Operation and Maintenance Manual

Similar documents
RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

R100 Oil-Less Refrigerant Recovery Unit

OPER LV Wheeler Way

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES

Refrigerant Recovery Unit, Model RRU134

OPERATING INSTRUCTIONS

Refrigerant Recovery Machine. Model No Operating Manual

OWNER S MANUAL (English)

OPERATION & MAINTENANCE MANUAL TX600

OWNER S MANUAL (English)

OPERATING INSTRUCTIONS

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

OPERATING INSTRUCTIONS

OPERATION & MAINTENANCE MANUAL TC670

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

REFRIGERANT RECOVERY SYSTEMS

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

OPERATION & MAINTENANCE MANUAL RHS680

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

OPERATION & MAINTENANCE MANUAL AC860

OWNER S MANUAL (English)

Additional users operating manual

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Caresaver Universal Refrigerant Recovery Unit

347002K/177002K/34900

OPERATION & MAINTENANCE MANUAL AC880

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

SECTION 50 - CAB CLIMATE CONTROL

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

B. A. T. Basic Appliance Training

YELLOW JACKET Recovery Machines for every refrigerant, every size system

Ariazone 601HD Refrigerant Recovery&Recycling unit

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Installation Instructions

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

R E D I C O N T R O L S

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

User manual Flushing device VAS 6337/1a

Installation Instructions

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Installation Instructions

Condensing Unit Installation and Operating Instructions

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

T-Series Air Conditioner T15 Model

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

OPERATING MANUAL. Model 34134Z. Refrigerant Unit Recover, Recycle, and Recharge

Residential Piping and Long Line Guideline

Service Manual. Models 17700/17701/17703 Recovery/Recycling/Recharging Unit For R-12 Only

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Operating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Ariazone 5001 HFO-1234yf

Installation and Operation Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-Series Air Conditioner T20 Model

OPERATION MANUAL COPYRIGHT APPION INC - ALL RIGHTS RESERVED

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Operator s Manual. Histology Bath

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Air Conditioning Operation and Troubleshooting Matt Dunham

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION & OPERATION MANUAL

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

CC Series VACUUM PUMPS

Operating Manual Manual de Operación Manuel d utilisation

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Transcription:

Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which it was designed. Warranty does not cover items that have been altered, abused or returned solely in need of field service maintenance. If found defective, we will either replace or repair at our option products returned within 15 months of factory shipment. All returns must be return freight prepaid. The following steps must be taken by you or your wholesaler before the unit can be returned: 1. Call our technical service personnel at (800)769-8370 to see if the problem can be resolved over the phone. 2. Obtain an RMA number from Ritchie Engineering. 3. Fax a copy of the original invoice to (952)943-1140. If at any time after the warranty period you have problems with your YELLOW JACKET recovery unit, call our technical service department for help in selecting the correct replacement parts, or arrange for us to make the repair at a reasonable cost. RecoverX Oil-Filled Hermetic Refrigerant Recovery System Ritchie Engineering YELLOW JACKET Products Division 10950 Hampshire Avenue South Bloomington, MN 55438 USA Phone: 952-943-1333 Phone: 800-769-8370 Fax: 952-943-1605 e-mail: custserv@yellowjacket.com Web Site: www.yellowjacket.com Operation and Maintenance Manual Printed in U.S.A. Part #151053_D

Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4 Push-Pull Liquid Recovery 5-6 Care and Maintenance Change-over Procedure 6-7 Compressor Maintenance 7-8 Recovery Tips & Techniques 8 Troubleshooting Guide 9 Parts Location and List 10 RecoverX Wiring Diagram 11 Technical Data 11 Important Notices To Purchaser 11 Warranty Information 12 General Safety Instructions 1) Know your equipment. Read and understand the operation manual and the labels affixed to the unit. Learn its applications and limitations, as well as the specific potential hazards of your equipment. 2) Use the correct hoses. Use only hoses designed for handling of refrigerants. The hoses should be the minimum length required to do the job and be equipped with a shut-off device (such as the compact ball valve) located within 12 inches of the end to reduce the likelihood of refrigerant leaks to the atmosphere. There is a YELLOW JACKET hose for almost every type of refrigerant. See your distributor for more information. 3) Ground all equipment. Plug this device into properly grounded receptacle with an appropriate plug. 4) Do not pressure test with compressed air. Some mixtures of air and refrigerant have been shown to be combustible at elevated pressures. 5) Avoid dangerous environments. Use with sufficient ventilation to keep operator exposure to a minimum. Always perform recovery in well ventilated areas. Use this equipment only in locations with mechanical ventilation, providing at least four air changes per hour, or the equipment should be placed 18 above the floor. This equipment should not be used near open containers of gasoline or any other flammable liquid. Do not allow refrigerants to contact open flame. Refrigerant decomposition in flame results in phosgene gas. Breathing phosgene gas can be fatal. 6) Always wear safety goggles and gloves. Personal protective equipment should be worn to protect operator from frostbite. 7) Use caution when connecting or disconnecting. Improper usage may result in refrigerant burns (frostbite). Wiring Diagrams Technical Data Compressor: 1/6 HP hermetically sealed reciprocating Power Source: 115Vac 60 Hz Amperage: Run Load Amps: 1.5 Full Load Amps: 2.0 Locked Rotor Amps: 8.0 Size: Height: 12.5" Width: 12.4" Depth: 19.3" Weight: 29 lbs. Important Notice To Purchaser Check for damage immediately. Prior to shipment, all YELLOW JACKET RecoverX Recovery Systems are completely tested and inspected to assure compliance with Ritchie Engineering factory specifications. If the recovery system carton is damaged, check contents immediately. Note damage on shipper s Bill of Lading and have shipper sign statement. Notify the carrier immediately of the damage to arrange inspection of the recovery system and packaging. The CARRIER ALONE is responsible for handling and settling your claim. Ritchie Engineering will cooperate in assessing damage if the recovery system is returned to the factory prepaid. Carton contents include: RecoverX Series Recovery System Owner s manual Warranty registration card To validate warranty, mail registration card within 10 days. 11

Parts Location and List If a major leak occurs, proceed immediately to a well ventilated area. range from 40 o (4 o C) to 120 o F (49 o C). Do not operate unit in a wet location. 8) Disconnect recovery machine from power before servicing. An electrical shock hazard is present when the unit is disassembled. 9) Repair damaged parts. Do not operate the recovery machine with a defective part. Repair unit to proper operating conditions. 10) Use recommended accessories. Follow the instructions that accompany all accessories. Improper use of accessories may damage equipment or create a hazard. 11) Use the RecoverX only with the correct refrigerants. (See specifications for a complete list of compatible refrigerants.) 12) Operate unit within the design parameters. The RecoverX was designed to operate in a temperature 13) Caution: All refrigerant hoses, recovery tanks, refrigerant lines, the RecoverX, and other vessels containing refrigerants should be handled as if under high pressure. When opening a tank with refrigerant in it, open valves slowly to prevent release of refrigerant if valves are damaged. 14) Caution: To avoid cross contamination of refrigerant and potential leakage to the atmosphere, the proper hoses and fittings should be used and checked for damage. 15) Caution: To avoid overfilling the refrigerant cylinder, read and follow the manufacturer s recommended filling instructions for the refrigerant being recovered. To prevent the risk of fire DO NOT use an extension cord longer than 25ft (7.6m) and a minimum of 16 AWG (1.276mm 2 ). 95700 Parts Item # Part# Description Item # Part# Description 10 1 95444 Case, Front 9 95178 4" Fan Motor Assembly 2 95445 Case, Rear 10 95460 Bypass Valve 3 95446 Case Half (both halves) 11 95463 Compressor Inlet Assembly 4 95447 Case, Cord Wrap 12 95464 Discharge Hose Assembly 5 93394 1/4" Flare Cap & Strap 13 95473 Compressor Discharge Assembly 6 95549 High Pressure Gauge Panel Mount 7 95550 Low Pressure Gauge Panel Mount 14 95423 High Pressure Switch 15 95163 Check Valve (2) 1/4" mfl x 1/4" mfl 8 95450 Condenser Coil 16 95472 Service Compressor N/A 95158 Start Relay N/A 95465 Operation Manual System Overview The RecoverX offers significant flexibility to meet your refrigerant handling needs. Careful handling of refrigerant is an important part of servicing air-conditioning equipment. Specific regulations apply to refrigerant handling. Familiarize yourself with these regulations. Refrigerant recovery is used to remove the working fluid of an air conditioning or refrigeration system. The refrigerant is transferred to a holding tank. For field service, this tank is normally a portable refrigerant tank. The refrigerant is subsequently transferred to a large collection tank when the service technicians return to the office at the end of the day. Because the refrigerant is combined in a large tank, every technician must ensure of which refrigerant is in each tank. Your company procedures should help you determine this. Mixing refrigerants can contaminate a large volume of refrigerant. Use care when recovering refrigerant into a portable tank. As stated in the warnings, overfilling a tank can be extremely dangerous. The best method for monitoring tank level is a scale that continually monitors the weight of the tank. The RecoverX is designed for recovery of vapor refrigerant only. It can also be used for the traditional push-pull method of recovering liquid refrigerant. Liquid refrigerant will flush the oil from the compressor sump and cause the compressor to seize or could damage the compressor valve plates. 3

