NES. What s New June Contents: Detailed Technical guidance. Work section updates. (key points)

Similar documents
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Assessment Schedule - TS8

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Refrigeration Technology in Building Services Engineering

(Notices) EUROPEAN COMMISSION

Operating Performance

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

Assessment Schedule - TS.6

Page 1 of Relevant Provincial Jurisdictional legislation.

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

MECHANICAL SERVICES 101. Ian White

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

2013 ASHRAE. Standards & Guidelines CD. Contents

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

Government Gazette Staatskoerant

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Air Conditioning Inspections for Buildings Condensers

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

2. CURRICULUM. Sl. No.

Use of energy recovery systems in air conditioning, ventilation or screening

Energy Efficiency Considerations in Refrigeration Systems

IEC PROJETOS EM VOTAÇÃO. IEC 62256/Ed2: Hydraulic turbines, storage pumps and pump-turbines - Rehabilitation and performance improvement.

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

DIVISION 15 MECHANICAL

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

DOCUMENT TABLE OF CONTENTS

Zeroth Energy System. Presenter. Date

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

PANEL. Cableflow International Limited

AHRI Product Section and Subsection Scopes

Vydané medzinárodné normy a iné publikácie IEC za obdobie od do

SECTION AIR COOLED WATER CHILLERS

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Summary Comparison of Simulation Program Features

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Requirements for Electrical Installations

IEC PROJETOS EM VOTAÇÃO. IEC Ed.4: Railway applications - Traction transformers and inductors on board rolling stock

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

1.2 REFERENCES - comply with the following codes and standards:

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Mauritian Standards/Amendments Published in 2013

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Energy Management and Controls

Leadership, Innovation, Advanced Technology Synergise Here!

LZT High efficiency air to water heat pumps with E.V.I. compressors

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

LZA High efficiency air to water heat pumps with HP compressor

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

MODEL ENGINEERING SPECIFICATION

Air Handling Units. Real HVACR people who understand your needs.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

SECTION ROTARY-SCREW WATER CHILLERS

Chilled Water system

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Small Applications with Ammonia

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

New Features. IES Virtual Environment 6.4

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Appendix 13. Categories of Cooling and Heating systems

UNIFORM MECHANICAL CODE

Kenya s Official Distributor of GutterFlow Products

maximise the sun s energy with warmflow solar Warmflow Solar

INTERNATIONAL STANDARD

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20

An introduction to Part L insulating pipes and ducts

Energy-Efficiency Measures List

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

INTERNATIONAL STANDARD

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

DIRECTIVE 98/34/EC REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC.

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Transcription:

Contents: Section 1. Section 2. Section 3. Section 4 SUMMARY DETAIL OF WORK SECTION UPDATES & AUDITS SCHEDULES DETAIL CHANGES TO REFERENCE DOCUMENTS A full record of the content revisions can be obtained within the report that is produced when you run the update routine on your user specifications. Detailed PDF Guidance documents can now be found by clicking on the Sustainability or Technical Design Guides icons in the Guidance toolbar. Unless stated otherwise, section or clause guidance is accessed via the right h window. Section 1 Detailed Technical guidance Summary New guidance covering: o Chiller testing, refrigerants, F-Gases / leak detection, IOR codes of practice evaporative cooling (T60). o New technical design guide to HV LV earthing bonding (W56) clause guidance for HV/LV earthing (W51). o Electric trace heating (Y24, S12, T69, T32). o Water treatment of closed heating/cooling systems ref BSRIA BG50/2013 (Y25, T32, T69). o Pre-insulated underground pipelines (Y10 T32, T69). o Fire smoke dampers (Y30, U39, U19, T41). o Factory built custom built solar heating systems (T15). o Fume cupboard types (U15). See section 2 for details Work section updates (key points) Stards Regulations updates (only significant stards listed here) Page 1 of 8 T60 clauses guidance significantly enhanced including additional options for central plant (e.g. free cooling chillers, simultaneous heating/cooling units, hybrid adiabatic coolers Turbocor type chillers). Addition of new section W56 HV Earthing Bonding with significantly enhanced clauses content within the newly titled W51 LV Earthing Bonding, EMC Measures Surge Protection. Clauses, schedule guidance added for pre-insulated underground pipelines (Part 2, Y10, T32, T69). Clauses added for onsite testing commissioning of fume cupboards (U15). Fire damper smoke control damper clauses modified to include appropriate stards (Part 2, Y30, U39, U19, T41). Pump circulator clauses updated with ecodesign associated with EC Regulations (Part 2, Y20,, S12, T32, T69). Water treatment of closed heating cooling systems clauses guidance amended to reflect new stards/practices (Part 2, Y25, T32, T69). Clauses updated to better reflect trace heating of HWS (Part 2, Y24, S12, T32, T69). 10 new schedules created in-line with industry feedback audits. See section 2 for further details section 3 for schedules Some significant documents covered by the update include: o Part L 2013. o HSG274 Part 1 the 4 th edition of ACOP L8:2013. o BSRIA BG 50/2013 European BPR 528/2012. o EC Regulation amendment 622/2012. o B&ES DW 145 ASFP Grey Book, volume 1. See section 4 for details of all changes to British Stards other reference documents

