Wire Harness Assembly Part #PP-1037 For Models HR01 (2011 to present)

Similar documents
AMERICAN ENERGY SYSTEMS INC. INSTALLATION, OPERATION AND MAINTENANCE MANUAL

COUNTRY FLAME TECHNOLOGIES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PELLET STOVE SERVICE MANUAL

AGP. (All Grade Pellet) Troubleshooting Guide Document Copyright 2017 Travis Industries Certified Factory Training Program

AMERICAN ENERGY SYSTEMS INC. INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Pellet Stove Test Manual

OPERATING & MAINTENANCE MANUAL

Corn Flame Energy Corn Stove Model 3000

Magnum Baby Countryside Corn/ Biomass / Wood Pellet Stove

Pellet Appliance Troubleshooting Guide

Corn / Pellet Stove Model: #OLV-PC

AMERICAN ENERGY SYSTEMS, INC.

Operating & Maintenance Manual

8 INSTALLATION. C. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 10) NOTE: Follow L-Vent chimney manufacturer s instructions.

New Power Vented Rheem FVIR Tanks

Electronic Pellet Burner Controller NPBC-V3M

Dear Customer, We at Northwest Mfg., Inc. would like to thank you for purchasing the

OWNER S MANUAL MX2 TM CONTROL EQUIPPED WOOD PELLET BURNING HEATER * INSTALLATION * OPERATION * SERVICE * PARTS *

Pellet Stove Test Manual

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

Electronic Pellet Burner Controller NPBC-V3-1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER.

INSTALLATION & OPERATION MANUAL

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Operation & Maintenance Manual

THE GREEN ALTERNATIVE IN HOME HEATING

MERIDIAN Freestanding and Fireplace Insert

INSTALLATION & OPERATION MANUAL. Biomass Furnace/Stove Rev L, Patents Pending

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

EF3 Freestanding, Fireplace Insert, and Built-In Heater

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

Pellet Stove Test Manual

EF3 Freestanding, Fireplace Insert, and Built-In Heater

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

Technical

Monitoring Software for NPBC-V3M-1 User Manual

MERIDIAN Freestanding and Fireplace Insert

SAVE THESE INSTRUCTIONS

PELLET STOVE OPERATING & INSTALLATION INSTRUCTIONS

AGP Pellet Insert. -- Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Technical

Foxfire Pellet Stove. -- Contact local building or fire officials about restrictions and installation inspection requirements in your area.

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

AGP PELLET STOVE & INSERT

PELLET HEATER TROUBLESHOOTING GUIDE

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /7/10

Installation & Operations Manual. Ashby Insert. Series

Corn-trol Digital - Model TS2C V3-83. Instruction Manual

1F90-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

Installation/Operator s Manual

PRYCO, INC. FUEL CONTROL

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

MODEL: VG5790 OWNER S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

1F90W-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat WHITE-RODGERS

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

COUNTRY FLAME TECHNOLOGIES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

UNITED STATES STOVE COMPANY Keeping North America Warm Since King Pellet Stove 5502M. Owner s Manual

AGP Pellet Stove. -- Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Magnum Baby Countryside Corn/ Biomass / Wood Pellet Stove Models BC-AC, BC-DC

Owner s Manual for the Cordless Backpack

Technical

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Description of the vacuum

Easy to live with...

MAXX OWNER S MANUAL F R E E S T A N D I N G P E L L E T S T O V E WARRANTY REGISTRATION enviro.com/warranty

Figure 10 or Figure 6

MERIDIAN-1 P E L L E T S T O V E

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

MAXX-M OWNER S MANUAL F R E E S T A N D I N G P E L L E T S T O V E WARRANTY REGISTRATION enviro.com/warranty

Before selecting your stove, it is very important that you clearly identify what your needs are:

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

W / E / W / E / $10.00

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

CSD-1 COMMERCIAL BOILER CONTROLS

1F91W-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! Multi-stage Electronic Digital Thermostat

XXV Pellet Stove Owners Manual

INSTRUCTIONS CONTROL PRODUCTS INITIAL SET-UP. Innovative Technologies in Custom Electronic Design & Manufacturing

Operator: Save these instructions for future use!

