ELECTRONIC SOUNDER STROBE Model : AVD-C407

Similar documents
L-Series, Emergency Communication Devices

L-Series, Indoor Strobes and Horn Strobes

L-Series, Indoor Strobes and Horn Strobes

Conventional Fire Detection

SELECT-A-HORN/STROBE SERIES

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

July 14, 1999 DF C-100.

Selectable Output Chimes and Chime/Strobes

Xenex Conventional Fire Detection & Alarm System

TrueAlert Notification Appliances

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

Conventional Fire Alarm System 2014 V1.2

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Opal TM AV Devices. Data Sheet. Benefits

AP200 SERIES INTELLIGENT ALARM DEVICES

X10 Mini, Midi & Maxi

FlexSQUARE Square shaped beacons

June 10, 2002 DF C S2424

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

SP40S-D. Kingfisher Company, inc. Features: Description:

Agent Release Control Panel

SAFEPATH SAFEPATH. Emergency communications system

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

The complete conventional fire warning system

s Notification Appliances

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Opal TM AV Devices. Data Sheet. Benefits

Intelligent addressable fire alarm control panel

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

EFBW series - BiWire Ultra control panel

TrueAlert Addressable Notification Appliances

Addressable Detectors & Bases

Autonomous control unit

INSTRUCTION & SERVICE MANUAL

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Addressable Fire Alarm Control Panel

SAFEPATH Mass Notification System (SPMNS)

AP200 SERIES INTELLIGENT ALARM DEVICES

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Conventional Audible Visual Range

>WIRELESS> ALARM SYSTEM CR200

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

INSTRUCTION & SERVICE MANUAL

Industries. As a premier global manufacturing company, we believe that great brands are

Field Configurable Horns and Strobes

Addressable and Conventional Fire Protection

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Potter Wall Mount Select-A-Strobe

30.45 Electric Release PDRP-2001

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

good things in small packages

AL800ULADA. NAC Power Extender. Installation Guide

Fire Signalling. Signalling Solutions

Consultant Specification AGILE Wireless Fire Detection System

TrueAlert Addressable Notification Appliances

Accessible Toilet Alarm

Addressable Loop Powered Visual Alarm Devices

Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

Conventional Smoke Detectors KFAPO

The Advance You ve Been Looking For

Half-Dome. the Design-Tower. Compact

Installation, Operating and Maintenance Manual

Specification/ Data Sheet

Life safety notification

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

INSTRUCTION MANUAL A131 High Level Audible Warning System

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

SECTION FIRE ALARM SYSTEMS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Genesis LED G1 Series

Field Configurable Horns and Strobes

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Exit Stopper. STI-6400 Series

STANDARD FEATURES SPECIFICATIONS

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

EXTINGUISHING AGENT RELEASE MODULE

Installation Instructions

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

CONVENTIONAL AUDIBLE VISUAL

PSN-1000 & PSN 1000(E) Installation Manual

Doc. No Part No Rev. U * T*

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Installation Instructions

The EN54 Part 2 & 4 Fire System

Fire Signalling. Signalling Solutions

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Transcription:

ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an audio & visual warning device. The Housing is made of red ABS plastic, and the red light diffuser of Plexiglas, with high luminance LEDs as the light source. It has a standard clip-on base & terminal for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Operating Voltage 24VDC ±10% Current Consumption Sounder Output Operating Temp. Range Relative Humidity Ingress Protection Material of Housing Light Source Colour of Body 30 ma (During Activation) 95dB at 1m Distance -10 C to +50 C 95%, No Condensation IP30 112 gram ABS Plastic High Luminance LED Red, with Clear Light Diffuser Sounder Strobe Model : AVD-C407 Position the Body and Push to clip onto to the Mounting Base Using Clip-on Mounting Base for ease of Installation Mounting Base (Secured to Wall) 89.5 mm 62 mm 89.5 mm 74 mm 10 mm 54 mm 141 mm 128.5 mm 114 mm 70 mm 14 mm 141 mm Ø4 mm Physical Dimension Mounting Base www. multron. com Version : 16-08-2016

SOUNDER STROBE Model : AVD-C408W & AVD-C408R This device is designed to complement our Fire Alarm products both technically and aesthetically as an audio & visual warning device. AVD-C408W (White) The Housing is made of red ABS plastic, with a clear light diffuser lens of Plexiglas, with high luminance LEDs as the light source. It has a standard base with cable entries for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Operating Voltage 24Vdc ±15% Sounder Current 7 ma (During Activation) Strobe Current 18 ma (During Activation) Audible Alarm Output 85db at 1m (Pulsating) Flash Rate 1.64hz (0.61 second) Operating Temp. Range -10 C to +50 C Relative Humidity 95%, No Condensing Ingress Protection IP52 190 gram Material of Housing ABS Plastic Colour AVD-C408W White Body, with Clear Lens AVD-C408R Red Body, with Red Lens Features Aesthetically pleasing AVD-C408R (Red) Long-Life, Ultra-Bright LED Light Source Easy Installation with Low Maintenance Separate Input Signal for the Sounder and Strobe Suitable for both Wall or Ceiling Mounted Designed in Compliance to BS-EN54-23 Standards 64mm 70mm 11mm Ø104mm Ø72mm TYPICAL PHYSICAL DIMENSION Mounting Holes Ø5mm x 23mm Slot 24Vdc Input Signal For Sounder 24Vdc Input Signal For Strobe + _ + _ 6 2 5 3 2 4 6 5 3 4 Base Termination :- Sounder Input Strobe Input + 2-5 + 3, 4-6 TYPICAL TERMINATION DIAGRAM info@multron.com www.multron.com Version : 08-11-2016

