ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

Similar documents
ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

STEP 1: SELECT A NITROGEN GENERATOR STEP 2: SELECT A VENT STEP 3: SELECT MONITORING EQUIPMENT STEP 4: CONTACT ECS

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Comprehensive corrosion solutions backed by over 115 years of fire sprinkler monitoring. POTTER CORROSION SOLUTIONS

TotalPac X Single interlock SUREFIRE system

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

TotalPac X Firecycle III Preaction Double interlock system

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

TOTALPAC2 Integrated Fire Protection System

Worldwide Contacts.

White Paper. Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0

POTTER CORROSION SOLUTIONS

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

FM-200 In-Cabinet Series

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA OBSOLETE

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

EXAMPLES OF HOW TO ORDER

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

EXAMPLES OF HOW TO ORDER

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA. 319a. January 27, 2012

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

TECHNICAL DATA OBSOLETE

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Corrosion Dry Air Pak

TECHNICAL DATA. model c-2

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

MX 200. MX-200 Technical Specifications FEATURES:

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Heatless Desiccant Compressed Air Dryers

CONSTRUCTION REQUIREMENTS

PURest Air Dryer Installation and Maintenance

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

AGF Manufacturing Inc.

MX 200. MX-200 Technical Specifications FEATURES:

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Enclosed Scroll Air Compressor System SES 3-5 HP

Model DDX Deluge Valve

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

USER GUIDE. Dental Compressed Air System. Installation and Maintenance Manual For 1000 CM Series with C1 Control

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Waveguide Dehydrators

Scroll Medical Air Compressor with Premium NFPA Control Panel

White Paper. Chemical Corrosion Inhibitors - Six Reasons Why They Should Not Be Used in Water Based Fire Sprinkler Systems (June 2011)

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

PORTABLE DEW POINT MONITOR

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

SECTION AIR COMPRESSORS AND ACCESSORIES

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Chargebuster Ion Gun Installation, Operation and Maintenance

TotalPac 3 Firecyle III Deluge Remote controlled system

Refrigerated Air Dryers

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

OPEN SPRINKLER SYSTEM

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5


SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

UltraDry s Features and Benefits

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

TCR. Features: TISSUE CULTURE

TCC-34. Features: TISSUE CULTURE

Centro-Matic Automated Lubrication Systems System Controls

Deluge & Preac tion Systems

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

A. This section includes design and performance information for fire protection and suppression systems.

Instructions for Installation, Operation, Care and Maintenance

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

DISHWASHER INSTALLATION INSTRUCTIONS

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems:

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Transcription:

ECS Pre-Engineered Wall Mount PGEN-10/(PGEN-10E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Cabinet Dimensions: Weight Temperature Range: Power Supply: Power Consumption: Nitrogen/air connection: Drain connection: FM Approved 28.5 (W) X 36.5 (H) X 11.5 (D) (724mm (W) X 927mm (H) X 292mm (D)) 175 lbs (79kg) 40 F - 105 F (5 C - 40 C) 120v/1 phase/60hz (dedicated circuit) (230v/1 phase/50hz (dedicated circuit)) 24 Amps ½ NPT Female ¼ NPT Female UL 508A Listed Industrial Control Panel Ordering Information Stock Number: Replacement Filters: Replacement Membrane: General Description PGEN-10/(10E) PGEN-FKW (annual maintenance) PGEN-MW (20 year expected service life) The ECS Pre-Engineered Wall Mount Nitrogen Generator is designed for use in facilitating the Dry Pipe Nitrogen Inerting (DPNI) process for controlling oxygen corrosion in dry and preaction fire sprinkler systems. The ECS is designed for plug and play performance in a typical dry or preaction fire sprinkler system. The ECS Pre-Engineered can be used to provide DPNI for single or multiple zones depending on the number of systems, the volume of the largest system and the cumulative volume of all systems being supplied. The ECS is designed to nitrogen inert all of the zones being served within 14 days. Thereafter, the ECS continues to automatically provide supervisory nitrogen gas sufficient for pressure maintenance of the fire sprinkler system(s). The ECS facilitates the patented fill and purge breathing process in the fire sprinkler system when paired with a venting device installed on the sprinkler riser such as the ECS Protector Manual Vent (PAV-D) or the ECS Protector Dry SMART Vent (PSV-D/PSV-DE). ECS Pre-Engineered PGEN-10/(10E) 1