Section 2 Detail of work section updates audits Central Refrigeration Plant T60 New schedules for: o T60 Air cooled chillers. o T60 Water cooled chillers. o T60 Dry air coolers. o T60 Hybrid dry adiabatic evaporative coolers. o T60 Cooling towers. o T60 Chilled water storage vessels. The following additions have been made to options for central plant: o Magnetic bearing ( Turbocor ) type chillers (new clause). o Simultaneous heating/cooling 4-pipe heat pump/chiller (new clause). o Free cooling type air cooled chillers (new clause). o Heat recovery type chillers added (desuperheater recuperator type) clause option on screw scroll type air cooled chiller clauses. o Hybrid dry adiabatic evaporative coolers (new clause - types included: spray nozzle, spray onto mesh trickle onto media types with once through water recirculation options). o Mesh/spray type adiabatic cooling system add-on for air cooled plant (new clause). o Plume abatement type cooling towers option on existing clauses. o Types of closed circuit cooling towers added to existing clause. o Hydronic kit option (buffer tank, circulation pump pressurisation unit) for packaged air cooled chillers option on existing clauses. o Ammonia type air cooled chillers (new clauses). Clauses added for Installation roles responsibilities, site performance testing commissioning, Refrigerant leak detection. Additional regulation added references the Institute of Refrigeration (IOR) British Refrigeration Association (BRA) Codes of Practice added to various clauses. Section guidance amended regarding refrigerants Part L 2013. Existing clauses significantly amended. LV HV Earthing Bonding W51 W56 New Technical Design Guide, LV HV Earthing Bonding briefly describes the design flow process of earthing design for both LV HV systems. Section W51 has been renamed LV Earthing Bonding, EMC Measures Surge Protection, with clause content enhanced. The section guidance for Section W51 is now exped to provide more information. New section W56 HV Earthing Bonding refers to key stards such as BS EN 50522:2010, BS EN 61936-1:2010 BS 7430 to aid safe design for HV earthing bonding systems. The new section is accompanied with section guidance. Pre-insulated Pipework Y10, T32 T69 New Part 2 clause 210.062 new Y clauses Y10 2880 2882 added to cover bonded steel flexible metal, plastic multi-layer pipes systems. New clauses added to self-contained specifications T32 (Low Temperature Hot Water Heating) T69 (Chilled Water) for pre-insulated underground pipelines. New schedule Y10 Pre-insulated pipework added. Page 2 of 8

Section 2 Detail of work section updates audits Fume Cupboards U15 New clauses 310.020 310.022 added for onsite testing commissioning of fume cupboards Guidance on fume cupboard types as BS EN 14175 added to various clauses. Ductwork Regulating Fire Dampers Y30, U39, U19 T41 Aerodynamic testing stard BS EN 1751 for dampers added to various clauses. Fire damper smoke control damper clauses modified to include appropriate stards, including BS EN 15650, BS ISO 10294-4, B&ES DW 145. Guidance regarding B&ES DW 145 ASFP Grey Book, volume 1, on fire dampers added to various clauses. Glless Circulators Y20, Y22,, T31 T69 Content added to clauses regarding ecodesign associated with EC Regulation 641/2009 amendment 622/2012 for glless circulators EC Regulation 547/2012 on gled centrifugal water pumps. Relevant parts of BS EN 16297 added to clauses for calculating the energy efficiency index (EEI) of both stalone circulators circulators integrated into products such as boilers heat interface units. Clauses in self-contained specifications aligned with pump clauses in Y20. Water Treatment of Closed Heating Cooling Systems Y25, T31 T69 New guidance on BSRIA BG50/2013 Water Treatment for Closed Heating Cooling Systems added to section guidance various clauses. Guidance added to Y25 2050 clauses regarding fill water pre-treatment. Various Y25 reference clauses amended to reflect new BSRIA BG50 European Biocidal Products Regulation 528/2012 (BPR). Guidance added to clause Y25 2050 on the need for fill water pre-treatment in closed systems. New part 2 clause 225.065 added for corrosion coupon racks. References to HSG 274 Part 1- The control of legionella bacteria in evaporative cooling, added to various clauses. Trace Heating Y24, S12, T32 T69 Various Part 2 clauses Y reference clauses generally updated to reflect stards BS EN 62395, BS EN 60519 BS EN 60079. Clauses updated to better reflect trace heating of HWS for temperature maintenance thermal disinfection control. New schedule Y24-Trace heating added. Solar Collectors T15 Clauses guidance updated to reflect current stards including BS EN 12976, BS EN 12977:2012 BS EN ISO 9806:2013 to enable either a factory made or custom built solar heating system to be specified. HV/LV cables wiring Y61 Two new schedules added to clause 261.010. Cable schedule Y61-Cables technical details by application is for specifying the required cable type for each application, Y61-Main Sub-main cables design data is where all circuit details, cable design/size data, routing other information should be specified. Page 3 of 8

