Flues and chimney systems

Similar documents
Flues and chimney systems

Air Excellent AE55SC. Technical Datasheets

Air Excellent AE45SC. Technical Datasheets

The intelligent alternative for flue gas venting systems

Air Excellent. Straightforward, effective air distribution

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Z-DENS Polypropylene Vent Systems

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Technical Guidance CE Marking of Metal Chimneys and Flues

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Twin Wall Installation Instructions And Maintenance Guide

PelletVent Multi-fuel venting system. UL 641.

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

GB162 Concentric Horizontal Vent Kit

Exhaust Duct Design Page 1 of (C)

NEW * for buildings 2-24 floors

RS Chimney Fan for Solid Fuel Applications

BDM Direct Vent systems are for use with direct vent gas fired appliances.

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

ZC Kit AGP Pellet Insert

Installation Instructions

HEAT RECOVERY AIR HANDLING UNIT

RS Chimney Fan for Solid Fuel Applications

DURAVENT POLYPRO VENTING PRODUCTS

CHIMNEYS AND VENTS CHAPTER 8

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

TWIN - GAS. Concentric flue gas system for decorative gas fires.

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

ASX7-4-IOM-6 J

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

COMMON VENTING SYSTEM SUBMITTAL SHEET

INSTALLATION AND SERVICE MANUAL

CHAPTER 8 CHIMNEYS AND VENTS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

CHAPTER 8 CHIMNEYS AND VENTS

ASX7-5-IOM-3 J

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

The ventilation appliances

CARE & INSTRUCTION MANUAL

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Condensing Gas Boilers SUGGESTED LIST PRICE (U.S.)

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

TONAdin triple-wall insulated chimney of round design. TONAtec plus air/flue chimney for all fuel types (specifically biogenic solid fuels)

Operating and assembly instructions AH Freely Suspended Insular Hood

SENSEI Series Features

Smoke extraction duct of sheet steel

AEROLINE. fast easy reliable. The sophisticated connection technology for heat pumps

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Notes on installation

GB125 Concentric Vent

INSTALLATION INSTRUCTIONS

JEREMIAS GROUP. CE MARK according to EN / 2.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES

GLASS DECORATIVE COOKER HOOD INSTRUCTION MANUAL READ AND SAVE THE MANUAL BEFORE INSTALLATION AND USE

SEPARATED COMBUSTION WARNING

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm

Installation Instructions

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Direct Exhaust Venting Kit Instructions

Vent and air piped through a side wall (concentric termination)

CI/SfB (57.5) November 2008

Falcon Undercupboard Rangehoods Installation Instructions & User Guide

INSTALLATION AND SERVICE MANUAL

SEPARATED COMBUSTION. General WARNING

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

INSTALLATION GUIDE. Isodrive / V1.0

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

Evolve 951 & Product specification pages

Venting of Gas Fired Equipment RV

User Manual for Separera 30

Centrif Duo & Centrif Duo Plus

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION INSTRUCTIONS

SEPARATED COMBUSTION. General

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Transcription:

Flues and chimney systems Complete systems overview

Table of content About us 02 Portfolio overview 03 Timeline 04 Gas flue systems 06 Chimney systems rigid single-wall 08 Chimney systems flexible single-wall 12 Outdoor systems rigid concentric 20 Roof terminals 24 Wall terminals 30 CLV systems concentric 34 CLV systems single-wall 38 Exceptional installations in cascade single-wall 42 Exceptional installations in cascade concentric 46 Parts 50 Concentric materials for boiler connections 52 Single-wall materials for boiler connections 54 Accessories 56 Non-return valves 58 Notes 60 Systems catalog 01

