Conducting Residential Cross Connection Inspections

Similar documents
Frequently Asked Questions

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

PLUMBING REQUIREMENTS

EAST FORK S.U.D. NEWSLETTER December 2008

NEW WATER CONNECTION PROCEDURES FOR HOPE AND EDENVILLE TOWNSHIP RESIDENTS

NEW WATER CONNECTION PROCEDURES

Backflow Prevention Cross Connection Control Department can be contact at (956) or (956)

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

System Name. Customer Awareness- Cross Connections and Backflow Prevention

Helping you to understand your water use

PLUMBING INSTALLATIONS

How much do you know about conserving H2O? Read interesting facts about water conservation focused on the toilet from Fluidmaster

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

EMERGENCY INFORMATION

Well Disinfection. Safety Concerns. Electrical. Chemical

Michigan Department of Agriculture and Rural Development

3/12/2018. Cross-Connection Control UF TREEO Conference Cross Connection Survey of High-Hazard Manufacturing Plant.

Table B.1 Guide to degree of hazard - Point of use cross-connections (See Clauses and B.2.)

WATER SAVING TIPS SAMPLE. for Your Home

Water Wise. Skill: Science. Vocabulary. Objectives: Materials. Time Frame: minutes. Lesson Activity. Items to display:

Water is a resource shared by all, and as Florida s population increases, so does the need for all of Florida s residents to conserve.

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

Engelska English. Help us economise on. our precious water! Tips and information on saving water in the Municipality of Eksjö

4. Plumbing fixtures. a) The plumbing fixtures are from the original building. They are appear old and not to comply with ADA requirements.

Food Establishment Plan Review Worksheet

2016 BACKFLOW PREVENTION EDUCATION COUNCIL OF COLORADO REGULATION SEMINAR FIRE SUPPRESSION SYSTEMS PANEL QUESTIONS

Water Conservation Information. Regarding water well pump selection

HOW TO SAVE MONEY ON YOUR WATER BILL

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

City of Attleboro, Massachusetts WATER DEPARTMENT Government Center, 77 Park Street Attleboro, Massachusetts Phone Fax

DISTRICT OF COLDSTREAM and GREATER VERNON WATER NOTICE TO RESIDENTS

Gardening: Growing Vegetables

Dean Piller, President BC Golf Superintendents Association. Dear Mr. Piller: Re: GVWD Water Shortage Response Plan

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

K4600 Assembly Directions

Ways to Save Water & Money

TYPICAL WATER SERVICE INSTALLATION SPECIFICATIONS AND REGULATIONS

Land Map Number BUILDING PERMIT # PROJECT Street Address: Owner: Street Address: City State Zip Phone. Building Contractor: Street Address:

NYC Department of Education

Helping you understand your water usage

EXISTING FIRE SPRINKLER SYSTEMS ARE THEY HAZARDS? HOW CAN WE APPROACH THEM?

NYC Department of Education

Water Conservation. Fact Sheet

HOME PROTECTION PLAN GUIDE

Field Adjuster s Evidence Submission Checklist General Info All Claims

Natural Concept Landscape Co., Inc C SR9 SE Snohomish, WA Office-(360)

Participant has requested a mailed report: YES NO. I would like to begin by asking you a few questions about the building in which you live.

NYC Department of Education

Water Conservation Tips

User s Information Manual

NYC Department of Education

Villas I at Snowden Overlook Condominium Suggested Home Maintenance Checklist July 27, 2018

Stage 1 Drought Restrictions Lifted

Discover Why The Air Inside Your Home Is Killing You Even If You Use Filters Or Purifiers

How your family can help to protect drains and sewers from FATBERGS

Mechanical Inspection Plumbing

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Schedule of Fees Schedule B

CITY OF HUNTINGTON BEACH DROUGHT RESPONSE IMPLEMENTATION

BUILDING DEPARTMENT FEE SCHEDULE

Conduct your own water audit!

