Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Similar documents
Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

.005 ATMOSPHERIC DEAERATOR

DEAERATORS .005 ATMOSPHERIC DEAERATOR

Silhouette. Feedwater Heater. Boiler Feedwater

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

BuildingName The Description of the Project P DOCUMENTS

.03 ATMOSPHERIC DEAERATOR

Stainless Steel Condensate Return Units

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

100 years of boiler technology leadership.

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Open System Condensate receiver tank of cylindrical. design type SDR A with highpressure

Deaerator. Specifications

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Series 300 VTB. Installation Instructions

CHAPTER 3 BASIC STEAM CYCLE

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

Deaerators for Industrial Applications

Installation, Operation, and Maintenance. For. Stickle Series AIV Spray-Tray Type Deaerating Feedwater Heaters. Introduction

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Water Fuel + Air for combustion Blowdown

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

SECTION HEATING BOILER FEEDWATER EQUIPMENT

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

BOILER HOUSE PRODUCTS GMS

Condensate Recovery and Return System SDR A

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Electrode Boilers Model CEJS Steam

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Water Piping and Pumps

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Installation and Operating Service Manual

Instruction Manual STR MODEL RESISTO-FLO ELECTRIC BOILER

Design and Construction Standards SECTION PLUMBING EQUIPMENT

A M E M B E R O F T H E K E N D A L L G R O U P

Steam Systems 101. Understanding Your Energy Systems Better. May 5, 2016

Company History. The Deaerating Principle. Undeaerated Water Non-Condensibles (Vented) Steam Deaerated Water

Commercial 1 Track. Unit #2: Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

Fuel-Fired Vertical Tubeless Boilers

BASIL 6000 TUNNEL CAGE WASHER

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Liquid Drainers LIQUID DRAINERS

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

VENTLESS DOOR-TYPE DISHWASHER

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

In-Line Air Separators

Product overview. the optimum components for every application

Mission Critical. Fuel Supply Systems

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Condensate Boiler Feed Water Make-Up

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Standard Features. Performance/Capacities

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

GESTRA. Product Overview. The optimum components for every application

Diocese of Cleveland Facilities Services Corporation

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Clean Steam Generators

GESTRA. Product Overview. The optimum components for every application

SECTION BOILER PLANT MECHANICAL EQUIPMENT

TECHNICAL. Series 18. Pump Packages

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

The Experts in Vacuum Solutions

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

How to Trap: Process Air Heaters

SECTION PLUMBING EQUIPMENT

SECTION Boiler Controls & Waste Heat Recovery

UNIVERSAL STYLE STEAM TRAPS WU450 Series

SECTION STEAM CONDENSATE PUMPS

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Pump & Trap Combinations

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

How to Trap: Rotating Dryers Requiring Syphon Drainage

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Hoffman Specialty Pump Products

Acrison. Model 515 Polyelectrolyte Preparation Module. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

STEAM AND TRAP FUNDAMENTALS

The. Steam TWO-PIPE STEAM & PUMPED RETURN

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Installation and Testing of Inverted Bucket Steam Traps Manual

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

HEAT EXCHANGER FORMULAS & EXAMPLE

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Commercial Semi-Instantaneous Water Heaters

Transcription:

Spray Flow II.00 cc/liter Atmospheric Deaerator Pressurized and Atmospheric Deaerators CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.00 cc/liter from 0% to 100% of deaerator capacity. industrialsteam.com

Spray Flow II Atmospheric.00 cc/liter When to use 100% Makeup 0% condensate Yes 0% Makeup 70% condensate High Pressure condensate returns 100% Turndown Load Swings Yes Yes FEATURES CONSTANT RECYCLING guarantees deaeration of all dissolved oxygen in excess of.00 cc/liter from 0% to 100% of deaerator capacity. UNIQUE FULL PARTITION DESIGN accepts gravity returns to the atmospheric scrubbing section along with make-up and pumped returns. Deaerating section accepts trapped returns for preferential use of flash steam. ELECTRONIC INSTRUMENTATION FOR MODULATING LEVEL CONTROL includes a HART compatible differential pressure transmitter, PID controller, and motorized control valve. SEPARATE DEAERATING & MIXING SECTIONS offer a two stage continuous cycle which provides.00 cc/l deaerated water during all load conditions regardless of surges from the system. ONLY STAINLESS STEEL components come in contact with undeaerated water. ATMOSPHERIC NON-CODE VESSEL require no annual shutdown for inspection. CUSTOM ENGINEERED PACKAGED SYSTEM includes boiler feedwater pumps and quality components to insure reliable service. Testing Requirements This system requires steady state conditions per the ABMA testing procedure.

