SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 *

Similar documents
Model Policy On Portable Fire Extinguishers (Ontario Version)

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Design & Construction Standards, Revised January

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973

NFPA 1124 (2006 Edition) Compliance List. Permanent Facility

NFPA 1124 (2006 Edition) Compliance List. Permanent Store

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

d. Portable water heaters used exclusively for underwater diving operations.

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

Flammable and Combustible Liquids Checklist

Portable Fire Extinguishers

Capital Projects Group Fire Extinguishers Specification

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

ALABAMA Propane Gas Association

Risk Management Resources

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

COMDTPUB P NVIC JUNE 1995

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

Fire Prevention Plan

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

APPUZO RANGE HOOD INSTALLATION

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

Stillwater Area Community Services Center Inc.

FM-200 In-Cabinet Series

Statement of Policy. Fire Extinguisher Use Policy #: SMS-041

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Cannabis Business License Project Description

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Fire Safety Plan (FSP) Review Checklist 1

Outdoor Festival and Special Event Guidelines

Appendix 3 Fire Suppression Systems For AASA sanctioned events V0.1

Spark Extinguishing Systems

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

At its meeting of August 7-9, 2012, the Standards Council considered the above referenced matter.

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

D. Reference Standards (Utilize latest editions available):

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

Little Helios. Use Instructions Portable Barrel Burner. Toll Free: Phone: (+1)

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Fire Prevention Plan

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

SMOKE ALARMS. Improving the lives of those affected by burn injury

FOOD PREPARATION WITHIN EXHIBITS

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

Fire Safety. Version 1.0

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

SECTION COMMERCIAL-KITCHEN HOODS

WSU-TFREC Fire Safety Training

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

OUTDOOR FIREWORKS DISPLAY

GUILFORD COUNTY SCHOOLS

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

ASSEMBLY INSTRUCTIONS

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Technical Information

Should you have further questions, please feel free to contact the Fire Prevention Branch.

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Plan Submittal Checklist

Hydrostatic Retest Requirements for ANSUL Pressure Vessels

City of Duluth Festival Center 04/25

Shipboard incinerators with capacities up to 4000 kw

Michigan Fireworks. Mike Evans Instructor # 2062 Program approval # A, 1S, 1T

VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)

ASSEMBLY INSTRUCTIONS

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

Department of Public Safety

The blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.

FIRE SUPPRESSION SYSTEM

SPECIFICATION: ARGONITE Engineered Fire Suppression System

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Fire Prevention Plan Program

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

APPLICATION FOR Large Family Day Care Permit

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Chapter 12 HOT WORK OPERATIONS. Purpose:

Residential-based Care Facility R-4 Guideline

COUNTY OF ROCKLAND Department of General Services Purchasing Division

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Appendix J Framework Fire Prevention and Suppression Plan. Prepared by Idaho Power Company 1221 W Idaho Street Boise, ID 83702


PQS Independent type-testing protocol

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

General Safety Training

Twin-Agent Fire Fighting/Securing Systems Specifications

PROTECTION PLAN CONSUMER GUIDE. Heating + Cooling + Plumbing + Appliance + Electrical. Home protection just got simple.

June 2018 Safety Meeting Fire Extinguishers Part I

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

Transcription:

SFI SPECIFICATION 17.1 EFFECTIVE: FEBRUARY 26, 2014 * PRODUCT: On Board Fire Suppression Systems 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and determining performance capabilities for On Board Fire Suppression Systems used by individuals engaged in competitive motorsports. 1.2 The procedures, test evaluations and standards contained herein, are intended only as minimum guidelines for construction and evaluation of products. Certification that products meet such minimum standards is made by the product manufacturer and products are not certified, endorsed or approved by SFI under this program. 1.3 Use of the "This Manufacturer Certifies That This Product Meets SFI Specification 17.1" logo/designation, the authorized artwork style, or conventional lettering by a manufacturer, on a subject product, is intended only to indicate that the manufacturer of the product has represented that they have submitted the product to the recommended tests, with positive results, in compliance with the standards established herein. 1.4 This SFI Specification requires a demonstration that the product of a manufacturer meets or exceeds the requirements when the manufacturer enters the program; and on a periodic basis thereafter. Any manufacturer may participate in the program by providing On Board Fire Suppression Systems that meet or exceed the SFI Specification 17.1 test standards, by complying with the requirements of the SFI Specification 17.1 program, and by signing a licensing agreement with the SFI Foundation, Inc. SFI Specification 17.1 Page 1 Effective: February 26, 2014

