HBPS PRESSURE SENSOR For analogue pressure measurement of refrigerants

Similar documents
HBTS Temperature Sensor For temperature measurement in refrigeration systems

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

Configuration Manual. HBLT-Wire LEVEL SENSOR For analogue level measurements of NH3 & HFC in refrigeration systems

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Zero Superheat Control

PA ma Loop Powered Level Preamplifier

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

LC3000 Level Controller Installation and Maintenance Instructions

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Power Supply Display Module PSDM. Installation and Operation Manual

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Snifter ATEX22 VERSION. User Manual. Distributor

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

RFM Series RFM-ISR Barrier. Installation Manual

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

LC2200 Level Controller Installation and Maintenance Instructions

Gas cylinder scale Model GCS-1

for relative humidity and temperature with calibration certificates

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

IGD.CO.UK

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

7NG , 7NG

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Optimization of key processes in a refrigeration system. For maximum cooling load there was an EER increase of 18,6% (EER = Energy efficiency Ratio).

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AS 500. Instructions for Use. Version 1.0. December

FDCL221 Line separator

WIO200 Water in oil sensor

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

AND INSTALLATION MANUAL

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

WIO200 Water In Oil measuring instrument

VAMP 121. Arc protection unit. User manual

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Vacuum Controller with Control Unit VC 900

LC1350 Level Controller

Interface Modules for SENTRI

Multi Box HP 10. Accessories, split air to water heat pump PRINT APPROVAL 1 NOVEMBER Installation instructions (2012/11)

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

User manual CTX 300 CO 2

G4 Pulsed Fiber Laser

Snifter. User Manual. Distributor

Operating Manual MS220KA and MSR220KA

user manual Non-invasive Ultrasonic Flow Monitor KATflow 10 M E

5000 Series Rack Panels

APPLICATION DATA SHEET

SECTION Fluorescent Dissolved Oxygen Measuring System

Datasheet: K-22 LO Sensor

Operating Manual MS220DA

Operating Instructions

Important Safety Notice

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

Intelligent Security & Fire Ltd

Dry Bath Heating Systems

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

PROFIBUS-PA Display RID 261 PROFIBUS-PA

COOLARC 46 OPERATOR S MANUAL IM /2016 REV03 ENGLISH

Panel Mounted Fault Annunciator Series

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Old documentation - Only for your information! Product is not available anymore!

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

OPERATION MANUAL Model 8011 & mA

Heat Sensor Cable Alarm Units DT650L / DT950L

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

KM300 Carbon Monoxide Detection System Installation Manual

SITESTAR CABINET DESCRIPTION

Fill Point, Level Gauges, and Control Range

Original operating instructions Safety switch with guard locking AC901S AC902S

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Code 542 Peltier Rack User's Guide

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Laser Distance Sensor Type M Analog-Output

C 46 K a d. Specifications EKMC K. Ver.1.1. Page: EKMC K. 1.Product Name. 2.Model Number. 3.Dimensions. Approved by.

GMH 285 / GMH 285-BNC

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Intrinsically Safe Transmitters, Option Code 2n

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

UV Flame Supervision System

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Flameproof Manual Call Points

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Transcription:

Instruction Manual HBPS PRESSURE SENSOR For analogue pressure measurement of refrigerants Instruktionsmanual HBPS Pressure Sensor (001-UK) 1 / 6

Table of Contents Safety Instructions... 3 Introduction... 4 Briefly About Pressure Sensors... 4 Design and Function... 4 Technical Data... 4 Application Examples... 5 Installation Guidelines... 5 Power Connection... 5 Sensor Repair... 6 Further Information... 6 Instruktionsmanual HBPS Pressure Sensor (001-UK) 2 / 6

