MEDICAL CHILLER SYSTEMS

Similar documents
OACS Outdoor Air-Cooled Central Chillers

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Nirvana. Cycling Refrigerated Dryers

NQ Series Portable Chillers

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Liebert CSU3000 Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

.2 Section Waste Management and Disposal.

Precise Temperature Control; Compact Footprint

Nirvana Cycling Refrigerated Dryers

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

30GT FLOTRONIC AIR-COOLED CHILLERS

Call us today! (800)

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

Call us today! (800)

Call us today! (800)

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

30GN FLOTRONIC II AIR-COOLED CHILLERS

Flexible & Innovative. Cooling Solutions

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

SECTION ROTARY-SCREW WATER CHILLERS

GP SERIES Packaged Chillers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

MAC-120HE-03 Air-Cooled Chiller

Air-Cooled Condensing Units with Compact Screw Compressors

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

TRIDENT GS SERIES Central Chiller

Cultivator & Hybrid Cultivator

MACH N-407 Heat Pump Air-Cooled Chiller

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Outstanding Performance; Application Flexibility

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

Refrigerated Compressed Air Dryers

The ultimate fresh air solution.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Chapter-8 Capacity Control of Refrigeration Systems

LQ AQ SQ. Air-cooled and water-cooled portable chillers

MAC N-407 Air-Cooled Chiller

SECTION AIR COOLED WATER CHILLERS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TCC-34. Features: TISSUE CULTURE

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Temptek Auxiliary Equipment

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Ultimate energy saving technology

SECTION WATER-SOURCE UNITARY HEAT PUMPS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Innovation for a Better & Greener Future

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

Refrigerated Compressed Air Dryers 5-6,000 scfm

VariCool VAV Engineering Guide

SPC-56 SHORT PLANT.

500 EX Fusion Compressor Series

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

RGE 13 A T - 1 A

Product Chillers A P P L I C AT I O N S

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

Ultimate energy saving technology

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

R- 410A Series Zero Ozone Depletion

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

PDF Created with deskpdf PDF Writer - Trial ::

WO P NF L M 407c Spec Submittal

WO P NF L M 407c Spec Submittal

Product Data. Features/Benefits ComfortLink control

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,

Guide Specifications

TCR. Features: TISSUE CULTURE

Transcription:

Mission Critical Chilled Water Systems Engineered to Exacting Standards Magnetic Resonance Imaging Systems CT Scanners Oncology Linear Accelerators Blood Cooling Systems Precise Laboratory Applications Lasers and Electron Microscopes MEDICAL CHILLER SYSTEMS

When precision counts, count on us. We were cool long before it was a trend. Since the early 80 s, ArctiChill has earned a valuable reputation for producing mission-critical, precision water cooled and air cooled refrigeration systems for medical applications. Models are pre-engineered to meet major medical equipment specifications such as General Electric, Siemens, Varian, Hitachi, and others. They have evolved into a suite of products and accessories that are guaranteed to meet the precision flow, pressure and delivery requirements for accurate, dependable critical cooling. With unmatched experience in both the refrigeration and site installation and start-up aspects of medical applications, we are uniquely qualified to provide a complete solution, matching OEM requirements and site, piping or am- bient variables to assure the right equipment and long term reliability that recognizes your patient loads and bottom line. Let us show you how easy complete customer satisfaction can be. Fully redundant chillers are available including refrigeration, microprocessors and electrical service components. Model shown is a small footprint redundant package chiller system including redundant air cooled condensers, controls and pumps. Dedicated redundant systems share a tank so that switchover occurs with no temperature loss. Unparalleled Commitment to Service When a diagnostic or treatment center is handling a high patient load, even small lapses of operations due to equipment failures is simply unacceptable and unnecessary. By employing the highest quality non-proprietary and widely available components, assembled and tested by highly skilled technicians, and bolstered by advanced microprocessor control systems, system redundancy, automated city-water switch over schemes and our new web-based diagnostic and alerting system, there is simply no need for second-best - no better choice than ArctiChill. We make component access, local part availability and serviceability a primary ingredient. And when you do need us on site, our in-house and trained field service staff stands ready. We can even handle initial site planning and startup. We also maintain a 24 hour service hotline. Components, controls and know-how are combined to provide high performance consistency critical for advanced imaging requirements.

When cool is critical, so is design. Never lose your cool. When critical process cooling equipment is deployed, downtime due to equipment failure, or poor delivery of process liquids within the temperature and pressures required can be disastrous. Even unplanned circumstances such as inconsistent power, improper maintenance, failure due to normal wear and tear, or improper usage can result in unnecessary downtime. To ensure that conditions remain within your parameters, ArctiChill has developed a number of methods to reduce downtime. Redundancy in refrigeration circuits Redundant controls with automatic operation Dual Pumping with automatic lead/lag pump Automatic City-Water Switch over Panels Remote Control Room Indicator Panels Modem or Wireless Remote Diagnostics Advanced email based Alerting System Automatic city water switch over panel includes optional heat exchanger to isolate process liquid/glycol from drain. NEW refrigeration-free system uses YOUR chilled water source. Imaging equipment requires close control of temperature variation, consistent flow and constant pressure, things a traditional plant chilled water system can rarely do consistently. ArctiChill has a solution that utilizes NO refrigeration. Combining a thermal mass tank of water, a cleanable heat exchanger and accurate thermostatic mixing methods and controls, the system provides highly accurate chilled water cooling to meet OEM specifications. It rejects the heat from sensitive equipment to the plant chilled water system and provides outlet water temperatures to within a 5 degree approach to the chilled water. Can incorporate automatic backup chiller control. Simple, refrigeration-free system All non-ferrous piping, factory engineered Precise control of flow, temperature and pressure Optional city-water switch over built right in