About us The Ubbink Centrotherm Group, with over one hundred years of experience, is a leading manufacturer of gas flue systems, ventilation ductwork and building products that enhance the watertightness and airtightness, and thus sustainability, of buildings. We are strongly represented in Europe and have sales- and production facilities in North America and China warranting local association to our clients in the Americas and Asia. Over the years, we have developed an exceptional fine portfolio and with our market knowledge and production know-how we are a reliable business partner for developing customized solutions by co-makership with our clients. We endeavor a culture of continuous improvement which is founded in a constant monitoring of standards and disciplines, 5S, waste elimination and applying our lessons learned. All is done to produce efficiently, to empower our staff and to warrant a superior product quality. Since 2009 The Ubbink Centrotherm Group was founded in 2009 to further target synergies and to improve the international organization between the Centrotherm and Ubbink companies. The aim is to grow the worldwide group business by developing new and existing markets and today there is an intense collaboration in the fields of sales, marketing, research and development, product management and operations. Since 1994 Seated in Brilon in Germany, Centrotherm Systemtechnik functions as the head office for the Centrotherm companies and is a leading solution provider in the heating and ventilation markets worldwide. Centrotherm has production facilities in Germany, U.S.A. and China. Since 1896 Seated, since its foundation, in Doesburg in The Netherlands, Ubbink is an original Dutch company with an enormous track record in the building, heating and ventilation industry. Production facilities are in The Netherlands.

Portfolio overview Classification of appliances* Type C room-sealed Configuration in boiler room (connection ducts) The air supply, combustion chamber, heat exchanger and evacuation of exhaust gases (i. e. the combustion circuit) for this type of appliance is sealed with respect to the room in which the appliance is installed. The combustion air is taken from outside the installation room. Type B non-room-sealed Appliance is intended to be connected to a flue system that evacuates the flue gases to the outside of the room containing the appliance. The combustion air is taken from the installation room. *According to new European standard for the method of evacuation of the exhaust gases; CEN/TR 1749

Boiler connection materials concentric single-wall Chimney systems rigid single-wall Chimney systems flexible single-wall 60/100 80/125 100/150 110/160 60, 80, 110, 125, 160, 200 Type C9 60, 80, 110, 125, 160, 200, 250, 315 Type C9 60, 80, 110, 125, 160 60, 80, 110, 125, 160, 200, 250, 315 Type C5 60, 80, 110, 125, 160, 200, 250, 315 Type C5 60, 80, 110, 125, 160 60/100, 80/125, 110/160 60, 80, 110, 125, 160, 200 Type C5x 60, 80, 110, 125, 160, 200, 250, 315 Type C5x 60, 80, 110, 125, 160 Type C4 Type C4 110/160 60, 80, 110, 125, 160, 200, 250, 315 60, 80, 110, 125, 160 60/100, 80/125, 110/160 Type B3 60, 80, 110, 125, 160, 200, 250, 315 Type B3 60, 80, 110, 125, 160 60, 80, 110, 125, 160, 200, 250, 315 Type B2 60, 80, 110, 125, 160, 200, 250, 315 Type B2 60, 80, 110, 125, 160 110, 125, 160, 200, 250, 315 Type B2 60, 80, 110, 125, 160, 200, 250, 315 Type B2 60, 80, 110, 125, 160

Outdoor systems rigid concentric Roof terminals Wall terminals CLV systems concentric CLV systems single-wall Type C5 or C3 Type C3 Type C1 Type C4 Type C10 60/100, 80/125, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 60/100, 80/125, 100/150, 110/160 60/100, 80/125, 100/150, 110/160 80/130, 110/160, 125/200, 160/250, 200/300 80, 110, 125, 160, 200 Type C5 Type C13 60/100, 80/125, 100/150, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 80, 110, 125, 160, 200 Type C13 80, 110, 125, 160, 200 Type C4 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 Type B3 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 Type B2 Type B2 Type B2 60/100, 80/125, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 60/100, 80/125, 100/150, 110/160 Type B2 Type B2 Type B2 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 80/125, 100/150, 110/160! All dimensions in mm.

