INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Similar documents
INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

INSTALLATION MANUAL. Domestic hot water tank with UK kit for air to water heat pump system EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA

INSTALLATION AND OPERATION MANUAL

TABLE OF CONTENTS EKHWS

WH-TD20B3E5 WH-TD30B3E5

Powerflow Unvented water heater

Sanitary Water Tank INSTALLATION & SVC MANUAL

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

EEDEN technical data EKSOLHWAV1

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented Electric Water Heater 10/15 litre Undersink

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

AQUARIUS 45 MARINE SERVICE MANUAL

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Inverter Air Source Heat Pump Monobloc system

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

General safety precautions English

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

INSTRUCTION MANUAL KETTLE

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

TECHNICAL DATA & SERVICE MANUAL

L A signature series TA T N E RE O, A L L A T S IN

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

General safety precautions English

INSTRUCTION MANUAL (English version) Water still

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Mira Sport Max with Airboost

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Installation and operating instructions. DK energy storage and DK energy buffer

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

GLASS LINED STEEL ELECTRIC WATER HEATERS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

General Outline: Altherma

TABLE OF CONTENTS EDLQ AA6V3

EEDEN technical data. Altherma TM

GEOTHERMAL STORAGE TANKS

Multi-Elec COMPACTE BOILER

SELF-PRIMING JET PUMPS

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

User manual DEAN-10-C

Installation Manual CARBONATOR With Plain-Water Booster

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

12 kw Electric Tankless Water Heater Troubleshooting Guide

DOMESTIC STEAM GENERATOR Installation Instructions

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Electrical Mini Tank Water Heater anual, and Warranty nformation

TABLE OF CONTENTS EBLQ01-016AA6V3

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

ELECTRIC WATER HEATER HT382E55

RC411 Operator Manual

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

OPERATION MANUAL. Unit and options for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

Tempest TP420/180 Electric Pressure Washer

REFRIGERAT A OR USE DF1-15 F ridge

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

SUN EQUINOX HEATING SYSTEMS

Recirculating Cooler SRC14

Installation Manual. Instrucciones de instalación y manual de usuario 1

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Moisture inside the drum is due to final testing.

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

General safety precautions English

General safety precautions English

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

GeyserWise MAX. Thermostat instruction manual. SANS 181 compliant. All in one hot water management

Sauna & Steam. STEAM GENERATOR (Domestic & Light Commercial) Assembly and operating manual PRODUCT IMAGE

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

Snifter ATEX22 VERSION. User Manual. Distributor

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

Installation and User Instructions HS10U, HS15U.

4L Instant Water Boiler Instructions for Use

INSTALLATION AND USER MANUAL

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Transcription:

INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AV EKHWE00AZ EKHWE00AZ

4 5 6 7 x x x 4x x x x EKHWE50~00 EKHWET50 50 50 0 0 00 50 700 D 45 4 44 44 H H4 H 00 H5 00 700 0 0 440 45 55 775 50 400 705 5 500 A 400 A H 0 80 A 5 H H H H4 H5 Ø D 5 0~40 EKHWE 50 00 50 775 80 55 5 545 55 95 80 40 5 545 00 55 85 0 40 7 660 A 6 55 440 9 9 8 0 7 65

