ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Similar documents
ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

ACCUMULATION OF EUROPEAN CLASS

MODULEX EXT ENBLOC MODULATING BOILER

The mechatronics of EVE 05

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

1 VICTRIX ZEUS Superior kw I features

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Ideasandformsinevolution

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Flue gas condensation...

ENERGY TOP. Condensing boiler solutions

STILE BEAUTY AND TECHNOLOGY

CITY OPEN - CITY BOX from 25 to 35 kw

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

SPECIFICATIONS - NIKE

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Ciao Green Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Sirius FS. Working towards a cleaner future

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

white blue cobalt bordeaux light oak (rovere)

C Tahiti. condensing

Condensing, pre-mixed, wall-hung gas boilers with water tank

The iqe Boiler Range. Combination and System T Boilers.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Power X High Power Condensing Wall-Hung Boilers

Exclusive Green E Condensing Wall-Hung Boilers

THE PERFECT CONDENSATION

GHP AWO 38 Technical overview

VICTRIX Superior kw Export VICTRIX Superior kw X Export

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Power X High Power Condensing Wall-Hung Boilers

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

GAS ABSORPTION HEAT PUMP

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

AIREX 2S WOOD PYROLYSIS SUCKING FAN

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Floor standing boilers. RMG Mk.II RS Mk.II

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

WOLF GAS CONDENSING BOILERS COMFORTLINE

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

PCH/new Series. High performance, total flexibility

RIELLO 40 GS/M SERIES

LOW NOx MODULATING GAS BURNERS

UP TO 35 kw HE Collection

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Germany 44% Spain 9% Italy 9% France 8% Austria 7% Greece 6% Poland 2% Belgium 2% Portugal 2% Switzerland 2% Great Britain 2% Cyprus 2%

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

The guarantee on this appliance is valid for 12 months from the first day of installation.

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

ARES Tec HIGH OUTPUT MODULAR CONDENSING BOILER RANGE

Rapid. Suspended Warm Air Heater. Caring for the environment!

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Sirius WH. Working towards a cleaner future

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

4FLOOR-STANDING GAS CONDENSING BOILERS

Tower Green HE Hybrid

Seradens Super Seradens Super Plus

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Design Manual. Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups. Platform PRO

THE PERFECT CONDENSATION

HIGH OUTPUT. Skin design RANGE

MINORCA KC - KR - KRB 24

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Residential Heating Boilers

S-AF Floor Standing Condensing Boiler kW

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

FAMILY PRO SIMPLY THE BEST

AGUAdensT TM 100% commercial condensing D.H.W. commercial water heaters from 70 to 280 kw AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

Wall hung combination

Transcription:

ALKON 90

ALKON 90 MODEL max/min condensing nominal heat output conventional max/min heat input efficiency class (Directive 92/42) kw kw kw ALKON 90 24,0 93,6 21,1 87,5 22-90 Moving in the present with the future in mind A pioneer in condensing technology and innovative home heating solutions, Unical has developed the ALKON 90 boiler, which guarantees, in time, the best energetic performances and minimum fuel consumption, even in the most difficult heating applications. Natural habitat: outdoor installation A single cast heat exchanger (an exclusive Unical design) of aluminium-silicon-magnesium alloy for a 90 kw heat input, enclosed in a compact cabinet, built in corrosion-resistant steel paint, ideal for both indoor and outdoor installations, thanks to the maximum protection grade IP X5D rating. 90 kw maximum and 22 kw minimum modulating input, in order to guarantee an extraordinary adaptation to the various heat demands. Electronic controls derived from the prestigious range of Unical Modulex boilers. The ALKON 90 boiler can be installed in a cascade formation, thanks to its special I.TOTHEM modulating system. A single heating cascade controller can control 2 modular banks of 4 boilers each (720 kw). Comprehensive versatility A wide range of optional accessories are available which permit you to create a flexible combination valid for every type of heating system.