Timeline Ubbink founded The Netherlands Start plastics production The Netherlands Ubbink France 1896 1959 1969 1976 1992 1994 Ubbink Belgium Ubbink United Kingdom Centrotherm Germany 04 Ubbink Centrotherm Group

Centrotec Sustainable Germany Centrotherm Italy Ubbink Centrotherm Group Europe Ubbink Spain 1998 2000 2003 2009 2012 2014 Centrotherm Ubbink acquired by Centrotec Germany Centrotec Asia Centrotherm USA China Systems catalog 05

06 Ubbink Centrotherm Group

Gas flue systems Gas flue systems 07

Chimney systems rigid single-wall 1 2 Description The PP rigid ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. Several terminals are at hand and depending on the model available in black, terracotta or INOX. Plastic flue pipes expand and shrink more than metal pipes as result of temperature variations. It is important that the flue pipe can move up and downwards in the terminal. In general there are two ways of installation: the combustion air is taken from the chimney or it is taken from somewhere else. In that case the chimney is just ventilated. 4 3 1 2 3 4 Terminals page 10 In the chimney page 10 System support page 11 Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 08 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 Mostly in EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 60, 80, 110, 125, 160, 200, 250, 315 Installation types C9, C5, C5x, C4, B3, B2 Features and benefits Optimal flexibility combined with maximum robustness Chimney calculations possible on request Lightweight; easy to handle and easy to shorten Less risk of injuries as result of sharp edges due to plastic materials No specialist tools needed Transparent material; easy to inspect during installation or with camera after installation Full range of products; inspection parts, adapters, terminals, extensions, bends and more Gas flue systems 09

Chimney systems rigid single-wall 1 Terminals PP terminal Complete chimney top For 60, 80 and 110 Flue pipe can move up and downwards in the terminal due temperature variations For 80 and 110 available as double version Wind angle class A45 INOX terminal Complete chimney top Outer part in INOX Flue pipe in UV-resistant PP or INOX For 60, 80, 110, 125, 160, 200, 250, 315 Wind angle class A45 2 In the chimney Chimney parts Flue pipes 15, 30, 45 and 87 bends Adaptors 10 Ubbink Centrotherm Group

Chimney systems rigid single-wall 2 In the chimney Special parts Inspection parts Spacers Damage prevention during installation Available for relevant diameters 3 System support Support parts Rigid pipes desire a firm support part at the bottom side. Small diameters; a metal support rail with PP bend Large diameters; support pipe that stands on the floor and features two gaps for a metal rail support Gas flue systems 11

Chimney systems flexible single-wall 1 Description The PP flexible ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. Several terminals are at hand and depending on the model available in black, terracotta or INOX. In general there are two ways of installation: the combustion air is taken from the chimney or it is taken from somewhere else. In that case the chimney is just ventilated. 2 4 3 1 2 3 4 Terminals page 14 In the chimney page 16 System support page 19 Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 12 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 60, 80, 110, 125, 160 Installation types C9, C5, C5x, C4, B3, B2 Features and benefits Optimal flexibility combined with maximum robustness Chimney calculations possible on request Lightweight; easy to handle and easy to shorten Less risk of injuries as result of sharp edges due to plastic materials No specialist tools needed Transparent material; easy to inspect during installation or with camera after installation Full range of products; inspection parts, adapters, terminals, extensions and more Gas flue systems 13

Chimney systems flexible single-wall 1 Terminals PP terminal Complete chimney top For 60, 80 and 110 Flex pipe is fixed at the top to prevent falling down For 80 and 110 also available as double version Wind angle class A45 Available in black and terracotta PP terminal Complete chimney top For 60 and 80 Flex pipe is fixed at the top to prevent falling down Suitable for chimneys with open top (figure A) Adjustable for chimney pot application (figure A) Wind angle class A90 Available in black and terracotta For C-type installations PP terminal Complete chimney top For 60 and 80 Flex pipe is fixed at the top to prevent falling down Suitable for chimneys with open top (figure A) Adjustable for chimney pot application (figure A) Wind angle class A45 Available in black and terracotta For B-type installations 14 Ubbink Centrotherm Group