The ECS Pre-Engineered is a self-contained wall mounted unit that includes the following components: Steel enclosure cabinet with membrane type nitrogen generator (no nitrogen gas storage) and manual bypass Power supply - 120v/1 phase/60hz (230v/1 phase/50 Hz) Single point nitrogen/air discharge ½ NPT Oil less air compressor Hour Run Meter Cycle Counter The ECS includes the following function Indications: Bypass Alarm - Nitrogen generator is in the By-Pass mode (Flashing Indicator) Leak Monitoring - Nitrogen generator running excessively (Audible Signal) The ECS includes the following monitoring outputs: System Power (Digital Output) Bypass Mode Alarm (Digital Output) Nitrogen Generation Mode (Digital Output) Nitrogen Supply Line Pressure (Analog Output) Leak Monitoring (Digital Output) The ECS is designed to be used in conjunction with the following components as part of the complete ECS Dry Pipe Nitrogen Inerting (DPNI) system: Air maintenance device with on board adjustable regulator (recommend Victaulic Series 757, Tyco Model AMD-1 or Reliable Model A-2) Riser-mounted ECS Protector Manual Vent (PAV-D) or ECS Protector Dry SMART Vent (PSV-D/DE) The ECS can be used with the following optional equipment: ECS Protector SMART Gas Analyzer (SGA-1/1E) - one per nitrogen generator is recommended ECS In-Line Corrosion Detector (ILD-X) - monitoring at least one system is recommended Operating Performance Capacity based on NFPA 13 30-minute fill requirement of largest single system Nitrogen Quality N 2 Purity at Discharge: 98% or greater (maximum of 2.0% oxygen) N 2 Pressure at Discharge: Min of 15 psig (1 bar); Max of feed air pressure minus 15 psig (1 bar) N 2 Water Dew Point: Typically less than 70ºF ( 57ºC) Note: Model Number Min. Supply Air SCFM (L/min) Total System Capacity Gallons (Liters) Single System Capacity @ 40 psig (2.8 bar) Gallons (Liters) Single System Capacity @ 20 psig (1.4 bar) Gallons (Liters) Sound Level dba @ 10 PGEN-10/(10E) 5.7 (184) 2,000 (7,571) 560 (2,120) 1,120 (4,240) 73 When connecting an ECS Protector to an existing dry pipe/preaction fire sprinkler system, the existing fire sprinkler system(s) must be limited to a maximum leak rate of less than 3 psig (2 bar) within a 24 hour period, per system. ECS Pre-Engineered PGEN-10/(10E) 2

Installation Instructions Installation of the ECS requires five (5) steps: Step 1: Step 2: 1. Mount the cabinet on the wall in the appropriate location within the riser room 2. Bring the dedicated power supply lines to the NEMA4 power supply box in the cabinet 3. Plumb the nitrogen/air supply line to the trim work on the dry or preaction zones being served 4. Plumb the drain line to floor drain or building exterior 5. Connect Nitrogen generator output signals to BMS or fire alarm system, where applicable Mounting the Wall Mounted The ECS is designed to be mounted directly to the wall at the installation location. Several factors should be considered in choosing the proper mounting location for the nitrogen generator: Access to the power supply (dedicated circuit as per above) Access to the sprinkler riser being supplied from the nitrogen generator Clearance at the front of the unit to open the cabinet door Ability to support cabinet weight at mounting location - 175 lbs (79kg) The nitrogen generator cabinet assembly includes a mounting rail for wall mounting using standard anchors. Power Supply gen- The nitrogen generator requires a dedicated power supply line that ties into a single point in the erator cabinet. 120v/1 Phase 60 Hz Connections (230/1 Phase 50 Hz Connections) L1 N G Step 3: Plumb the Nitrogen/Air Supply Line The nitrogen/air discharge plumbing from the nitrogen generator is to be connected directly to the dry or preaction valve trim work as per standard fire sprinkler compressed air supply lines using ½ black steel, galvanized steel or copper piping. The nitrogen generator requires an in-line Air Maintenance Device (AMD) that is equipped with an on board field adjustable pressure regulator for each zone being served. The preferred AMD is the Victaulic Series 757. ECS Pre-Engineered PGEN-10/(10E) 3

Note: Step 4: Step 5: When both dry pipe and preaction fire sprinkler systems are connected to one nitrogen generator, additional equipment may be required if the fire sprinkler systems operate at different supervisory gas pressures. Plumb the Condensate Drain Line The ECS Protector will occasionally discharge a small amount of condensate water from the coalescing filters inside the cabinet. It is recommended that the ¼ drain connection be plumbed to a floor drain or building exterior. When plumbing to a drain is not feasible an evaporative collection chamber can be used. System Signals and Monitoring, where used The nitrogen generator cabinet has two (2) system signals and five (5) outputs that can be monitored by the facility s BMS or fire alarm system. The nitrogen generator is operating in the bypass mode which is activated when the bypass valve is in the fast fill position to fast fill the fire sprinkler system and the air supplied directly from the air compressor has reached a pressure of 20 psig (1.4 bar). (Flashing amber light) The nitrogen generator is equipped with a leak monitor audible signal which is activated when the nitrogen generator runs excessively. (Audible signal) The nitrogen generator cabinet includes system monitoring signals which can be monitored through a building monitoring system, if desired: Loss of Power (Form C contacts) Bypass Mode Alarm (Form C contacts) Nitrogen Generation Mode (Form C contacts) Nitrogen System Supply Line Pressure (Analog Signal) Leak Monitoring (Form C contacts) By-Pass Alarm Monitoring Output Power Monitoring Output Leak Monitoring Output Nitrogen Generation Monitoring Output ECS Pre-Engineered PGEN-10/(10E) 4