HEAT HEAT HEAT COOL COOL

AGP Pellet Stove. -- Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Owner s Manual MODEL 8555

Installation/Operator s Manual

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. TECHNICAL MANUAL


PROBLEM CAUSE SOLUTION

EF3003 SF3003 DF3003

LUXURY SERIES P2700 OWNER S MANUAL

Transcription:

Wire Harness Assembly Part #PP-1037 For Models HR01 (2011 to present) Unplug unit Open both side panels. Remove existing wire harness. May need to cut off existing molex and replace with male/female wire connectors. Attach the following: o Control Board molex connector and black lead to terminal Fuel stirrer lead terminal molex o Fuel Stirrer motor o Snap disc right side o Exhaust Fan o High Limit Snap Disk o Vacuum Pressure Switch o Proof of Fire Snap Disk o Auger Motor o Room Air Fan o Electrical Plug o NOT USED black wire from control panel to one black lead double white lead to black lead not used white wire to one lead blue wire to one lead two orange wires to both leads two grey wires to both leads top terminal and middle terminal two brown wires to both leads white wire to one lead yellow wire to one lead double white wires to one lead pink wire to one lead double white wires middle terminal black wire bottom terminal green wire to top terminal other end of green wire screwed to base of unit red wire & white wire Plug unit in Turn on unit

Below is a graphical display of the Country Flame NPS-1005-N Control Board front panel. Each operational function of the control board is shown for proper operation of the control center. Power- on light glows amber when on Auger feed light (amber when on) Heat level indictor LED (red per heat level setting) Heat level (up) adj. button Heat level (down) adj. button Manual or Thermostatic operation mode button Room fan adjustment button Auger trim Adjustment button Exhaust/Draft Blower trim adjustment button ON/OFF control button

OPERATING INSTRUCTIONS (Without using system igniter) NOTE: Each time the stove is started, the firepot should be checked for debris and clear air holes. Some fuels will cause the firepot to build up more frequently making it necessary to stir and clean the firepot more often. Do not allow ash to build up underneath the firepot. Your control panel has three (3) separate modes of operation (switch located on top of board). The MANUAL setting allows the operator to choose heat level setting changes without a thermostat. The T-STAT setting allows the operator to set the high heat level setting and when the thermostat is satisfied, the unit will automatically go to the low heat level setting. The AUTO setting allows the unit to shut completely off when the thermostat is satisfied and re-start when the thermostat calls for heat. The AUTO setting can only be used with wood pellets. Before lighting your Country Flame for the first time make sure that all items are out of the hopper and firebox area. Note: If using a wall thermostat, make sure that the thermostat is turned up above room temperature. The unit will operate on low fire if the thermostat is turned down. Load the hopper with fuel (Corn or Wood Pellets). Place a small handful of wood pellets or fire starter in the firepot. Squirt a small amount of fire starter gel on top of the wood pellets. (Evenly across the wood pellets) Light the fire starter gel. Close the door Push the On/Off button. Turn the air intake butterfly damper to approximately ¼ inch open. (More or less as needed.) NOTE: Priming the auger is required when the unit is new or when the hopper has completely run out of fuel. This can be done approximately 1 minute after pushing the on/off start button. Press and hold the auger button until fuel begins to drop into the firepot. When fuel begins to drop regularly, release auger button, the auger is primed. NOTE: The viewing door, ash pan door and hopper door must be closed and/or latched during operation or the vacuum will not be established. If vacuum can not be established the stove will shut down and the #2 heat level setting light will blink. The ON/OFF button must be pushed and held for app. 6 seconds to reset the system. The unit starts on a pre-set heat level setting. After the unit has been turned on you may select the desired heat level. However, the feed rate heat level will not change until the unit has completed the 15 minute startup sequence. It is recommended to burn the unit on the number #2 or #3 heat level setting for the first 30-45 minutes. If the fire temperature has not reached proper operating temperature within the minimum cycle time (15 min.) the auger will stop feeding, the stove will shut down and the #3 heat level setting light will blink. You will need to press and hold the ON/OFF button for 6 seconds to start the cycle over again. If the system is set on auto start it will attempt two startups on its own. The draft and room air blower speed varies directly with the feed rate. The Draft Trim button will override the variable fan function +/- 5 volts on all heat levels. To override, press and hold the Draft Trim button along with the heat level button arrow up or heat level button arrow down, depending on desired change.