The reasons for choosing an ALKON 90 boiler Contained dimensions: Height: 130 x Width: 51 x Depth: 60 cm Innovational combustion: pre-mix multigas modulating burner with constant C0 2 emission Up to 109% efficiency on N.C.V. Low NOx emissions CLASS 5 rating (EN 483) Elevated modulating ratio: 1:4 Easy to install: compact and simple connections Standard modulating pump controlled directly by the boiler BCM (Burner Cascade Manager) interface for remote control (optional) I.TOTHEM cascade formation for a bank of up to 4 boilers (2x) IP X5D protection grade for outdoor installation Dedicated series of accessories: - Mixing headers - Additional safety devices - E8 heating controller - Acidic condensate neutralizing kit

Analysis... year guarantee Thanks to its particular technical configuration, synonymous of quality and safety, the ALKON 90 s heat exchanger is supplied with a 5 year guarantee. FLUE OUTLET DUCT Ø 100 IGNITION ELECTRODE CONDENSATE DRAIN POINT MODULATING FAN PRE-MIX AIR/GAS ANTECHAMBER CAST ALUMINIUM-SILICON- MAGNESIUM ALLOY HEAT EXCHANGER FLAME DETECTION SENSOR Discovering the ALKON 90 boiler The heat exchanger A real work of art in aluminium-siliconmagnesium alloy, weighing 35 kg, with a surface of heat transfer superior to 2 m 2 and compact dimensions (50x23x34 cm). It is characterized by its very fast water circulation circuit, designed for maximum efficiency, thanks to the hydraulic distribution which, from a central collector, converges the water flow to the external walls. It contains about 8 litres of water and is completely insulated. Thanks to these characteristics, the ALKON 90 boiler reacts rapidly to every type of user request, favoured by: The primary ring appositely dimensioned by Unical NTC temperature sensors positioned on the flow and return pipes, which by controlling the difference in temperature in real time, are able to adapt the output constantly and instantaneously. Therefore heat inertial is nonexistent, the appliance fires or stops immediately, thereby avoiding energy waste when unrequested (an inevitable phenomenon with high water content generators, obviously much more slower in responding). The burner The new modulating multigas burner (Natural gas/lpg), fitted with a two-valve one block Dungs system, is avant-garde in the field of combustion technology. Combined with the special double stainless steel metallic fibre burner, it offers you reliability, silent operation and very high combustion efficiency. Modulation The optimal modulation ratio (1:4) permits the following types of performances: Steady CO 2 equal to 9,6% on all the output range from 22-90 kw. NOx equal to 35,62 mg/kwh which classifies the ALKON 90 boiler in the 5th NOx Class. CO equal to 104,4 mg/kwh Condensate production from 1,8 kg/h to 14,5 kg/h

... point by point Standard modulating pump Maximum efficiency Drastic reduction of fuel and electricity consumption Condensate production optimization The ALKON 90 boiler incorporates an advanced microprocessor control board which is able to constantly control the data regarding the temperature difference ( T between the flow and return rate and the rated output). Thanks to this supervision, if the manometric head is not within the calculated parameters the pump adapts its flow rate immediately, thereby ensuring optimization of the condensate production and maximum efficiency, as well as a drastic reduction of electricity consumption absorbed by the pump: Modulation (%) Electrical absorption (W) 100 % 170 max 25 % 95 min MAXIMUM OUTPUT: 93,6 kw t 23 K MINIMUM OUTPUT: 24 kw t 13 K THE MODULATING PUMP ENSURES THAT THE T (REFER TO TABLE) BETWEEN THE FLOW AND RETURN IS MAINTAINED AT A HIGH LEVEL AND SUBSEQUENTLY THE BOILER WILL OPERATE IN CONDENSING MODE FOR A LONGER PERIOD. Useful efficiency (%) 110 108 106 104 102 100 98 96 94 92 90 ALKON with MODULATING PUMP 3360 1400 l/h ALKON 90 s USEFUL EFFICIENCY IN FUNCTION OF THE OUTPUT AND INTERVENTION OF THE MODULATING PUMP 97,3 101,5 106 107 108,64 108,64 93,6 90 80 70 60 50 40 30 20 Output (kw) Safety measures The standard safety measures of the ALKON 90 boiler have been increased with: a gas pressure switch: it shuts down the boiler if the gas supply pressure is lower than 14 mbar; a low water pressure switch: it shuts down the boiler in case of pressure drops; safety level sensor: it shuts down the boiler if the condensate does not drain away correctly safety valve: set at 7 bar electrical connection for additional safety devices. Moreover, for practical drainage of the appliance at the condensate drainage point and for total safety in case of maintenance, the ALKON 90 is supplied with a: 3-way valve with full opening on the flow pipe 2-way valve integrated with flow-stop on the return pipe. A close-up view of the 3-way valve