Section 3 Schedules Below is a summary of the new schedules that can be activated by clicking on the links from NES clauses. Some guidance has been incorporated into many of the schedules in the form of comments that are displayed when hovering over certain cells. Legend Form Front sheet Lscape, secondary sheets Portrait Type (L/P) New Lscape single sheet (L) Enhanced / Portrait (P) Updated N U Section Schedule Name Form Type Notes T60 Air cooled chillers P N T60 Water cooled chillers P N T60 Chilled water storage vessels P N T60 Cooling towers P N T60 Dry air coolers P N T60 Hybrid dry adiabatic evaporative coolers Y10 Pre-insulated pipework P N P N Could be used for the following types: Air cooled external. Air cooled ducted internal. Free cooling. Heat recovery (with desuperheater or recuperator). DX with remote air cooled condenser. Could be used for the following types: Scroll. Screw. Magnetic bearing ( Turbocor ). Reciprocating or centrifugal types. Covers either: Buffer vessel to minimise compressor starts or Thermal storage vessel. Covers either: Open circuit type or Closed circuit type with both plate heat exchanger tower spray pumps mounted on skid adjacent the tower or with heat exchanger internal to tower tower spray pumps mounted on skid adjacent the tower. Use for horizontal coil or V-shape or W-shape coil types. Could be used for: Dry cooler with spray nozzles. Dry cooler with deluge onto distribution channels to wet the heat exchanger (water recirculation type). Dry cooler with trickle onto media (once through type). Dry cooler with trickle onto media (water recirculation type). Covers either: Bonded steel or Bonded flexible plastic or Page 4 of 8

Section 3 Schedules Y24 Trace heating L N Y61 Y61 Cables technical details by application Main Sub-main cables design data L L N N Bonded flexible metal or Non-bonded flexible plastic systems. Enables all pipework trace heating to be specified in one place including power supplies, BMS interfaces etc. Enables the designer to specify the cable type for each application (example included within the schedule). Circuit details/routing, cable design/sizing data etc. (example included within the schedule). Page 5 of 8

Section 4 Detail changes to reference documents Work Section Reference document - Current Status of current reference Reference document - New BS 5499-4:2000 Safety signs, including fire safety signs. Code of practice for escape route signing BS 5499-4:2013 Safety signs. Code of practice for escape route signing BS EN 50083-8:2002 Cable networks for television signals, sound signals interactive services. Electromagnetic compatibility for networks BS EN 50083-8:2013 Cable networks for television signals, sound signals interactive services. Electromagnetic compatibility for networks BS EN 60081:1998+A4:2010 Doublecapped fluorescent lamps. Performance specifications Amendment 5 BS EN 60081:1998+A5:2013 Double-capped fluorescent lamps. Performance specifications BS EN 60927:2007 Auxiliaries for lamps. Starting devices (other than glow starters). Performance Amendment 1 BS EN 60927:2007+A1:2013 Auxiliaries for lamps. Starting devices (other than glow starters). Performance BS EN 161:2011+A2:2012 Automatic shut-off valves for gas burners gas appliances Amendment 3 BS EN 161:2011+A3:2013 Automatic shut-off valves for gas burners gas appliances N12 BS EN 50262:1999 Cable gls for electrical installations BS EN 203-1:2005+A1:2008 Gas heated catering equipment. General safety rules BS EN 62444:2013 Cable gls for electrical installations BS EN 203-1:2014 Gas heated catering equipment. General safety rules R12 S17 S21 S30 BS EN ISO 11297-3:2013 Plastics piping systems for renovation of underground drainage sewerage networks under pressure. Lining with close-fit pipes BS 8515:2009 Rainwater harvesting systems. Code of practice CIBSE Guide G Public Health Engineering 2 nd Edition PD 5500:2012+A2:2013 Specification for unfired fusion welded pressure vessels Corrigendum 1 Amendment 1 Superseded Corrigendum 1 BS 8515:2009+A1:2013 Rainwater harvesting systems. Code of practice CIBSE Guide G Public Health Plumbing Engineering 3 rd Edition (February 2014) Page 6 of 8