EKHWE50AV EKHWE00AV EKHWE00AV EKHWET50AV EKHWE00AZ EKHWE00AZ Domestic hot water tank for air to water heat pump system CONTENTS Page Introduction... General information... Scope of this manual... Model identification... Accessories... Accessories supplied with the domestic hot water tank... Warranty... Installation of the EKHWE domestic hot water tank... Main components... Outlook diagram... Installation guidelines... Installing the domestic hot water tank... Connecting the water circuits... Field wiring... 5 Commissioning...6 Maintenance...7 Troubleshooting...7 General guidelines... 7 General symptoms... 7 Technical specifications...7 Domestic hot water tank specifications... 7 Scope of this manual This installation manual describes the procedures for unpacking, installing and connecting the EKHWE domestic hot water tanks. Model identification EK HWE (T) 50 A V ACCESSORIES Booster heater voltage V = P, 0 V Z = P, 400 V (only for 00 l and 00 l models) Capacity booster heater: kw Series Indication of storage capacity in litres T = wall mounted; otherwise, floor standing Hot Water tank Enamel coated European Kit READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL. IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION. THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT TEMPERATURES RANGING 0 C~5 C. INTRODUCTION General information Thank you for purchasing this domestic hot water tank. The EKHWE domestic hot water tank with integrated kw electrical booster heater must be connected to the indoor unit. The domestic hot water tank is available in three sizes: 50, 00 and 00 litre. All models are floor mounted, while the 50 litre model EKHWET50AV is wall mounted. The 00 and 00 litre models are also available as 400 V versions. Accessories supplied with the domestic hot water tank See figure Thermistor + connection wire ( m) Contactor - fuse assembly Contactor fixing screw 4 Tapping screw 5 6 -way valve (Rp ") 7 -way valve motor WARRANTY Warranty will not be valid if a pressure relief valve of max. 0 bar is not installed. abnormal corrosion occurred due to not installing dielectric couplings. incorrect electric connections are made. applying electric power to the unit before filling it with water. insufficient maintenance, in particular not inspecting the anode every years and replacing if required. EKHWE50~00AV + EKHWE00+00AZ 4PW496-B

INSTALLATION OF THE EKHWE DOMESTIC HOT WATER TANK Main components The total AD system (indoor unit and outdoor unit) is designed for combination with an AD domestic hot water tank. In case another tank is being used in combination with the AD indoor unit, Daikin cannot guarantee neither good operation nor reliability of the system. For those reasons Daikin cannot give warranty of the system in such case. Domestic hot water quality must be according to EN directive 98/8 EC. A drain device should be installed on the cold water connection on the domestic hot water tank. For safety reasons, it is not allowed to add ethylene glycol to the water circuit. Adding ethylene glycol might lead to contamination of the domestic water if a leakage would occur in the heat exchanger coil. It is important that the storage capacity of the domestic hot water tank meets normal daily fluctuations in consumption of domestic hot water without any fall of the water outlet temperature during use. Take care that in the event of a leak, water cannot cause any damage to the installation space and surroundings. The anode shall be inspected at least every years and, if required, replaced. A pressure relief device of max. 0 bar should be installed on the domestic hot water tank. In case of limited consumption of domestic hot water, e.g. at holiday residences or at houses that are occasionally not occupied, the domestic hot water tank installation must be fitted with a shunt pump. The shunt pump can be time-controlled, the shunt pump must operate to circulate the complete volume of the domestic hot water tank.5 times per hour, and the shunt pump must operate, or be programmed for operation, during uninterrupted hours per day at least. 4 Cold water connection Hot water connection Shunt pump (field supply) 4 Non-return valve (field supply) In case of very long field water piping between the domestic hot water tank and the hot water end point (shower, bath, etc.) it can take more time before the hot water from the domestic hot water tank reaches the hot water end point. 4 A 5 6 7 8 9 0 Anode Hot water connection (/4" MBSP) (a) Pressure relief valve connection (/" MBSP) (a) 4 Electrical box 5 Recirculation hole (/4" MBSP) (a) 6 Thermistor socket 7 Heat exchanger inlet (/4" FBSP) (b) 8 Heat exchanger coil 9 Heat exchanger outlet (/4" FBSP) (b) 0 Cold water connection (/4" MBSP) (a) Thermistor hole for use with solar kit option. Refer to the EKSOLHWAV. Electric heater element Inspection flange 4 Thermal cut out 5 Cable entry from indoor unit 6 Cable entry for use with optional solar kit (a) MBSP = Male British Standard Pipe (b) FBSP = Female British Standard Pipe 4 4 5 6 A Shower Recirculation pump If required connect a recirculation pump in between the hot water end point and the recirculation hole in the domestic hot water tank. EKHWE50~00AV + EKHWE00+00AZ 4PW496-B

