SolaStat -1-3 An Intelligent Technology Solution for Water Heating USER GUIDE

Similar documents
SolaStat An Intelligent Technology Solution for Water Heating USER GUIDE

SolaStat-Plus. Installation Guide. Z ISO9001 TECHNOLOGY & QUALITY S U P P

SolaStat TM -Plus-ET. Installation Guide FOR QUALIFIED PERSONNEL ONLY

AlphaStat-Plus. Installation Guide. Z ISO9001 TECHNOLOGY & QUALITY S U P P

1.1 Controller General Information

GeyserWise MAX. Instruction manual. All in one hot water management

QD-ENG-68 Controller for Thermoelectric Thermal Management

Smart Temp. Model

SAT-3 Room Temperature Controller

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

OWNER'S MANUAL T0140. Contents Page #

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Heat Pump Defrost Board Replacement Kit

Owner s Manual. Digital Thermostat

USER GUIDE LOGIC HEAT H

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Model: Touch-RS. 1 Touch-RS

2 Minimiser SE - User's

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Operating instructions

Model: Touch-RF. 1 Wireless Series

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Installation Instructions

USER GUIDE VOGUE MAX SYSTEM

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

DAY/TIME Button: Selects hour, minute and day setting.

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Owner s Manual. Digital Thermostat. Non-Programmable

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

For Quick Set-Up go to Page 14

Operator: Save these instructions for future use!

Emerson Blue Easy Set 1H/1C

7-Day. Digital Thermostat. residential. & 2-cool

DAY/TIME Button: Selects hour, minute and day setting.

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

R410a Installation and fault finding training

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Control solutions Biofloor

HEAT PUMP PROGRAMMABLE THERMOSTAT

SC Installation, Operation & Application Guide

Note To The User: This product has updated features not yet mentioned in the product manual.

Motion Sensor Oscillating Heater with Digital Control

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

PORTABLE REFRIGERATOR

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

GeyserWise MAX. Thermostat instruction manual. SANS 181 compliant. All in one hot water management

SPA-QUIP LTD 3 BUTTON ELECTRONIC STANDARD SPA POOL CONTROLLER DEALER STAMP: DATE INSTALLED SERIAL NUMBER SOLD BY INSTALLED BY STARTUP TESTING

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

Elegance. SMT-700 User manual. Ver

Operating instructions Oil condensing boiler

HEAT COOL. Meets Commercial California Title 24

User Guide ems25plus. Page 1. Normal operation. Product interface

USERS GUIDE 24, 30. For installation guide see reverse of book

Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Operator: Save these instructions for future use!

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

Varenummer: Version:

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Aqua-Gen 3 INSTRUCTIONS

Samsung EHS Heat Pump Test

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

Intelligent Super Toilet AFC230 User Instruction Manual

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

VADA - Rain2Main Automatic Rainwater Controller

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

WARNING Important Safety Information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

1 For All Programmable Digital Thermostat

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Networkable Fan Coil Controller Specification and Installation Instructions

INSTRUCTION FOR THE USER THC V E OIL BLU

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

OWNER S MANUAL Venstar Inc. 08/07

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Apricus Solar Hot Water Systems

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

SH3020 USER INSTRUCTIONS

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

TRAVELMATE. Instruction Manual

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Transcription:

SolaStat -1-3 An Intelligent Technology Solution for Water Heating USER GUIDE

Table of Contents Introducing your SolaStat Controller... 1 The Display Panel... 2 Using your SolaStat Controller... 3 Trouble Shooting Guide... 8 Programming Table... 9 For technical help contact your installer or maintenance technician. Distributor Details: www.senztek.com Senztek Holdings Ltd. 2009 Version 1.0 April 2011 Table of Contents

INTRODUCING YOUR SOLASTAT CONTROLLER About your SolaStat Controller Your SolaStat Controller has a microcomputer, which intelligently and automatically controls water flow and energy inputs into your hot water system. Your SolaStat will balance water flow and energy inputs from solar, and electrical sources so you minimise your energy costs It has two main aims To make sure your hot water is being heated cost-efficiently To make sure you don t run out of hot water when you need it How does it work? Your SolaStat Controller works by measuring and comparing the temperature at three different places in the system: 1. the collector (ROOF), 2. the top of hot water cylinder (TANK) and 3. the bottom of your hot water cylinder (INLET). If the temperature at the ROOF is higher than the TANK temperature by a pre-set amount, then the pump turns on automatically to transfer heated water from your solar collector to your hot water cylinder, and replace it with cooler water from the bottom of the cylinder. This makes the hot water cylinder heat up and the collector on your roof cool down. When the temperature difference reduces to the pre-set level again, the pump automatically stops. It can also optimise the timing of heating your water, so heat is only applied to the water in your cylinder when necessary, not all the time. The SolaStat is also designed to protect your hot water system from very high or freezing temperatures. Version 1.0 April 2011 Page 1