NYC Department of Education

Garden Watering Restrictions

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012

The Great Pond Clean-Up

Gulfport, Mississippi 21 May 2007

D EPARTMENT OF W ATER M ANAGEMENT

Special Transitory Food Unit (STFU) & Mobile Food Establishment (MFE) Plan Review Worksheet

NYC Department of Education

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

NYC Department of Education

Chesterfield County Rain Barrel Workshops

Drip Irrigation for the Yard and Garden

NYC Department of Education

SAVE WATER, SAVE LIFE & SAVE THE WORLD

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

Choosing the Right Pump

WHERE THE WATER IS FLOWING

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

NYC Department of Education

2016 Plumbing Supplemental Plan Review List

Rainwater Harvesting Basics

Boil Water Advisories: Questions and Answers

LEAK GUIDE HOW TO IDENTIFY COMMON PLUMBING LEAKS

RAINWATER HARVESTING. An Overview of Rainharvesting Systems

NYC Department of Education

NYC Department of Education

This is Gardening with Chuck on 1420 KJCK, I m Chuck Otte, Geary County, K-State Research

Hotel & motel checklist

Energy Safety and Efficiency

D EPARTMENT OF W ATER M ANAGEMENT

NYC Department of Education

WATER SAMPLE IN DROUGHT CONDITIONS

English as a Second Language Podcast ESL Podcast 376 Asking About Business Hours

111 Ways of Conserving Water in Your Home

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

DESIGN GUIDELINES AND TECHNICAL STANDARDS

NYC Department of Education

WATER DAMAGE - FREQUENCY. July 6, 2017

Plan reviews are required for child care facilities that engage in diaper changing, meal preparation, and/or obtain drinking water from a well.

Transcription:

Michigan Backflow Prevention Association Annual Conference Conducting Residential Cross Connection Inspections Presented by: Dave Cardinal

We ve never had a problem, why do we need to do something now?

Backflow Incident at a Swimming Pool Due to a cross contamination incident with a customer s swimming pool, the Liddieville Water System issued a boil water advisory for all 441 connections in Franklin Parish. The problem has been corrected and system personnel are flushing the system. Samples are planned to be collected on Monday the 6th with results anticipated from the Shreveport lab on Wednesday the 8th. A resident called the Louisiana Department of Health and Human Services to report her family being ill with bacteriological infections. Her suspicions stemmed from the Liddieville Water System as being the source of their problems. The resident stated that their water began smelling and that it had been occurring for quite a while. The resident also stated that she contacted the water system months back and that they sent one of their operators out to flush the line. The complainant stated that the operator was unable to turn on the flush valve at the end of their line due to a tree root that was blocking access to the valve, but that the operator asked the resident to turn on all of their faucets in the home and allow them to flush the line out. The complainant stated that she did and it made the problem better, but the odors had returned and now her son was ill with the same infection that her daughter had earlier during the first episode (at the time she did not know what the children had been treated for). The complainant stated she wanted someone to test their water and findout what it was that was making them sick and if it was coming from the water. The LA Department of Health and Human Services informed the complainant that they were unaware of a recent positive coliform sample for their system. They also informed the complainant that their system did have issues with nitrates and that it should not be an issue as their system chlorinates their water. They asked the complainant what odor she smelled, with her response being algae. They asked the complainant how far off of the main line was their home, with her response being 0.25 miles and that their drive was once a parish maintained road but was now a private drive and they owned 50 acres. The asked the complainant if they had livestock troughs on their farm, to which she said no. When asked about swimming pools, she said yes. They inquired further how was their pool filled and was it an above or below ground pool, with her response being; a big above ground pool and that she filled it with a garden hose. They LA DHHS asked if they left the garden hose in the pool and she replied yes. They asked if she ever noticed it siphoning water at which time she replied yes. They asked what kind of chlorination system do you have with the pool and she said they would turn it on when they were using it, but it was not operated all of the time. The LA DHHS informed the complainant that this was most likely was caused the problem and that she should remove the hose immediately and never to do this again. They informed the complainant that this is a problem for water systems and this type of action can contaminate a distribution system and affect not only her family but her neighbors and other member of the water system. They told her that she should always use an air gap when filling her pool. When the LA DHHS contacted the Liddieville Water System about their findings they stated that they would begin another flush. They said their system has a lot of customers with swimming pools and stock tanks as well as farm chemical tanks. After the discovery boil water advisory was issued for the Liddieville Water System and they also started a program to alert customers about the problems with cross connection.

NUMBERS DATA 33% 26,065 CCC initial surveys of residential homes 8,601 compliant upon initial CCC Survey

TOP UNPROTECTED CROSS- CONNECTIONS DISCOVERED Outside Hose Bibbs 20,387 Interior Hose Connections 11,169 Water Softener Drains 3,096 Boilers 841 Lawn Irrigation 1,636

COMPLIANCE HC has provided over 15,700 AFHBVB to homeowners in 2017 for installation on unprotected cross connections.