Chimney systems flexible single-wall 1 Terminals INOX terminal Complete chimney top Outer part in INOX Flue pipe in UV-resistant PP or INOX Flex pipe is fixed at the top to prevent falling down For 60, 80, 110, 125, 160, 200, 250, 315 Wind angle class A45 A Gas flue systems 15

Chimney systems flexible single-wall 2 In the chimney Flex 60 Excellent, audible click connection for perfect connection (figure B) Easily released with a screwdriver Delivered on a roll B CENTROCERIN 16 Ubbink Centrotherm Group

Chimney systems flexible single-wall 2 In the chimney Flex 80 and Flex 110 Flex pipe with spigot pieces at approx. every 50 cm Fixation with screw swivel Delivered on a roll Gas flue systems 17

Chimney systems flexible single-wall 2 In the chimney Flex 125 and Flex 160 Unique screwing mechanism (figure C) Delivered in pieces of around 1 m Can be cut to length in 7 steps C 18 Ubbink Centrotherm Group

Chimney systems flexible single-wall 2 In the chimney Special parts Inspection parts Spacers Damage prevention during installation Available for relevant diameters Adaptors fl e x fl e x spigot flex flex socket 3 System support Support parts Flex pipes must hang at the top of the chimney. A rigid support at the bottom is also necessary. metal support rail with PP bend Gas flue systems 19

Outdoor systems rigid concentric Description 2 1 The outdoor systems are designed for installation along the outer side of a building. The PP rigid, flue ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. The INOX outer ducts have a polished finish. The combustion air is taken at the bottom of the system. Installing an optional air inlet part gives the possibility to take the air from a different location. Rain ingress is avoided due to clever design. The terminals contain a UV-resistant flue PP pipe which can freely move up and downwards to compensate elongation due to temperature variations. 4 3 1 2 3 4 Terminals page 22 System components page 22 System connection page 23 Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 20 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections, silicon for air inlet H1 (5.000 Pa) Available diameters [mm] 60/100, 80/125, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 Installation types C5, C3, C4, B3, B2 Features and benefits Complete range of products for all installations Rain water tight Aesthetically fits to each and every wall structure and color Roof tiles available Gas flue systems 21

Outdoor systems rigid concentric 1 Terminals INOX Terminal Outer part of INOX Flue pipe of UV-resistant PP Flue pipe is moving freely Terminal consists of 3-parts concentric outlet part with UV-resistant PP flue pipe concentric basic terminal part that will be connected to the flue system a clamp to connect these 2 component to a complete terminal 2 System components INOX System Extension pipes 500 and 1000 mm extension pipes Bends Available in 30, 45 and 87 Installation bracket For a firm façade installation 22 Ubbink Centrotherm Group

Outdoor systems rigid concentric 2 System components INOX Special parts Inspection part Optional air-inlet part Includes a round plate to close the opening in the wall support. Part can be placed between top and bottom of the system 3 System connection INOX Wall support Air inlet for combustion The inlet can be closed when the optional air inlet is used Wall throughput pipe Gas flue systems 23

Roof terminals Description The PP inner ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. The terminals are designed in a way that there is no icicle forming and a minimum of recirculation and wind influence. Models with cap Several configurations possible Several models available Models with open outlet The inner pipe can move up and down to compensate elongation due to temperature variations Several models avaiable Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 24 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections, silicon for air inlet side H1 (5.000 Pa) Diameters with cap [mm] 60/100, 80/125, 100/150 Diameters open outlet [mm] 60/100, 80/125, 110/160 Installation types C3, C5, C4, B2 Features and benefits Complete range of products for all installations Rain water tight Aesthetically fits to each and every wall structure and color Roof tiles available Many accessories available for complete and hassle-free installation kits Gas flue systems 25