1.5 Compliance with this specification is entirely voluntary. However, when a manufacturer provides On Board Fire Suppression Systems in compliance with all requirements of the SFI Specification 17.1 and enters into the licensing agreement with the SFI Foundation, Inc., they may certify that compliance with such standards is in accordance with the guidelines established herein. 1.6 Manufacturers wishing to participate in the program, in addition to the other requirements of this specification, must label each of their products with the manufacturer's name, trademark or symbol as well as the date of manufacture of the product. 1.7 No manufacturer may display the SFI logo/designation on their product unless the manufacturer has signed a licensing agreement with SFI and has successfully complied with all the requirements of this specification and the self-certification program. 2.0 DEFINITIONS 2.1 An On Board Fire Suppression System shall provide fire suppression within a racing vehicle to primarily protect the occupant(s) and secondarily to minimize damage to the vehicle itself. 2.2 Agent: The fluid or gas used to suppress/extinguish a fire. 2.3 Cylinder: The container for the agent. 2.4 Metal Connecting Tubes: The transport medium for the agent from the cylinder to the fire protection area. 2.5 Actuating Mechanism: The device used to initiate the delivery of the agent from the cylinder. 2.6 Class B Fires: Fires in flammable/combustible liquids. 2.7 On Board Fire Suppression Systems shall be inspected for recertification at least every two years after the date of original certification or as specified by the certifying manufacturer. When a unit is determined to be acceptable for continued service, a new conformance label marked with the inspection date shall be used. In-field recertification is permitted, but ONLY by the original manufacturer or its authorized agent. Mailing of certification labels to customers is strictly prohibited. Systems shall have a maximum field service life of 6 years from the original date of installation. At the end of the 6-year period, all systems must be returned to the manufacturer or a certified SFI Specification 17.1 Page 2 Effective: February 26, 2014

recycling service center for lawful disassembly, recycling and decommissioning. No system may be refilled more than 6 times during its 6- year field service life. 2.8 Any On Board Fire Suppression System pertaining to this specification shall remain as constructed and tested by the original manufacturer and not modified. Each manufacturer must provide some means by which to indicate that the cylinder was filled with agent by the original manufacturer. Cylinders may not be filled or refilled by anyone other than the original manufacturer. 2.9 On Board Fire Suppression Systems certified to this specification must be installed according to the system manufacturer s instructions. 3.0 CONSTRUCTION 3.1 TYPE OF AGENT The agent shall be capable of suppressing a Class B fire, defined by this standard as a special hazard. Acceptable agents must be Environmental Protection Agency (EPA) accepted. Dry chemical and carbon dioxide (CO 2 ) are not acceptable as agents under the requirements of this standard. Halon agents are not acceptable as of January 1, 2008. 3.2 MOUNTING Cylinder(s), nozzles, tubing, cables and actuating mechanism(s) shall be located and structurally mounted per certifying manufacturer's requirements and include information such as installation plans and schematics, listed in a technical manual format and be available for inspection at each racing event. The cylinder(s) shall be placed such that they will not be able to contact the race track surface at any time and when cylinders are mounted in any position, pressure gauges must be visible for inspection. 3.3 SYSTEM MAKE-UP Either a single cylinder or multiple cylinder system may be used. In the case of multiple cylinders, the manufacturer's instructions for separate actuation and distribution hardware shall be followed. Also, a multiple cylinder system may rely on the activation of one cylinder to cause the activation of the second cylinder. 3.4 ACTUATING MECHANISM All On Board Fire Suppression Systems shall have a manual, pneumatic, electronic or electrical actuating mechanism operable by the occupant(s). Pneumatic, SFI Specification 17.1 Page 3 Effective: February 26, 2014