UPDATE: WATER QUALITY ALERT COMMUNITY ALERT September 14, 2017 FOR IMMEDIATE RELEASE UPDATE: WATER QUALITY ALERT The do-not-drink advisory remains in place. Residents and businesses should not drink, cook, or consume the water at Alameda Point until additional tests confirm it s safe for consumption. However, as confirmed by various tests and the State Water Resources Control Board Division of Drinking Water, the water is safe for bathing and showering. Next Update: Expect an update tomorrow, Friday, by 3 pm on the status of the water quality alert and the most recent results from laboratory tests.

Non-Residential Fire Sprinklers Cooling Towers Complex Piping Hose Bibbs Approved Vacuum Breaker? C.I.P. Systems Lawn Irrigation Backflow Prevention? Process Use Water Softener Drains Proper Air Gap at Drain? Chemical mixers Boilers Treated with Chemicals?

Residential Survey Letters

Do What? Says Who! @#$*%!!!

Residential Survey Fire Sprinklers Letters

Residential Fire Sprinkler Systems Requirements NFPA 13D NFPA 13R Michigan Residential Code International Fire Code (if applicable) Local requiremens

Multipurpose Piping System Example 1

Multipurpose Piping System Example 2

Multipurpose Piping System Example 3 Network System

Fire Sprinklers Residential Survey Letters Water Softener Drains Proper Air Gap at Drain?

Fire Sprinklers Residential Survey Letters Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain?

Fire Sprinklers Residential Survey Hose Bibbs Approved Vacuum Breaker? Letters Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain?

Source of Pollutant or Contaminant Cross Connection Control Potable Water Supply Cross Connection Control Device

What Risk do some Frost Free Hydrants pose? - Bacterial Contamination Ground level Potential source of contamination Manure, septic, pesticide or fertilizer Water level Potential backflow of contaminated water into riser pipe through weep holes

Fire Sprinklers Residential Survey Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Letters Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain?

Anti-Siphon Ballcock Installation Requirements

Fire Sprinklers Residential Survey Alternative Heating Solar, In-floor heating, Geo Thermal? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Letters Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain?

Fire Sprinklers Residential Survey Alternative Heating Solar, In-floor heating, Geo Thermal? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Letters Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain? Boilers Treated with Chemicals?

Fire Sprinklers Residential Survey Alternative Heating Solar, In-floor heating, Geo Thermal? Letters Bath Tubs Proper Air Gap? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain? Boilers Treated with Chemicals?

Fire Sprinklers Residential Survey Alternative Heating Solar, In-floor heating, Geo Thermal? Letters Bath Tubs Proper Air Gap? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Lawn Irrigation Backflow Prevention? Wash Tubs Vacuum Breaker? Water Softener Drains Proper Air Gap at Drain? Boilers Treated with Chemicals?

Lawn Irrigation System Approved PVB Installation

I can fix it I watch the DIY Network. WON T HAPPEN HERE LACK OF TRAINING KNOWLEDGE WE LL TAKE OUR CHANCES COSTS TOO MUCH MONEY WE DON T HAVE THE STAFF WE LL GET TO IT DURING SLOW TIMES ELECTED OFFICIALS DON T UNDERSTAND Presented by Paul Patterson- Hydro Designs, Inc.

Fire Sprinklers Residential Survey Water Softener Drains Proper Air Gap at Drain? Letters Bath Tubs Proper Air Gap? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Lawn Irrigation Backflow Prevention? Wash Tubs Vacuum Breaker? Back-Up Sump Pumps Powered by Water Pressure! Boilers Treated with Chemicals?

Sump Pumps? -Emergency back up system -Powered by Municipal Water!

-Must have RPZ separation -Must have DNR Written Approval

Professionally installed code violation

Fire Sprinklers Residential Survey Well Supply Interconnection? Water Softener Drains Proper Air Gap at Drain? Letters Bath Tubs Proper Air Gap? Hose Bibbs Approved Vacuum Breaker? Toilet Tanks Approved Device? Lawn Irrigation Backflow Prevention? Wash Tubs Vacuum Breaker? Back-Up Sump Pumps Powered by Water Pressure! Boilers Treated with Chemicals?

Before After

Review Residential Cross Connections do present a hazard to public health Many of the same hazards exist in a home that you would find at a commercial building If you do not have a Residential CCC Program your system may be at risk

Questions??

Dave Cardinal Vice President Operations Municipal Division Hydro Designs, Inc. 5700 Crooks Road, Ste. 100 Troy, MI 48098 800.690.6651 toll free Office: 248.250.5009 dcardinal@hydrocorpinc.com