Door Alarm Unit AVD-DA200 Series The compact Door Alarm Units are with integrated Sounder / Strobe for monitoring of Doors or Exits which are normally meant to be closed. Once these Doors are opened, the alarm will be triggered. It may be used as a stand-alone unit, or several units may be interfaced with a Central Monitoring Panel, or Graphical Mimic Panel for easy supervision by the Security Personnel. AVD-DA200R AVD-DA200B Model Technical Specifications Operating Voltage Normal Current Consumption Alarm Current Consumption Sounder Output Flash Rate Operating Temperature Housing Material (Exclude Battery & Charger) Colour Of Strobe Red Lens Blue Lens 10 to 13.5 Vdc 20mA 420mA 110 db 90 flashes / min -25 C to 70 C UV Resistant ABS Approximately 280g Features :- Dual Tamper Protection for removal of the whole housing or cover With optional built-in 7.2V Rechargeable Battery Flashing LED to indicate operational status Loud Sounder with high luminance Strobe Light Selectable Exit Delay Timer and Alarm Duration 111 70 38 Key-Switch Sounder Tamper Switch 202 Typical Physical Dimension (All Dimension in mm) www. multron. com Version : 17-08-2015

N/O Alarm Contact Output Magnetic Contacts Input Trigger Incoming Power Supply : 13.5Vdc Tamper Switch Key-Switch Alarm Sounder Dip-Switch Typical Termination Diagram Optional 7.2Vdc Re-Chargeable Backup Battery Key-Switch If the Key-Switch is used, the alarm will only stop after the switch is turned to `off position. If the Key-Switch is not used, the alarm will stop once the door is closed. Alarm Delay Timer The Alarm Delay could be set by Dip-Switch 1 & 2. The Delay is to allow for a short time duration to enter or exit the doorway. Prolong opening of the door beyond the delay period will trigger the alarm. Time Switch 1 Switch 2 0 sec 0 0 10 secs 0 I 30 secs I 0 60 secs I I Alarm Timer The alarm activation duration could be set by Dip-Switch 3 & 4. The selectable duration could be 15 min, 3 min, 1 min, or continuously as long as the door remained open. Time Switch 3 Switch 4 15 mins 0 0 3 mins 0 I 1 min I 0 Cont I I

Horn Strobes Model SYS-HSW (Selectable Output) Features Mounting Plate included for compatibility with a wide range of back boxes 3 field selectable candela setting, 15, 75 and 115 Simple Rotary Dials for selection of Candela and Horn settings Built-in synchronization feature keeps strobe in sync for up to 30 minutes Strobes Listed to UL 1638, Horn Listed to UL 464 Horn settings on the Horn Strobe model include high and low volume, continuous or temporal 3 tone Round trim ring available for ceiling mount application Universal Fire Symbol is language independent 126mm 62.6mm Ø173mm 62.6mm 131mm Wall Mount Horn Strobe Model SYS-HSW Ceiling Mount Horn Strobe Model SYS-HSW c/w Optional Ceiling Trim Ring This line of devices features a wide variety of features that simplifies installation. The mounting plate allows the device to be compatible with a wide range of back box sizes. Settings for the strobe and horn are done using simple rotary switches at the back of the device. Synchronization is achieved without the use of additional modules; when powered with a filtered DC source, the strobe portion is capable of self-synchronization for 30 minutes as per NFPA 72 requirement. Three Candela options are available for the strobe when it works on 24 volts or full wave rectified power. High and low volume are options for the horn as well as continuous tone or temporal 3 output. Ceiling Mount Horn Strobe Model SYS-HSW c/w Optional Ceiling Trim Ring (Order Separately) Available accessories include a round trim ring to adapt the wall mount device for ceiling mount applications. Simply install the round ring over the square device for a perfect fit on the ceiling.

24Vdc Input Signal Strobe Candela Adjustment Horn Volume Adjustment Rotary Dials are provided at the back of the device for ease of adjusting the Candela & Horn www. multron. com Version : 07-04-2016

SOUNDER STROBE ADDRESSABLE SOUNDER STROBE AVD-A403 CONVENTIONAL SOUNDER STROBE AVD-C403 AVD-C403 - Conventional Sounder Strobe AVD-A403 - Addressable Sounder Strobe MULTRON range of combination Electronic Sounder with Strobe Light have been designed to complement other products in our Fire Alarm equipment range both technically and aesthetically as an audio & visual warning device. The Housing is made of red ABS plastic, and the red light diffuser of Plexiglas, with high luminance LEDs as the light source. It has a standard base with cable entries & terminal block for ease of installation and mounting. The Electronic Sounder Strobe Light is designed for a wide variety of fire, security and industrial applications where reliability, efficiency and flexibility are of prime importance. TECHNICAL SPECIFICATIONS :- Model AVD-C403 Conventional Type AVD-A403 Addressable Type Operating Voltage N.A. Loop 24V Operating Current N.A. Loop 1mA (Standby) 3mA (Alarm) Power Voltage 24 V 24V Power Current Sounder Output Operating Temperature Range Relative Humidity Dimension Material of Housing Colour 0mA (Standby) 65mA (Alarm) 85 db (Alert) 94 db (Evacuate) -10 C to +50 C 95%, No Condensation 3mA (Standby) 65mA (Alarm) Diameter 110mm x Height 97.5mm Approximately 345g ABS, with light diffuser of Plexiglas Red www.multron. com Version : 17-08-2015