Actions to Control Emission of HFCs in Japan

Similar documents
Transitioning to Alternatives and Challenges in Japan

Challenges and responses in refrigerant conversion

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Transitioning to Alternatives and Challenges in Japan

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Japanese market and issue of Heat Pump Kenji Matsuda

Member Briefing JAPAN

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Natural refrigerant trends in EU, Japan & North America

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Policies and Measures for HCFCs in Japan

Refrigerants & Cooling in renovation buildings

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

The natural solution for domestic refrigeration

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Refrigerant and Energy Regulations Update

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Chapter 2. Alternatives to HCFCs and their Characteristics

FACT SHEET 6 Transport Refrigeration

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Guidance for Stationary Refrigeration & Air-Conditioning

Information Guide Maintenance and Refrigerant Regulations. Issue 35

FACT SHEET 9 Large Air-Conditioning (air-to-air)

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

Global Solutions for Ammonia Industrial Refrigeration

The Current Path of Refrigerants

Evaluation of HCFC Alternative Refrigerants

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Development of centrifugal chiller and heat pump using low GWP refrigerant

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

Low GWP alternative refrigerants to R404A

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Update on Refrigerant Blends

Overview of New Refrigerants and Expected Market Trends

Refrigerant Rule Update

PURPOSE OF THE PROCEDURE

Honeywell Refrigerant Update

Chapter 10. Refrigeration and Heat Pump Systems

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

Study of R161 Refrigerant for Residential Airconditioning

Chillers for High Ambient Conditions: What Technologies and Fluids?

Effectively Managing the Transition to Lower GWP Refrigerants

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Responsible Care Product Stewardship for Refrigerants

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

International New Technology and Refrigerant Symposium

Low GWP Refrigerants for Air Conditioning Applications

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Hydrocarbons as refrigerants

Refrigerant & Energy Regulations Update

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

Natural Refrigerants.

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

HFCs or the Old Refrigerants - what is the best Choice?

Development of centrifugal chiller and heat pump using low GWP refrigerant

History of Kobe Symposium And Global Issues of the HVAC Industry

ON SUBSTANCES THAT DEPLETE

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Refrigerant Sustainable Future IZW e.v. Technische Universität Dresden

Making equipment decisions

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Brazed Plate Heat Exchanger for CO Applications

This presentation is posted for public use. ACEEE does not endorse any product or service.

New Refrigerants & Selecting Capital Equipment

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Methodological tool Calculation of baseline, project and leakage emissions from the use of refrigerants

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

The impact of legislation and trends for the industry

REFRIGERANT PROCEDURE

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Navigating a changing refrigerants market

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Hall 7A. Chillventa Specialist Forums 2018 Chillventa Fachforen NürnbergMesse, Arbeitstitel, Datum 1

Development and Handling of Hydrocarbon Air-conditioners The Godrej Experience

Trends and Perspectives in Supermarket Refrigeration

HFO-1234yf Performance in a Beverage Cooler

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Ammonia. Background on ammonia as a refrigerant

Natural Refrigerant Market Trends

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

CHAPTER 1 INTRODUCTION

Product Offering for 2017

Risk Assessment of Mildly Flammable Refrigerants

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

Transcription:

Actions to Control Emission of HFCs in Japan Implementation of the Act on Rational Use and Proper Management of Fluorocarbons Kazuhiro Sato JRAIA (the Japan refrigeration and Air Conditioning Industry Association)

0. Timeline 2 Regulation Published(OJ) Implementing Acts published Guideline published Entry into force June 2013 Oct- Nov 2014 Dec. 2014 1 st Apr. 2015 Nov. 2014: MOP26 In Paris Dec. 2014: COP20 In Lima, Peru Dec. 2015: COP21 In Paris

1. Direction of measures for HFCs in Japan 3 Issues 1. Rapid increase of HFCs emission 2. Low recovery rate : Approximately 30% 3. Leakage in use of equipment : 13 to 17% per year in 2009 4. Development and commercialise equipment with low GWP or no HFC refrigerants 5. Global movements to enhance control of high GWP Direction of measures Comprehensive measures over whole life cycle from production to destruction of CFCs/HCFCs/HFCs Needed. 1. Manufacturers and Importers of HFCs Phase-down of HFCs 2. Manufacturers and Importers of Equipment Acceleration of equipment using low GWP or no HFC refrigerants 3. Owners of Equipment Prevention of HFCs leakage from commercial refrigeration equipment in use 4. Refrigerant charge by registered operators, Reclamation by approved operators Publication of the Revision of Fluorocarbons Recovery & Destruction Law in Jun 2013