THE DISPLAY PANEL The ROOF, TANK and INLET lights indicate which temperature is being displayed. If any of these lights flashes, the unit is in Smart Shutdown mode and SSd will be displayed. The DISPLAY PANEL shows the temperatures of the relevant sensors in 0C or 0 F. The PUMP light comes on when the pump is on (in normal or FROST operation or when the PUMP button is pressed). The PUMP light flashes when the maximum tank temperature has been reached. HWC The HWC light is not active in this model. The TOPOUT light is on when the hot water tank has reached its maximum temperature. PUMP Button Press and hold this button to turn the pump on. Repeat this again to turn the pump off. After the pump has run for ten minutes, it automatically switches off for one minute, to let air escape and prevent overheating When in Programming Mode, use this to increase the display value on the screen. HWC Button Normally used to activate a one-off heat up of the Hot water cylinder element. Note that this is not active in this model. When in Programming Mode, use this button to decrease the display value on the screen. NEXT Button Press to obtain the next displayed temperature. The FROST (and PUMP) light is on when the pump is circulating water to stop the collector from freezing. CAUTION: Do not turn the power off when the FROST light is on. TEST Button Press to test the display of the screen. 888 will be displayed and all the lights (except the PWR light) will be on at the same time for about two seconds. All the lights will then flash and the display will show the number of times the pump has been on (up to 999). Helping you to achieve Power Savings Your SolaStat helps you save power by controlling the amount of hot water that enters your tank. Your SolaStat is set to make the pump automatically turn on or turn off, depending on the temperature in the tank and at the collector. You can manually alter the amount of water entering your tank by using the PUMP button. Version 1.0 April 2011 Page 2

USING YOUR SOLASTAT CONTROLLER Reading the Display The Displayed Value lights show where the current display temperature is being read from: ROOF, TANK or INLET. To find out the temperate on the other sensor, press the NEXT button. The display light will confirm which sensor is being read. This indicates that the ROOF sensor reading is currently on display, in this case 37 0. Press NEXT to toggle between the ROOF, TANK and INLET sensors. This indicates that the TANK sensor reading is currently on display, in this case 30 0. Press NEXT to toggle between the ROOF, TANK and INLET sensors. This indicates that the INLET sensor reading is currently on display, in this case 40 0. Press NEXT to toggle between the ROOF, TANK and INLET sensors. Continued on next page Version 1.0 April 2011 Page 3

USING YOUR SOLASTAT CONTROLLER, CONTINUED Pump Activation Press and hold the PUMP button to manually operate the pump. It will circulate the water between the panel and the hot water tank. After it has run for ten minutes (on automatic or manual), the pump automatically switches off for one minute, to let air escape and prevent overheating. While the pump is operating, this light will be on. Press the PUMP button to manually pump water from the collector into the tank. You will see a number displayed on the screen. In this case, (as the ROOF light is on), it indicates that the ROOF sensor is at 80 0 Continued on next page Version 1.0 April 2011 Page 4

USING YOUR SOLASTAT CONTROLLER, CONTINUED Testing Mode Pressing the TEST button will make sure the display panel and all lights in the system are working. All the lights will stay on, and 888 will be shown for about two seconds. Then all lights will flash and the display shows how many times the pump has been activated (up to 999) for three seconds. Press the TEST button to check that all lights in the system are working For the next two seconds, all the lights come on and 888 is shown on the screen. Then, all the lights will flash (except the PWR light), and the display will tell you how many times the pump has been activated (in this case, 123 times). Continued on next page Version 1.0 April 2011 Page 5

USING YOUR SOLASTAT CONTROLLER, CONTINUED Smart Shut Down Mode Smart Shutdown is a mode that your Controller will enter to minimise damage. It can be activated when the temperature at the ROOF Sensor is less than -40 C [-40 F] or more than 162 C [324 F]. This may also occur if: there is a fault in the sensor wiring, OR the solar collector has reached a very high temperature. If Smart Shutdown mode is activated, you will see SSd on the display as shown on the screen below. SSd on the display shows the controller is in Smart Shutdown mode i.e. there is a fault condition. When SSd is displayed, the ROOF, or TANK light will be on or flashing to indicate which sensor is faulty. In this case, a faulty ROOF sensor has been detected. The Roof sensor temperature may reduce to a safe level by itself, and the unit will return to normal operation. SSd will no longer appear on the display. This is a normal condition and it is not necessary to contact your installer or maintenance technician unless SSd is on the display for more than 12 hours. Continued on next page Version 1.0 April 2011 Page 6

