Similar documents
DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

GTU C 220 FUEL OIL CONDENSING BOILERS

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

After Sales Service Guide

4FLOOR-STANDING GAS CONDENSING BOILERS

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

PRODUCT CATALOGUE

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

PMC-M WALL-HUNG GAS CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS

HPI EVOLUTION ADVANCE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

C 230 ECO. Control panel. DIEMATIC-m3 (GV6) Installation and Service Manual E

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

isense Pro DIN - AD280

P5253 JS F Mertzwiller N IT /02/2013

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

INDEPENDENT DOMESTIC CALORIFIERS

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

MPX 24/28 MI Compact MPX 28/33 MI Compact CONDITIONS OF USE HOMOLOGATION. B 23 - C 13x - C 33x - C 53x - C 93x - C 83x* B 23p - B 33 - C 43x

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Heating and D.h.w. Controller RVL482 Basic Documentation

1 VICTRIX ZEUS Superior kw I features

ALEZIO EVOLUTION EASYLIFE REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Quickheat 30 weather compensated boiler control

Type summary Albatros 2

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

RVL481. Heating Controller. including d.h.w. heating

<< >> Condensing technology at the service of oil. Controlling energy to save money

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

INSTRUCTION FOR THE USER THC V E OIL BLU

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Modulating clock thermostat

SPECIFICATIONS - NIKE

VICTRIX Superior kw Export VICTRIX Superior kw X Export

PRODUCT RANGE HEAT PUMPS 2012

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Service Instructions for use by heating contractor

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Electronic Pellet Burner Controller NPBC-V3-1

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Heating Zone Control. How to apply RESOL MX controller

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

RVP310. Heating Controller. Building Technologies HVAC Products

Oil-fired condensing boiler GTU C 330. User Guide B

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

PROGRAMMABLE 7-DAY RF THERMOSTAT

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

High temperature air-to-water heat pumps

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

- Data Brochure Steam Control 279

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

prestige Control Application Supplement - ACVMax

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

RVL480. Heating Controller

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

PRELIMINARY EDITION

white blue cobalt bordeaux light oak (rovere)

PROGRAMMABLE 7-DAY THERMOSTAT

Modulens G >> >> >> Condensing in excellence mode

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

CRIMSON & CRIMSON MAX

RIELLO 40 GS/M SERIES

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

OPTIMUM APPLIED SYSTEMS,

prestige Control Application Supplement - TriMax

Control Application. Supplement - ACVMax

PROMATIC WDC Heating controllers Energy under control

Self-learning Room Temperature Controller

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Tower Green HE Hybrid

Easy-Stat. Wireless Programmable Room Thermostat Pt No

RVL470. Heating Controller. Use. Functions. Series B

G a

ENERGY TOP. Condensing boiler solutions

Transcription:

ADVANCE EASYLIFE PROJECT DIEMATIC 3 and -m 3 control panels... p. 232 DIEMATIC isystem control panel... p. 234 DIEMATIC 3 DIEMATIC VM isystem wall-hung control unit... p. 235 Room thermostats and miscellaneous... p. 237 DIEMATIC-m3 Control panel X, standard and base... p. 238 DIEMATIC isystem DIEMATIC VM isystem Control panel X