ECS PRE-ENGINEERED NITROGEN GENERATION SYSTEM (typical installation schematic) Maintenance of the The nitrogen generator cabinet contains two (2) separate cartridge filters. It is recommended that each of the filter cartridges be replaced as part of an annual preventative maintenance program. In some environments it may be necessary to replace filters more frequently. The filter replacement kit for the nitrogen generator is part number PGEN-FKW. When maintained properly the nitrogen separation membrane will provide up to 20 years of service life. The membrane replacement part number is PGEN-MW. Cartridge Filter Exchange Procedure Preliminary Steps (taking the nitrogen generator out of service) 1. Turn the power supply to the unit off 2. Close the regulated and fast fill valves on fire sprinkler system s air maintenance device(s) 3. Turn the bypass valve in the nitrogen generator to the fast fill position 4. The is designed to depressurize the inlet piping through the permeate of the nitrogen separation membrane when the nitrogen generator automatically shuts off ECS Pre-Engineered PGEN-10/(10E) 5

Coalescing Filter Cartridge Exchange Procedure The two filters with the condensate drain tube extending from the bottom of the filter housing are coalescing filters. To replace the filter cartridges follow Step 1 through Step 6. Filter Cartridge Clear Drain Tube Step 1: Step 2: Step 3: Grasp the ¼ clear drain tube on the bottom of the filter housing with the right hand. With the left hand, push upward on the grey retaining ring on the filter housing outlet fitting. This motion will allow for the ¼ clear drain tube to be removed from the fitting. Gently pull the ¼ clear drain tube downward out of the fitting and let it hang. Once the ¼ clear drain tube has been disconnected, the filter housing bowl may be unscrewed from the top portion of the filter housing which is connected to the internal system piping. Once the filter housing bowl has been removed, the filter cartridge inside is removed by first unscrewing the black retaining disc at the base of the cartridge and then pulling down on the cartridge. Discard the old filter cartridge and replace it with the appropriately marked filter cartridge from the maintenance kit by pushing up so that it fits snugly onto the receiving stepped cylinder in the upper part of the filter housing. Screw the black retaining disc back onto the central metal threaded rod. Important: HAND TIGHTEN ONLY! ECS Pre-Engineered PGEN-10/(10E) 6

Step 4: Step 5: Step 6: Step 7: Replace the filter housing bowl by screwing it onto the filter housing top. Important: HAND TIGHTEN ONLY! Reconnect the ¼ clear drain tube into the fitting on the filter housing bowl. Make sure that it fully seats in the fitting and is retained snugly. Repeat Step 1 through Step 5 for the remaining coalescing filter. The can now be placed back into service. Filter Cartridge Black Disc Return the to Service 1. Turn the power supply to the unit on 2. Open the regulated valve on fire sprinkler system s air maintenance device(s) ECS Protector Optional Monitoring Equipment ECS Protector Handheld Gas Analyzer (PHGA-1): portable handheld gas analyzer includes one-button calibration and enables user to measure nitrogen concentration at nitrogen generator cabinet or gas sampling ports on ECS venting devices ECS Protector SMART Gas Analyzer (SGA-1/1E): permanently installed near an ECS Protector Manual/SMART Vent to continuously report nitrogen gas concentration to a building information or management system; includes digital display and provides 0-5V DC or 4-20mA output signals ECS In-Line Corrosion Detector (ILD-X): installed in-line within the fire sprinkler system piping at locations most susceptible to corrosion; provides either a local push-button test/indicator or control panel monitoring ECS Pre-Engineered PGEN-10/(10E) 7

Wall Mount Total System Capacity Skid Mount Stand Alone w/separate Air Compressor PGEN-3 PGEN-5 PGEN-10 PGEN-20 PGEN-30 PGEN-40 PGEN-50 PGEN-60 675 gal 950 gal 2,000 gal 3,200 gal 6,500 gal 11,000 gal 18,500 gal 22,500 gal Single System Capacity @ 40 psi (1) 215 gal 265 gal 560 gal 950 gal 1,150 gal 1,440 gal 2,025 gal 2,900 gal Single System Capacity @ 20 psi (1) 540 gal 590 gal 1,120 gal 1,800 gal 2,300 gal 2,880 gal 4,050 gal 5,800 gal Air Compressor Integral Integral Integral Integral Separate Separate Separate Separate Size (H x W x D) 36x24x9 36x24x9 38x29x11 57x32x40 Weight 115 lbs 125 lbs 175 lbs 420 lbs 152 lbs(2) 264 lbs(2) 300 lbs(2) 300 lbs(2) (1) (2) (3) Single system capacity based on 30 min. fill requirement of largest single sprinkler system; a secondary air compressor with normally closed isolation valve can be used to meet fill requirement for larger individual systems Size and weight of nitrogen generator only, does not include separate air compressor All nitrogen generators include 1 year manufacturer s warranty per ECS terms and conditions Engineered Corrosion Solutions 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com 8