1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 Mt (CO 2 eq.) Kt (weight) 1. Direction of measures for HFCs in Japan 4 350 300 250 JFMA published data 70 60 50 200 150 CFC 40 30 100 20 50 0 HCFC HFC 10 0 CFC, HCFC and HFC Consumption in Japan

1. Direction of measures for HFCs in Japan 5 Issues 1. Rapid increase of HFCs emission 2. Low recovery rate : Approximately 30% 3. Leakage in use of equipment : 13 to 17% per year in 2009 4. Development and commercialise equipment with low GWP or no HFC refrigerants 5. Global movements to enhance control of high GWP Direction of measures Comprehensive measures over whole life cycle from production to destruction of CFCs/HCFCs/HFCs Needed. 1. Manufacturers and Importers of HFCs Phase-down of HFCs 2. Manufacturers and Importers of Equipment Acceleration of equipment using low GWP or no HFC refrigerants 3. Owners of Equipment Prevention of HFCs leakage from commercial refrigeration equipment in use 4. Refrigerant charge by registered operators, Reclamation by approved operators Publication of the Revision of Fluorocarbons Recovery & Destruction Law in Jun 2013

Recovered amount (metric-t) 1. Direction of measures for HFCs in Japan 6 8000 Recovery under Conventional Laws 7000 6000 5000 4000 3000 2000 1000 EOL Auto HFC EOL Auto CFC Fridge Insulation Fridge Ref EOL Residential AC EOL AC&R Repair Other AC&R EOL 0 2007 2008 2009 2010 2011 2012 Significant amount has been recovered, but recovery ratio is around 30%.

1. Direction of measures for HFCs in Japan 7 Issues 1. Rapid increase of HFCs emission 2. Low recovery rate : Approximately 30% 3. Leakage in use of equipment : 13 to 17% per year in 2009 4. Development and commercialised equipment with low GWP or no HFC refrigerants 5. Global movements to enhance control of high GWP Direction of measures Comprehensive measures over whole life cycle from production to destruction of CFCs/HCFCs/HFCs Needed. 1. Manufacturers and Importers of HFCs Phase-down of HFCs 2. Manufacturers and Importers of Equipment Acceleration of equipment using low GWP or no HFC refrigerants 3. Owners of Equipment Prevention of HFCs leakage from commercial refrigeration equipment in use 4. Refrigerant charge by registered operators, Reclamation by approved operators Publication of the Revision of Fluorocarbons Recovery & Destruction Law in Jun 2013

1. Direction of measures for HFCs in Japan 8 Issues 1. Rapid increase of HFCs emission 2. Low recovery rate : Approximately 30% 3. Leakage in use of equipment : 13 to 17% per year in 2009 4. Development and commercialised equipment with low GWP or no HFC refrigerants 5. Global movements to enhance control of high GWP Direction of measures Comprehensive measures over whole life cycle from production to destruction of CFCs/HCFCs/HFCs Needed. 1. Manufacturers and Importers of HFCs Phase-down of HFCs 2. Manufacturers and Importers of Equipment Acceleration of equipment using low GWP or no HFC refrigerants 3. Owners of Equipment Prevention of HFCs leakage from commercial refrigeration equipment in use 4. Refrigerant charge by registered operators, Reclamation by approved operators Publication of the Revision of Fluorocarbons Recovery & Destruction Law in Jun 2013

2. Scope 9

2. Scope Expand Scope Reuse (1) HFCs Phase-down Low GWP HFCs Natural Refrigerant HFCs (5) Proper destruction and recycle Manufacturers of products containing HFCs Refrigerator Insulators Air conditioner Dust blowers (3) Reduction of refrigerant leakage from commercial equipment in use Periodical check (2) Promotion of low- GWP/non-fluorocarbons for designated products Products with alternatives Maintenance Users of products Report of leakage 10 Obligation of destruction Approved destructors/recycle Registered fillers/recovery operators (4) Proper refill and recovery