ADVANTAGES Industrial Steam s exclusive constant recycling feature and the use of a partitioned receiver provide the advantages of a two-tank system as a single package. These advantages are available without the necessity for onsite erection or field installed piping. Expanded deaerating sections are standard for surge condensate loads. GUARANTEED PERFORMANCE FROM 0% to 100% of capacity regardless of load conditions is unmatched by any other deaerator. CUSTOM ENGINEERED PACKAGED SYSTEM results in a small foot print, minimal onsite installation costs, and a single source of responsibility for all major components. OPERATION Modulated make-up water is sprayed through a stainless steel spring loaded nozzle into a stainless steel internal vent condenser located in the scrubbing section. The nozzle produces a thin conical sheet of water which condenses the vapors while permitting oxygen to exit through the unrestricted atmospheric vent. Pumped low temperature returns are also sprayed through the nozzle. Gravity returns flow unrestricted to the scrubbing section. The combined make-up and returns in the scrubbing section are heated with steam and recycled deaerated water from the deaerating section. Both the steam and deaerated water enter the scrubbing section through separate stainless steel manifolds. The perforated steam manifold provides jets of steam to vigorously scrub the major portion of the dissolved oxygen from the make-up, pumped returns, and gravity returns. The temperature in the scrubbing section is controlled at 210ºF (at sea level), which assures the release of the majority of the dissolved oxygen without flash loss. The scrubbing section water, which is nearly fully deaerated, is continuously recycled to the deaerating section where it is sprayed through stainless steel, wide-angle, full-cone nozzles. Steam enters the deaerating section in response to the temperature in the scrubbing section. Since the cycle is continuous, pure steam is always available for final deaeration. The last traces of oxygen are removed at the point of contact with the purest steam. Excess, fully deaerated water flows continuously from the deaerating section to the scrubbing section through the stainless steel recycle manifold. Trapped returns are piped to the deaerating section where the flash steam is preferentially used for final deaeration. Since the recycle pump capacity exceeds the deaerator capacity by at least 2%, the deaerator is able to meet.00 cc/l. From zero to 100% load. This same feature also enables the deaerator to supply fully deaerated water to the boiler on start-up. Rapid load changes and on-off boiler feedwater controls, which are very troublesome for other atmosphereic deaerators, will not affect the Spray Flow II's performance or operation. STEAM WATER AIR GRAVITY ATMOSPHERIC VENT MAKEUP AND PUMPED STEAM SCRUBBING MANIFOLD MANIFOLD TRAPPED STEAM IN SCRUBBING SECTION 210 F DEAERATING SECTION 21 F INLET PUMP(S) DEAERATED WATER TO BOILER