Roof terminals 1 Models with cap Model 1 with cap Designed for type C installations Innovative internal water discharge spiral Pressure loss brought to minimum level according to standards Tool-free cap removal/terminal inspection Low circulation due to specially designed surface Very suitable for both gas and oil fueled boilers (T120) Better boiler performance; less maintenance Wind angle class A45 Available in black and terracotta Diameter 80/125 (80-80 with branch piece) Material outer pipe below roof: plastic or metal Flue pipe available in PP, ALU or INOX Model 2 with cap Designed for type B and type C installations Pressure loss brought to minimum level according to standards Better overall boiler performance; less maintenance Available in black and terracotta (except 100/150) Diameters 60/100 80/125 (80-80 with branch piece) 100/150 (100-100 with branch piece) Material outer pipe below roof: plastic or metal Flue pipe available in PP, ALU or INOX 26 Ubbink Centrotherm Group

Roof terminals 1 Models with cap Model 3 with cap Pressure loss brought to minimum level according to standards Better overall boiler performance; less maintenance Available in black Diameters 60/100 (80-80 with branch piece) Material outer pipe below roof: plastic or metal Flue pipe available in PP, ALU or INOX Special edition Featuring a flexible rain collar. Installation from the inner side of the building possible Gas flue systems 27

Roof terminals 2 Models with open outlet Model 1 open outlet Superb performance Designed for type B and type C installations Open outlet, minimum pressure loss and recirculation Available in black and terracotta Material outer pipe below roof: plastic or metal 28 Ubbink Centrotherm Group

Roof terminals 2 Models with open outlet Model 2 open outlet (INOX) Modular system End piece, clamp, basic connection part Designed for type B and type C installations Open outlet, minimum pressure loss and recirculation Better overall boiler performance Material outer pipe: INOX Flue pipe available in UV-resistant PP Fixation to the vertical terminal with clamp Gas flue systems 29

Wall terminals Description The PP inner ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. The terminals are designed in a way that there is no icicle forming and a minimum of recirculation and wind influence. The terminals can be finished with either a plastic or INOX cap. There are special telescopic models available as well as a plume management kit. Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 30 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1/P1 T120 EPDM for flue pipe connections, silicon for air inlet side H1 (5.000 Pa)/P1 (200 Pa) Diameters plastic cap [mm] 60/100, 80/125, 100/150 Diameters INOX cap [mm] 60/100, 80/125, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 Installation types C1, B2 Features and benefits Complete range of products for all configurations/installations Many accessories available for complete and hassle-free installation kits Plume management kit available Gas flue systems 31

Wall terminals 1 Models with plastic cap Eccentric cap to ensure flow back of condensate to the boiler Rain stopper to prevent rain water entering the terminal Inner and outer wall plates Designed for type C installations Open outlet, minimum pressure loss and less recirculation for better boiler performance Available as telescopic version Diameter: 60/100 Plume management kit available 32 Ubbink Centrotherm Group

Wall terminals 1 Models with plastic cap Eccentric cap to ensure flow back of condensate to the boiler Rain stopper to prevent rain water entering the terminal Inner and outer wall plates Designed for type C installations Open outlet, minimum pressure loss and less recirculation for better boiler performance Material outer pipe: plastic or metal Available in black and white For 60/100, 80/125, 100/150 Various models and configurations available and possible 2 Models with INOX cap Eccentric cap to ensure flow back of condensate to the boiler Inner and outer wall plates Designed for type C installations Open outlet, minimum pressure loss and less recirculation for better boiler performance Material outer pipe: INOX For 60/100, 80/125, 110/160, 125/185, 160/225, 200/300, 250/350, 315/400 Various models and configurations available and possible Gas flue systems 33