electronic or electrical actuating mechanisms must have a back-up manual actuating mechanism. 3.5 MARKING OF CYLINDERS It is required that all suppression systems be designed, manufactured and tested in accordance with 49 CFR, 173.309 and as a minimum incorporate DOT approved cylinders to the following specification: DOT39, DOT3AL, DOT 4B360, DOT 4DS and/or TC 3ALM. Also gross weight, tare weight values in pounds or grams shall be displayed on all cylinders. All labels must be indicate the manufacturer's name and contact information, date of manufacture, contents (type of suppression agent), total cylinder weight, contents (agent) weight. 3.6 CYLINDER STATE Extinguishers shall contain no less than 95% of the stated agent quantity. No system or cylinder shall include a manual agent on-off valve. Cylinders may be made of steel or aluminum, capable of activation at a pressure less than the burst strength of the cylinder itself. All cylinders must have an indicator gauge readily visible for inspection and the gauge must be compatible with the agent used in the cylinder. 4.0 MODEL CLASSIFICATION Any variation in the cylinder material, cylinder size, nozzles, agent, actuation mechanism or internal components is considered a model change and must be tested to initial design criteria. System manufacturer supplied metal fittings substituted for tested non-metal fittings, and system manufacturer approved substitute metal connecting tubes are not considered model changes. 5.0 TESTING Test samples shall be fully processed new suppression systems which are representative of suppression systems currently produced or to be produced. All necessary mounting hardware along with mounting instructions shall be supplied by the certifying manufacturer and used/followed by the test lab for installation/mounting to the test fixture. All tests must be conducted utilizing the test fixture-installed tubing and nozzle locations unless the manufacturer intends to sell the system with larger or smaller tubing or hardware. In which case, the intended tubing and hardware must be used for testing. Test samples must be preconditioned for two (2) hours prior to testing. Sample cylinders must be temperature conditioned to 70 F ± 5 F before testing. Actual fire testing must be conducted within an indoor laboratory temperature of 70 F ± 15 F. All cylinders must be tested in a horizontal orientation. SFI Specification 17.1 Page 4 Effective: February 26, 2014

5.1 SYSTEM AND AGENT PERFORMANCE Each of the components parts (5 lbs. cylinder, two {2} nozzles, actuating system and metal connecting tubes) shall remain operational after being subjected to propane flames from a torch for 15 seconds. Operational shall be defined as discharging 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles) in a minimum of 10 seconds, 60 seconds maximum. 3.0 Feet Minimum Test Pan Extinguisher Cylinder(s) Support Leg Figure 1 Test Set Up SFI Specification 17.1 Page 5 Effective: February 26, 2014

5.1.2 APPARATUS A. The test pan shall be 19 x 19 x 5. The fuel to be tested shall be 24 ounces of racing gasoline. B. The stationary nozzle location shall be arranged as illustrated in Figure 2 below. 19.0 SFI Specification 17.1 Page 6 Effective: February 26, 2014

5.1.3 PROCEDURE A. Record the actual weight of agent (cylinder weight minus tare weight) B. Place the selected fuel in the pan. C. Ignite 24 ounces of racing fuel and allow to burn for 20 seconds. D. Trigger the actuation mechanism. E. Record the items listed (after preburn) a. Record the time it takes to completely extinguish the pan fire in seconds. b. Time to discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles). 5.2 SIMULATED VEHICLE FIRE EXTINGUISHMENT PERFORMANCE 5.2.1 SAMPLES The test pan shall be 19 x 19 x 5. The fuel to be tested shall be racing gasoline. The system to be tested shall include one 5-lbs. cylinder with two (2) nozzles for the Rear Engine Configuration and one 10-lbs. cylinder with four (4) nozzles for the Front Engine Configuration. Other components to be tested shall be as specified by the manufacturer including size and type of nozzles, all mounting and connecting hardware and actuating mechanism(s). Both testing procedures 5.2.3.1 and 5.2.3.2 are required. SFI Specification 17.1 Page 7 Effective: February 26, 2014

