L-Series, Indoor Strobes and Horn Strobes

Similar documents
L-Series, Indoor Strobes and Horn Strobes

L-Series, Emergency Communication Devices

Selectable Output Chimes and Chime/Strobes

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

SELECT-A-HORN/STROBE SERIES

TrueAlert Notification Appliances

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

ELECTRONIC SOUNDER STROBE Model : AVD-C407

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

The Advance You ve Been Looking For

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

s Notification Appliances

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

TrueAlert Multi-Candela Notification Appliances

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Agent Release Control Panel

Life safety notification

Potter Wall Mount Select-A-Strobe

TrueAlert Addressable Notification Appliances

Wheelock RSS & RSSP Series

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

E3 Series Broadband System

'08 Series Notification A liances

Field Configurable Horns and Strobes

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

Genesis LED G1 Series

TrueAlert ES Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert Multi-Candela Notification Appliances

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

SECTION FIRE ALARM SYSTEMS

Field Configurable Horns and Strobes

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls

System Sensor L-series indoor horn/ strobes

Speakers and Speaker Strobes

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Addressable Detectors & Bases

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Dimensions of the Optional Mounting Box (BB-400R/W)

LifeAlarm Fire Alarm Controls

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

ECC-50/100C. Emergency Command Center

July 14, 1999 DF C-100.

TrueAlert Addressable Notification Appliances

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

ECC-50/100(E) Emergency Command Center

TrueAlarm ES Analog Sensing

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

Conventional Fire Detection

LifeAlarm Fire Alarm Control Panels

Booster Power Supply Manual

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Specification/ Data Sheet

Addressable Fire Alarm Control Panel

June 10, 2002 DF C S2424

*15cd models are Listed at 15cd and meet 75cd on axis

good things in small packages

Signature Series Auto-Sync Output Module (CC1S)

TrueAlert Addressable Notification

1. POWERPATH Operation

SAFEPATH SAFEPATH. Emergency communications system

AL602ULADA AL802ULADA AL1002ULADA

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

B. The fire alarm system shall be manufactured by an ISO 9001 certified company and meet the requirements of BS EN9001: ANSI/ASQC

GEC Low-frequency Horn Strobes

Xenex Conventional Fire Detection & Alarm System

Remote Booster Power Supplies

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Autonomous control unit

NBG-12LR and NBG-12LRA

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

D7044. Installation Instructions Multiplex Single Input Module

Figure 1. Figure 2. See notes 1 and 2 below.

TrueAlert Addressable Notification Appliances

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117

SAFEPATH Mass Notification System (SPMNS)

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

INSTRUCTION & SERVICE MANUAL

Multiple Input and Output Modules

Conventional Audible Visual Range

AL800ULADA. NAC Power Extender. Installation Guide

D7052. Installation Instructions Multiplex Dual Input Module

Conventional Fire Alarm Systems

SP40S-D. Kingfisher Company, inc. Features: Description:

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

AP200 SERIES INTELLIGENT ALARM DEVICES

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Transcription:

Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer the most versatile and easy-touse product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and a modern aesthetic design which reduce installation times and maximize profits. In addition, the L-Series offers white and red plastic housings and wall and ceiling mounting options. Similar to the entire L-Series product line, the ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These features make installations fast and foolproof while eliminating costly and time-consuming ground faults. To simplify the installation, the L-Series uses a universal mounting plate allowing you to mount the devices to a wide array of backboxes. With an on-board shorting spring, Installers can test wiring continuity before the device is installed. Ceiling Horn Strobe Installers can also easily adapt devices to suit a wide range of application requirements using the following: Field-selectable candela settings Automatic selection of 12- or 24-volt operation Rotary switch for horn tones with two volume selections FEATURES & BENEFITS Listed for ceiling mounting only Features a plug-in design so that there is minimal intrusion into the backbox Designed with a tamper-resistant construction Provides an automatic selection of 12- or 24- volt operation at 15 and 30 candela Uses field-selectable candela settings on the following ceiling units: - 15-30 - 75-95 - 115-150 - 177 Produces horn rated at 88+ dba at 16 volts Offers a rotary switch for horn tone and two volume selections Includes a universal mounting plate for ceiling units Contains a mounting plate with a shorting spring feature that checks the wiring continuity before device installation Compatible with MDL3 sync module Supports electrical compatibility with the legacy SpectrAlert and the SpectrAlert Advance devices

