Feuchtigkeits-Detector Moisture detector. Operating Instructions... 6

Similar documents
6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Refrigerant Leak Detector

DIGITAL KITCHEN SCALE

alerting transmitter user guide other resources online at

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

VISION H. Instruction manual

User Manual. GPD 3000 e. gas detector

MULTI HAIR TRIMMER MT 5210

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

INSTRUCTION MANUAL 1

WIRELESS DIGITAL DOOR

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

ELECTRICAL. Stud Detector User Guide

User Guide. 2 in 1 Cordless Stick Vac DSV-SW-SA DSV-SW-HKA. DD16175_DDST12V_UserGuide_Singapore_ indd 1

SENSIT HXG-2d Combustible Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Operator's Manual. LIGHTNING 2 Laser Detector

ASSEMBLY AND INSTRUCTION MANUAL (EN)

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Alarm System SECURE AS 302

OPERATING INSTRUCTIONS

K B L M N P F H** G1* *Nozzle design may vary according to models **Motorized Nozzle only

The device is not suitable for continuous operation, but only for short-time operation (note lifetime of battery).

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

No Touch Door Release Exit Sensor ACA-NTEB

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

testo 316-EX gas leak detector Instruction manual

DIGITAL BODY WEIGHT SCALES PS 4110

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

EN Bagged Vacuum Cleaner

AA Z** V2** W** U1* V** U2** USER MANUAL U* E D L U3* M N S ** T* O Q P P3 P2 P1 R** AD* PRINTED IN P.R.C /01

Contents 1. Helpline No. UK/ North Ireland Rep. Ireland , Web Support Model Number: MD

INSTRUCTION MANUAL CD Fax: (503)

Instruction manual EN

Clock Radio AJ100. User manual

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

Remote alarm unit Art. Nr.:

GB Operating instructions

USER INSTRUCTION MANUAL ACR Alarm Clock Radio Instruction Manual (Read before proceeding)

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

BODY HAIR TRIMMER MT 5531

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Operating instructions for the radio heat detector GS412

INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

Model ST-128M Moisture Detector

User manual INFRARED REMOTE CONTROLLER SIR-15

APS-1650 LEVEL SENSOR INSTALLATION AND CALIBRATION

GERMANY TEC 'LOGY leak-detect EXPERT

- 1- IMPORTANT SAFETY REMINDERS

Compact Cyclonic Pro Bagless Cylinder Vacuum Cleaner

Manual Hygrometer PCE-555

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

on the use of the device and understand the dangers its use involves. User cleaning and maintenance may not be done by unsupervised

IRT2 Dual Laser IR Thermometer - User Guide

Dual Laser InfraRed (IR) Thermometer

INSTRUCTION MANUAL 1

CA N* Q1** T* M* HF P* Q2** O* F T* P* E C O* L D USER MANUAL B V* J GP R K A I X* Q** PRINTED IN P.R.C

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

USER MANUAL Turbopower IM UK.indd /6/5 17:36:44

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Hand Vacuum Cleaner User's manual

Wireless Driveway and Intruder Alert

Electronic Crimping Tools REF Operation Guide

Power 6. vax.com.au vax.co.nz CYCLONIC BARREL VACUUM LET S GET STARTED. VACUUM CLEANER VX71

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

User Manual. Non-contact Infrared Thermometer.

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

Dräger X-am 2500 Multi-Gas Detection

DynamoPower. vax.com.au vax.co.nz DYNAMIC POWERFUL PERFORMANCE, FOR TOTAL HOME CLEANING LET S GET STARTED. TOTAL HOME VX54

IMPORTANT SAFETY REMINDERS

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Precision Infrared Thermometer. Users Manual

Professional HEPA Air Cleaner

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

PET CLIPPER & TRIMMER KIT

- 2 - IMPORTANT SAFETY REMINDERS

Emit Owners Manual Loudspeakers

Detailed operating instructions

NGD8800 USER S MANUAL

TE 2 TE 2-M TE 2-S. English Français Español Português

Steam Station. Instruction Manual THE SCIENCE BEHIND CLEAN.