CONTROL PANELS DIEMATIC SYSTEM GENERAL The virtual brain of the boiler, piloted by a microprocessor, a DIEMATIC system control panel is factory fitted with a programmable control unit that activates the burner according to the outside temperature. As it is preprogrammed, it does not require any preliminary setting. Extremely easy to use, DIEMATIC system is used to easily modify temperatures, programs and various other parameters at any time. Very user-friendly thanks to its display unit, it interfaces clearly with the user in several languages and pilots any type of installation, from the simplest to the most sophisticated. With a particularly well integrated design, DIEMATIC system control panels give the boilers on which they are mounted a very high class esthetic. Ready for delivery, a DIEMATIC 3 or DIEMATIC isystem control panel can control a boiler circuit (working on 1-stage or modulating burner). By simply adding the DHW sensor option, it is also ready to regulate (as a priority) and program the domestic hot water production. For models equipped for DHW production the DHW sensor is provided. With the addition of 1 or 2 optional PCBs (for DIEMATIC 3) (or 1 outlet sensor and 1 optional PCBs for DIEMATIC isystem), it is possible to control 1 or 2 circuits with mixing valve. Complemented with 1 or more room temperature sensors or interactive remote controls, DIEMATIC 3 and DIEMATIC isystem are self-adaptable, i.e. they will self-adapt the heating curve of each circuit to the characteristics of the installation and to the actual heating needs without prior setting. The DIEMATIC 3 control panel offers the option of being fitted with a CDI 2 interactive remote control (for CDR 2 radio remote control) or a simplified remote control with room temperature sensor per circuit. The DIEMATIC 3 / DIEMATIC isystem control panels offer the option of being fitted with a CDI 2 interactive remote control (or CDR 2 radio remote control) or a simplified remote control with room temperature sensor per circuit. The cascade installation of 2 to 10 boilers is also possible: each additional boiler can in turn manage 2 circuits with mixing valve. Just like DIEMATIC 3, a DIEMATIC-m 3 control panel, adapted for larger capacities boiler rooms, can control a boiler circuit (working on 1-, 2 stage or modulating burner). The DIEMATIC-m 3 control panel is used as standard to control 1 direct circuit or 1 circuit with mixing valve (outlet sensor optional). Complemented by 1 or 2 optional PCBs, it can thus control up to 3 circuits with mixing valve. By adding the DHW... sensor option, it can also be used to control (as a priority) and program the domestic hot water production. As standard, DIEMATIC-m 3 is capable of controlling a cascade of up to 9 boilers fitted with a K3 control panel. Each of the boilers with K3 control panel can also control up to 3 circuits with mixing valve (PCBs optional). Complemented with one or more room temperature sensors, DIEMATIC-m 3 is self-adaptable, i.e. that, without preliminary adjustment, it will itself adapt the heating curve of each circuit to the characteristics of the installation and actual heating needs. In its basic version, DIEMATIC-m 3 is designed to communicate with one or more DIEMATIC-VM isystem wall-mounted control units, which can control 2 additional hydraulic circuits each, and/or with compatible telemonitoring systems. A summary table presenting the selection of control systems and the relevant options depending on the circuits connected is given on the pages at the end of each range of boilers. OPTIONS FOR DIEMATIC 3 AND DIEMATIC-M 3 CONTROL PANELS for all installation configuration 85Q022 Domestic hot water sensor This is used for controlling the DHW temperature as a priority and programming of domestic hot water production with an independent calorifier. It can also be used as a outlet sensor in a cascade. AD 212 100000030 (1) 8575Q036 PCB + sensor for 1 mixing valve This is used to control a mixing valve with an electromechanical or electrothermal motor. The PCB is inserted into the DIEMATIC 3 or DIEMATIC-m 3 panel connected using socket and pin connections. DIEMATIC 3 or DIEMATIC-m3 can receive 1 or 2 PCB + sensor options, enabling it to control 1 or 2 mixing valves. FM 48 85757743 FM 51 AD 284 8666Q172A CALENTA_Q0005 8575Q026 8575Q037 CDI 2 interactive remote control CDR-4 interactive radio remote control (with radio transmitter) Boiler radio transmitter (radio transmitter) These are used to override all instructions from the DIEMATIC 3 or DIEMATIC-m 3 control panel from the room in which they are installed. In addition, they enable the self-adaptability of the heating curve for the circuit concerned (one CDI 2 or CDR-4 per circuit). In the case of the CDR-4, the data are transmitted by radio waves from the place where the CDR-4 is installed to the transmitter/receiver box placed close to the boiler. Simplified remote control with room sensor This is used from the room in which it is installed to override certain instructions from the DIEMATIC 3/DIEMATIC-m 3 panel: - room temperature program and instruction override. It is also used to enable the self-adaptability of the heating curve for the circuit concerned (1 remote control per circuit). FM 51 AD 284 85757746 1000923 FM 52 85757747 232 www.dedietrich-heating.com 8575Q048 Flue gas sensor This enables the user to read the display on the flue gas temperature table and control the state of cleanliness of the heating exchange surfaces in the heating body. In the case of cascade installations, each of the boilers can be connected to a flue gas sensor. (1) For models equipped for DHW production, the DHW sensor is delivered in the package. FM 47 85757742