The control panel Simple to use The ALKON 90 is a versatile boiler. Particular care has been given to the flexibility of the controls. The control panel is equipped with an alphanumerical display with 6 pre-selection keys, which enable the user to view the following information: Boiler operation Boiler status; flow and return temperature; Fault diagnostic display; User s parameters Maximum temperature settings On/off central heating Parameters with access code Type of mode selected: room thermostat (on/off), remote heating control, on-off or modulating pump; Pump overrun Fan ignition speed Data readout Global flow and return temperature DHW temperature (if incorporated with a hot water cylinder) BCM board (Burner Cascade Manager) BCM control board The ALKON 90 boiler is able to reach its maximum performance when the optional accessory BCM (Burner Cascade Manager) is incorporated in the heating system. Heating demand control: it controls the modulation level and the temperature Boiler operation management Communication with PLC controlled plants Burner controller alarm reset. Emergency function in case of E8 failure Temperature increase key Reset key/fault code display DHW set key CH selection key: Stand-by/Central heating Central heating adjustment key Temperature decrease key Fault diagnostic display

ALKON s intelligent brain E8: the intelligent heating controller The application and connection of the dedicated E8 heating controller (optional), permits a decisive qualitative leap in boiler management in function of the applied loads. The E8, as well as becoming the window of dialogue with the boiler, thanks to its features, permits the complete management of the CH system, exploiting the maximum modulating output and the maximum obtainable condensation. Functions which can be activated with the E8 Self-adaption Through the elaboration of data transmitted by the room sensor, this function adjusts the boiler s ouput to the building s characteristics, ensuring a constant monitoring of the indoor temperature on the basis of the variation of the outdoor temperature, keeping in consideration the building s thermal inertia and the contribution of free heat (solar radiation, internal heat sources etc). Boiler heating Optimization The heating controller, on the basis of the timer/heating programme set by the user, once the system s characteristics have been evaluated, will activate the function for automatically bringing forward the heating ignition time so as to ensure that the set temperature is reached at the time requested by the user. Fast set temperature This is obtained by calculating the optimum ignition start-up time. This calculation can be carried out taking into consideration the outdoor temperature or the room temperature. Overheating protection The boiler s safety temperature is controlled via the pump s overrun time in order to get rid of any thermal inertia. Multiple zone control With the same heating control device you can control 2 independent circuits with different characteristics, though having ensured all the described functions, including the deep sliding temperature function. Programme setting The heating programmes can be set daily or weekly, with more than one On-Off firing times or temperature reductions during the arch of the day. Swimming pool heating function Domestic hot water production There are many programmes which control the domestic hot water production. You can choose from the maximum of comfort to the maximum fuel saving. In order to permit the storage cylinder to supply hot water rapidly, the heating controller brings the boiler s temperature to the maximum set value. Antilegion Every 20th heating start-up or once a week on Saturday at 01:00 hrs, the storage tank is heated up to 60 C. This function will eliminate any eventual pathogens which have formed in the DHW. Frost protection mode The frost protection operation mode prevents the CH system from freezing by automatically switching heating operation on. In the frost protection mode, the room temperature for all the heating circuits is set to 5 C and the storage tank sensor frost protection is activated when the temperature drops below 10 C. DHW optimization (loading pump) The DHW loading pump is switched on only if the boiler temperature exceeds by 5 C the storage tank temperature. It is deactivated when the boiler temperature drops below the storage tank temperature or if the storage tank temperature is higher than the nominal temperature. Slope offset (heating slope distance) The boiler temperature that is required for a mixed circuit is calculated by adding to the calculated temperature setting for the heating circuit temperature the heating slope distance. The heating slope distance compensates for sensor tolerances and heat loss up to the mixer. Number of burner ignitions It stabilizes the number of ignitions of each burner Burner run hours It stabilizes the run hours of each burner Valve opening time Based on the characteristics of the servomotor Integration with renewable energy sources As for example: solar systems and/or solid fuel fired boilers And more: Management of up to 15 mixed circuits controlled by the outdoor sensor (refer to accessories: BM8 digital remote control with interface for bus-can, outdoor temperature sensor for BM8) 0-10 volt signal: the great flexibility of the E8 also permits the ALKON 90 set point to be controlled by an external control signal. This will enable, having at disposal an even more complex system, to exploit all the heating control s functions. Remote controls: available in the near future via appropriate software, this function enables the reduction of system management, remote indication of boiler run, thereby avoiding unnecessary inspection visits.

