Refrigeration Dryers WDRD

Similar documents
Dryer Products. the total systems approach to air preparation. Liquid Separators, Drain Valves, & Refrigeration Dryers.

Air Preparation Systems PRD Series

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

CRV Variable Operation Refrigeration Dryers scfm

PoleStar Smart Refrigerated Air Dryers don t just cycle, cycle Smart.

Energy Saving Refrigerated Air Dryers SRC Cycling Dryers

F-H Refrigerated Dryers

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

SR Series Refrigerated Dryers SCFM

P3X Series Membrane dryers

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

Easy dry line REFRIGERATION AIR DRYERS. With VSCC exclusive patented variable speed system

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

Refrigeration dryers for energy efficient compressed air quality

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

FOCUSED ON COMPRESSED AIR TREATMENT

Refrigerant air dryers. FD series ( l/s, cfm)

Condensate Management Solutions

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

WFH Series. High Efficiency Filters

Downstream Equipment. Intelligent Air Technology

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

UltraDry s Features and Benefits

Lubricated Rotary Screw Air Compressors

Pneumatech: Your guarantee of highquality. air and gas

PNEUDRI High Efficiency Compressed Air Dryers

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm)

ES-6. Encapsulated Rotary Screw Air Compressors. 4 7 kw 5 10 hp

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Compressed Air Filters

OPERATING INSTRUCTIONS

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

RNC Series SCFM Global Air Treatment

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

Pressure Swing Desiccant Dryers

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

DRYAIRE DESICCANT SYSTEM MODEL 6760

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

Nitrogen Generation Systems Compressed Air Dryers

CFH Series High Efficiency Filters

Compressed. air treatment. Refrigerated. compressed air. dryers. Totally Integrated. compressed air. treatment.

Item # /2" NPT, 2 STAGE AIR FILTER/DRYER SYSTEM INSTRUCTIONS

CD36-3D3M CD418-8D3M CD832-16D4M CD25-2D3M CD38-3D1M CD625-12D3M 09-13

Devair and Miscellaneous Table of Contents

ThermoStar Refrigeration Air Dryers

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

ES-6 S-energy Encapsulated Rotary Screw Air Compressors

NEWGATE TECHNOLOGIES, INC.

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

CH750, CH751 & CH951 CHILLERS

Screw Compressors. S Series. Capacities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Air treatment solutions. Aftercoolers & condensate treatment

Desiccant Air Dryers. Heatless, Heated and Heated Blower

Flexible Solutions for Air Quality

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

PNEUDRI High Efficiency Compressed Air Dryers.

Nirvana. Cycling Refrigerated Dryers

Catalog 9CW-SD-9 Manual Desiccant Dryers Models X0, X0, X0 and X5 Wilkerson's Manual Desiccant Dryers offer the most cost effective method to remove m

Modular Compressed Air Dryers. xebecinc.com

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Non-Cycling Refrigerated Air Dryers. HPRplus SERIES 100 to 3000 scfm (170 to 5097 nm 3 /h)

refrigeration drying solutions

Refrigerated Air Dryers

ES2000 Series. Oil / Water Separators ENGINEERING YOUR SUCCESS. mb air systems ltd

CNC Series Refrigerated Air Dryer CFM

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

Chapter 9: The basics of air preparation

QUALITY DRY AIR. Atlas Copco Air dryers SOLICITAR INFORMACIÓN MILLIE LÓPEZ ANTONIO ARROYO. FD refrigeration air dryer series Hz (477)

the condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS

Model OP155 Air Dryer

Installation Instructions

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

R100 Oil-Less Refrigerant Recovery Unit

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems


RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

RNC Series SCFM Global Air Treatment

New standard in compressed air treatment, providing Energy Savings up to 99%

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Clean, Dry Air System

REFRIGERATION AIR DRYERSDW DW 2-420

Filters & Centrifugal Separators

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

Transcription:

Refrigeration Dryers WDRD Series Refrigeration Dryers WDRD Key Features: n Plug & Play Design for Easy Installation and Operation (WDRD10 - WDRD125). n Small Space Saving Design. n Oversized Demister Separator Resulting in Excellent Liquid Removal Over all Operating Conditions. n Low Pressure Differential Across The Dryer (1.45 PSIG Average). n Environmentally Friendly Refrigerant. n Oversized Condenser to Operate in Ambients to 122 F (50 C). n All Models Incorporate a Dewpoint Indicator. WDRD10-175 Why Refrigeration Dryers? Compressed air is an important provider of energy for industry; what is often overlooked however is the need to provide quality treatment for this air. Compressed air contains condensate which, when cooled, will turn into water, causing extensive damage to both the compressed air network and the finished product itself. WDRD refrigeration dryers actively remove this condensate to achieve near perfectly dry compressed air. The benefits are notable: less system downtime, reduced costs and maintenance, and an improved finished product. WDRD, thanks to its PlusPack heat exchanger (patent pending) and the most compact dimensions on the market, will prove a major asset in your factory. Model Selection Model Number WDRD10 WDRD15 WDRD25 WDRD35 WDRD50 WDRD75 WDRD100 WDRD125 WDRD150 WDRD175 Pipe Size 3/4" NPT-F 3/4" NPT-F 3/4" NPT-F 1-1- 1- Recommended Filtration F2804WDRD F2806WDRD F3908WDRD Consists of: Particle & Coalescing Filter Assembly with Mounting Bracket. 13

Refrigeration Dryers PlusPack Heat Exchanger (patent pending) The revolutionary PlusPack features a 3-in-1 aluminum design with integral air connections. All models include an air-to-air freecooler, while the unique slowflow demister ensures perfect dewpoints whatever the operating conditions. WDRD Series Demister Separator A high capacity demister separator is employed for the removal of condensed liquids. This lowers the air velocity which maximizes the condensate separation from the air, even when the dryer is not operating at maximum flow. This design also ensures the differential pressure across the dryer is kept to a minimum. Refrigerant Condenser Oversized high efficiency air cooled condenser. Re-positioned to improve reliability and reduce the risk of dirt contamination. Condensate Drain Niche The WDRD Refrigeration Dryer range comes standard with a level sensing automatic float drain. Other drains are available upon request. The positioning of the drain niche allows for easy access to the drain without the requirement of removing panels. Refrigerant Compressor Maintenance free hermetically sealed refrigerant compressor. Low refrigerant charge eliminates the requirement for pre-heating on start up & prevents any liquid refrigerant returns. Assured Quality & Performance Every dryer undergoes sophisticated testing, including dewpoint tests with compressed air flow. Multiple helium leak testing, again on every dryer, ensures years of troublefree operation. 14

Technical Specifications Refrigeration Dryers - WDRD Series Energy Efficiency Poorly constructed heat exchangers and liquid separators create a high pressure differential across the dryer which leads to high operational costs and poor dewpoint performance. The WDRD dryer range utilizes advanced heat exchanger and demister separation technology and delivers uncompromising performance at the lowest cost of ownership. Moisture Separation Technology Separation Efficiency slowflow demister moisture removal centrifugal separator demister separator Air The oversized slowflow demister is non-velocity sensitive and therefore offers excellent liquid separation whatever the airflow. 15

