ESPE Electro-Sensitive Protective Equipment

Similar documents
Non-contacting guards

British Standards for Machinery Guarding

Where Process Safety meets Machine Safety

Introduction to machine safety

Safe Machines with opto-electronic protective devices. Reliable safety and flexibility in an advanced manner.

On Your Guard. Machine Safety. A Designer's Guide to Machinery Guarding Standards. 12th edition - March 2018

Australian Standard. Safeguarding of machinery

ICS Supersedes CLC/TS 62046:2005. English version

On Your Guard. Machine Guarding. A Designer's Guide to Machinery Guarding Standards. 11th edition - March 2016

SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Guide to Membership Assessments

Introduction to machine safety

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Functional Safety of Machinery: EN ISO Stewart Robinson. Overview of the presentation. References. TÜV SÜD Product Service

MACHINERY SAFEBOOK 5. Safety related control systems for machinery. Principles, standards and implementation. (Revision 5 of the Safebook series)

Machine Guarding and Safety

SAFETY RELAY APPLICATION

Safety Function: Single-beam Area Access Control (AAC)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Periodic Electrical Testing Policy

Your specialist partner for total electrical compliance. Electrical Testing

THE SAFE USE OF ELECTRICITY

FORMATIC Instruction Manual

Statutory Compliance Checklist

PERIODIC ELECTRICAL TESTING POLICY

EU DECLARATION OF CONFORMITY. 3. This declaration of conformity is issued under the sole responsibility of the manufacturer.

Using Height Access Poles for Safe Testing Of Fire Detection Systems

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

New requirements for IEC best practice compliance

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Swaging Machine Type H50-46ECO

Guide to gate safety legislation and standards

DHF Introduction DHF 2

ISLE OF WIGHT FIRE & RESCUE SERVICE

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

ISO INTERNATIONAL STANDARD. Graphic technology Safety requirements for graphic technology equipment and systems Part 1: General requirements

CE marking & your legal obligations

Original instructions Sense7-series Non-contact coded safety switch

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

OPERATING MANUAL UNIT 8 - WHITEBRIDGE INDUSTRIAL ESTATE STONE STAFFORDSHIRE ST15 8LQ ENGLAND TEL: +44 (0) FAX: +44 (0)

GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

FORMATIC Instruction Manual

We make your Workplace Safe

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

/ / 2018

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

dhf General Information Automated Gates Guidance for enforcement bodies

GuardShield PAC Type 4 (Perimeter Access Control) Safety Light Curtain User Manual

Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus.

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Design-In Health and Safety Guarding. Thermal April 2010

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

CEN standardization work on refrigerating systems, especially standard EN 378

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

COMPANY PROFILE ENG LIGHT - REV

TECHNICAL SPECIFICATION

Press Machine Safety Guide

Selecting Safeguards

XB-EFA-8L-BK & XB-EFA-8R-BK

The Minor Servicing Exemption LOTO s Misunderstood Requirement

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

Digital Electronic Thermostat With RF

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

Connection of CES-AP to safety relay PNOZ s4.1 Content

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

order code: EQLA08 user manual

Safety Sensor Eden AS-i Machine safety - Jokab Safety products

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

Electrical Safety Policy and Management System

230v Dial Thermostat Instruction Manual

ESRTD2 Electronic Room Thermostat, with LCD Display

For Building Managers: outsourcing the maintenance of fire safety and security systems

Testing and Calibration Report

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

BUSINESS PLAN CEN/TC 159 HEARING PROTECTORS EXECUTIVE SUMMARY

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

Digital Room Thermostat

SAFETINEX SAFETY LIGHT CURTAINS HAND PROTECTION, TYPE 2 YBB, YBBS SERIES INSTRUCTION MANUAL


Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Firetex steel fire shutters

BS 5839: Part THE CHANGES

For full product information, visit Use the SpeedSPEC Code for quick access to the specific web page. Global Support

DBF 4XL Dryer Booster Fans

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Part 4. Safe Hospitality. Safety, Health & Welfare in Hotels, Restaurants, Catering & Bars. Part 4 - Accommodation and Housekeeping

SALAMA SAFETY SIGNS SALAMA SAFETY SIGNS SAFETY SIGNS PHOTOLUMINESCENT

SEC Signature Process Gas Analyzer

Electrical connections for gas metering equipment

Fire Safety. A TUC guide for trade union activists

NEW. ECO WELFARE UNIT Compact. Sustainable. Portable.