USING YOUR SOLASTAT CONTROLLER, CONTINUED Lockout Mode The Lockout Mode is activated when the water temperature in the collector is less than 20 C [68 F]. In this case, the collector will not contribute any useful heat, even to cold water. In this (Lockout) mode, the Controller will not turn on the pump even if the correct temperature differential is reached. However, if a frost condition is detected, this lockout mode is overridden and the pump operates to protect the system from freezing. Frost Mode The FROST value is set by your installer. It is shown on the Programming Table on Page9. This function is designed to protect your collector and hot water system from freezing and bursting. When the FROST temperature is reached, the pump will come on just enough to raise the temperature of water by 2-3 C/ 4 8 ºF. Only a small amount of warm water is needed to protect the collector and plumbing. When the unit is in Frost Mode, the FROST and PUMP lights will come on. CAUTION: Do not turn the power off when the Frost light is on. As soon as the collector reaches the FROST temperature, the FROST and PUMP lights will turn on. Version 1.0 April 2011 Page 7

TROUBLE SHOOTING GUIDE Symptom Cause Solution No operation, no display and no lights. POWER light ON but no display or corrupted display. Display on, pump not running, but sunny outside. Pump light ON Pump is running continuously Hot water drops significantly at night, yet little or no draw off be user HWC light never comes on No power/fault Power brown out (mains power not running at full voltage) Unit faulty Pump damaged or disconnected. Pump timer has turned pump off Pump is cavitating Special Installation Setting is incorrect Airlock in pipe System is reverse thermosiphoning System is in a high frost area Tank is losing heat There is no HWC function on this model. Check mains outlet. Check fuses. Switch off power while mains power is in brown out condition. Switch off power for 10 minutes, switch on power and see if unit is operating. If not, unit needs repair. Contact installer. See if pump has become unplugged Wait one minute for the pump to restart. If pump sounds like stones are passing through it, the pump may be cavitating. Contact your installer or maintenance technician Long pump times may be normal for a special installation Contact your installer or maintenance technician The non-return valve is not fitted correctly or is malfunctioning Discuss non-frost sensitive options with your energy provider Install better insulation on hot water tank Normal operation Lo on display Sensor below -20 C [-4 F] Check outside temperature Hi on display Sensor above 159 C [318 F] Check Collector has water in it SSd on display System is in Smart Shut Down mode Contact your installer or maintenance technician if the display shows SSd for more than 12 hours. Note: When power is removed, the internal timer will keep running for at least seven days. Version 1.0 April 2011 Page 8

PROGRAMMING TABLE Your installer may enter special programming information for your controller in the table below. Settings can be changed by a qualified installer or maintenance technician. Caution: incorrect settings of these values could damage the solar collector and/ or the pump. Programming Table for Adjustable Values Adjustable Values Pump Off Function The temperature difference between the Roof and the Tank that will turn the pump off Light indication Flash Pump Off value in C or F Pre-Set Value 6 C 43 F Range 1-20 C 34-68 F Installation Values C F Pump On Holdoff Timer Reheat Lower Reheat Upper The temperature difference between the Roof and the Tank that will turn the pump on How long the timer will override the element coming on (as long as the tank temperature is above Reheat Lower) The tank temperature at which the heating element will automatically start to reheat the water in your cylinder. The temperature (in the tank) at which the heating element will automatically stop reheating the water in your cylinder. Pump On value in C or F HWC on, Timer value in hours (approx) HWC slow flash Lower value in C or F HWC fast flash Upper value in C or F 12 C 54 F OFF OFF OFF 2-21 C 36 70 F 1 23 hours >23 hours = OFF <1 hour = thr 1-70 C 33.8-158 F <1ºC/ 34 F = OFF Set Holdoff Timer to thr = OFF 2-90 C 36-194 F Set Holdoff Timer to off = OFF C F (Not programmable on this model) (Not programmable on this model) (Not programmable on this model) BioSafe Topout Frost Celsius or Fahrenheit BioSafe target temperature Maximum allowable tank temperature before the pump is de-activated to protect system from overheating Minimum allowable panel temperature before the pump is activated to protect system from freezing damage. Display temperature in Celsius or Fahrenheit No lights (except Power) BioSafe value in C or F Topout on, Value in C or F Frost on, Value in C or F Temperature in either Celsius or Fahrenheit OFF 80 C 176 F 4 C 39 F C 50-70 C 122-158 F < 50 C/ 122 F = OFF 1-120 C 34-248 F <1 C/ 34 F = OFF 1-10 C 34-50 F >10 C = OFF C or F (Not programmable on this model) C F C F C/ F Version 1.0 April 2011 Page 9

Senztek NZ Ltd Senztek Australia Ltd Senztek UK Ltd