WINDOW/WALL-TYPE ROOM AIR CONDITIONER

Similar documents
UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

ROTARY CONTROL AIR CONDITIONER

AIR CONDITIONER ELECTRONIC CONTROL

Keep Well This Manual. Read Rules for Safe Operation and Instructions Carefully. WINDOW TYPE AIR CONDITIONER USER'S MANUAL CS0094(B)

SLIDER CASEMENT AIR CONDITIONER

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ROTARY CONTROL P/N (??/99)

ELECTRONIC CONTROL AIR CONDITIONER

Use & Care. Room Air Conditioner. All about the. of your TABLE OF CONTENTS. Normal Sounds... 4 Major Appliance Limited Warranty...

Window Wall (Manual) Room Air Conditioner User Manual KWH15CMB, KWH20CMB Refrigerant R410A

THRU-THE-WALL AIR CONDITIONER

15,100 BTU -25,000 BTU AIR CONDITIONERS ELECTRONIC CONTROLS

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

FRIGIDAIRE. iihh/tiit!ii!lii!it_itl!i!iiitihtiih ii_)}iiiiiiiiiiiiiiiit_iitii_iiiiiiiiiiiit_tiii_itiiiiiiiiiiii

PORTABLE AIR CONDITIONER

OWNER'S MANUAL MODEL: OBZ-05CM. For any service needs, call

USE & CARE MANUAL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST-RESET FUNCTION

USE & CARE MANUAL READ AND SAVE THESE INSTRUCTIONS P/N A028

ACCESSORIES INCLUDED

FRIGi. i_iiiiiiiii_iiii_iiiiiii_i_iiiiiii_i_iiiiiiii_iiii_iiii!iiiii_iiiiiiiiii!iiiyiyiii_ii_iiiii_iiiiiii_i_iiiii_. Operating tnstruct!

HEAVY DUTY AIR CONDITIONER

THRU-THE-WALL ELECTRONIC CONTROL AIR CONDITIONER

THRU-THE-WALL AIR CONDITIONER USE & CARE MANUAL. Crosley READ AND SAVE THESE INSTRUCTIONS. Contents

OWNER'S MANUAL - ROOM AIR CONDITIONER MODEL: OBZ-10ESN OBZ-12ESN. For any service needs, call

WINDOW-TYPE AIR CONDITIONER

Room Air Conditioner

Window Air Conditioner 5000 BTU Unit

Room Air Conditioner User Manual KWH15CMC. Refrigerant R410A

WINDOW / WALL-TYPE ROOM AIR CONDITIONER

WINDOW AIR CONDITIONER

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

WINDOW/WALL - TYPE ROOM AIR CONDITIONER

USER MANUAL. Safety Precautions. Operating Instructions. Installation Instructions. Care and Cleaning. Troubleshooting Tips

USER MANUAL MWB. Window Type. MWB10CW71 MWB08CW71 MWB06CW71

Room Air Conditioner

Room Air Conditioner

Portable Air Conditioner

Use & Care. Room Air Conditioner. All about the. of your TA B L E O F C ONT ENT S. Care and Cleaning... Energy Saving Ideas... Product Registration...

Use & Care. Room Air Conditioner TABLE OF CONTENTS

Room Air Conditioner

Using the Remote Control Unit

Use & Care. A ir Conditioner Features... 5 Major Appliance Limited Warranty TABLE OF CONTENTS

15,1 TU -25,000 TU AiR CONDITIONERS ELECTRONIC CONTROLS

Dual-Hose Portable Air Conditioner User Manual

ROOM AIR CONDITIONER WARRANTY


3.2 CU FT REFRIGERATOR

Use & Care. Room Air Conditioner. All about the. of your TABLE OF CONTENTS. Before You Call Major Appliance Limited Warranty...