CONTROL PANELS DIEMATIC SYSTEM for all installation configuration 8227Q020 BUS connection cable (length 12 m) The BUS cable is used to make the connection between 2 boilers fitted with the DIEMATIC 3 or DIEMATIC-m 3 control panel in a cascade installation, as well as the connection of a DIEMATIC VM isystem control unit or a telemonitoring network transmitter. AD 134 88017851 8531Q013 Set of 2 sensors for storage tank Includes 1 DHW sensor and 1 heating sensor for managing a storage tank with a boiler fitted with a DIEMATIC 3 control panel - For all the boilers equipped DIEMATIC 3 or DIEMATIC-m3 control panel, except Elidens DTG 130-45 to 115 - Elidens DTG 130-45 to 115 AD 160 AD 216 88017887 100005130 8666Q172A 8575Q034 Radio outside temperature sensor Boiler radio module (radio transmitter) The radio outside temperature sensor can be delivered as optional equipment for systems in which the installation of the wire connection outside temp. sensor delivered with DIEMATIC 3 and DIEMATIC-m 3 control panels would be too complex. If this sensor is used: - With a wire connection remote control (FM 51 or FM 52), it is necessary to order the Boiler radio module as well - With a radio remote control (AD 284), ordering the Boiler radio module is not necessary. 100013306 for GT 220 only : GT220_Q0001 2-stage/mod./3WV PCB This PCB is used to control a GT 220 D boiler fitted with a 2-stage or modulating burner. It also includes control and programming of a circuit with a 3-way mixing valve; the outlet sensor downstream of the valve (package AD 199) must be ordered separately, however. AD 217 100004294 GT220_Q0002 Outlet sensor downstream of the valve This sensor is required if using the 2st./mod./3WV PCB for controlling a circuit with mixing valve. AD 199 88017017 for GT 330/430/530, DTG 230/330, C 230 ECO and GTU C 330 Other accessories GT220_Q0002 GT330_F0004 8666Q174 8227Q063 Outlet sensor downstream of the valve This sensor is required to connect a circuit with mixing valve to a boiler fitted with a DIEMATIC-m 3 control panel when there is no direct circuit (without valve) Relay PCB + sensors for 1st valve circuit This package is required to connect the first circuit with mixing valve to a boiler fitted with a K3 control panel in case of a cascade installation. Room sensor A room sensor is connected to activate the comfort period start-up optimisation function from the room in which it is installed. It is also used to enable the self-adaptability of the heating curve for the circuit concerned (1 sensor per circuit). 40 m long BUS connecting cable The 40 m long armored connecting cable is intended to replace the 12 m BUS cable, (package AD 134) when these turn out to be too short. AD 199 88017017 AD 220 100004970 AD 244 100012044 DB 119 81997720 8227Q022 BUS cable extension This accessory is used to make the connection between 2 BUS cables if the 2 boilers to be connected are too far from each other. AD 139 88017858 www.dedietrich-heating.com 233