KNOW HOW. Technological excellence and application know-how embody the spirit of ReeR Safety Division.

Mains Supply Guard User Manual

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

Transcription:

ESPE Electro-Sensitive Protective Equipment Presented by Simon Deighton Business Development Manager, Safety Systems Technology, Part of the machinery division of TÜV SÜD Product Service

Our Services: Project Management Electrical Engineering Machine Guarding Safety Products Machinery safety training Commissioning and installation Safety circuit upgrades ESPE Testing

Electro-Sensitive Protective Equipment (ESPE) using Active Opto-electronic Protection Devices (AOPD) for safeguarding machinery. An AOPD is a light curtain and/or light beam device and can be used alone or in combination with other safeguards depending on the application.

Devices: - Light curtain ( AOPD ) - Light beam device ( AOPD )

Why Use A Light Curtain Ease of access. Visibility. Setting. Increased productivity. Ability to detect a person but allow a product to pass. Secondary guarding Muting.

When Not To Use A Light Curtain Cost. Machine Stopping Performance. Inability of machine to stop part way through a cycle. Environmental considerations. Ejection of parts.

Functions & applications An AOPD may be used as: a)a trip device: b)a combined trip device and presence-sensing device: and c) A presence-sensing device. An AOPD should not be regarded as a substitute for primary isolation and safe systems of work during plant maintenance.

PUWER: Regulation 6 Inspection (1) Every employer shall ensure that, where the safety of work equipment depends on the installation conditions, it is inspected - (a) after installation and before being put into service for the first time. (2) Every employer shall ensure that work equipment exposed to conditions causing deterioration which is liable to result in dangerous situations is inspected - (a) at suitable intervals.

Health and Safety Executive (HSE) HSG180 This publication is provided for guidance only PUWER inspections may not be enough for them to meet their legal obligations in respect of machinery safety, Special requirements apply to machines that have ESPE People arenot fully aware of their ESPE requirements Regular PUWER assessments are not enough Installations using ESPE should be inspected at suitable intervals

Testing The recommended maximum interval between each periodic inspection and test is: six months for type 4 ESPE twelve months for type 2 ESPE This interval will also depend on the equipment it is fitted to and the risk as a whole. There multiple factors that determine how often ESPE should be inspected/tested, in many cases will be more often that any routine PUWER assessment on the machine.

Testing Inspect and test machine control elements. Position of the light curtain ( distance ) Response time Detection zone Stopping performance Record of test inspections

Knowledge Know the correct distance from the danger zone? Test the response time and detection capability of the ESPE installation. Inspect any stopping performance monitor that may be fitted, and testing primary machine control elements to ensure correct functioning. in-house competence

Standards EN ISO13855 (EN999) Safety of machinery - The positioning of protective equipment in respect of approach speeds of parts of the human body 3.1.8 detection zone: zone within which a specified test piece is detected by the protective equipment. 3.1.9 minimum distance: calculated distance between the safeguard and the hazard zone to prevent a person or part of person reaching the hazard zone.

Calculations: normal approach The separation distance from the danger zone should be calculated by using this formula:- S = (K x T) + C where: S is the separation distance, in millimetres, from the danger zone to the detection point, line, plane or zone; K is a parameter, in millimetres per second, derived from data on approach speeds of the body or parts of the body; T is the overall system stopping performance in seconds; C is an additional distance, in millimetres, based on intrusion towards the danger zone prior to actuation of the AOPD.

Application images:

Application images:

Service ESPE periodic inspection and test service that can be tailored to suit the requirements of individual sites. This service accurately follows the guidance given in HSG180 and includes inspection of the ESPE to that ensure that it conforms to the HSE guidance

Simon Deighton Business Development Manager, Safety Systems Technology, Part of the machinery division of TÜV SÜD Product Service Tel: +44(0)8450 750008 s.deighton@safetysys.co.uk www.safetysys.co.uk ww.tuvps.co.uk