CAUTION: This unit IS NOT designed for the direct recovery of liquid refrigerant. Liquid refrigerant will flush the oil from the compressor sump and cause the compressor to seize or could damage the compressor valve plates. Operating Guide The RecoverX is a VAPOR ONLY recovery unit. It will not tolerate liquid. Use your RecoverX to pull vapor refrigerant directly out of the system and transfer it into your recovery cylinder. Vapor recovery can be done by connecting to the low pressure system suction service port (Vapor port) side of the system. See diagram on following page. Follow the steps below: 1) Ensure the recovery unit Power Switch is off ( ) and power to the system to be serviced is off. 2) Connect the recovery unit, manifold set, the system to be serviced, and the recovery tank as shown on page 5. 3) Open the valves on the recovery cylinder. 4) Turn the Bypass Valve to OPEN.. ( ) 5) Turn the Power Switch on 6) Turn the Bypass Valve clockwise to CLOSED. 7) Slowly open the low pressure valve on the manifold set, regulating the Restart Procedure If the recovery unit was stopped during operation, it may be necessary to balance the internal pressures before the unit will start. Turn Power Switch off ( ). Stop refrigerant flow to the suction port on the unit. 4 The RecoverX is designed for recovery of vapor refrigerant only. It can also be used for the traditional push-pull method of recovering liquid refrigerant. suction pressure at no more than 40 psi. This will prevent the compressor from stalling. 8) Monitor the manifold low-pressure gauge. Once the pressure has reached the required vacuum level, recovery is complete. 9) Turn the Power Switch off ( ). 10) Wait five (5) minutes to ensure the pressure does not rise. 11) If the pressure rises above the required vacuum level, continue the recovery at Step 4. 12) If the pressure remains below the required level, close the low-pressure valve on the manifold set and the recovery tank valves. Disconnect the hoses. 13) Because oil can be removed from the HVAC system during recovery, the Oil Drain port should be drained after every usage. By draining this oil into a measuring device, it can be determined how much refrigerant oil was removed from the HVAC system. See the Oil Level Check procedure on page 7. Open Bypass Valve. Wait 30 seconds. Restart the recovery unit. Close Bypass Valve. Resume normal vapor recovery. Troubleshooting Guide Problem Possible Cause Solution Compressor will not Power cord not plugged in Plug in to energized 110V receptacle start 110V receptacle not energized Check 110V receptacle for power Unit starts but stops after a short period Compressor starts but trips the circuit breaker upon start up Unit will not perform liquid push-pull recovery High Pressure Switch not reset Reduce discharge pressure and reset. If switch will not reset, check discharge for restrictions or schrader core not fully depressed. Circuit Breaker is tripped Reset circuit breaker Defective system switch Replace switch Restriction on the discharge port Open valve on recovery tank Ensure schrader core on discharge port is fully depressed Check for other restrictions High differential pressure across compressor Liquid refrigerant present in the sump of the compressor Compressor oil level is too low or too high. System to be serviced does not allow liquid recovery UL Certified Rates to ARI Standard 740-98 Other Refrigerants: Turn Bypass Valve to OPEN. Remove liquid refrigerant from sump of compressor. Check oil level and add or drain if necessary Use Vapor Recovery method R12 R134a R22 R500 R502 Vapor lbs./min.24.20.29.24.24 Liquid lbs./min N/A N/A N/A N/A N/A Push-Pull lbs./min 10.4 9.3 8.8 9.6 7.6 Vacuum Level 15 in. Hg 15 in. Hg 15 in. Hg 15 in. Hg 15 in. Hg YELLOW JACKET RecoverX is approved for use with the following refrigerants which has not been certified for a particular recovery rate. R-12, R-134a, R-401C, R-406A, R-500, R-401A, R-409A, R-401B, R-412A, R-411A, R -407D, R-22, R-411B, R-502, R-407C, R-402B, R-408A, R-509. 9