CONTROL PANELS DIEMATIC SYSTEM OPTIONS FOR DIEMATIC isystem CONTROL PANEL 85Q022 Domestic hot water sensor This is used for regulating the DHW temperature as a priority and programming of domestic hot water production with an independent calorifier. AD 212 100000030 GT220_Q0002 Outlet sensor downstream of the valve This sensor is required to connect the first circuit with mixing valve to a boiler fitted with a DIEMATIC isystem control panel. AD 199 88017017 MCA_Q0013 PCB + sensor for 1 mixing valve This is used to control a mixing valve with an electromecanichal or electrothermal motor. The PCB is inserted into the DIEMATIC isystem panel connected by pin connections. DIEMATIC isystem can receive 1 "PCB + sensor" option, enabling it to control 1 additional mixing valve. AD 249 100013304 AD 284/254 8666Q172A CALENTA_Q0005 CDI D. isystem interactive remote control CDR D. isystem interactive "radio" remote control (without radio transmitter) Radio boiler module DIEMATIC isystem (transmitter) These are used to override all instructions from the DIEMATIC isystem control panel from the room in which they are installed. In addition, they enable the selfadaptability of the heating regime for the circuit concerned (one CDI D.iSystem or CDR D.iSystem per circuit). In the case of the CDR D.iSystem, the data are transmitted by radio waves from the place where the CDR.i.System is installed to the transmitter/receiver box (package ) placed close to the boiler. AD 254 AD 284 100013309 1000923 8575Q037 Simplified remote control with room sensor This is used from the room which it is installed to override certain instructions from the DIEMATIC isystem panel : - room temperature program and instruction override. It is also used to enable the self-adaptabilty of the heating curve for the circuit concerned (1 remote control per circuit). FM 52 85757747 8666Q172A 8575Q034 MCA_Q0012 8227Q020 BUS connection cable (lenght 12 m) The BUS cable is used to make the connection between 2 boilers fitted with the DIEMATIC isystem control panel in a cascade installation, as well as the connection of a DIEMATIC VM control unit or a telemonitoring network transmitter. Sensor for storage tank Includes 1 sensor for managing a storage tank with a boiler fitted with a DIEMATIC isystem control panel. Radio outside temperature sensor Boiler radio module (radio transmitter) The radio outside temperature sensor can be delivered as optional equipment for systems in which the installation of the external wire connection sensor delivered with DIEMATIC isystem control panel would be too complex. If this sensor is used - With a wire connection remote control (AD 254 or FM 52) it is necessary to order the "Boiler radio module" - With a radio remote control (AD 284), already combined with a "boiler radio module" (), control of a second module is not necessary. AD 134 88017851 AD 250 100013305 100013306 234 www.dedietrich-heating.com

WALL-HUNG CONTROL UNIT DIEMATIC VM isystem WALL-HUNG CONTROL UNIT DIEMATIC VM isystem Control unit VM_Q0001 The VM isystem electronic control system, incorporated in a wall-mounted box, is used to manage and control two heating circuits and a DHW circuit and each of the heating circuits may be a direct circuit or a circuit with motorised 3-way mixing valve. It is possible to interlink up to 20 VM isystem control systems and thus configure numerous combinations, regardless of the type of installation: - VM isystem can be used in combination with an existing generator to control additional heating and DHW circuits. In this case, it will communicate with the generator via a BUS cable (e.g. De Dietrich boiler fitted with a DIEMATIC control panel). - VM isystem can also be used fully autonomously on its own to control heating and DHW circuits according to the outside temperature (sensor to be ordered separately package FM 46) independently of the generator. Dimensions: length: 320mm, height: 260mm, depth: 145mm DIEMATIC VM isystem AD 281 1000254 In addition, VM isystem can control a boiler via OpenTherm (outlet available on VM isystem) for a boiler equipped with an OpenTherm bus, or as "ON/OFF" via the auxiliary contact for any other generator (burner, HP, wood-fired boiler ). It can also control a boiler cascade: - Equipped with a DIEMATIC control panel - Equipped with an Opentherm BUS via an interface board (1 board per generator); VM isystem is also equipped with an auxiliary outlet which, apart from the controlling a generator in ON/OFF mode, allows control of a heating pump, a primary pump, a second DHW circuit, an alarm signal, etc. It also has a 0-10V inlet that can be configured for ON/OFF telephone control. Protection index: IP 65 Door on reversible hinge, can be locked and sealed OPTIONS FOR THE WALL-HUNG DIEMATIC VM ISYSTEM CONTROL UNIT 8575Q034 Outside temperature sensor This is used to measure the outside temperature FM 46 85757741 85Q022 Domestic hot water sensor This is used for controlling the DHW temperature as a priority and programming of domestic hot water production by a storage tank. AD 212 100000030 GT220_Q0002 Outlet sensor downstream of the valve This sensor is used for controlling the heating water outlet. AD 199 88017017 MCA_Q0012 Sensor for storage tank Includes 1 sensor for managing a storage tank with a boiler fitted with a VM isystem regulation. AD 250 100013305 AD 284/254 8666Q172A CALENTA_Q0005 CDI D. isystem interactive remote control CDR D. isystem interactive "radio" remote control (without radio transmitter) Radio boiler module DIEMATIC isystem (transmitter) These are used to override all instructions from the VM isystem regulation from the room in which they are installed. In addition, they enable the self-adaptability of the heating regime for the circuit concerned (one CDI D.iSystem or CDR D.iSystem per circuit). In the case of the CDR D.iSystem, the data are transmitted by radio waves from the place where the CDR.i.System is installed to the transmitter/receiver box (package ) placed close to the boiler. AD 254 AD 284 100013309 1000923 8575Q037 Simplified remote control with room sensor This is used from the room which it is installed to override certain instructions from the VM isystem regulation: - room temperature program and instruction override. It is also used to enable the selfadaptabilty of the heating curve for the circuit concerned (1 remote control per circuit). FM 52 85757747 8666Q172A 8575Q034 Radio outside temperature sensor Boiler radio module (radio transmitter) The radio outside temperature sensor can be delivered as optional equipment for systems in which the installation of the external wire connection sensor delivered with VM isystem regulation would be too complex. If this sensor is used - With a wire connection remote control (AD 254 or FM 52) it is necessary to order the "Boiler radio module" - With a radio remote control (AD 284), already combined with a "boiler radio module" (), control of a second module is not necessary. 100013306 www.dedietrich-heating.com 235