ROOM AIR CONDITIONER TABLE OF CONTENTS. Important Safety Instructions Installation Instructions

ROOM AIR CONDITIONER OWNER'S MANUAL

Use & Care. Portable Air Conditioner TABLE OF CONTENTS. Important Safety Instructions Air Conditioner Features... 8

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Portable Air Conditioner

Room Air Conditioner

Room Air Conditioner

Owner s Manual Window Air Conditioner

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

Inverter Split-type Room Air Conditioner

Owher s. 9-syj ROOM AIR CONDITIONERS. Note to You. Instructions. Parts and Features. Operating Your Air Conditioner. Personalizing the Front Panel

GDDEM10 DEHUMIDIFIER

USER MANUAL FOR MODELS: 2PAC6000 2PAC8000 2PAC PAC PAC Your Source for Home Comfort

User Manual

Owner s Manual Super-Slim Four-Way Cassette

USER MANUAL FOR MODELS: 4PAC6000 4PAC8000 4PAC PAC12000 COMFORT...BUILT TO LAST 6,000, 8,000, 10,000 & 12,000 BTU WINDOW AIR CONDITIONER

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

FRIGIDAIRE J ;;}{ } L. Conditioner Featu. operating Instructi(

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

KSD-35 DR11 KUE-35 DVN11

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

IMPORTANT INSTRUCTIONS READ & SAVE

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

USER MANUAL FOR MODELS: 4FPC FPC12000 COMFORT...BUILT TO LAST 10,000 & 12,000 BTU WINDOW AIR CONDITIONER

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

5,000 BTU MECHANICAL WINDOW AIR CONDITIONER

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

USER MANUAL FOR MODEL: 4PAC5000 COMFORT...BUILT TO LAST 5,000 BTU WINDOW AIR CONDITIONER

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

DEHUMIDIFIER INSTRUCTION MANUAL

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Kenmore Elite. Low Profile Single Room Air Conditioner Tipo De Sala De Ventana De Aire Acondicionado. Use & Care Guide Manual de Uso y Cuidado

Models WM1-06E-01 WM1-08E-01 WM1-10E-01 WM1-12E-01 WM1-12E2-01. Electronic Window Air Conditioner Operating Instructions V ,400 BTU 8,500 BTU

SPLIT TYPE. Instruction manual

Gallery Electric Fireplaces

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

HIGH VELOCITY METAL WALL MOUNT FAN 20" AMPS: 1.2 / WATTS: 140 / VOLT: 120 READ AND SAVE THESE INSTRUCTIONS

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

IMPORTANT INSTRUCTIONS READ & SAVE

Transcription:

Before using your air conditioner, please read this manual carefully and keep it for future reference. WINDOW/WALL-TYPE ROOM AIR CONDITIONER Prior to installation this air-conditioning unit must be submitted for approval by the utility service which provides electricity.

CONTENTS 1. IMPORTANT SAFETY INSTRUCTIONS...2 2. POINTS FOR USING AIR CONDITIONER...3 3. UNIT PARTS IDENTIFICATION......4 4. AIR CONDITIONER FEATURES...5 5. CARE AND CLEANING...7 6. INSTALLATION...8 7. TROUBLESHOOTING TIPS...11 8. SPECIFICATIONS...12 NOTE: This User s Manual provides specific operating instructions for your model. Use the room air conditioner only as instructed in this User s Manual. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. 1

IMPORTANT SAFETY INSTRUCTIONS WARNING For your safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord. WARNING All wiring must comply with local and national electrical codes and be installed by a qualified electrician. Never insert your fingers or any foreign objects into the air outlet. Take special care to warn children of these dangers. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a threeprong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner with outside protective cover in place. This could result in mechanical damage within the air conditioner. Do not use an extension cord or an adapter plug. Energy Saving Ideas Electrical Information The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation. Install the room air conditioner on the shady side of your room. Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs, enclosures, or other buildings. Keep blinds and drapes in other windows closed during the sunniest part of the day. Clean the air filter as recommended in the section Care and Cleaning. 2