Technical Specifications (Revised 01/28/10) Refrigeration Dryers - WDRD Series Technical Information Maximum Ambient Temperature... 122 F (50 C) Maximum Inlet Temperature Models WDRD10 thru WDRD175:... 149 F (65 C) Minimum Ambient Temperature... 41 F (5 C) Maximum Inlet Pressure Models WDRD10 thru WDRD175:...232 PSIG (16 bar) Refrigerant Models WDRD10 thru WDRD175:...R134a Model Number Pipe Size Nominal Flow* SCFM Nm 3 /hr Nm 3 /min Primary Voltages Recommended Filtration WDRD10-115160 10 17 0.3 115V/1ph/60Hz WDRD15-115160 15 26 0.4 115V/1ph/60Hz WDRD25-115160 25 43 0.7 115V/1ph/60Hz WDRD35-115160 35 60 1.0 115V/1ph/60Hz WDRD50-115160 3/4" NPT-F 50 85 1.4 115V/1ph/60Hz WDRD75-115160 3/4" NPT-F 75 127 2.1 115V/1ph/60Hz WDRD100-115160 3/4" NPT-F 100 170 2.8 115V/1ph/60Hz WDRD125-115160 WDRD125-230160 WDRD150-115160 WDRD150-230160 1-125 212 3.5 1-150 255 4.2 115V/1ph/60Hz & 230V/1ph/60Hz 115V/1ph/60Hz & 230V/1ph/60Hz WDRD175-230160 1-175 297 5.0 230V/1ph/60Hz F2804WDRD F2806WDRD F3908WDRD Consists of: Particle & Coalescing Filter Assembly with Mounting Bracket. *Capacities are based upon: Ambient Temperature...100 F (38 C) Inlet Temperature... 100 F (38 C) Working Pressure... 100 PSIG (7 bar) 16

Technical Specifications Air Flow Correction Factors Capacity correction factors to be used when operating conditions differ from those shown below. To obtain dryer capacity at new conditions multiply nominal capacity* x C1 x C2 x C3 Models WDRD10 - WDRD175 Ambient Temperature (C1) F 60 70 80 90 100 110 120 C 16 21 27 32 38 43 49 Correction Factor Inlet Temperature (C2) 1.34 1.26 1.17 1.09 1.00 0.91 0.82 F 90 100 110 120 140 149 C 32 38 43 49 60 65 Correction Factor 1.24 1.00 0.81 0.67 0.45 0.43 Refrigeration Dryers - WDRD Series Using the correction factors from the tables: Nominal Flow = 25 SCFM C1 = 1.09 C2 =.67 C3 = 1.07 25 x 1.09 x.67 x 1.07 = 19.53 SCFM Or, our 25 SCFM capacity dryer, under these new conditions, will have a new flow capacity of only 19.53 SCFM. If we truly needed to flow 25 SCFM of air, we need to adjust our selection to a bigger dryer. A WDRD35 would have a flow capacity of 27.35 SCFM, making it the proper selection. It is very important to understand the operating conditions under which your refrigerated dryer will function, to make a selection that will give you the desired performance. Working Pressure (C3) PSIG 60 80 100 125 150 175 200 230 bar 4 6 7 9 10 12 14 16 Correction Factor 0.83 0.93 1.00 1.07 1.12 1.13 1.19 1.22 *Capacities are based upon: Ambient Temperature...100 F (38 C) Inlet Temperature... 100 F (38 C) Working Pressure... 100 PSIG (7 bar) B Example: Using Air Flow Correction Factors The WDRD dryers on page 16 have been sized for the following conditions with the stated flows listed in SCFM and Nm 3. Ambient Temperature = 100 F Inlet Temperature = 100 F Working Pressure = 100 PSIG However, many applications are not under these conditions, so we need to understand the use of the Air Flow Correction Factors. These factors allow you to adjust for changes in the ambient temperature, inlet temperature and working pressure. The formula is simple to use, new dryer capacity = nominal dryer flow x C1 (correction factor for ambient temperature) x C2 (correction factor for inlet temperature) x C3 (correction factor for working pressure. We have selected a WDRD25 for our initial dryer for conditions of 100 F ambient temperature, 100 F inlet temperature and 100 PSIG working pressure. We find, however, that the applications conditions really are: Ambient Temperature = 90 F Inlet Temperature = 120 F Working Pressure = 125 PSIG 17 A Weights and Dimensions Model Number Dimensions Inches (mm) A B C Weight lbs (Kg) WDRD10 8.3 (210) 17 (430) 17,7 (450) 42 (19) WDRD15 8.3 (210) 17 (430) 17.7 (450) 42 (19) WDRD25 8.3 (210) 19.9 (505) 19.7 (500) 52 (24) WDRD35 8.3 (210) 19.9 (505) 19.7 (500) 52 (24) WDRD50 8.9 (225) 22.3 (565) 20.5 (520) 58 (27) WDRD75 8.9 (225) 22.3 (565) 20.5 (520) 68 (31) WDRD100 8.9 (225) 22.3 (565) 20.5 (520) 77 (35) WDRD125 16.7 (425) 23.8 (605) 21.8 (555) 115 (52) WDRD150 16.7 (425) 23.8 (605) 21.8 (555) 128 (52) WDRD175 16.7 (425) 23.8 (605) 21.8 (555) 132 (60) C

