periscope and focused into a 600 µm multimode optical fiber, connected back to the spectrometer. Light exiting the fiber was focused onto a 300 µm diameter single-element extended InGaAs detector (1.9 µm cutoff). The overall size of the gas cell was determined by the requirement to couple with a 2-inch diameter vacuum fitting from the exit line of the dryer. The gas cell was a purely passive device, and did not require any additional safety The spectra taken during the gas 15:36 40 min 16:48 18:00 19:12 Figure 4. Profile of PC1 used to trend the decrease in solvent coming from the dryer. 1.5 1.0 0.5 0.0 1620 1640 1660 1680 1700 1720 1740 1760 Wavelength (nm) Figure 3. Vapor phase spectra of n-heptane (blue) and dichloromethane from dryer (spectrum on left) agree well with spectra of pure n-heptane and dichloromethane seen on right analysis were measured from 1390 1780 nm, a region of the nearinfrared associated with the first overtone of carbon hydrogen stretching modes, at 0.25 nm resolution; and 64 scans were averaged. We measured the reference gas-phase spectra at 2 nm resolution and 50 scans, accumulated in less than three seconds. Measurements, Results, and Process Learning The application described here involved drying an API material that was wetted with two solvents, dichloromethane (DCM) and n-heptane. Figure 3 shows spectra of DCM and n-heptane taken on-line and off-line spectra of pure solvents in separate gas cells. Because the boiling point of DCM (39.8 C) and heptane (98 C) differ significantly, taking spectra early (mostly DCM) and late (mostly heptane) in the dryer run produced spectra that agree very well with the pure vapor-phase solvent spectra. This shows that solvents could be monitored individually with this NIR method. Because the object of the analysis was to determine when the wetted API was dry, the spectra were not monitored individually. Initial efforts to monitor the decrease of solvents in the gas stream from the dryer using spectral features were complicated due to baseline shifts. A number of approaches were considered to compensate for the 38 Spectroscopy 20(2) February 2005

Response 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00-0.01-0.02 Vessel agitation Drying complete <0.1% solvent by NMR Start drying 10 30 50 70 90 110 130 150 170 190 210 230 Scan number Figure 5. Fifth drying process to be monitored. Note the sensitivity of the technique allows detection of solvent increases due to agitation. lost at each sampling point. Finally, just before 18:00, the profile levels out, showing that the drying is complete in less than six hours. Success at monitoring the first batches led to the elimination of sampling for off-line testing. Without the large disruptions to the profiles caused by the sampling, coupled with better understanding of the data, we saw an increase in sensitivity (Figure 5). In addition to seeing the profile decline with the solvent concentrations in the dryer gasses, we were able to see the actual liberation of solvent from the multiple agitations that were initiated during the drying process. This allows the operators to see the effects of agitation on the drying process, enabling them to optimize drying. baseline shifting. To overcome this issue and obtain the reaction drying profile, contain the overall trend of the drying profile for the reaction studied. PC1 Conclusions By implementing an on-line NIR tool that enables the monitoring of a critical process attribute, such as the completion of drying, we can accomplish the MOST, IF NOT ALL, OF THE MAJOR SOLVENTS USED TO PRODUCE APIS HAVE SPECTRA THAT CAN BE DETECTED IN THE NEAR-INFRARED SPECTRUM AND ANALYZED USING CHEMOMETRIC MODELING OR SPECTRAL PRE-PROCESSING SUCH AS FIRST OR SECOND DERIVATIVE. the following data analysis was performed using SIMCA-P+ software (8). The dataset consisted of a 2-D matrix X composed of I spectra represented by J variables. The spectra were corrected for baseline shift using 1st order derivatives (5 points Savitsky & Golay coefficients). Principal component analysis (PCA) (9) then was applied to the dataset. The aim of PCA is to reduce the dimensionality of the dataset, while keeping as much information as possible. The data matrix obtained after PCA contains a reduced number of uncorrelated sets of variables, called the principal components (PCs), each of them characterized by two sets of vectors, called the scores and the loadings. The scores relate to the evolution along time, and the loadings to the spectral dimension. The scores of the first principal component (PC1) summarizes the evolution along time of the highly correlated spectral information contained in the NIR spectra. The PC1 scores then were plotted against time to provide the overall drying profile of the reactions. Initially, it was estimated that the drying would take about 12 hours. Figure 4 is a plot of the PC1 scores For Client Review Only. All from Rights the reaction Reserved. measured Advanstar during dry-communications Inc. 2005 ing. The contribution from both solvents represented by PC1 begins at about 12:30 with the solvents at their highest concentration. Sampling points can be seen for the off-line testing, which took place at about 13:00, 14:00, and 16:00. At each of these points, the temperature was lowered and the pressure released to atmospheric to allow the sample to be taken. On average, about 40 minutes of drying time are monitoring goal for the drying unit operation stated in the PAT Guidelines. It provides us with the data we need. However, this is only one part in developing a good PAT application. Good design of experiments needs to be coupled with monitoring to enable us to develop knowledge and understanding from the data provided from monitoring. Without the design step, all we have is data; we do not possess the understanding that is needed to implement a sound control strategy. Without further analysis of the data, we would not know that end point detection, as we have discussed, helps to prevent adverse processing issues, and ultimately can impact the quality and performance of the drug product. By implementing PAT in this way, we can learn more about, and thus control, this key process. Further 40 Spectroscopy 20(2) February 2005

development can enable predictive modeling by correlating the on-line data with the off-line results to give even better control of drying. In the field of process analytical technology, success begets additional success. With the experience gained from this successful implementation, we will be able to apply the advantages of this NIR technology and the PAT process to other, more challenging projects. Acknowledgment We would like to acknowledge Edita Botonjic of Axsun Technologies for running the vapor-phase reference spectra. References 1. Guidance for Industry PAT: A Framework for Innovative Pharmaceutical Development, Manufacturing and Quality Assurance http://www.fda.gov/cder/ guidance/6419fnl.htm 2. Katherine A. Bakeev, Near-infrared spectroscopy as a process analytical tool Part II: At-line and on-line applications and implementation strategies, Spectroscopy 19(1), 39 42 (2004). 3. J. Workman, M. Koch, D. J. Veltcamp, Process Analytical Chemistry, Analytical Chemistry, 75(12), 2859 2876 (2003). 4. E. van Sprang, H. Ramaker, J. Westerhuis, A. Smilde, Near-infrared spectroscopic monitoring of a series of industrial batch processes using a bilinear grey model, Appl. Spectrosc. 57(8), 1007 1019 (2003). 5. I. R. Lewis, Process Raman Spectroscopy, Practical Spectroscopy 28 (Handbook of Raman Spectroscopy), 919 973 (2001). 6. R. A. Crocombe, D. C. Flanders and W. Atia, Micro-optical instrumentation for process spectroscopy, in Lab-on-a Chip: Platforms Devices and Applications, edited by Linda A. Smith and James.W.Rydzak@gsk.com. Daniel Sobek, Proceedings of SPIE, 5591, 11 25 (2004). 7. P. L. Hanst, Pollution: Trace Gas Analysis in Fourier Transform Infrared Spectroscopy, Volume 2, John R. Ferraro and Louis J. Basile, eds., Academic Press, 1979. 8. SIMCA-P+, version 10.5, Multivariate process modeling software (MS Windows), Umetrics AB, PO Box 7960, SE90719 Umea, Sweden. 9. I.T Jolliffe, Principal Component Analysis, Springer, New York, 1986. Jill Parris is an analytical chemist, Christian Airiau is principal chemometrician, and Richard Escott is team manager, all with Process Analytics and Chemometrics, Strategic Technologies, for GlaxoSmithKline (GSK), and based in the U.K. James Rydzak is team leader, Process Analytics and Chemometrics, Strategic Technologies, for GSK, and based in King of Prussia, PA. E-mail: Richard Crocombe is with Axsun Technologies (Billerica, MA). Circle 6 Circle 33