Range of system components The new vision of the modern heating system is no longer satisfied with just the boiler! Therefore, Unical places at your disposal a rich catalogue of components which facilitate the system s layout and enable you to obtain the maximum result from the technology employed and the heating system design. Note: Several additional safety devices are not supplied because their setting is subject to the type of heating system installed. BOILER ALKON 90 MASTER boiler natural gas cod. 41010081 LPG cod. 41010082 Complete with: Side panels, blind flanges with bolts and nuts, single boiler top, gas feed pipings, flow and return system pipings, modulating pump. Note: It is possible to order the outdoor cover kit (code 00361529) for containing and protecting the additional safety devices kit. In this case the Cover for 2 is needed (code 00361522 incorporated with an unused flue outlet closure tap). COMPONENTS FOR EXPANDING THE ELECTRONIC CONTROLS E8 heating controller kit cod. 00361332 Composed of: Electronic heating control, outdoor sensor, mixed flow sensor, boiler sensor, DHW storage tank sensor, terminal strip E8 WAG holder for wall mounting installation cod. 00361359 Expanding module E8.1124 cod. 00361545 Additional zone control BM8 cod. 00361358 (digital timer with outdoor sensor for connection to CAN-BUS 4 wires) BCM board cod. 00361602 MIXING HEADER and additional safety devices Mixing header up to 180 kw cod. 00361499 Mixing header connection kit DN 65 cod. 00361484 Y filter DN 65 cod. 00361488 Additional safety devices pipe kit + hydraulic and gas collectors cod. 00361528 Additional safety devices kit cod. 00361316 Composed of: 3-way cock 1/2, pressure gauge R 3/8, n 2 bulb holders, 100 C H.L. thermostat, 5 bar safety max pressure switch, thermometer, shock absorber for pressure gauge. Outdoor cover kit complete with additional safety device holders cod. 00361529 Additional safety devices holder kit cod. 00361463 ACIDIC CONDENSATE NEUTRALIZER Condensate neutralizing kit NH 500 cod. 00361551 FLUE OUTLET ACCESSORIES (in aluminium) Vertical flue terminal Ø 100 cod. 00361493 Horizontal flue terminal Ø 100 cod. 00361494 Extension Ø 100 L=1000 cod. 00361495 90 elbow Ø 100 cod. 00262514 45 elbow Ø 100 cod. 00262476