Safety devices The domestic hot water tank relief valve connections may not be used for other purpose. Do not install heaters without thermal cut-outs. Thermal protector The booster heater in the domestic hot water tank is equipped with a thermal protector. The thermal protector is activated when the temperature becomes too high. When activated, the protector has to be reset on the domestic hot water tank by pressing the red button (for access, remove the electrical box cover). The electrical box lid must only be opened by a licensed electrician. Switch off the power supply before opening the electrical box lid. Pressure relief valve A pressure relief valve (field supply) in accordance with relevant local and national regulations, and with an opening pressure of maximum 0 bar must be connected to the pressure relief valve connection. Water may drip from the discharge of the pressure relief valve device. Connecting the water circuits Refer to the chapter "Typical application examples" described in the installation manual delivered with the indoor unit for details on connecting the water circuits and the motorised -way valve. Make sure to insulate all water pipes and connections. Connecting the -way valve Refer to figure before making the connection. Installation position. It is advised to connect the -way valve as close as possible to the indoor unit. It can be installed according the following four configurations. Outlook diagram Outlook diagram, see figure. figure A figure B Installation guidelines Keep in mind the following guidelines when installing the domestic hot water tank: The installation location is frost-free. Take care that in the event of a leak, water cannot cause any damage to the installation space and surroundings. Make sure to make the piping in size " or more (and reduce to /4" at the inlet of the tank) as to have sufficient water volume in the piping between indoor unit and domestic hot water tank. Locate the domestic hot water tank in a suitable position to facilitate ease of maintenance; remember access is required to the electrical box. Refer to the grey-coloured zones indicated in figure. Provide a connection for the pressure relief valve blow-off and drain. To avoid back siphonage it is advised to install a non-return valve on the water inlet of the domestic hot water tank in accordance with local and national regulations. figure C From AD indoor unit To domestic hot water tank To room heating figure D Installing the domestic hot water tank Check if all domestic hot water tank accessories (see "Accessories" on page ) are enclosed. When floor mounting, place the domestic hot water tank on a level surface. If required, adjust the legs at the bottom. When wall mounting (only for EKHWET50AV model), make sure the wall is sturdy. In both cases, make sure the domestic hot water tank is mounted level. Make sure to respect the service space as indicated in figure. EKHWE50~00AV + EKHWE00+00AZ 4PW496-B

Unpack the -way valve body and -way valve motor. Verify that following accessories are provided with the motor. 6 Fit screw (see step ) in the lower right hand corner of the valve cover plate. 5 4 7 6 figure A and figure B Sleeve Screw Central screw 4 Red/blue scale 5 Cover 6 Indication plate 7 Valve motor cover figure C and figure D 7 Push the motor on the motor sleeve. Make sure not to rotate the sleeve during this action, as to maintain the valve position as set during step 4. 8 Put the red/blue scale on the valve as shown below. 4 Install the -way valve body in the pipework. Make sure the shaft will be positioned in such a way that the motor can be mounted and replaced. When installing the valve according to figure C or figure D, remove the indication plate and turn it upside down, making sure the scale "0 to 0" is located on the lower left bottom of the valve. Put the sleeve on the valve and turn the valve to the middle position (marked as "5") of the scale plate. Check that the valve is positioned as in the figure below. It should be blocking the outlet connection to the domestic hot water for 50% and the outlet connection to the room heating also for 50%. figure A and figure D figure B and figure C The red arrow will point to the red zone when the valve is in domestic water heating mode and will point to the blue zone when the valve is in room heating mode. 9 Make the wiring in the indoor unit according to following figure: 8 9 0 -way valve BLK BLU BRN figure A and figure B figure C and figure D If the valve is not positioned in this way before mounting the motor, the valve will give way to both domestic water and room heating during operation. 5 When installing according to figure B or figure C, open the valve motor cover by loosening the 4 screws and change the jumper as to change the rotation direction of the valve. By default the jumper is factory set to apply for installation according to figure A and figure D. figure A and figure D figure B and figure C Refer also to the drawing on page 6. Connecting the water circuits Connect the water inlet and water outlet from the heat exchanger. Connect the hot and cold water supply tubes. Make sure to use galvanic couplings for the connection. Connect the pressure relief valve (field supply, opening pressure maximum 0 bar). If a discharge pipe is connected to the pressure relief device it must be installed in a continuously downward direction and in a frost-free environment. It must be left open to the atmosphere. 4 EKHWE50~00AV + EKHWE00+00AZ 4PW496-B