4 AT WALL-HUNG CONTROL UNIT DIEMATIC VM isystem OPTIONS FOR THE WALL-HUNG CONTROL UNIT DIEMATIC VM isystem Wall-mounted Open Therm/Modbus Interface box Needed to control a boiler cascade (1 board per boiler). AD 286 1000920 VM_Q0003 8801Q021 12m long BUS connecting cable This is used to link the VM isystem wall-hung control unit and the DIEMATIC control panel for the boiler. AD 134 88017851 8801Q022 1.5 m long intermodule connecting cable This is used for the interconnection of 2 VM isystem wall-hung control units. AD 124 88017836 8199Q063 40m long connecting cable This is intended to replace either the 12m or the 1 m cable when these turn out to be too short. DB 119 81997720 Example of installation BUS MCA 45 isystem 13:42 13:42 13:42 13:42 AD254 AD254 AD254 AD254 + 230V 50Hz 68 13 27 MCA_F211 DESCRIPTION PACKAGE REF. Boiler MCA 45 isystem - 100016199 Outlet sensor downstream of the valve AD 199 88017017 PCB + sensor for mixing valve AD 249 100013304 Wall-hung control unit VM isystem AD 281 1000254 2 x Outlet sensor downstream of the valve 2 x AD 199 2 x 88017017 Cable BUS leng. 12m) AD 134 88017851 Options 4 x CDI D.iSystem 4 x AD 254 4 x 100013309 Hydraulic connecting pipes HC 139 100002310 236 www.dedietrich-heating.com