5.2.2 APPARATUS 5.2.2.1 ENGINE BOX SIMULATOR Simulated engine box as illustrated in Figure 3 below. Figure 3 Simulated Engine Box Material:.090 Mild Steel Minimum Volume = 2.21 ft 3 SFI Specification 17.1 Page 8 Effective: February 26, 2014

5.2.2.2 RACE CAR BODY SIMULATOR Simulated race car body as illustrated in Figure 4 below. Material:.090 Mild Steel Minimum Volume = 77.1 ft 3 SFI Specification 17.1 Page 9 Effective: February 26, 2014

5.2.2.3 RACE CAR CHASSIS SIMULATOR Simulated race car chassis as illustrated in Figure 5 below. Simulated Fire Wall Front for Rear Engine Configuration Simulated Engine Box 10 to 14 48 to 52 18 to 20 48 to 52 Front for Front Engine Configuration 12 to 14 110 to 120 Figure 5 Front & Rear Engine Chassis Simulator 5.2.3 PROCEDURES Sequence of testing procedures A through E may be altered if desired by manufacturer but must all be included before ignition. 5.2.3.1 FRONT ENGINE RACE CAR A. Place the Engine Box (Figure 3) on the Chassis (Figure 5). B. Attach the extinguisher system to the test fixture. C. Install the Body (Figure 4) over the Engine Box and onto the Chassis in proper front engine configuration. SFI Specification 17.1 Page 10 Effective: February 26, 2014

D. Center the pan under the Engine Box. E. Place 24 ounces of racing fuel in the pan. F. Ignite the fuel and allow to burn for 20 seconds. Activate two (2) fans of 1,150 cfm each from a distance of 10 feet and spaced 22 inches apart. G. Trigger the actuation mechanism. H. Record the items listed (after preburn) a. Record the time it takes to completely extinguish the fire in seconds. b. Time to discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles). 5.2.3.2 REAR ENGINE RACE CAR A. Attach the extinguisher system to the test fixture. B. Install the Body (Figure 4) onto the Chassis in proper rear engine configuration. C. Center the pan under the Body. D. Place 24 ounces of racing fuel in the pan. E. Ignite the fuel and allow to burn for 20 seconds. Activate two (2) fans of 1,150 cfm each from a distance of 10 feet and spaced 22 inches apart. F. Trigger the actuation mechanism. G. Record the items listed (after preburn) a. Record the time it takes to completely extinguish the fire in seconds. b. Time to discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles). SFI Specification 17.1 Page 11 Effective: February 26, 2014

5.3 AUTOMATIC THERMOSTAT ACTUATOR PERFORMANCE 5.3.1 SAMPLES The test pan shall be 19" x 19 x 5". The fuel to be tested shall be racing gasoline. The system to be tested shall include one 10-lbs. cylinder and one automatic thermostat device for each testing procedure. Other components to be tested shall be as specified by the manufacturer including size and type of device, all mounting and connecting hardware and actuating mechanism(s). Both testing procedures 5.3.3.1 and 5.3.3.2 are required to be performed. When installed on the test fixture, the automatic thermostat device shall be located within 2 inches of the rear firewall. SFI Specification 17.1 Page 12 Effective: February 26, 2014

5.3.2 APPARATUS 5.3.2.1 RACE CAR BODY REAR AREA SIMULATOR Simulated race car body as illustrated in Figure 6 below. Figure 6 Race Car Body Simulator (Trunk Area) Hinge for Trunk Lid (Lid is 25" x 44") 17" 19" 37" SIDE VIEW (Forward) 44" FRONT END VIEW Test Unit Fire Wall Simulated Chassis Frame Hinge for Trunk Lid (Lid is 25" x 44") Package Tray Insert 20" x 20" opening TOP VIEW 44" SFI Specification 17.1 Page 13 Effective: February 26, 2014

