INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Similar documents
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Demand Control Kitchen Ventilation Cameron Ritzenthaler, Air Solutions & Balancing, LLC

David Reynolds, Business Development Manager. Halton Group Foodservice Division

Demand-Controlled Ventilation for Commercial Kitchen Ventilation

Variable Ventilation for the Kitchen:

Sustainability Best Practices for HVAC Retrofits. Cal Poly State University, San Luis Obispo. Presented to the UC/CSU/CCC Sustainability Conference

DEMAND CONTROL KITCHEN VENTILATION

DemandAire. amaximize Energy Efficiency aincreased Kitchen Comfort acustomizable Systems. Demand Control Kitchen Ventilation System

DEMAND CONTROL KITCHEN VENTILATION

Demand Controlled Kitchen Ventilation (DCKV) [Strategy]

GreenJet Transfer Fans

Demand Control Ventilation What, When and Where?

Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

Customer Advanced Technologies Program Technology Evaluation Report

Continuous Commissioning: A Valuable Partner to Retrofit Projects

48 50 UH UA PACKAGED ROOFTOP

Test, Adjust, and Balance Services Submittal

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

FOOD SERVICE EQUIPMENT REBATES

Revolving Oven Gas Wood Model 140

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

COMcheck Software Version Mechanical Compliance Certificate

for commercial kitchen ventilation

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Digital Precise Air Control - DPAC

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

COMcheck Software Version Mechanical Compliance Certificate

Demand-Controlled Ventilation For Commercial Kitchens

Commercial Kitchen Ventilation (CKV) Design and Recent Innovations and Developments in the Industry.

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

COMMERCIAL KITCHEN FIRE SAFETY

Paul McCown, PE, CEM, LEED AP, CxA Sr. Mechanical Engineer SSRCx, LLC Nashville, TN USA

COMcheck Software Version Mechanical Compliance Certificate

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Excellent Ventilation for Professional Kitchens

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Energy Recovery with Cooling and Heating

City of Duluth Festival Center 04/25

Engineers and Contractors - Innovative Technologies to Achieve Highest GeoExchange System Efficiencies for Commercial Projects

Illini Union Exhaust Hood Conversion University of Illinois at Urbana-Champaign U12241

EC Fans Growing in Popularity

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Energy Saving Results for Cheetah. Cheetah Energy Saving in Commercial Kitchens

MCH Series Drives. HVAC Application Guide. ag-mch-e2

Energy Efficient Fan and Dust Collection Systems

THE ULTIMATE ROOFTOP SOLUTION

CxA to Answer this Section

Kitchen Ventilation & HVAC Efficiency Solutions. Click to download presenta1on

Job Name Control Systems Description Date

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

TrueAlarm Analog Sensing

Introduction to Fans. The Basics of Fan Principles and Terminology

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

FOUNDATIONS OF MODERN KITCHEN VENTILATION (CKV) DESIGN HANDBOOK

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

MSYS 4490 AC Systems

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

HVAC Controls Upgrades: Requirement Details ( )

IMC Significant Changes Summary Tier I

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

COMcheck Software Version Mechanical Compliance Certificate

4310 N. 126th Street Brookfield, WI (USA) Phone: (262) ~ Fax: (262)

Innovative Technology Drives Real Results

UNDER CABINET RANGE HOOD

Commercial Fryers Buying Guide

Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

CHAPTER 5: EXHAUST SYSTEMS

COMcheck Software Version Review Mechanical Compliance Certificate

Energy-Saving Demand Ventilation System

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

DEMAND CONTROLLED VENTILATION WITHOUT WIRES

MAXA-MI$ER Energy recovery solutions

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

COMcheck Software Version Mechanical Compliance Certificate

Exhibit J. Subcontract Agreement No.

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

TrueAlarm Analog Sensing

Beacon for Urban Waters. Science for Sustainability. Inside The Path to a Net Zero-Ready School

Kitchen Ventilation Hood Permit Application

COMcheck Software Version Mechanical Compliance Certificate

Plenum Fans. Model HPA. Direct Drive

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards

Civil Engineering Building

Transcription:

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

COMMERCIAL KITCHEN VENTILATION EXPERTS FOR OVER 25 YEARS

WHO WE ARE WE REALLY UNDERSTAND AIRFLOW IN YOUR KITCHEN Extensive experience with all kitchen hood manufacturers including design, installation, and sales of hood systems. WE KNOW ENERGY EFFICIENCY FOR YOUR KITCHEN HOODS Certified Energy Manager (CEM) Certified Energy Auditor (CEA) MEASUREING AIR FLOW IS ALSO OUR BUSINESS Nationwide NEBB certified testing, adjusting, and balancing with a specialty in commercial kitchens.

