UV100A Ultraviolet System

Similar documents
UVIOOAUltravioletSystem

UV100E Ultraviolet Air Treatment System

CT500 Electronic Thermostat

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

F112A,C; F113A,C Portable Air Cleaners

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

HE365A,B Powered Flow-ThroughHumidifier with JI

HE420A Steam Power Humidifier

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE

HE360 Powered Flow-Through Humidifier

Operating Manual. PRO 1000 Series EFS-01. Non-Programmable Thermostat

HE365A,B Powered Flow-Through Humidifier with

HE360A,B Powered Flow-Through Humidifier

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Home and Building Control Home and Building Control Helping You Control Your World

HE365A,B Powered Flow-ThroughHumidifier with

Programmable Load Management Thermostat

CT2800 Programmable Thermostat

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

MagicStat CT3300 Programmable Thermostat

CT2700 An Electronic Round Programmable Thermostat

Heat Recovery Ventilation Systems OWNER S GUIDE

CT1500, CT1501, CT1502, CT1503

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Model CWA200 Owner s Manual

Humidifier. Owner s Guide. English. Model Form# Hunter Fan Co Hunter Fan Company

Pressurized Filter Up to 1250 gallons

Comfort, Energy & Health Solutions. Your family. Your home. Your comfort and peace of mind. Indoor Air Quality

HEPAtech. Air Purifier. English. Owner s Manual. Model Hunter Fan Co.

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

T8131C Programmable Thermostat OWNER S GUIDE

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

PCO/UV N-Duct Model. Owner s Guide

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

T4398A,B Precision Electric Heating Thermostat

IMPORTANT SAFETY INSTRUCTIONS. IFD AIR PURIFIER Model Owner s Manual READ AND SAVE THESE BEFORE USING THIS AIR PURIFIER

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

ADORABLE Air Purifiers

T8602C Chronotherm IV Deluxe Programmable Thermostats

Portable Air Cleaner. Owner s Manual. The Science of Clean Air READ AND SAVE THESE INSTRUCTIONS. For Model 1606X Series Air Cleaner JULY

BASEBOARD MICATHERMIC HEATER

Electronic Thermostat

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

T8611M Deluxe Programmable Heat Pump Thermostats

Must be installed by a trained, experienced technician

T8600D Chronotherm IV Deluxe Programmable Thermostats

F200E Charged-Media Air Cleaner

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

T834C Heating-Cooling Thermostat

Honeywell/36. Programmable Thermostat OWNER S GUIDE

Deluxe Programmable Thermostats

Upright VACUUM CLEANER Household Type OWNER S GUIDE 2900 SERIES

OWNER S GUIDE. Electrolux Precision. Steam

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Ozone + UV Sanitation

Earn BISSELL Rewards! Register your

IMPORTANT SAFETY INSTRUCTIONS

CORDLESS HAND VACUUM USER GUIDE BOLT 1316 SERIES

AIR PURIFIER WITH GERMICIDAL UV LIGHT

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

Comfort, Energy & Health Solutions

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

(The chances are you re never going to read me) Owner s Manual. Model S10E.

owner s guide TPP201M uv germicidal air purifier TPP201M uv germicidal air purifier

IMPORTANT SAFETY INFORMATION:

DUST FREE CARBON Whole House Air Purifier

T8411R Electronic Heat Pump Thermostat

TOUCHDOWN 48 CEILING FAN

DELUXE ELECTRIC POWER BRUSH

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Drink Mixer Operation Manual

Pet Hair Eraser CORDED HAND VACUUM

MULTI REACH Stick Vacuum

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

Models 30755, & (remote included) Replacement Filter Information

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

V. (Versus ) Bare Floor Vacuum

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

T4398A,B High Performance Electric Heat Thermostats

USER GUIDE STEAM MOP STEAMREADY 1464 SERIES

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

HE120, HE160 Humidifier Installation Kit

Upright VACUUM CLEANER

Earn BISSELL Rewards! Register your

SUTTON 52 CEILING FAN

YOUR PORTABLE AIR PURIFIER

IMPORTANT SAFETY INSTRUCTIONS


owner s guide TPP230H uv air purifier TPP230H uv air purifier

Transcription:

UV100A Ultraviolet System OWNER S GUIDE 69-1381-3

American Lung Association Health House Program and Honeywell Working Together For Better Air Did you know that the average person breathes 3400 gallons(12,870 liters) of air each day * and spends 90% of that day inside?** Indoor air quality products from Honeywell are designed to help make your home more comfortable from zoning products that allow you to control the temperature in individual areas of the home to humidifiers and comfort control centers that help balance the moisture content of your indoor air. Honeywell is proud to be a partner of the American Lung Association Health House program that provides guidelines for constructing homes with improved air quality and ventilation. For more information on ways to improve the air inside your home, please visit the Health House website at: www.healthhouse.org and the American Lung Association website at: ww.lungusa.org The American Lung Association and its Health House program do not endorse products. For more information about Honeywell Indoor Air Quality products, visit: www.honeywell.com/yourhome or call: 1-800-345-6770 x531 *EPA.National Air Quality 1999 Status & Trends. **Indoor Air Pollution, An Introduction for Health Professionals, EPA, US Government Printing Office #1994-523-217/81322. IMPORTANT Please read these instructions and keep them in your records. 69-1381-3 2

! Veuillez lire et bien comprendre l installation et la maintenance.! UV100A ULTRAVIOLET SYSTEM HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE TREATMENT SYSTEM WORKS Depending on installation, your Ultraviolet System can operate as an Air Treatment System or as a Surface Treatment System. Air Treatment System Installed in the return air duct of your system, your Ultraviolet Air Treatment System kills a high percentage of airborne germs circulating through your forced air heating and cooling system. Individual results depend on careful installation and maintenance and on the actual amount of time your system fan operates. See Fig. 1. WARNING/AVERTISSEMENT Nocifs pour la peau nue et les Veuillez lire et bien comprendre l installation et la maintenance. WARNING/AVERTISSEMENT Nocifs pour la peau nue et les M22858 Fig. 1. Typical Air Treatment System installations. 3 69-1381-3

!! UV100A ULTRAVIOLET SYSTEM Surface Treatment System When installed next to the cooling coil of your system, your Ultraviolet Surface Treatment System prevents a high percentage of the growth of micro-organisms such as mold that may grow on duct surfaces, coils, and drain pans. Individual results depend on careful installation and maintenance. See Fig. 2. WARNING/AVERTISSEMENT Nocifs pour la peau nue et les Veuillez lire et bien comprendre l installation et la maintenance. WARNING/AVERTISSEMENT Nocifs pour la peau nue et les Veuillez lire et bien comprendre l installation et la maintenance. M22860 Fig. 2. Typical surface treatment installations. You can capture and minimize micro-organisms passing through your forced air system when you combine your UV System with a high-efficiency air filtration system like an electronic air cleaner. Talk to your installer about adding an electronic air cleaner to complement your UV System and provide added protection for you and your family. 69-1381-3 4

BE SURE TO READ WARNINGS AND CAUTIONS BEFORE USING YOUR UV SYSTEM WARNING UV Light Hazard. Harmful to bare skin and eyes. Can cause temporary or permanent loss of vision. Never look at bulbs while illuminated. View illumination only through light indicator located on lamp handle. To prevent exposure to ultraviolet light, disconnect power to Ultraviolet System before servicing any part of heating and air conditioning system. Do not mount device in location that allows ultraviolet light to be seen after installation. Do not attempt to bypass duct mount switch. Do not attempt to open housing; unit is sealed to prevent ultraviolet light exposure. CAUTION Personal Injury Hazard. Power supply can cause electrical shock. Disconnect power supply before cleaning or replacing ultraviolet bulb(s). Do not open base unit or lamp handle; there are no user-serviceable components inside. CAUTION Breakable Glass Hazard. Can cause personal injury. Be careful when inserting bulb(s) into lamp base. Wear protective gloves when handling bulb(s). CAUTION UV Lamp Burn Hazard. Harmful to bare skin. Can cause severe burns. Disconnect power 15 minutes before removing the ultraviolet bulb(s) 5 69-1381-3

MERCURY NOTICE This device contains mercury in the sealed ultraviolet bulb(s). Do not place your used bulb(s) in the trash. Dispose of properly. Broken Bulb Cleanup. Do not use a household vacuum. Sweep debris (phosphor/glass) into a plastic bag and dispose of properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of old bulb(s). 69-1381-3 6

HOW YOU CAN CHECK YOUR ULTRAVIOLET SYSTEM Your UV System is designed to prevent accidental contact with electrical voltage and with ultraviolet rays in the sealed unit the ultraviolet lamp does not illuminate unless the base is mounted on your forced air system duct. It is recommended that every month you verify that your ultraviolet lamp is operating. View the bulb only through the lamp light indicator on the lamp handle. See Fig. 3. Do not attempt to look into the duct at the illuminated bulb(s). LAMP LIGHT INDICATOR M22840 Fig. 3. Lamp light indicator. 7 69-1381-3

HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to maintain peak effectiveness of your air treatment or surface treatment system. Replace the ultraviolet bulb once a year. Quarterly Bulb Cleaning Bulb cleaning is recommended as routine maintenance four times a year or every three months. Use the UV Bulb Cleaning Reminder Schedule, Fig. 4, to help establish and track your regular cleaning schedule. UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month), (year) YEAR J F M A M J J A S O N D M13516A Fig. 4. UV bulb cleaning reminder schedule. To clean your bulb(s): 1. Disconnect the power to your heating and cooling system. 2. Unplug or turn off power to your UV System and allow the bulb(s) to cool for at least 15 minutes. 69-1381-3 8

3. Rotate your lamp handle counterclockwise and gently pull the lamp handle to remove the bulb. See Fig. 5. M22842 Fig. 5. Remove lamp bulb. 4. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with glass cleaner. If you touch the lamp glass with your hands, be sure to clean the area of any oils left from bare hands. See Fig. 6. M22844 Fig. 6. Clean glass with soft cloth. 5. Also wipe away any dust that may have collected between the lamp light indicator on the base and the black bulb base. See Fig. 7. LAMP LIGHT INDICATOR BASE M22846 Fig. 7. Wipe lamp light indicator base. 9 69-1381-3

6. Dry bulb with a clean, dry cloth. 7. Insert the bulb into the base with the lamp light indicator at the eleven o clock position. Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base. See Fig. 8. M22848 Fig. 8. Position bulb for insertion back into the lamp base. 8. Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 9. M22850 Fig. 9. Snap bulb into place. 69-1381-3 10

9. Reconnect power to your UV System. 10. Verify that your ultraviolet bulbs are operating by viewing only through the lamp light indicator on the lamp handle. Never look directly at your bulb while it is illuminated. 11. Reconnect power to your heating and cooling system. Bulb Replacement Annual replacement of the bulb in your ultraviolet lamp is required to maintain effectiveness. 1. Obtain the correct replacement bulb/handle assembly or replacement bulb for your unit. See Table 1. Table 1. Select a Replacement Bulb/Handle Assembly or Replacement Bulb. Unit Description UV100A1000 Air Treatment System UV100A1018 Air Treatment System UV100A1059 Surface Treatment System UV100A2008 Surface Treatment System Replacement Bulb/ Handle Assembly UC100A1005 UC100A1013 (twin pack) UC100A1054 UC100A1054 SnapLamp Replacement Bulb UC18W UC36W (two needed) UC36W UC36W 2. Disconnect the power to your heating and cooling system. 3. Unplug or turn off power to your UV System and allow lamps to cool for at least 15 minutes. 4. Rotate the lamp handle counterclockwise and gently pull the lamp handle to remove the bulb. See Fig. 5. 11 69-1381-3

5. If you have a SnapLamp handle, follow steps 5 and 6; otherwise, proceed to step 7. Grasp the SnapLamp handle in one hand and the lamp glass in the other and pull straight apart. See Fig. 10. M22852 Fig. 10. Disconnect lamp glass from SnapLamp handle. 6. Insert the new lamp glass into the SnapLamp handle by aligning the key and pushing straight together. See Fig. 11. M22854 Fig. 11. Replace lamp glass in SnapLamp handle. 7. Insert the bulb into the base with the lamp light indicator at the eleven o clock position. Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base. See Fig 8. 8. Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover. See Fig. 9. 9. Reconnect power to your UV System. 10. Verify that your ultraviolet bulb is operating by viewing only through the lamp light indicator on the lamp handle. Never look directly at your bulb while illuminated. 11. Reconnect power to your heating and cooling system. 69-1381-3 12

Limited Warranty Honeywell warrants this product, excluding bulbs, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell s option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods Dock 4 MN10-3860 1885 Douglas Dr N Golden Valley, MN 55422 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr N MN10-1461, Golden Valley, MN 55422 or call 1-800-468-1502, Monday- Friday, 7:00 a.m. to 5:30 p.m., Central time. In Canada, write Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr, ON15, Scarborough, Ontario M1V4Z. 13 69-1381-3

69-1381-3 14

15 69-1381-3

Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 yourhome.honeywell.com U.S. Registered Trademark 2005 Honeywell International Inc. 69-1381-3 G.H. Rev. 04-05