Reliability & service, designed in. Refrigeration Controls Copeland Scroll compressors for higher reliability Pump down to eliminate liquid migration Flooded head pressure maintains head pressure in any ambient. Effective from 105 to minus 20 degrees. ORD valve for effective head pressure control Correct refrigeration piping using pipe benders ALL non-proprietary components - available worldwide. Competitors use hard to obtain components! Water and Flow Controls Pressurized large volume reservoir for temperature stability. Includes vacuum vent and pressure relief. Large tank volume may be used as expansion tank Stainless-steel single or multi-stage pump. NO pumps in series or oversized pumps to achieve system pressure. Redundant lead/lag pumps available. Circuit setter included and pre piped. Allows flow balancing internally and adjustable external flow rate. External, non-immersed evaporator prevents hardto-access proprietary component. Provides correct fluid velocity across evaporator for higher efficiency. Electronic System Controls Microprocessor based system has much higher reliability than analog based systems. Enabled use of flow, pressure and temperature transducers for precise control. Includes Schrader valves for field replacement without evacuation and recharge Phase monitor included and part of control system. Phase errors are shown and recorded as alarms. Removable cover compressor contactor permits point inspection during preventative maintenance. Communications options includes BacNET, ModBUS, LonWorks and ChillerNET. Others available.

ChillerNET, Advanced Web-Based System ChillerNET allows chillers equipped with an our optional Ethernet interface to notify internal staff, representatives, 3rdparty service contractors and customers of alarms and abnormal operational conditions of a chiller, or entire system. Communicating with remote chillers across the Internet using a simple web browser is only half the news. What makes ChillerNET truly unique is its advanced duplex capabilities and user definable alerting technology. Monitor and control remote chillers from the Web. 100% web-based, worldwide accessibility. View operation, performance, alarms and analog values in near-real time. Make changes to any read/write port in real time. Change setpoints, reset alarms, enable functions. Allow 3rd-party contractors to view certain screens. Subscribe to chillers, alarms and analog value changes. Know about changing conditions before a shut-down. Automatically receive email alerts, SMS coming soon. View real-time Flash graphs showing performance activity and trends over time. View logs of SET and CLEARED alarms and switches. Set up security levels for users. Works with any ModBus enabled controllers Know us by the customers we serve and the company we keep Nothing speaks louder than the trust and long-term loyalty from customers. In a world where competitors are a click away, we know our niche is in creating higher value by producing close performance highly reliable and attractive products using innovative designs, combined with advanced services. We are honored to be a supplier to these and many other fine companies.

M-Series Chillers - Specifications Component Standard Specifications Optional Specifications Cabinet Controls and Safeties Electrical Indicators Refrigeration Air Cooled Condensers Water Cooled Condensers Evaporators Compressors Reservoirs Pumps Models 2 through 5 ton have all aluminum, reinforced metal cabinet and frame of white epoxy painted aluminum. 7.5 tons and above have welded steel frame and white epoxy painted aluminum panels. Easy access hardware. Microprocessor controller with 4x20 LED interface for all chiller operations and alarm status. Includes internal logging for 100 alarms. Remote alarm indicator panel. Power supply phase monitor. Models can be specified for 208-230/50 or 60 Hz, single phase. Three phase service is available for 208/ 230/460/50 or 60 hz, 380/50/3 or 575/60/3 operation. 24 volt control circuit. Water temperature, pump and refrigerant pressure, low tank, high temp and no flow alarms. Remote start/stop and dry contact for general alarm notification. Single R-22 circuit includes filter dryer, receivers with 90% capacity, hot gas bypass capacity control, and service valves. Enhanced seamless copper tubing. Mechanically bonded aluminum fins. Integral sub cooling. Overload protected TEAO fan motors. Aluminum fans. Coaxial type through 10 tons. Cleanable shell & tube heat exchanger on larger models. Coaxial type through 5 tons. Direct expansion shell & tube on larger models. Closed cell insulation. Hermetic scroll or reciprocating types. Internal overload protection. Crankcase heaters and service valves. High volume, insulated stainless steel with vacuum vents and pressure relief valves. All stainless steel, high head pressure, end suction centrifugal designs. Stainless steel cabinet panels Epoxy finishes Custom Colors Engineered frames to accommodate special size restrictions Dual pump lead/lag controls Flooded head pressure controls for low ambient conditions to -40 F Remote web-based diagnostics Automatic city-water switch over Fused or non-fused disconnect Single phase for large models Special voltages Remote flow rate indication using Microprocessor controls Remote panel with flow, temp, and pressures indicators Alternate refrigerants Redundant circuits with staged capacity control Coated or copper fins for corrosion resistance High ambient designs High altitude designs Special construction materials Shell and tube on smaller models 3-way water regulating valve Special construction materials Shell & tube (small models) Dual circuit evaporators Tandem Scroll sets Multiple circuit designs Lead/lag operation Special tank sizes Remote pump/tank designs Dual lead/lag configurations Higher pressure designs All non-ferrous liquid path Piping Warranty Refrigerant piping is rigid copper with service valves. Insulated suction lines. Water circuit is insulated seamless heavy grade copper. One year parts, five year limited compressor warranty Alternative materials for special fluids and corrosion resistance Extended parts & labor warranty Guaranteed emergency response Factory start-up and maintenance Represented By: 200 Park, Inc. dba ArctiChill 200 Park Avenue Newberry, SC 29108 Phone: (803) 321-1891 Fax: (803) 321-1898 TOLL FREE - 1-800-849-7778 www.arctichill.com