Safety Instructions CAUTION! Always read the instruction manual before commencing work! Heed all warnings to the letter! Installation of the sensory requires technical knowledge of both refrigeration and electronics. Only qualified personnel should work with the product. The technician must be aware of the consequences of an improperly installed sensor and must be committed to adhering to the applicable local legislation. If changes are made to type-approved equipment, this type approval becomes void. The product's input and output, as well as its accessories, may only be connected as shown in this guide. HB Products assumes no responsibility for damages resulting from not adhering to the above. Explanation of the symbol for safety instructions. In this guide, the symbol below is used to point out important safety instructions for the user. It will always be found in places in the chapters where the information is relevant. The safety instructions and the warnings in particular, must always be read and adhered to. CAUTION! Refers to a possible limitation of functionality or risk in usage. NOTE! Contains important information about the product and provides further tips. The person responsible for operation must commit to adhering to all the legislative requirements, preventing accidents, and doing everything so as to avoid damage to people and materials. Intended use, terms of use. The pressure sensor is designed for continuous measurement of liquid pressure on the refrigeration system. If the sensor is to be used in a different way and if the operation of the product in this function is determined to be problematic, prior approval must be obtained from HB Products. Prevention of collateral damage Make sure that qualified personnel assess any faults and take necessary precautions before attempting to make replacements or repairs, so as to avoid collateral damage. Disposal instructions: The sensor is constructed so that the modules can easily be removed and sorted for disposal. Instruktionsmanual HBPS Pressure Sensor (001-UK) 3 / 6

Introduction HBPS is an intelligent sensor with an in-built microprocessor. It is designed for continuous pressure measurement of liquid refrigerants in refrigeration systems. The sensor s measurement area depends on the type. With two variants, they cover 1 25 bar (LP) and 1 200 bar (HP). The sensor emits a 4-20 ma analogue signal which is proportional with the pressure level. Briefly About Pressure Sensors A pressure sensor measures pressure, typically of gases or liquids. The pressure is an expression of the force necessary to stop a liquid from expanding, and it is normally stated in force per unit of area. A pressure transmitter normally works as a transducer, which generates a signal as a function of the applied pressure. Design and Function The sensor consists of an assembled device. It is designed with waterproof rating IP67 and to resist vibrations. It is produced in AISI304 and tested to withstand high pressure. The sensor is designed for measurement of refrigerant pressure in industrial and commercial refrigeration systems. Technical Data Supply: Voltage: 24 V AC/DC ±10%* Connector: M12, 5 pins DIN 0627 Output: Analogue output: 4-20 ma Installation conditions: Ambient temperature: -30 50 C Refrigerant temperature: -40 +125 C Max. operational pressure: 25/200 bar Waterproof rating: IP67 Vibrations: IEC 68-2-6 (4g) Certifications: EMC Emission: EN61000-3-2 EMC Immunity: EN61000-4-2 Mechanical specifications: Thread connection: 1/4 G Materials mechanical parts: AISI304 Instruktionsmanual HBPS Pressure Sensor (001-UK) 4 / 6

Application Examples The sensor is designed for refrigerant pressure measurement in industrial refrigeration systems: Installation Guidelines The following applies to system design: 1) Can be installed both horizontally and vertically 2) The sensor must be installed and supplied with a standard non-shielded cable. If the EMC is higher than described in EN 61326, a shielded cable must be used. CAUTION! In case of welding on the system, make sure that a correct offset nulling has been performed, so that the electronics are not damaged during welding. Power Connection The sensor is loop powered with 24 V at terminal 1 & 3. Analogue output signal is as well in the loop. Instruktionsmanual HBPS Pressure Sensor (001-UK) 5 / 6

Sensor Repair The sensor electronics are completely encased and can therefore not be repaired. Complaints are processed by HB Products dealers/distributors. Please consider their complaint procedures before returning the sensor. Further Information For further information, please visit our website, www.hbproducts.dk, or send an email to: support@hbproducts.dk. HB Products A/S Bøgekildevej 21 DK8361 Hasselager support@hbproducts.dk www.hbproducts.dk Instruktionsmanual HBPS Pressure Sensor (001-UK) 6 / 6