Other accessories DHW STORAGE PRODUCTION CYLINDERS To complete the heating system, in the catalogue, there are different models of DHW storage and production cylinders available, with a coil heat exchanger and with solar integration (from 100 to 2000 litre capacity, and supplied with a magnesium anode) Solar integration BISER 300 BISER 500 BISER 800 BISER 1000 BISER 1500 BISER 2000 BIKOMPACT 300 SANRIS 500 SANRIS 800 SANRIS 1000 SANRIS 1500 SANRIS 2000 cod. 00262490 cod. 00262493 cod. 00262485 cod. 00262494 cod. 00262486 cod. 00262487 cod. 00262310 cod. 00262495 cod. 00262496 cod. 00262497 cod. 00262488 cod. 00262489 Integration with only boiler SANICAL SC 150 cod. 32703 SANICAL SC 200 cod. 32704 SANICAL SC 300 cod. 32705 SANICAL SC 400 cod. 32706 SANICAL SC 500 cod. 32707 SANICAL SC 600 cod. 32708 SANICAL SC 800 cod. 32709 SANICAL SC 1000 cod. 32710 From the left: SANICAL, SANRIS, BIKOMPACT, and BISER Neutralizing kit Optional acidic condensate neutralizing kit The condensate water, produced during combustion, reacts with NOx forming acidic molecules (ph value= 4,5). It could become necessary to neutralize these substances before their emission in the drainage system water. In order to respect the ecosystem Unical proposes the NH condensate neutralizer. KIT NH 500 for boiler outputs up to 500 kw (cod. 00361551). Neutralization occurs according to the principle of the passage of acidic condensate through the granular neutralizing material. The passage takes place from the bottom to the upper direction. FLOW RATE BOILER OUTPUT FLUID TEMPERATURE STAGNATION POINT HEIGHT NEUTRALIZING SUBSTANCE DURATION OF NORMAL CONDENSATE CONDENSATE/AMBIENT WATER TEMPERATURE DIMENSIONS (lengthxwidthxheight) INLET/OUTLET CONNECTION INLET/OUTLET HEIGHT l/h kw C mm C mm mm KIT NH 500 UP TO 70 UP TO 500 5-40 90 GENO - Neutralit -Hz 12 months (1500 working hours) 5-60 476x300x185 DIN 15 50/90 The NH 1000 kit is available for higher outputs

The key quality features Aluminium (AlSiMg) heat exchanger/condenser (a detail of the combustion chamber) Pre-mixed combustion system with constant CO 2 emission (modulating gas valve, modulating fan and stainless steel burner) Modulating pump for maximum condensate production The control panel can be opened to facilitate maintenance I.TOTHEM: heat module complete with primary ring, composed of additional safety devices kit and mixing header Simple installation (detailed view flange/flange) Microprocessor boiler control board E8 heating controller (optional) for complex heating plants and cascade applications with WAG holder BCM board for remote control (optional accessory)

Dimensions and technical data 1300 607 513 MODEL ALKON 90 Output MIN/MAX NOMINAL HEAT OUTPUT IN CONDENSING MODE kw 24 93,6 MIN/MAX NOMINAL HEAT OUTPUT IN STANDARD MODE kw 21,1 87,5 MIN/MAX HEAT INPUT kw 22-90 Efficiency EFFICIENCY CLASS (DIRECTIVE CEE 92/42) REQUIRED EFFICIENCY AT NOMINAL LOAD (100%) % 97,26 REQUIRED EFFICIENCY AT 30% PART LOAD % 105,2 ACTUAL EFFICIENCY AT NOMINAL LOAD (100%) IN CONDENSING MODE % 104,0 ACTUAL EFFICIENCY AT 30% PART LOAD IN CONDENSING MODE % 108,64 COMBUSTION EFFICIENCY AT NOMINAL LOAD (100%)/ PART LOAD % 98,15 / 98,31 STAND-BY LOSSES (MIN-MAX) % 0,90 Combustion CO 2 % 9,6 CO AT 0% OF O 2 (MIN) mg/kwh 21,5-104,4 NOx (VALUE ACCORDING TO EN 483) mg/kwh 35,62 MAX CONDENSATE PRODUCTION kg/h 14,54 NOx Class 5 APPLIANCE S GAS CATEGORY II2H3P Central Heating MIN/MAX OPERATING TEMP. IN CH MODE C 30 / 85 MIN/MAX PRESSURE IN CH CIRCUIT bar 0,5-8 * MIN. WATER FLOW RATE IN CH CIRCUIT T 20 C l/min 15,14 Electrical Supply MAXIMUM ABSORBED POWER W 303 ELECTRICAL SUPPLY / VOLTAGE / FREQUENCY V/Hz 230/50 ELECTRICAL PROTECTION IP X5D Weight NET WEIGHT kg 135 FRONT VIEW REAR VIEW Legend: R - Heating system return DN 80 M - Heating system flow DN 80 G - Gas inlet DN 50 Sc - Condensate siphon drain outlet Ø 32 mm (* ) Boilers approved at 8 bar. Safety valves are available on request. Note: Values measured at room temperature = 20 C