Revised act for manufacturers and importers of equipment Specified Equipment Specified equipment category Residential air conditioners (excluding floor-standing type) Air conditioners for shops and offices (excluding floor-standing type)<<small size only>> Currently used refrigerant and its GWP R410A(2090) R32(675) Target index of environmental impact 11 Target year 750 2018 R410A(2090) 750 2020 Automotive air conditioners (only for passenger car) R134a(1430) 150 2023 Condensing units and Stationary refrigeration units (rated output > 1.5kW) Central refrigeration equipment ( only for new refrigeration warehouses more than 50 thousands m3 ) R404A(3920) R410A(2090) R407C(1774), CO2(1) R404A(3920) Ammonia 1500 2025 100 2019 Hard urethane foam HFC-245fa(1030), HFC-365mfc(795) 100 2020 Dust blower HFC-134a(1430), HFC-152a(124) CO2(1), DME(1) 10 2019 Manufacturers and importers shall ensure that the weighted average of GWP of domestic shipments does not exceed the target index to reduce environmental impact of the specified equipment.

2. Scope Expand Scope Reuse (1) HFCs Phase-down Low GWP HFCs Natural Refrigerant HFCs (5) Proper destruction and recycle Manufacturers of products containing HFCs Refrigerator Insulators Air conditioner Dust blowers (3) Reduction of refrigerant leakage from commercial equipment in use Periodical check (2) Promotion of low- GWP/non-fluorocarbons for designated products Products with alternatives Maintenance Users of products Report of leakage 12 Obligation of destruction Approved destructors/recycle Registered fillers/recovery operators (4) Proper refill and recovery

Revised regulation for equipment owners (users of products) Details of equipment check required for equipment owners Check points Frequency of check Operator of check 13 Simplified periodical check All Class-1 specified equipment (Air conditioners) Abnormal noise from air conditioner, apparent condition check and so on to judge leakage of HFCs (Refrigeration equipment) Temperature inside the cabinet Abnormal noise from equipment, apparent condition check and so on to judge leakage of HFCs More than once a 3 months (voluntary) No limitation on the qualification Periodical check Visual check by an operator having professional knowledge In the case that rough location of leakage can be found Other cases The check shall be conducted with direct method. The check shall be conducted with indirect method or combination of direct and indirect method. More than once a period determined for each equipment Authorised certification related to equipment management is needed.

2. Scope Expand Scope Reuse (1) HFCs Phase-down Low GWP HFCs Natural Refrigerant HFCs (5) Proper destruction and recycle Manufacturers of products containing HFCs Refrigerator Insulators Air conditioner Dust blowers (3) Reduction of refrigerant leakage from commercial equipment in use Periodical check (2) Promotion of low- GWP/non-fluorocarbons for designated products Products with alternatives Maintenance Users of products Report of leakage 14 Obligation of destruction Approved destructors/recycle Registered fillers/recovery operators (4) Proper refill and recovery

15 Expected reduction by new actions (Mt-CO2) [Estimation on BAU base] Actual shipment of HFC Reduction of new products Reduction of service usage Reduction of service usage Service usage New products Shipment of HFC Prospect of usage 40% down 52% down Prospect of usage In 2020. Prospect of usage In 2025.

Requirements for the alternative refrigerants 3E+S Safety(precondition) Environment Performance Energy Efficient Economic Feasibility Low Toxicity Low Risk of Flammability Ozone Depletion Potential =0 Low Global Warming Potential Superior for LCCP value Similar performance at high load cooling Reasonable Cost Acceptable level in Developing Countries LCCP(Life Cycle Climate Performance) CO2 Emission origin from energy in product usage Refrigerant Leaks in product usage CO2 Emission at refrigerant destruction CO2 Emission at refrigerant production Refrigerant Leaks at product disposal

Refrigerants for the next generation HVAC&R industry has been proceeding with the development of next generation low GWP refrigerants to mitigate the impact of HFCs on global warming. However ; Ideal refrigerants have not been found yet. Every candidate of next generation refrigerants bears some sort of faults. Usable candidates, in particular, are mildly flammable. We are forced to make full use of those candidates for prevention of global warming caused by refrigerants.

15 Thank you for your kind attention.