5.3.3 PROCEDURES Sequence of testing procedures A through D may be altered if desired by manufacturer but must all be included before ignition. 5.3.3.1 OPEN TRUNK LID CONFIGURATION A. Attach the extinguisher system to the test fixture. B. Install the Race Car Body Rear Simulator (Figure 6) on the Engine Chassis (Figure 7 below shows new location) with the trunk lid in the open position and side windows closed. C. Center the pan in the proper location (Figure 7). D. Place 24 ounces of racing fuel in the pan. E. Ignite the fuel. Activate two (2) fans of 1,150 cfm each from a distance of 10 feet and spaced 22 inches apart. F. Record the items listed: a. Response time for automatic activation of agent. b. Record the time it takes to completely extinguish the fire in seconds. c. Time to discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzle). SFI Specification 17.1 Page 14 Effective: February 26, 2014

Race Car Body Simulator (Trunk Area) Package Tray (20" wide) Simulated Fire Wall Figure 7 Race Car Body Simulator (Trunk Area) Modified Position on Chassis Frame Simulator Thermostat (Within 2 of Fire Wall) FRONT 12" 10" REAR 20" x 20" Pan 3" (new location for thermostat test) 5.3.3.2 CLOSED TRUNK LID CONFIGURATION A. Attach the extinguisher system to the test fixture. B. Install the Race Car Body Rear Simulator (Figure 6) on the Engine Chassis (Figure 7 below shows new location) with the trunk lid in the closed position and windows vented. C. Center the pan in the proper location (Figure 7). D. Place 24 ounces of racing fuel in the pan. E. Ignite the fuel. Activate two (2) fans of 1,150 cfm each from a distance of 10 feet and spaced 22 inches apart. F. Record the items listed: a. Response time for automatic activation of agent. b. Record the time it takes to completely extinguish the fire in seconds. c. Time to discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzle). SFI Specification 17.1 Page 15 Effective: February 26, 2014

6.0 PROOF OF COMPLIANCE On Board Fire Suppression System manufacturers are required to provide the following information to enroll in this program: 6.1 TEST RESULTS Test results shall be documented in a test report. 7.0 TEST REPORTS 6.1.1 SYSTEM PERFORMANCE The system shall extinguish the test fire in 10 seconds and shall discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles) in the required time with no re-ignition. 6.1.2 SIMULATED VEHICLE (FRONT AND REAR ENGINE) The system shall extinguish the test fire in 10 seconds or less for rear engine car configurations and 20 seconds or less for front engine car configurations with no re-ignition. 6.1.3 AUTOMATIC THERMOSTAT ACTUATOR PERFORMANCE (OPEN AND CLOSED TRUNK CONFIGURATION) The automatic thermostat actuator shall activate the system within 15 seconds maximum. The system shall extinguish the test fire in 10 seconds and shall discharge 95% of the suppression agent in the cylinder (when liquid agent ceases to exit the nozzles) in 10 seconds minimum, 60 seconds maximum with no re-ignition. A separate test report, or set of test reports if required, shall be submitted for each product model. If more than one test facility is required to complete all necessary tests, then a separate test report shall be submitted from each one. A test report shall be submitted for each component, if tested separately. The test facility shall assign a unique number to each test report. This number along with the report date and page number shall appear on each page. Each test report shall include: 7.1 RELEVANT INFORMATION 7.1.1 Manufacturer's name, contact name, address and telephone number. SFI Specification 17.1 Page 16 Effective: February 26, 2014