Compressor Maintenance, cont. 5) Uncap the suction port. The compressor oil will come out of the drain port. Low pressure compressed air can be applied to the suction port to assist the draining process. 6) Refill the oil sump with 7 ounces of POE refrigerant oil. 7) Return the machine to a flat position and check the oil level as described previously. Vapor Recovery Diagram Recovery Tips and Techniques Here are a few time saving techniques to help you on your next job: 1) Use the shortest hoses possible and when possible avoid hoses with schrader depressors. This will help assure the fastest and quickest recovery possible. 2) Know what kind of refrigerant you are going to recover and the amount. You need to know what kind to avoid contamination. More importantly you need to know how much refrigerant you plan to recover. This will help you avoid overfilling your recovery cylinder which can have disastrous results. 3) If you plan on recovering large amounts of refrigerant (20lbs or more) it would be a good idea to use the push-pull method. Note: This process requires you to switch hoses to finish recovering the remaining vapor. See the Push Pull Liquid Recovery section of this manual. 4) Protect your RecoverX by using an in-line filter drier. Failure to use a suction filter drier can cause damage to your compressor. 5) Recovery machines are not vacuum pumps. For proper evacuation use your YELLOW JACKET vacuum pump. To speed up the evacuation process try using your TITAN manifold and core removal tool (P/N 18975). For more information contact your local YELLOW JACKET wholesaler. Push-Pull Liquid Recovery The Push-Pull Liquid Recovery method is used for transferring large volumes of liquid refrigerant. The RecoverX pulls vapor from the recovery cylinder and produces high pressure discharge gas that pushes liquid out of a HVAC system into a recovery cylinder (see page 6 for diagram). Some systems may not allow push-pull liquid recovery. If any of the following conditions apply to your recovery job, proceed directly to the Vapor Recovery Method. Equipment contains less than 8 pounds of refrigerant. Equipment is a heat pump or other unit with a reversing valve. Equipment has an accumulator between the service ports used in liquid recovery. Liquid refrigerant has migrated and the location of the refrigerant is not known. The refrigerant system does not allow for a solid column of liquid refrigerant to be formed. When using push-pull recovery, the RecoverX will not recover to the required vacuum level in the recovered system. Use a sight glass to determine when the liquid is being pushed into the recover tank. When liquid refrigerant is no longer visible, go to the Vapor Recovery section of this manual for further instructions. The hose connections for push-pull liquid recovery are shown on page 6. Perform the following steps for push-pull liquid recovery: 1) Ensure the recovery unit Power Switch is off ( ) and the power to the system to be serviced is also turned off. 2) Connect the recovery unit, the system to be serviced, the manifold set, and the recovery tank as shown on page 6. 3) Open the valves on the recovery cylinder. 4) Turn the Bypass Valve to OPEN.. ( ) 5) Turn the Power Switch on 5 RecoverX Front View 8