Components and Sizing 1 Make-up Controller 2 Make-up Control Valve Make-up Nozzle (Stn. Stl.) 4 Vent Condenser (Stn. Stl.) Pressure Switch 6 Spray Nozzle 7 Recycle Pump Motor 8 Recycle Pump 9 Boiler Feed Pump Motor 10 Boiler Feed Pump 11 Magnesium Anode 12 Ball Valve (Column Drain) 1 Level Transmitter 14 Coupling (Recycle Pump Discharge) 1 Coupling (Recycle Pump Suction) 16 Gate Valves (Recycle Pump Suction) 17 Ball Valves (Drain) 18 Globe Valve (Make-up Inlet) 19 Ball Valves (Make-up Inlet) 20 Y-Strainer (Make-up Inlet) 21 Thermometer w/thermowell (0 DEGREE - 00 DEGREE F) 22 Temp Control Valve 2 Control Panel (NEMA 1) 24 Ball Valve (Column Isolation) 2 Ball Valve (Discharge) 26 Check Valve (Discharge) 27 Low Water Alarm 28 High Water Alarm Switch 29 Y-Strainer (Steam Inlet) 0 Emergency By-pass Valve 1 Sight Glass Assembly 2 Coupling (BF Pump Suction) Ball Valve (BF Pump Suction) 4 Pressure Gauge w/cock (0/60in H20) Starter (Recycle Pump) 6 Low Water Cut Off Switch 7 Pressure Gauge (0-60 psig) 8 Chemical Feed Quill 9 Gate Valve (Recycle Discharge) 40 Check Valve (Recycle Discharge) 41 Pressure Gauge (0-00 psi) 42 Orifice Union 4 Sight Glass Assembly 44 Ball Valve (Vacuum Breaker Line) 4 Vacuum Breaker (Check Valve) 46 Starter (BF Pump) 47 Ball Valve (Recirc) 48 Check Valve (Recirc) 49 Orifice Union (Recirc) MODEL NUMBER RATED CAPACITY SYSTEM CAP. TO OVERFLOW PUMP APPROX OVERALL DIMENSIONS RECEIVER SIZE D&L INCHES LBS/HR HP GALS MIN. GPM HP HEIGHT* L W APPROX SHIPPING WEIGHT ** 1SPI I 2SPI I SPI I 4SPI I SPI I 6SPI I 7SPI I 8SPI I 10SPI I 12SPI I 1SPI I 18SPI I 21SPI I 24SPI I 0SPI I 6SPI I,40 6,0 10,0 1,800 17,20 20,700 24,10 27,600 4,00 41,400 1,70 62,100 72,40 82,800 100,000 12,000 100 200 00 400 00 600 7000 800 1000 1200 100 1800 2100 2400 000 600 0 x 72 0 x 96 6 x 96 6 x 96 42 x 96 42 x 96 48 x 96 48 x 96 4 x 96 4 x 120 60 x 120 60 x 144 66 x 144 66 x 168 66 x 192 72 x 192 220 2 424 424 76 76 70 70 0 110 1 1660 10 220 260 210 1.8 21 20.2 1. 16.7 1.9 1. 1.6 12.9 1.4 1.2 1 1. 1.8 12.6 12.7 10 20 0 40 4 0 70 80 100 1 170 18 200 27 1 /4 /4 /4 /4 7 1/2 7 1/2 96 96 102 102 106 106 110 110 116 116 10 84 144 144 16 16 16 204 204 42 42 48 48 4 4 60 60 66 66 72 72 84 1,600 1,800 2,000 2,000 2,620 2,620,270,270 4,010 4,0,27,00 6,770 6,0 7,40 9,00 Consult factory for systems above 00,000#/hr * Overall height includes 48" stand. ** Shipping weight does not include boiler feed pumps or any optional equipment Consult Factory for systems over 00,000 lbs./hr. Weights do not include pumps or optional equipment * Includes 48" Stand ** Includes Control Panel

Additional Industrial Products L.E.S Boilers, LLC Horizontal Boilers Vertical Boilers www.lesboilers.com Industrial Fuel Systems, LLC Mission Critical Fuel Oil Systems Pump Sets www.ifuelsys.com Atlantic Feedwater Systems, Inc Boiler Feed Systems Feedwater Steam www.boilerfeedsystems.com Wilson Engineering Boiler Blowdown Systems Blowdown Heat Recovery www.wilsonblowdown.com Have questions or need help specifying this equipment? Email: engineering@industrialsteam.com Need help with an existing system or parts? Email: techsupport@industrialsteam.com Looking for a local representative? Email: sales@industrialsteam.com Literature available for download at industrialsteam.com Pressurized and Atmospheric Deaerators Industrial Steam 140 SW 7th Street, Atlantic, Iowa 0022 TEL (712) 24-00 FAX (712) 24-440 industrialsteam.com