POINTS FOR USING AIR CONDITIONER WARNING To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance. NOTE: If the air conditioner is turned off, wait 3 minutes before restarting. This allows pressure inside the compressor and equalize. Failure to follow these instructions may be harmful to your unit. To begin operating the air conditioner, follow these steps: 1. Set the thermostat to the highest number (coldest or cooler setting). 2. Set the selector control to the highest setting. 3. Adjust the louver for comfortable air flow (see AUTO SWING). 4. Once the room has cooled, adjust the thermostat to the setting you find most comfortable. 5. Make sure that the air flow inside and outside are not obstructed by anything. 6. This air conditioner is designed to be operated under conditions as follows: Outdoor temp.: 18-43 O C(T1Environment) 21-52 O C(T3Environment) Cooling Operation Indoor temp.: 18-32 O C(T1Environment) 18-32 O C(T3Environment) Note: The relative humidity of home should be less than 80%. If the unit is used in a condition with a relative humidity over 80%, there will be condensed water on the appearance of the unit. If the unit is operated beyond the conditions specified above, it may cause a failure of the unit. 3

UNIT PARTS IDENTIFICATION 1. Front panel 2. Air filter 3. Frame 4. Cabinet 5. Air inlet grille (outdoor side) 6. Air outlet grille 7. Operation knob 8. Power supply cord and plug ACCESSORIES Drain Plug(option) Seal Drain Pan (option) Screw(Fasten the front panel) 1 1 1 2 1. Power cord conductors are distinguished according to color as follows (see Fig.1) 2. For your safety and protection, this unit is earthed through the power cord (see Fig.2) Please contact the manufacturer or its service agent or a similar qualified person if you want to replace it. 3. Be sure that the unit being correctly grounded. The wall outlet (Air-break switch)should be provided with reliable earth wire. 4. The unit should be provided with an individual circuit and the circuit breaker/fuse rating should be the same as that of the power cord and wall outlet. POWER CORD A E Wall outlet Air-break switch N E-Earth wire, yellow/green N-Neutral wire, blue A-Active wire, brown Fig.1 Fig. 2 4

AIR CONDITIONER FEATURES THERMOSTAT OFF ER AUTO SWING POWER ON MED SELECTOR OFF MED THERMOSTAT ER SELECTOR OFF WAIT THREE MINUTES BEFORE RESTARTING WAIT THREE MINUTES BEFORE RESTARTING POWER indicator(some models without): This indicator light remains on when the unit is on and goes off when the SELECTOR is on OFF position. NOTE: The outline of the operation panel is based on typical model, the function is the same with your air conditioner while some difference may exist in appearance. SELECTOR MED MED SELECTOR OFF OFF OFF MED The controls featured in this manual are representative of many available models. Your model may offer slightly different features. Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location. has maximum cooling effect and airflow. has minimum cooling effect and airflow. MED has the intermediate cooling effect and airflow. OFF will completely shut off the unit. Fan Mode Rotate the knob to the left to select your choice of fan speeds for air circulation. Note: When selecting a fan speed, the compressor will not run. Note When turning the SELECTOR knob from " " to " ", keep your speed slow as far as possible. Do not change the operation mode between " " and " " too often. 5

THERMOSTAT THERMOSTAT ER Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in the MODE. To set the desired room temperature, rotate the thermostat switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature. Rotate the thermostat selector clockwise for higher cool settings. Higher cool settings will provide lower room temperature. Rotate the thermostat selector counter clockwise for lower cool settings. Lower cool settings will provide higher room temperature. NOTE: During the cooling operation of the unit, when the thermostat knob is rotated clockwise, allow at least three minutes before turning back the knob to the ER direction. Otherwise the fuse may blow due to an overload of the unit. AUTO SWING AUTO SWING Horizontal air flow adjustment (automatically) OFF ON When the AUTO SWING switch is turned to ON position, the vertical louvers automatically oscillate right and left sweeping the cold air alternately to obtain comfortable cooling. The vertical louvers may be stopped at any position when the AUTO SWING switch is turned OFF. 6

Vertical air flow adjustment (manually) To adjust vertical air flow direction, adjust any one of the horizontal louver blades. When turning up or down the horizontal louver blades, always keep horizontality the top or bottom blades. This can effectively prevent water drops condensed on the front panel of the unit. Vent Control The vent control is located above the control knobs. The operation method is different on different models (see the following figures). For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. CLOSE VENT OPEN To open the vent, pull the lever toward you To close it, push it in. CLOSE OPEN To open the vent, set the lever to the right position To close it, set the lever in the left position. NOTE: The VENTILATION LEVER should normally be kept in the CLOSED position during cooling for maximum cooling effect. The "OPEN" position is used only for ventilation. CARE AND CLEANING CAUTION Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent chock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. 7