Field wiring A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local and national legislation. All field wiring and components must be installed by a licensed electrician and must comply with relevant European and national regulations. The field wiring must be carried out in accordance with the wiring diagram supplied with the unit and the instructions given below. The domestic hot water tank must be earthed via the indoor unit. Procedure Switch off the power supply before making any connections. Connections to be made in the domestic hot water tank electrical box Make sure the power supply cable is insulated from the surface of the inspection hole or can resist temperatures to 90 C. For the EKHWE*V model, connect the booster heater power supply and thermal protection cable as shown in the wiring diagram below. Power circuit and cable requirements Be sure to use a dedicated power circuit. Never use a power circuit shared by another appliance. Use one and same dedicated power supply for the outdoor unit, indoor unit, backup heater and domestic hot water tank. For cable requirements and specifications, refer to "Field wiring" in the indoor unit installation manual supplied with the EKHBH/X unit. X0M 9 0 P P 4 X9M NOTE Select the power cable in accordance with relevant local and national regulations. Thermistor and thermistor cable Insert the thermistor as deep as possible in the thermistor socket. Fix using the spring provided. The distance between the thermistor cable and power supply cable must always be at least 5 cm to prevent electromagnetic interference on the thermistor cable. 4 XM EKHB 9 0 9 0 P EKSOLHW YLW/GRN BLU BRN X4M EKHB YLW Yellow BRN Brown GRN Green BLU Blue Can become hot 4 4 XM EKHWE50~00AV + EKHWE00+00AZ 4PW496-B 5

For the Z models, connect as follows: Note: only relevant field wiring is shown. X0M 9 0 P P 4 X9M TR KM KM K5M TR KM KM K5M X9A AP KM XA K7M M YLW/GRN BLU BRN AP K4M FB FB XM EKHB 4 9 0 P 9 0 X4M 4 XM EKSOLHW EKHB YLW Yellow BRN Brown A4P K6M XM GRN Green BLU Blue Can become hot X4M X4M 4 4a 5 6 7 8 9 0 4 5 5a 6 7 8 9 0 QL thermostat -way valve -way valve thermal SOLAR PUMP fuse OPTIONAL XM Make sure to ensure strain relief of the cable. Connections to be made in the indoor unit switch box Mount the prewired contactor (KM), circuit breaker (FB) and terminal blocks (XM, X4M). The contactor must be fixed with the supplied contactor screws and the terminal blocks must be fixed with the x supplied tapping screws. 4 Plug the connector connected to the contactor KM in the socket XA on the PCB. >50 mm XM L L L N XM (0V) L L L N XM 5 Plug the thermistor cable connector in the socket X9A on the PCB. 6 Connect the prewired earth wires of the terminal block XM and X4M to the earthing screw. 7 Connect the booster heater power supply and thermal protection cable (field supply) to terminal X4M earth,,, and XM, 4. 8 Connect the booster heater power supply cable to the terminal block XM. 9 Fix the cables to the cable tie mountings with cable ties to ensure strain relief. 0 Set DIP switch SS- on the PCB to ON. When routing out cables, make sure that these do not obstruct mounting of the indoor unit cover. V L N 0 V AC kw Z L L 400 V AC kw COMMISSIONING X4M 4 XM Before putting power to the unit, make sure: the unit is filled with water, the sensor of the thermistor cable is mounted correctly in the thermistor socket, a pressure relief valve is installed. Check the operation of the -way valve: make sure that when the indoor unit is in domestic water mode it sends hot water to the tank; when it is in room heating mode, it sends water to the room (feel the tubes by hand). BLK BLU BRN way valve 6 EKHWE50~00AV + EKHWE00+00AZ 4PW496-B