The auger feed rate on each setting is pre-programmed but may be changed if necessary. The Auger Trim button will override the programmed feed rates by +/-5% on all heat levels. To override the feed rate press and hold the Auger Trim button along with the heat level button arrow up or heat level button arrow down, depending on desired change. NOTE: In case of a power outage or interruption lasting longer than 5 seconds, the On/Off button must be pushed to re-engage the auger. If needed re-light the unit. NOTE: If the fire is burning too fast and the fuel is being burned up too quickly, turn the air intake butterfly damper closed a little to slow the fire down. This should be done in small 1/4 increments so that the fire doesn t change too quickly. You may also adjust the draft and auger trim to balance the burn rate. NOTE: When changing the heat levels there will be a delay so the system can complete the cycle before switching to the new heat level. NOTE: In case of a power outage, the pressure switch has tripped, the door has been opened, the hopper door has been left open or any power interruption lasting longer than 5 seconds, the On/Off button must be pushed and held for app. 6 seconds (or until you here a click) to re-engage the auger system. IMPORTANT: The circuit board will not function properly if the outlet is not a constant 120 volt, 60 cycle power source. The outlet must be grounded properly and have the correct polarity. A polarity and ground tester can be picked up at any hardware store to assure proper operation. If you are using a power generator, solar power or wind generation make sure that you have a constant correct power source. The unit s electrical warranty would become void if a constant power source is not available. Also make sure that a proper surge protector is between the unit and the power source. The circuit board will not be warranted if there is not a surge protector installed to the unit. It is strongly recommended that you unplug the power source during times when the unit is not being operated to protect the unit from power surges, power spikes and drops in power. It is very common for a circuit board to work when the unit is shut off in the spring and then won t work in the fall. Unplugging the unit will prevent this from happening.

INTRODUCTION This section will explain the inputs/outputs, operation, and maintenance of new control board. Included are helpful hints and suggestions that will make the operation and maintenance of the board an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit from our units. Important Information: The information provided in this document applies to Program Revision 18 of NEW CONTROL board and may not be applicable to other revisions. THE CONTROL BOARD DESIGN The Figure 1 shows the design/layout of the control board for NEW CONTROL. FIGURE 1: THE DESIGN NEW CONTROL has following INPUT(s) to control the system functions. 1. ON/OFF Switch 2. AUTO/TSTAT/MANUAL Switch 3. AUGER TRIM/FEED Switch 4. HEAT CONTROL UP 5. HEAT CONTROL DOWN 6. DRAFT/FAN TRIM 7. HIGH FAN TRIM NEW CONTROL has following OUTPUT(s) to display the system functions. 1. POWER ON/OFF LED 2. PRIME ON/OFF LED 3. HEAT LEVEL INDICATION/ALARM LED

INPUT SWITCHES 1. ON/OFF When pressed in IDLE, ON/OFF switch turns ON the unit. When pressed in Ignition/Run, ON/OFF switch turns OFF the unit. 2. TSTAT/AUTO/MANUAL When in TSTAT/AUTO, the unit follows TSTAT input. In MANUAL mode, HEAT levels can be controlled by using HEAT UP/DOWN keys. 3. PRIME/FEED To prime press & hold, PRIME/FEED switch starts the auger if in RUN mode. This switch is only effective in Run/Ignition mode. During Run, Auger trim can be adjusted by pressing & holding PRIME/FEED switch and HEAT UP/DOWN switch. 4. HEAT UP/DOWN The heat levels can be controlled by using these switches. There are five (5) HEAT levels indicated by HEAT LEVEL INDICATION LEDs. 5. DRAFT TRIM The DRAFT FAN trim can be controlled using this switch and HEAT UP/DOWN. During Run, DRAFT trim can be adjusted by pressing & holding DRAFT trim switch and HEAT UP/DOWN switch. 6. HIGH FAN The HIGH FAN trim can be controlled using this switch. During Run, HIGH FAN trim can be adjusted to line voltage by pressing the HIGH Fan switch. 7. FUEL STIRRER To manually operate fuel stirrer prime press & hold, both HIGH FAN trim and HEAT UP switch. OUPUT LEDS 1. POWER ON/OFF LED This LED is ON if the unit is ON, else unit is OFF. 2. PRIME/FEED LED If YELLOW/PRIME/FEED LED is ON, the Auger is ON and Proof of Fire is closed. If YELLOW/PRIME/FEED LED is OFF, the auger is OFF. 3. HEAT LEVEL INDICATION LED Depending upon the HEAT LEVEL, respective HEAT LEVEL INDICATION LED will glow. For reference purpose, lowest level LED is LED1 and highest level LED is LED5. OPERATION Power Initialized: The exhaust fan will run approx. 12 minutes after power initialized or after a power failure. If POF open, unit enters initial cool down mode (approximate 9-min). If POF is closed, unit will begin a Warm Re-Start to IGN. 1.0 START ON/OFF 1.1 Ignition mode: Comb Fan 100 %, Auger @ IGN level, Igniter ON & after the 1st cycle (approximately 13 minutes), Igniter is OFF. Comb Fan remains @ 100% Auger cycle remains @ IGN level for balance of igniter period (15-min typical). (Additionally, Auger Setting & Room Fan may be preset for desired level during IGN period and this will be the operation value at end of igniter period)