CLV systems concentric Description 2 4 4 1 3 The concentric CLV system is a collective chimney system especially for apartment buildings. It brings combustion air to the boilers on each floor and evacuates the individual flue through one common flue duct. The PP rigid inner ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 120 C. The outer ducts are made of galvanized steel. The system has a H1 tightness class which enables operation with positive pressure. This reduces the required diameters compared to a negative pressure system. T-pieces with 1 or 2 boiler connections (90 or 180 ) are available. Each T-piece contains a compensator to absorb the elongation and shrinking of the PP flue pipes due to temperature variations. A special ring in the T-piece ensures that condensate flows back to each individual boiler. This limits drying-out of boiler siphons which are out of operation. A telescopic pipe makes it easier to adjust the length to the height of the room. An optional inspection opening at the bottom guarantees an easy access. 1 2 3 4 Terminals/outlet parts page 36 In the chimney page 36 System support page 37 Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 34 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections, silicon for air inlet side H1 (5.000 Pa) Diameters with cap [mm] 80/130, 110/160, 125/200, 160/250, 200/300 Installation types C4 Features and benefits For multiple boiler installation (positive-pressure) Room sealed (type C) operation Maximum number of boilers depending on national regulations Number of boilers per floor depending on installation of the various T-pieces Reduced diameter for the flue pipes Telescopic pipes for easy adjustment to room height Special ring in T-piece limits drying-out of boiler siphons Gas flue systems 35

CLV systems concentric 1 Terminals/outlet parts CLV Terminal In INOX or coated steel Coating colors; black or terracotta Flue pipe in UV-resistant PP Roof parts Roof tile for pitched roofs; in INOX Rain collar for pitched roofs; in INOX Fixing plate for chimneys 2 In the chimney Extension pieces 500 mm 1000 mm Telescopic extension pieces Easy adjustment to room height Fixation with security clamp 36 Ubbink Centrotherm Group

CLV systems concentric 2 In the chimney Floor connection pieces (T-pieces) 1 connection 2 connections; 90 2 connections; 180 Special parts Inspection piece Bottom part; for siphon placement 3 System support System support Adjustable, 3 feet tripod Can be fixed to the floor Gas flue systems 37

CLV systems single-wall 1 2 4 4 Description The single wall CLV system is a collective chimney system especially for apartment and residential buildings. It evacuates the individual flue through one common duct. The combustion air comes either from the chimney or from a separate air intake terminal. The flue pipe is made from PP. The system has a H1 tightness class which enables operation with positive pressure. This reduces the required diameters compared to a negative pressure system. T-pieces with 1 boiler connection are available. Each T-piece contains a compensator to absorb the elongation and shrinking of the PP flue pipes as result of temperature variations. A special ring in the T-piece ensures that condensate water flows back to each individual boiler. This limits drying-out of boiler siphons which are out of operation. 3 4 1 2 3 4 Terminal page 40 In the chimney page 40 System support page 41 Boiler connection materials page 52 for concentric materials page 54 for single-wall materials 38 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 110, 125, 160, 200 Installation types C4, C8, C8x Features and benefits For multiple boiler installation For positive-pressure and negative-pressure installations Maximum number of boilers depending on national regulations Number of boilers per floor depending on installation of the various T-pieces Room sealed (type C) operation Reduced diameter of the flue Special ring in T-piece limits drying-out of boiler siphons PP pipes can be easily cut to adjust the length to the height of the room Gas flue systems 39

CLV systems single-wall 1 Terminal Chimney top terminal With outer part of INOX and exhaust pipe of PP or INOX 2 In the chimney Chimney parts Flue pipes 15, 30, 45 and 87 bends Adaptors Special parts Inspection parts Spacers Damage prevention during installation Available for relevant diameters 40 Ubbink Centrotherm Group

CLV systems single-wall 2 In the chimney T-pieces with 1 connection A special ring in the T-piece ensures that condensate flows back to each individual boiler Each T-piece contains a compensator to absorb the elongation and shrinking of the PP pipes as result of the temperature variations 3 System support Support parts It is extremely important to have a good support at the bottom of the chimney The smaller diameters consist of a horizontal rail with a bend Gas flue systems 41