I.TOTHEM Integration and perfect compatibility ALKON 90 multiplies itself! The flexible E8 heating controller, via the e-bus connection system, permits the management, with only two wires, of up to 8 heating modules. The I.TOTHEM range of boilers with two banks of 4 boilers each, can supply a total output of up to 720 kw, for maximum flexibility of use. All approved and certified according to the relevant Standards and requirements. Rapid installation and maximum compact The ALKON 90 boiler has been designed with a modular structure. The external cover is made in steel (with non corrosive paint and a IP X5D protective level) and contains a heat exchanger, pump, and pre-fitted pipings. Installation is simplified by the rapid flange/flange assembly on both the water and gas sides. The same cover can also contain and protect the additional safety devices and an eventual primary expansion vessel. Easy to service Doors with reversible openings Control panel which can be opened for facilitating access and removing components for inspection Rapid division of the circuits and isolation of each heating module via the ball valves supplied as standard. Very high efficiency This gives us the advantage of having at disposal, where space is at a

I.TOTHEM: a bank of n 4 ALKON 90 units with a cover for outdoor installation, completed with additional safety devices. premium, high efficiency heating modules, guaranteeing: Recovery and restoration of old heating plants. Better efficiency levels thanks to the excellent modulation ratio which reduces the output in all the boilers proportionally to the load required and shuts them down in sequence. Reliable operation under every condition thanks to load matching. Custom made for the heating system The versatility of combinations which the ALKON I.TOTHEM modular system offers is practically endless. In this case you can choose an ALKON 90 as the lead boiler who, via the E8 heating controller controls the successive ALKON 90 boilers, who are also equipped with a pump. Choosing from the accessories available, the multiple formation of boilers will be constructed on the basis of the system s requirements. Each boiler can be fitted with a single flue outlet or the flue gases can be conveyed into a sole collector.

I.TOTHEM maximum output and efficiency Efficiency (%) ALKON 90 EFFICIENCY 109 108 106 104 20 30 40 50 60 70 80 90 Requested output Total efficiency 360 kw 90 kw 90 kw 90 kw 90 kw 45 kw 45 kw 45 kw 45 kw η = 104 Output (kw) Requested output180 kw Total efficiency η = 107,2 Maximum efficiency in every situation The ALKON 90 boiler has an approved efficiency which, when the load reduces, increases progressively from 104 to 109% (in condensing mode). This is possible because the heat exchanger increases its efficiency and the flue temperature decreases when the input is reduced. One of the prominent features of the E8 heating controller is to maintain the major number of ALKON 90 units, in the I.TOTHEM multiple boiler formation, firing at the lowest possible rate in order to increase the total operating efficiency. Reduced heating load As illustrated in the sequence on this page, this proportional partition of the output reduces each heating module to 22 kw. If the required load is inferior to the total minimum output of the single units (n units x 22 kw), only the ALKON 90 boilers needed to reach the requested output at the maximum efficiency level will be fired, and the other units will be shut down. Requested output 66 kw Requested output 22 kw Moreover, in order to ensure an equal daily rotation of each module, every 24 hours each unit will be fired alternately, so as to ensure that each one operates for the same number of hours. 22 kw 22 kw 22 kw OFF 22 kw OFF OFF OFF Total efficiency η = 109 Total efficiency η = 109