Architect/Engineer Specifications General The L-Series ceiling-mount strobes and horn strobes shall mount to any of the following: double-gang backbox 4-inch octagon backbox a standard 4 x 4 x 1 1/2-inch backbox Two-wire products shall also mount to a single-gang compact 2 x 4 x 17/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When it is used with the Sync Circuit Module, the following occur: 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have the following fieldselectable candela settings including: 15 30 75 95 115 150 177 Strobe The strobe shall be an L-Series Model listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. Horn Strobe Combination The horn strobe shall be an L-Series Model listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate o a coded or non-coded power supply. Synchronization Module The module shall be a Sync Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize the L-Series strobes at 1 Hz and synchronize horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single-pair of wires. The module shall mount to a 4 11/6 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UL Current Draw Table 1 lists the UL maximum strobe current draw. 8-17.5 Volts 16-33 Volts Candela FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Table 1: UL Maximum Strobe Current Draw (ma RMS) 2

UL Current Draw Data Table 2 lists the maximum UL Current Draw (ma RMS) allowed for 2-Wire Horn Strobes. 8-17.5 Volts 16-33 Volts Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.1K Temp Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 256 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Table 2 UL Max. Current Draw (ma RMS), 2-Wire Horn Strobe Horn Strobe Tones and Sound Output Data Table 3 lists the horn strobe tones and sound output date. 8 17.5 Volts 16 33 Volts Switch Position Sound Pattern db FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 Table 3: Horn Strobe Tones and Sound Output Data 3

L-Series Dimensions Figure 1 illustrates the dimensions for the ceiling-mount horn strobes. L- Series Dimensions Figure 3 illustrates the dimensions for the ceiling backbox 2.47" (62.7 mm) 6.83" diameter (173 mm) 1.37" (34.8 mm) Figure 1 Ceiling-Mount Horn Strobes L-Series Dimensions Figure 2 illustrates the dimensions for the ceiling backbox Figure 3 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox SL Series Dimensions Figure 4 illustrates the dimensions for the ceiling backbox 6.92" diameter (175.77 mm) 2.50" (64 mm) Figure 2 Ceiling-Surface-Mount Backbox L-Series Ordering Information Ceiling Horn Strobes: PC2RL: 2-Wire, Horn Strobe, Red PC2WL: 2-Wire, Horn Strobe, White PC4RL: 4-Wire Ceiling Horn Strobe, Red, FIRE PC4WL: 4Wire Ceiling Horn Strobe, White, FIRE Ceiling Strobes: SCRL: Strobe, Red SCWL: Strobe, White SCWL-CLR-ALERT: Strobe, White, ALERT Figure 4 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Backbox L-Series Ordering Information Accessories: TRC-2: Universal Ceiling Trim Ring Red TRC-2W: Universal Ceiling Trim Ring White SBBCRL: Ceiling Surface Mount Back Box, Red SBBCWL: Ceiling Surface Mount Back Box, White 4

L-Series, Indoor Strobes and Horn Strobes Technical Specifications SYSTEMS Temperature Ranges: Standard Operating Temperature: 32 F to 120 F (0 C to 49 C) Humidity Range: 10 to 93% non-condensing Voltages: Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12 V or regulated 24 /FWR 1 Operating Voltage Range 2 : 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3): 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V(24V nominal) Wire Gage: Input Terminal Wire Gauge: 12 to 18 AWG Dimensions: Ceiling-Mount Dimensions (including lens): 6.8" diameter 2.5" high (173 mm diameter 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a nonregulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 49 C/32 120 F and at a relative humidity 93% ± 2% RH (noncondensing) at 32 C ± 2 C (90 F ± 3 F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 27 C/60 80 F. STANDARDS The L-Series, Ceiling Strobes and Horn Strobes are designed to comply with the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S5512, S4011 CSFM: 7135-1653:0503 7125-1653:0504 ISO 9001 Certification For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewellfci.com/en-us/ documentation/pages/ Listings.aspx E3 Series and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL is a registered trademark of Underwriter s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-todate and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information Learn more about Gamewell-FCI s L-Series, Indoor Strobes and Horn Strobes and other products available by visiting www.gamewell-fci.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com 9021-60928 C 03/18 2018 Honeywell International Inc.