YOUR TRADITIONAL KITCHEN HOOD SYSTEM Kitchen hood Exhaust fan (either belt or direct drive) Make-up air unit (either heated air or not) Simple on / off switch for your fans Is your team shutting off the fans at night? If yes, then you are still leaving money on the table If no, then you are leaving a LOT of money on the table

WITHOUT HOOD CONTROLS: ZERO OR FULL SPEED

WHAT IS DCKV TECHNOLOGY FOR A HOOD? (Demand Control Kitchen Ventilation)

KEY COMPONENTS: TEMPERATURE SENSOR Senses temperature changes in the hood & ductwork Used for both cooking & auto on / off capability Programmable temperature spans Ease of installation in hood ductwork or top of hood

KEY COMPONENTS: OPTIC SENSOR Blue Light Optical Sensors Senses extremely small smoke & steam particles in the hood Ease of installation Auto calibration Ease of cleaning & responsiveness

WHAT ABOUT MAINTENANCE?

KEY COMPONENTS: MODULATING DAMPER Retrofitted into pre-existing ductwork Adjustable to fit existing conditions Fully-closed to fully-open in under 4 seconds Access panel installed when needed Offers additional energy savings

KEY COMPONENTS: VARIABLE FREQUENCY DRIVE ABB, Yaskawa, we love them all! With or without electronic bypass. Your choice! Every VFD manufacture is compatible.

INTELLINOX FEATURES & APPLICATIONS

KEY FEATURES Temperature sensors, Optic sensors & Modulating Dampers Prep Mode, Cooking Mode, Cooldown, & Idle Constant auto calibration of Optic sensors Automatic On, Off & sensor monitoring Ease of maintenance & cleaning Integration with Building Automation System Versatility of component installation

APPLICATIONS BOTH NEW CONSTRUCTION & RETROFIT ALL HOOD SIZES & TYPES ALL EXHAUST FANS & MAKE-UP AIR UNITS WITH 3-PHASE MOTORS

FOLLOWING ALL CODES FOLLOWING ALL STANDARDS NFPA96 National Fire Protection Association IMC International Mechanical Code Access panel for dampers Devices with duct penetration listed UL1978 Min air velocity 500ft/min in any duct Air balancing UL710 Exhaust hoods for commercial equipment UL1978 Grease ducts UL2017 General-purpose signaling devices and systems Lower exhaust air volume when not cooking Listed dampers permitted in ducts

ENERGY SAVINGS & BENEFITS

ENERGY SAVINGS & BENEFITS Average new fan speed of 65% (Temp & Optics) Average new fan speed of 50% (Temp, Optics & MD) Conditional air savings Up to 70% Average payback 1 to 3 years Improved Safety with auto on & off capability Improved Comfort with reduced hood air noise Sustainability by helping to achieve LEED credits Can qualify for local Utility Rebates

CASE STUDY: RESTAURANT SCENARIO Local restaurant 1 hood 2HP exhaust fan 1HP MUA fan Retrofit Install time: 2 nights

CASE STUDY: RESTAURANT SCENARIO Installed cost: $9,890.00 Motor operating savings: Heating savings: Cooling savings: $1,001.00/year $2,319.00/year $24.00/year TOTAL SAVINGS: PAYBACK PERIOD: PAYBACK WITH UTILITY REBATE: $3,344.00/year 3.0 years 1.5 years

TREND DATA: GARDNER MIDDLE SCHOOL 10 9 8 7 6 5 KEF-1 4 3 2 1 0 3/1/2017 3/3/2017 3/6/2017 3/8/2017 3/11/2017

% Speed TREND DATA: NICHOLS COLLEGE 100 90 80 70 60 50 40 30 20 10 KEF-1 KEF-2 MUA-1 0 11/01/2014 11/03/2014 11/05/2014 11/07/2014 11/09/2014 11/11/2014

AIR SOLUTIONS & BALANCING

WHAT WE OFFER Complete turnkey installations of Intellinox systems All in-house labor by licensed electricians Complimentary walkthroughs & site visits In-house design engineering services Free energy analyses Over 15 years demand ventilation installation experience Hood performance testing Free onsite support for one year Permanent free phone support

CONTACT AIR SOLUTIONS OLAF ZWICKAU Olaf@USAbalancing.com T 603-262-9292 USAbalancing.com 40 King Street Unit 1, Auburn NH