I.TOTHEM the configurations 9 1 5 4 6 3 1 7 8 2 9 2 2 I.TOTHEM: a bank of n 4 ALKON 90 units with a casing for outdoor installation, completed with an additional safety devices kit. 1 2 3 4 5 6 7 8 9 BASIC BOILER CONFIGURATION ALKON 90 MASTER natural gas cod. 41010081 LPG cod. 41010082 ALKON 90 combined with MASTER natural gas cod. 41010046 LPG cod. 41010048 it does not include: Side panels, blind flanges with bolts and screw nuts, single boiler top. Top for 2 * cod. 00361522 Top for 3 * cod. 00361523 Top for 4 * cod. 00361524 Top for 5 * cod. 00361525 MIXING HEADER for n 2 boilers Mixing header up to 180 kw cod. 00361499 Mixing header connection kit DN 65 cod. 00361484 Y filter DN 65 cod. 00361488 for n 3 4 boilers Mixing header up to 360 kw cod. 00361500 Mixing header connection kit DN 100 cod. 00361487 Y filter DN 100 cod. 00361489 Additional safety devices Stub pipe kit + water and gas collectors cod. 00361528 Protection and control kit for water collector cod. 00361316 Casing kit for outdoor installation complete with additional safety devices support kit cod. 00361529 Additional safety devices support kit cod. 00361463 COMPONENTS FOR EXPANSION ELECTRONIC MANAGEMENT E8 heating controller kit cod. 00361332 WAG holder kit for wall mounting installation cod. 00361359 Zone heating E8.1124 expansion kit cod. 00361545 BM8 remote control kit cod. 00361358 BCM board cod. 00361602 ACIDIC CONDENSATE NEUTRALIZERS Condensate neutralizing kit NH 500 cod. 00361551 ADDITIONAL FLUE OUTLET ACCESSORIES Vertical flue terminal Ø 100 cod. 00361493 Horizontal flue terminal Ø 100 cod. 00361494 Extension Ø 100 L=1000 cod. 00361495 90 elbow Ø 100 cod. 00262514 45 elbow Ø 100 cod. 00262476 ADDITIONAL FLUE OUTLET ACCESSORIES FOR MULTIPLE BOILER FORMATION (in pps) Flue thermostat cod. 00361451 for n 2 boilers Basic cascade kit n 2 ALKON 90 boilers Ø 160 cod. 00361339 for n 3 boilers Basic cascade kit n 2 ALKON 90 boilers Ø 160 cod. 00361339 Extension kit n 3 ALKON 90 boilers Ø 200 cod. 00361340 for n 4 boilers Basic cascade kit n 2 ALKON 90 boilers Ø 160 cod. 00361339 Extension kit n 3 ALKON 90 boilers Ø 200 cod. 00361340 Extension kit n 4 ALKON 90 boilers Ø 200 cod. 00361341 Note: Several additional safety devices are not supplied because their setting is subject to the type of heating system installed. If installing a heating system with outputs superior to 360 kw please contact our After Sales Service Department. * If the casing kit for outdoor installation complete with additional safety devices support kit (pos. 9) is installed, order the top (equipped with an unused flue outlet closure tap) considering an additional element (for example, for n 3 ALKON 90 units with the casing kit for outdoor installation complete with additional safety devices support kit, order the Top for 4) Ed. n 1-02/2007 - cod. 33795

AG S.p.A. 46033 casteldario - mantova - italy - tel. +39 0376 57001 - fax +39 0376 660556 - e-mail: info@unical-ag.com - www.unical.ag