7.2 TESTS 7.1.2 Name, address and telephone number of the test facility. 7.1.3 Name and signature of the responsible test supervisor. 7.1.4 Actual date of the test. 7.1.5 Specification number and effective date. 7.1.6 Product name, description and model designation. Including: A. Maximum/Minimum operating temperatures B. Valid MSDS 7.1.7 Component name and description. Each test conducted shall be listed showing the test name, apparatus used, procedure used and test results obtained along with any other appropriate information. 7.3 AUTHENTICATION Test reports shall be authenticated and stamped by a Professional Engineer who is registered in the state in which the testing is conducted. If necessary, SFI may allow an equivalent entity to provide authentication. 8.0 INITIAL DESIGN VALIDATION To receive initial recognition from SFI as a participant in the SFI Specification 17.1 Program, the manufacturer must submit to SFI all information delineated in the Proof of Compliance section. This information shall be provided for each On Board Fire Suppression System model offered by the applicant that is to be included in the program. Any change in design, materials and/or methods of manufacturing not specifically excluded is considered a model change and, therefore, requires initial design validation. 9.0 PERIODIC REVALIDATION Test reports with successful test results must be submitted to SFI at least once every 48 month period following the date of the initial design validation test for each model of On Board Fire Suppression System manufactured by the participant. If multiple test reports are required to obtain all test results, then the earliest test date shall be used to determine when the periodic revalidation reports are due. SFI Specification 17.1 Page 17 Effective: February 26, 2014

10.0 CERTIFICATION OF COMPLIANCE Upon demonstration of successful compliance with all the requirements of the specification and the self-certification program and upon entering the licensing agreement with SFI, the manufacturer may advertise, present and offer the On Board Fire Suppression Systems for sale with the representation that their product meets the SFI Specification 17.1. Continuing certification is contingent upon the following additional considerations: (1) the product shall be resubmitted for testing following any change in design, materials and/or methods of manufacturing not specifically excluded, and (2) periodic revalidation test reports are submitted when due to SFI. 11.0 CONFORMANCE LABELS The conformance label is a sticker. A sticker shall be placed on each of the cylinders in the system. The serial number of the sticker should appear on the customer invoice to aid in identification and tracking. 12.0 DECERTIFICATION Participating manufacturers are subject to decertification when not in compliance with the requirements of this program or when their products are not in compliance with the requirements of this specification. Decertification will provide SFI the right to effect any and all remedies which are available to SFI in the licensing agreement. 13.0 APPEAL PROCEDURE In the event of decertification, the manufacturer is entitled to an appeal of the decision of SFI. Requests for appeal must be received by SFI no later than thirty days following receipt of the notice of decertification. Appeals of such decisions will be heard at the next meeting of the Board of Directors of SFI. 14.0 STATEMENT OF LIMITATIONS Testing procedures and/or standards contained in this specification are intended for use only as a guide in determining compliance with the minimum performance requirements as defined herein. The granting and assignment of the "This Manufacturer Certifies That This Product Meets SFI Specification 17.1" logo/designation is in no way an endorsement or certification of product performance or reliability by SFI. SFI, its officers, directors and/or members assume no responsibility, legal or otherwise, for failure or malfunctions of a product under this program. SFI Specification 17.1 Page 18 Effective: February 26, 2014

15.0 COSTS All costs involved in this program will be absorbed by the submitting manufacturer. 16.0 COMPLIANCE PERIOD As this specification is revised to reflect changes in technology and/or field conditions, to remain current, participating manufacturers in the SFI Specification 17.1, On Board Fire Suppression Systems, Program, must demonstrate full compliance with the requirements of this specification within ninety (90) days of the latest effective date. * Original Issue: May 9, 1989 Reviewed: December 13, 1993 Revised: August 13, 2002 Revised: March 23, 2004 Edited: August 18, 2004 Revised: February 9, 2006 Revised: October 11, 2006 Revised: February 18, 2008 Edited: August 27, 2009 Reviewed: December 11, 2009 Revised: November 18, 2010 Reviewed: December 2, 2011 Edited: July 25, 2013 Reviewed: December 14, 2013 Revised: February 26, 2014 Reviewed: December 11, 2015 SFI Specification 17.1 Page 19 Effective: February 26, 2014