Section 4 Detail changes to reference documents S33 BS EN 14129:2004 Pressure relief valves for LPG tanks BS EN 14129:2014 LPG Equipment accessories. Pressure relief valves for LPG pressure vessels T15 BS EN 12975-2:2006 Thermal solar systems components. Solar collectors. Test methods BS EN ISO 9806:2013 Solar energy. Solar thermal collectors. Test methods T19 BS EN 10216-2:2002 Seamless steel Nonalloy alloy steel tubes with specified elevated temperature properties BS EN 10216-2:2013 Seamless steel Non-alloy alloy steel tubes with specified elevated temperature properties T50 T60 U15 V10 V11 V21 V22 W40 Page 7 of 8 BS EN 10216-5:2004 Seamless steel Stainless steel tubes BS EN 10216-1:2002 Seamless steel Technical delivery conditions BS EN 14175-2:2003 Fume cupboards. Safety performance BS EN 61427:2005 Secondary cells batteries for photovoltaic energy systems (PVES). General methods of test BS EN 60076-2:1997 Power transformers. Temperature rise BRE Digest Selecting lighting controls (DG 498 2006) BS EN 60601-1:2006 Medical electrical equipment. General for basic safety essential performance BS EN 50133-1:1997 Alarm systems. Access control systems for use in security applications. System W60 BS EN 60584-1:1993 Thermocouples. Reference tables Corrigendum 1 Revised Amendment 1 BS EN 10216-5:2013 Seamless steel Stainless steel tubes BS EN 10216-1:2013 Seamless steel Non-alloy steel tubes with specified room temperature properties BS EN 61427-1:2013 Secondary cells batteries for renewable energy storage. General methods of test. Photovoltaic off-grid application BS EN 60076-2:2011 Power transformers. Temperature rise for liquid-immersed transformers BRE Digest Selecting lighting controls (DG 498 2014) BS EN 60601-1:2006+A1:2013 Medical electrical equipment. General for basic safety essential performance BS EN 60839-11-1:2013 Alarm electronic security systems. Electronic access control systems. System components BS EN 60584-1:2013

Section 4 Detail changes to reference documents Y10 BS EN 10216-3:2002 Seamless steel Alloy fine grain steel tubes BS EN 10216-3:2013 Seamless steel Alloy fine grain steel tubes Y10 BS EN 10216-4:2002 Seamless steel Technical delivery conditions BS EN 10216-4:2013 Seamless steel Non-alloy alloy steel tubes with specified low temperature properties Y24 BS EN 62395-1:2006 Electrical resistance trace heating systems for industrial commercial applications. General testing BS EN 62395-1:2013 Electrical resistance trace heating systems for industrial commercial applications. General testing Y24 DD CLC/TS 62395-2:2010 Electrical resistance trace heating systems for industrial commercial applications. Application guide for system design, installation maintenance Electrical resistance trace heating systems for industrial commercial applications. Application guide for system design, installation maintenance Y30 BS EN 1751:1999 Ventilation for buildings. Air terminal devices. Aerodynamic testing of dampers valves BS EN 1751:2014 Ventilation for buildings. Air terminal devices. Aerodynamic testing of damper valves Y61 Y61 BS EN 61754-4:2013 Fibre optic interconnecting devices passive components. Fibre optic connector interfaces. Type SC connector family BS EN 50363-2-1:2005 Insulating, sheathing covering materials for low voltage energy cables. Crosslinked elastomeric sheathing compounds Corrigendum 1 Amendment 1 BS EN 50363-2-1:2005+A1:2011 Insulating, sheathing covering materials for low voltage energy cables. Cross-linked elastomeric sheathing compounds Z Part 2 Z Part 2 BS EN 1329-1:2000 Plastics piping systems for soil waste discharge (low high temperature) within the building structure. Unplasticized poly(vinyl chloride) (PVC-U). Specifications for pipes, fittings the system BS ISO 16422:2006 Pipes joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure. Specifications BS EN 1329-1:2014 Plastics piping systems for soil waste discharge (low high temperature) within the building structure. Unplasticized poly(vinyl chloride) (PVC-U). Specifications for pipes, fittings the system Pipes joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure. Specifications Page 8 of 8