Exceptional installations in cascade single-wall Description 1 2 The single-wall cascade system is meant for collective evacuation of flue for several boilers which are installed in cascade. The combustion air usually comes from the boiler room. The flue pipes are made in PP. The system has a H1 tightness class which enables operation with positive pressure. This reduces the required diameters compared to a negative pressure system. Remark Cascade installations can be combined with several flue system variations. The system image is a typical application and is meant as example. 3 4 1 2 3 4 Terminal page 44 In the chimney page 44 System support page 44 Cascade connection materials page 45 42 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 110, 125, 160, 200, 250, 315 Installation types B2 Features and benefits The PP pipes can be easily cut to adjust the length Optimal flexibility combined with maximum robustness Chimney calculations possible on request Lightweight; easy to handle and easy to shorten Plastic materials; less risk of injuries as result of sharp edges Transparent material; easy to inspect during installation Non-return valves available Gas flue systems 43

Exceptional installations in cascade single-wall 1 Terminal INOX terminal Complete chimney top Outer part in INOX Flue pipe in UV-resistant PP or INOX For 125, 160, 200, 250 and 315 Wind angle class A45 2 In the chimney Extension materials Flue pipes with lengths of 250, 500, 2000 and 2000 mm 15, 30, 45 and 87 bends In translucent PP Some parts available in black or white 315 variant in PPs, in grey 3 System support Support parts Small diameters; a metal support rail with PP bend Large diameters; support pipe that stands on the floor and features two gaps for a metal rail support 44 Ubbink Centrotherm Group

Exceptional installations in cascade single-wall 4 Cascade connection materials Inspection parts T-pieces Several bends with inspection caps Adaptors For the right boiler connection Available for any configuration Cascade collector For connecting boilers in cascade installation Easy to cut to length for multiple usage Easily connect multiple connectors up the required number of boiler connections Cascade end-piece With inspection end-part With siphon connection Gas flue systems 45

Exceptional installations in cascade concentric Description 1 2 The concentric cascade system is meant for the collective evacuation of exhaust gases and supply of combustion air of several boilers which are installed in cascade. The pipes are made of PP. The system has a H1 tightness class which enables operation with positive pressure. This reduces the required diameters compared to a negative pressure system. The PP pipes can be easily cut to adjust the length. Remark Cascade installations can be combined with several flue system variations. The system image is a typical application and is meant as example. 4 3 1 2 3 4 Terminal page 48 In the chimney page 48 System support page 48 Cascade connection materials page 49 46 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 110/160 Installation types C4 Features and benefits Optimal flexibility combined with maximum robustness Chimney calculations possible on request Lightweight; easy to handle and easy to shorten Plastic materials; less risk of injuries as result of sharp edges Non-return valves available Gas flue systems 47

Exceptional installations in cascade concentric 1 Terminal INOX terminal Complete chimney top Outer part in INOX Flue pipe in UV-resistant PP or INOX For 125, 160, 200, 250 and 315 Wind angle class A45 2 In the chimney Extension materials Flue pipes with lengths of 250, 500, 2000 and 2000 mm 15, 30, 45 and 87 bends In translucent PP Some parts available in black or white 315 variant in PPs, in grey 3 System support Support parts Small diameters; a metal support rail with PP bend Large diameters; support pipe that stands on the floor and features two gaps for a metal rail support 48 Ubbink Centrotherm Group

Exceptional installations in cascade concentric 4 Cascade connection materials Inspection parts T-pieces Several bends with inspection caps Adaptors For the right boiler connection Available for any configuration Cascade collector For connecting boilers in cascade installation Easy to cut to length for multiple usage Easily connect multiple connectors up the required number of boiler connections Cascade end-piece With inspection end-part Mounting brackets For a firm façade installation Gas flue systems 49