MAINTENANCE In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals. Before carrying out any maintenance or repair activity, always switch off the circuit breaker on the supply panel, remove the fuses or open the protection devices of the unit. Make sure that before starting any maintenance or repair activity, also the power supply to the outdoor unit is switched off. The pressure relief device valve is to be operated regularly as to remove lime deposits and to verify that it is not blocked. Once a year: Descaling Depending on the water and set temperature, scale will deposit on the heat exchanger and booster heater inside the domestic hot water tank. This will restrict heat transfer and can cause burn out of the booster heater. For this reason, descale the booster heater and the heat exchanger. Do not use sharp metal tools or strong acid to remove the scaling. Only use commercially available cleaning and scale removal agents for copper and enamelled surfaces. After removing the scale, rinse the domestic hot water tank by water jet. Once every year: Anode. Check if the anode is not deteriorated. If the diameter of the anode has decreased with 0 mm or more, make sure to replace it (original diameter is mm). It is of the utmost importance that the anode is in good contact with the domestic hot water tank. For this reason, after replacing the anode or other servicing, make sure that the anode is connected with the earthing screw. TROUBLESHOOTING This section provides useful information for diagnosing and correcting certain troubles which may occur in the unit. General guidelines Before starting the troubleshooting procedure, carry out a thorough visual inspection of the unit and look for obvious defects such as loose connections or defective wiring. Before contacting your local dealer, read this chapter carefully, it will save you time and money. When carrying out an inspection on the supply panel or on the switch box of the unit, always make sure that the circuit breaker of the unit is switched off. When a safety device was activated, stop the unit and find out why the safety device was activated before resetting it. Under no circumstances safety devices may be bridged or changed to a value other than the factory setting. If the cause of the problem cannot be found, call your local dealer General symptoms Symptom : No water flow from hot taps POSSIBLE CAUSES The main water supply is off. Symptom : Water from hot taps is cold POSSIBLE CAUSES The thermal cut-out(s) has/have operated CORRECTIVE ACTION Check that all shut off valves of the water circuit are completely open. CORRECTIVE ACTION Check and reset button(s). Put the thermostat setting for domestic hot water on the indoor unit to 75 C. Check if thermistor is correctly installed in thermistor socket. The indoor unit (EKHBH/X) is not operating. Check the indoor unit (EKHBH/X) operation. Refer to the manual delivered with the indoor unit. If any faults are suspected, contact your local dealer. TECHNICAL SPECIFICATIONS Domestic hot water tank specifications EKHWE50AV EKHWET50AV EKHWE00AV EKHWE00AZ EKHWE00AV EKHWE00AZ Volume 50 l 50 l 00 l 00 l 00 l 00 l Internal heat exchanger volume l l l l l l Overall dimensions (Ø x H) 545 x 50 mm 545 x 50 mm 545 x 55 mm 545 x 55 mm 660 x 55 mm 660 x 55 mm Booster heater, power supply 0 V 50 Hz P 0 V 50 Hz P 0 V 50 Hz P 400 V 50 Hz P 0 V 50 Hz P 400 V 50 Hz P Booster heater, running current A A A 7.5 A A 7.5 A Booster heater, capacity kw kw kw kw kw kw Connections Refer to "Main components" on page Weight (empty) 80 kg 8 kg 04 kg 04 kg 40 kg 40 kg Mounting Floor Wall Floor Floor Floor Floor Maximum pressure 0 bar 0 bar 0 bar 0 bar 0 bar 0 bar Maximum domestic hot water temperature 75 C 75 C 75 C 75 C 75 C 75 C Maximum temperature through heat exchanger 0 C 0 C 0 C 0 C 0 C 0 C EKHWE50~00AV + EKHWE00+00AZ 4PW496-B 7

*4PW496- B 0000000S* Copyright Daikin 4PW496-B