Electronic Crimping Tools

Voltage module +SBEC S8446

Manual. PDB + SBEC Module Voltage, Current, Capacity, Telemetry. No. S8474. Copyright Graupner/SJ GmbH

Operating Manual Bathroom Balance

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

AlcoBlow. User Handbook

Transcription:

Feuchtigkeits-Detector Moisture detector MD Operating Instructions... 6

Operating Instructions INTRODUCTION This moisture meter is a useful instrument, for determining the moisture content of wood or construction materials such as concrete, tile, screed, plaster, carpets, etc. Prior to operational start of the device, read the following instructions carefully and keep them for future reference. Protective cap Measuring probe Moisture level indicator: Low Middle Hight Wood display Construction materials display»acoustic signal on/off«display On-/off switch: Hold longer than three seconds to turn on or off. Low battery indicator»hold«-function display to»freeze«measured values Selector button: For switching from»wood«to»construction materials«and back»hold«-button: To»freeze«the measured values, press and hold for ca. 1 second, the next push turns the function off again. To turn the acoustic signal on and off, press and hold for longer than three seconds. Battery cover (back) Operation Note: Be aware that the probe tip can cause injuries if used incorrectly. Put the protective cover back on when the device is not in use. Keep the moisture meter away from children! Inserting the Battery: Remove the battery cover and insert a new battery (9V DC alkaline block battery). Make sure you connect the poles correctly. 6

MD Operating Instructions When the low battery alert» «appears in the display window appears, the battery must be replaced with a new one. When disposing of used batteries, please observe your local legal stipulations. Performing measurements: 1. Remove the protective cover and place it on the underside of the device. 2. Press and hold the on/off switch» «until the display appears in the display window. Select wood» «or construction materials» «by pressing the selector button» «. Insert the probe tip into the material to be tested (e.g. wood) and read the value in the display window. At the same time, an acoustic signal should sound. The higher the tone, the higher the moisture content. Press the»hold«-button once» «to»freeze«the display in the display window. This can be useful if you wish to perform a reading in conditions of darkness or poor visibility. The symbol» «will appear in the display window and the reading will be displayed until the»hold«-button» «is pressed again. Press down the»hold«-button» «for longer than 3 seconds to turn the acoustic tone on or off. SAMPLE USES Locating a leak in the wall Place the probe on the surface to be tested. Take a reading and read the value from the display window. Repeat this procedure in various places. If the readings get higher, then you are getting closer to the leak. If the values stop increasing, you ve found the leak. Check the moisture content of construction materials e.g. concrete, tile, screed, plaster, carpets prior to finishing. 7

Operating Instructions MD Check the moisture content of wood e.g. of firewood or wood as a building material Determining the moisture content of soil Use the setting for construction materials IMPORTANT NOTICES Place the probe tips on the surface carefully, do not apply force. Handle the device carefully when the protective cap has been removed. The probes can cause injuries if used improperly. Soil Soil When measuring soil, you will get low readings if the readings are only taken at the surface and higher readings the deeper you press the probes into the soil. The measured value will differ significantly if you take readings in loose or tightly packed flower garden soil. Metal If the probes are set on a metal or a conductive surface, the maximum value of >>50<< or >>33<< will appear in the display. Keep the probes clean using a damp cloth and put them back in the protective cap. 8

MD Operating Instructions TECHNICAL DATA: - Power source: 9V DC alkaline block battery (not included in this package) - Automatic shut-down: after 3 minutes - Measurement range: 5% - 50% (wood); 1.5% - 33% (construction materials) - Resolution: 0.1% - Precision: +/ 3% - Reference values for moisture content: Moisture Content wood (%) construction materials (%) 5 50 % 1,5 33 % Low 5 11,9 % 1,5 16,9 % Middle 12 15,9 % 17 19,9 % Hight 16 50 % 20 33 % Disposal Please dispose of your used electronic devices in an environmentally friendly manner! Electronic devices do not belong in your household waste. compliant with European Guideline 2002/96/EG concerning Electrical and Electronic Devices, used electronic devices must be collected separately and taken to a facility for environmentally sound recycling. You can find out about your options for disposing of your used electronic devices from your community or city government. Improper disposal of batteries can harm the environment! Batteries do not belong in your household waste. They can contain poisonous heavy metals and are subject to treatment as hazardous waste. For this reason, please take your used batteries to your local collection site. 9

Brennenstuhl GmbH & Co. KG 72074 Tübingen Germany www.brennenstuhl.com 0451781/609