Safety Guidelines Safety Guide For Selecting And Using Products And Related Accessories! WARNING: FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEMBLIES OR RELATED ITEMS ( PRODUCTS ) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAMAGE. POSSIBLE CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS INCLUDE BUT ARE NOT LIMITED TO: Unintended or mistimed cycling or motion of machine members or failure to cycle Work pieces or component parts being thrown off at high speeds. Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device. Explosion Suddenly moving or falling objects. Release of toxic or otherwise injurious liquids or gasses. Before selecting or using any of these Products, it is important that you read and follow the instructions below. 1. GENERAL INSTRUCTIONS 1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Valves, FRLs (Filters pressure Regulators and Lubricators), Vacuum products and related accessory components. 1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or property. 1.3. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Wilkerson valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Wilkerson publications for the products considered or selected. 1.4. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Wilkerson and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own analysis and testing, is solely responsible for: Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory. Assuring that all user s performance, endurance, maintenance, safety, and warning requirements are met and that the application presents no health or safety hazards. Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the valves, FRLs or Vacuum products are used; and, Assuring compliance with all applicable government and industry standards. 1.5. Safety Devices: Safety devices should not be removed, or defeated. 1.6. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured. 1.7. Additional Questions: Call the appropriate Wilkerson technical service department if you have any questions or require any additional information. See the Wilkerson publication for the product being considered or used, or call 269-629-2550, or go to, for telephone numbers of the appropriate technical service department. 2. PRODUCT SELECTION INSTRUCTIONS 2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system. System components need to be able to provide adequate flow and pressure for the desired application. 2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, catalogs or the instruction sheets supplied for maximum pressure ratings. 2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product and result in complete product failure. 2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to premature failure of a product. 2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the factory or product literature for materials of construction. 2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures: Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures outside of the rated range. Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols. Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as phosphate ester and di-ester lubricants. 18

Safety Guidelines 2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see technical bulletins Tec-3, Tec-4, and Tec-5 2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage. Do not connect pressure regulators or other products to bottled gas cylinders. Do not exceed the maximum primary pressure rating of any pressure regulator or any system component. Consult product labeling or product literature for pressure rating limitations. 3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS 3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any signs of nonconformance. 3.2. Installation Instructions: Wilkerson published Installation Instructions must be followed for installation of Wilkerson valves, FRLs and vacuum components. These instructions are provided with every Wilkerson valve or FRL sold, or by calling 269-629-2550, or at. 3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient temperature can drop below freezing 4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS 4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or replacement of products so that products are replaced before any failure occurs. A maintenance program must be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10. 4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Wilkerson valve and FRL sold, or are available by calling 269-629-2550, or by accessing the Wilkerson web site at. 4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more information see: OSHA Standard 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy (Lockout / Tagout) 4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged components: Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an indication of worn or damaged components. Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation. Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior. Any observed improper system or component function: Immediately shut down the system and correct malfunction. Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations. Caution: Leak detection solutions should be rinsed off after use. 4.5. Routine Maintenance Issues: Remove excessive dirt, grime and clutter from work areas. Make sure all required guards and shields are in place. 4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate properly and safely. 4.7. Service or Replacement Intervals: It is the user s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need to be established based on: Previous performance experiences. Government and / or industrial standards. When failures could result in unacceptable down time, equipment damage or personal injury risk. 4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal injury and property damage: Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout Tagout procedures (OSHA Standard 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy Lockout / Tagout). Disconnect electrical supply (when necessary) before installation, servicing, or conversion. Disconnect air supply and depressurize all air lines connected to system and products before installation, service, or conversion. Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied. After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into use. Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local representative for replacement labels. 4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance instructions supplied with the valve FRL or vacuum component to insure proper function of the system. 19