1.2. RUN mode: Simultaneously @ end of 15-min Igniter period: a) Igniter & IGN auger sequence will terminate. b) At any time POF is closed, the Room FAN is active for cooling with 5-indpendent levels: 20%, 40%, 60%, 80%, 100% drive. c) Manual Auger is indicated with Yellow LED and displays on period of Auger motor. d) Heat Levels (combustion & Auger) are 5-levels with 20% incremental steps from 0% to 100%. 1.3. TSTAT operation in RUN: Auto/T-Stat mode can be enabled or disabled by pressing TSTAT switch. If Auto/TSTAT mode enabled, unit starts following TSTAT. Unit detects open T-Stat during RUN only and provides for Low feed combustion regardless of pre-set Heat level. If the TSTAT is open for 30 minutes (approximate), the unit turns off and goes to IDLE mode. If T-Stat is closed in TSTAT/Auto mode, unit will follow manual mode. 1.4 TSTAT operation in IDLE: Auto/T-Stat mode can be enabled or disabled by pressing TSTAT switch in IDLE. If in Auto/T-Stat mode, unit will start if TSTAT is closed. 2.0 CYCLE OFF SYSTEM OPERATION System can be Turned OFF by pressing On/Off switch. Fan(s) will operated 15-min typical or until POF is OPEN for safe cooling. 2.1. Alarms: a) If Vacuum pressure switch (APS) is OPEN during RUN for 30 seconds, AUG stops feeding and a #2 light will start blinking showing APS Error. Unit enters COOL Down. Things to check if vacuum issue prior to resetting the board check that access door is properly closed, ash pan door is locked and sealed, verify hose on vacuum switch hasn t came off, verify vacuum is not plugged. b) If low limit (POF) is not closed at end of IGN period or during RUN for 30 seconds and a #3 will start blinking showing POF error. Unit enters a COOL Down. Verify unit has been primed, verify fuel in hopper, check hopper to make sure fuel is not

c) If High Limit (OT) is OPEN during RUN for 30 seconds, AUG stops feeding and a #4 will start blinking showing OT Error. Unit enters COOL Down. 3.1 AUGER OFF FUNCTION DURING IGNITION SPECIAL FUNCTIONS If in Ignition, if High Fan switch is pressed, Auger turns off for two (2) minutes. SPECIAL NOTE A) For factory testing, igniter sequence may be bypassed by depressing HEAT UP and HEAT DOWN keys at the same time. Unit will go directly to RUN Mode. B) Programs can be changed only in IDLE mode, by pressing HEAT UP switch and then MODE/HIGH FAN switch. C) Auger does not start for two (2) minutes in Programs #1, #2, #9 and #10 (corn mode) but Auger runs for 3 minutes and then turn off for 2 minutes in Programs 3 through 8 (pellet mode). Programs can be changed only in IDLE mode if APS (vacuum) is OPEN, by pressing HEAT UP switch and then MODE/HIGH FAN switch. To change the program, the system should be in IDLE mode (not in Ignition or RUN mode) with APS (vacuum) fail. After this, by pressing Fuel (MODE SW) switch and Heat-Up switch, the program can be changed. The Red LEDs will blink x number of times depending upon the x number of program.