50 Ubbink Centrotherm Group

Parts Parts 51

Concentric materials for boiler connections Description The concentric materials are especially designed for condensing boilers for oil and gas. The inner exhaust pipe comes standard in PP and is suitable for a maximum flue temperature of 120 C (T120). The outer casing can come in plastic or in powder coated metal. The colors are optimized on customer need. Straight extension pipes come in 250, 500, 1000 and 2000 mm. Bends come in variations of 15, 30, 45 and 87. Straight extension pieces and 87 bends available with inspection opening. Boiler connection adapters, with or without testing points available in various types. 52 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 60/100, 80/125, 100/150, 110/160 Features and benefits Many possible variations; in dimensions, materials and connection type Full range of products; various bends, inspection parts, adapters and much more Parts 53

Single-wall materials for boiler connections Description The single-wall boiler connection materials are designed for condensing oil- or gas boilers. The flue pipe comes standard in PP and is suitable for a maximum flue temperature of 120 C (T120). Straight extension pipes come in 250, 500, 1000 and 2000 mm. Bends come in variations of 15, 30, 45 and 87. Boiler connection adapters, condensate traps, inspection parts and many other accessories are available in various types. 54 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T120 H1 T120 EPDM for flue pipe connections H1 (5.000 Pa) Available diameters [mm] 60, 80, 100, 110, 125, 160, 200, 250, 315 Features and benefits Full range of products; various bends, inspection parts, adapters, adapters with test points, condensate traps, etc. Parts 55

Accessories Accessories Universal roof tiles, with lead-free flashing Made of reinforced aluminum mesh (grid) with a mixture of modified bitumen. The material provides an all-weatherproof junction. Several tiles available; for the various roof angles and diameters Available in black and terracotta Universal, all-angles, lead-free, roof tile For all pitched roofs in range 15 55 With lead-free flashing Available in black Rain collars Available for all diameters Available in black or terracotta Flat roof flange plates Made from aluminum Versions with integrated EPDM, PVC or bitumen foils Wall plates For wall connections For ceiling connections Available for concentric and single-wall configurations 56 Ubbink Centrotherm Group

Accessories Wall plates Round versions Rubber material Split-versions for application afterwards Mounting brackets In metal, for various diameters In plastic, for 80 mm Interior finishing plates For a tidy installation Improving overall energy efficiency by taking away leakage For new and renovation applications Siphons For condensate discharge Several models available Air intake grills For B-type boiler installations Made from PP Grills Air inlet grid for boiler room For B-type (combustion air taken from the boiler room) Made from INOX Parts 57

Non-return valves Description Non return valves are necessary to prevent back flow of flue gases through boiler which is out of operation in case of over pressure systems. This means the pressure in the system is higher than the atmospheric pressure. The use of non-return valves is only allowed after a release of the boiler manufacturer. Non-return valves Valve type 80 One valve Internal syphon Trap flushes condensate when boiler is switched off 58 Ubbink Centrotherm Group

Non-return valves Valve type 110 Unique twin valve mechanism Small valve opens at P = 25 Pa, at higher pressure differences the big valve opens Trap flushes condensate when boiler is switched off Many thousands in operation during several years Valve type 160 Unique twin valve mechanism Small valve opens at P = 25 Pa, at higher pressure differences the big valve opens Internal syphon Trap flushes condensate when boiler is switched off Parts 59

? Notes 60 Ubbink Centrotherm Group

? Notes 61

Ubbink Netherlands www.ubbink.nl Ubbink Belgium www.ubbink.be Ubbink France www.ubbink.fr Ubbink Spain www.ubbink.es Ubbink United Kingdom www.ubbink.co.uk Centrotherm Germany www.centrotherm.com Centrotherm Italy www.centrotherm.it Centrotherm U.S.A. www.centrotherm.us.com Centrotherm China www.centrotherm-china.com www.ubbink-centrotherm.com 2015 - Ubbink Centrotherm Group Content is subject to change without notice Availability and configurations may differ per country UCG-2015-03-V01