SLA 2 ROOM THERMOSTATS - MISCELLANEOUS ROOM THERMOSTATS FOR VIVADENS MCR-P, ZENA WALL-HUNG BOILERS AND GT (C) 120 B, GT 220 B AND B2, GTU C 220 B2, GT 330/430/530 B3, TWINEO, ELITEC AND DTG 230/330 B3 FLOOR STANDING BOILERS WITHOUT DIEMATIC CONTROL UNIT 8801Q003 Non-programmable room thermostat This room thermostat is used to regulate the room temperature between 6 and 30 C by activating the burner. AD 140 88017859 8801Q002 Programmable room thermostat This thermostat handles the regulation and weekly programming of the heating by activating the burner and in accordance with the following 3 modes of operation: AUTOMATIC : according to programming (4 programs to choose from) automatically commutes the installation into comfort or low mode. The comfort and low temperatures can be adjusted between 5 and 30 C. PERMANENT : maintains the set temperature all the time (between 5 and 30 C). VACATION : intended for absences of long duration, maintains the desired temperature (between 5 and 30 C) for a predetermined duration (1 to 99 days). AD 137 (wire) or AD 200 (wireless) 88017855 880170 ROOM THERMOSTATS FOR VIVADENS MCR-P AND TWINEO BOILERS isense_q0004 Programmable room thermostat modulating "OpenTherm" This thermostat handles the regulation and programming of the heating and of DHW. The regulator adapts the power boiler to the needs 3 modes of operating are possible: AUTOMATIC : according the weekly programming used: for each programmed period, we can indicate the set temperature. PERMANENT : maintains the set temperature chosen for the day, night or antifreeze. VACATION : intended for absences of long duration. Allows to bring in the dates of beginning and end of the vacation as well as the desired temperature. For operation according to the outside temperature, a outside sensor (package AD 225) can be added. AD 265 (wire) or AD 266 (wireless) S101499 S101501 FM 46 AD 225 REGULATION ACCESSORIES MCR_Q0021 8575Q034 Outside sensor - for VIVADENS MCR-P - for TWINEO, NANEO EMC-M The outside sensor can be used alone or in combination with room thermostat. OTHER ROOMTHERMOSTATS FOR MCR-P, MS AND TWINEO AD 247 AD 269 AD 225 HX 31 ROOM THERMOSTATS FOR NANEO EMC-M AD 291 AD 292 MCX_Q0009 8801Q029 MS_Q0005 MCR_Q0021 isense_q0004 isense_q003 8801Q0 Programmable room thermostat These thermostats handles the regulation and weekly programming of the heating by activating the burner and in according with the differents modes of operation: "Automatic" according to programming, "Permanent" at a set temperature or "Holidays". The "wireless" version is delivered with a receiver box to be affixed to the wall close to the boiler. Outside sensor - for MCR-P - for MS The outside sensor can be used alone or in combination with room thermostat. Programmable room thermostat modulating "OpenTherm" This thermostat handles the regulation and programming of the heating and of DHW. They include adjustment parameters for the boiler NANEO : heating curve, maxi temperature boiler, fan speed The regulator adapts the power boiler to the needs. 3 modes of operating are possible: AUTOMATIC : according the weekly programming used: for each programmed period, we can indicate the set temperature. PERMANENT : maintains the set temperature chosen for the day, night or antifreeze. VACATION : intended for absences of long duration. Allows to bring in the dates of beginning and end of the vacation as well as the desired temperature. For operation according to the outside temperature, a outside sensor (package FM 46) can be added. The version "wireless" is delivered with a transmitter-receiver to be fixed to the wall near the boiler. Dip sensor with sensor tube The NTC 147 dip sensor is delivered with an IP 54 junction box and a sensor tube Ø 1/2, useful lenght under head 120 mm. AD 225 FM 46 AD 247 (wire) or AD 248 (wireless) AD 225 HX 31 AD 291 (wire) or AD 292 (wireless) 100005660 85757741 100012645 100013138 100005660 100016414 S101789 S101796 AD 2 100004781 8801Q019 Relay box To control a single phase 230 V burner with characteristics superior to the values admissible by DIEMATIC-m 3 and K3 control panels, either mechanical power > 450 W or inrush current > 16 A. BP 51 82197781 8980Q107 8980F352 SLA 2 differential control system for controlling the load pump Used to adjust the temperature of the domestic hot water in an independent tank combined with a boiler without a control system, a buffer tank with a wood-fired boiler or a solar back-up tank. EC 320 100007832 www.dedietrich-heating.com 237

CONTROL PANEL "X", "STANDARD" AND "BASE" X control panel for GT 120 and GT 220 boilers The X-control panel can be fitted to the GT 120 range (GT 124 - GT 126), GT 220 range (GT 224 to GT 228) for heating only includes the control and safety devices used to operate the installation by regulating the temperature with the boiler thermostat. Option: room temperature thermostats: see page 237. Standard control panel for GT 330/430/530 and GTU C 330 boilers This control panel is designed for central heating installations without a control system or for ones which include a control cabinet in the boiler room. It is used to control a 2-stage burner. Basic control panels Basic control panels are used to control 1 (or 2) direct circuit(s) and those of 1- (or 2-) stage burners according to the schematic. TAM1 TAM2 Burner Control panel B GT/GTU (C) 120/1200/1200 V B, GT 220/2200 B, DTG 130/1300 B Eco.NOx 1 stage As standard as standard in combination with 2 room temperature thermostats B2 GT 220 B2 GTU C 220 B2 2 stages As standard B3 GTU C 330 B3, GT 330/430/530 B3, DTG 230/330 B3 2 stages As standard 238 www.dedietrich-heating.com