Push-Pull Liquid Recovery, cont. Change-over Procedure, cont. 6) Turn the Bypass Valve to CLOSED. 7) Slowly open the low pressure valve on the manifold set. Manually regulate the suction pressure at no more than 40 psi. This will prevent compressor from stalling. 8) Monitor the sight glass. When there is no longer significant liquid refrigerant passing through the sight glass, pushpull liquid recovery is complete. Push-Pull Diagram Change-over Procedure Different types of refrigerant and refrigerant oil should not be mixed in the recovery unit. If recovering a different type of refrigerant, the recovery unit must be completely evacuated. Follow these steps to pump down the system for use with another refrigerant. 1) Place a cap on the suction port of the unit and turn the Bypass Valve to CLOSED. Turn the unit on and run it for two minutes. 2) Apply 10-30 psig pressure of inert gas such as nitrogen to the suction port. 6 9) Close the low pressure gage on the manifold set. 10) Turn the Power Switch off ( ). 11) Close the valves on the recovery tank. Proceed to the Vapor Recovery procedure to remove the remainder of the refrigerant and to evacuate the system to the required vacuum level. 3) Turn the Bypass Valve to OPEN.. ( ) 4) Turn the Power Switch on 5) Turn the Bypass Valve to CLOSED and run for 15 seconds. Note: The inert gas will enter the recovery cylinder. This small amount of non-condensable gas will be removed during the reclamation process. 6) Turn the Power Switch off ( ). 7) Close all valves and remove the hose from the recovery tank. 8) Connect the hose to a vacuum pump. 9) Run the vacuum pump for at least 10 minutes to remove the remaining refrigerant and non-condensable gas. Compressor Maintenance OIL LEVEL CHECK This unit has been factory charged with 7 ounces POE oil. Check the compressor oil before and after each use. An overfilled oil sump can overload the compressor. Too little oil can cause the compressor to seize. CAUTION: The recovery unit is under high pressure. Do not remove the cap on the compressor oil port without following this complete procedure! To check the oil level: 1) Place a cap on the suction port of the unit and close the bypass valve. Turn the unit on and run it for two minutes. 2) Slowly remove the brass cap from the compressor oil port. If pressure is present, continue running the unit until there is no pressure on the port. 3) Place a small catch device under the open drain port or attach a hose and direct it toward a catch device. 4) With the machine on a flat surface, uncap the suction port. Excess oil will 10) Check the compressor oil for contamination and proper level. Add or change oil if needed. 11) Unit is ready for use with another refrigerant. come out of the oil drain port. Low pressure compressed air can be applied to the suction port to assist the draining process. 5) Allow excess oil to drain into the catch device. 6) If no oil comes from the drain, add one ounce of refrigerant oil to the compressor. Check the oil level. Once a small amount of oil comes from the drain, the oil level is correct. If not, repeat this step. 7) Replace the brass cap on the oil drain port. 8) Ensure the unit is working properly before using it to recover refrigerant. COMPLETE OIL CHANGE The compressor oil should be changed at least every six (6) months (more often if unit is used frequently). The oil may need to be changed after servicing a system that had a compressor burn out or high contamination levels. To change the compressor oil: 1) Place a cap on the suction port of the unit. Turn the unit on and run it for two minutes. 2) Remove the brass cap from the compressor oil port 3) Place a catch device under the open drain port or attach a hose and direct it toward a catch device. 4) Tilt the machine on its side as shown. This allows most of the oil to drain out of the recovery unit. 7