CARE AND CLEANING(CONTINUED) Hold the slot under the front panel, then uplift it onwards, and remove the front panel. Pinch the handle under the air filter and make the air filter arched, remove it from the underside to upside. Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean. Note: Never use hot water over 40 C(104 F) to clean the air filter. Never attempt to operate the unit without the air filter. Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. Plug in air conditioner. NOTE: Never use water over 50 C, alcohol, gasoline, acid, solvent or brush to clean the front panel as this will damage the surface of the part. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. INSTALLATION & Select The Best Location Install the unit at a place having sufficient strength to support the unit securely. For maximum efficiency, install the air conditioner on a side of a house or building which favors more shade than direct sunlight. Provide sufficient clearance or space around the air inlet and air outlet so that air flow will not be obstructed, following figures give detailed requirements. Only trained and qualified service personnel should install, repair or service air conditioning equipment. Users should not install the air conditioner by themselves. 8

INSTALLATION(CONTINUED) Less than C more than D Scrape 45 O Wall thickness is less than C If the wall thickness is more than scrape the wall as shown above. C Less than C 5-10mm More thana more thana Make rear side lower so that water will drain out smoothly. More than B A B C D Size(mm) 400 500 210 60 The Treatment of Condensed Water To meet different requirement of different type of air conditioner, there are two kinds of methods for your choice to treat the condensed water. You can choose back drainage or non-drainage. See the following procedures to perform back drainage: 1. Fit the seal onto the drain joint (which provided with your air conditioner accessory). 2. Remove the rubber plug from the back of the unit. 3. Attach the drain joint to the back of the cabinet O where you remove the plug and rotate 90 to securely assemble them. 4. Connect the drain joint with a extension drain hose (Locally purchased) DRAIN JOINT SEAL RUBBER PLUG 9

Installation Steps Step 1. Remove the front panel and the air filter 1. Hold the slot under the front panel, then uplift it outwards, and remove the front panel (See Fig.1). 2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside (See Fig.2). 4 5 6 Step 2. Remove the frame. 1. 2. Remove the two fixed screws from the frame. (see Fig.3) Grasp the left corner in the frame's underside, the loosen the frame. (see Fig.4) Step 3. Installation 1. Remove the screws fix the chassis-fixing board and cabinet. some Models have two more screws on the back of the cabinet. (see Fig.5) 2. Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet. (see Fig.6) 3. When need to drain off water, intall the drain plug on the Chassis board. Then fix the cabinet on the supporter (provide for yourself or contact the dealer)(see Fig.7). 4. Push the unit chassis into the cabinet. (see Fig.8) 5. Fix the chassis and cabinet. (see Fig.5) 10

Step 4. Install the frame 1. Install the frame. (see Fig.9) 2. Fix the screws on the frame. (see Fig.3) Step 5. Install the front panel and the air filter. 1. Install the air filter into the frame's slot from upside to underside. (see Fig.2) 2. Hang the front panel on the frame's buckle, then press the front panel into the frame's slot until hear a click. (see Fig.10) Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Problem Solution Air conditioner does not start TROUBLESHOOTING TIPS Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Selector Control in OFF position. Turn selector to the desired or setting. Unit turned off by moving thermostat to a higher number and then immediately turning back to a colder number. Wait approximately 3 minutes. Listen for compressor to start. Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before restarting. Thermostat set too low. Adjust thermostat to higher number for cooling. Air from unit does not feel cold enough Turn selector to a higher position. Thermostat set too warm. Set thermostat to colder temperature. O O Room temperature below 18 C(64 F). Cooling may not occur until room temperature O O rises above 18 C(64 F). Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil. Air conditioner cooling, but room is too warm- ice forming on cooling coil behind decorative front. O O Outdoor temperature below 18 C(64 F). To defrost the coil, set selector to position. Then, set thermostat to warmer position. Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set selector to. Thermostat set too cold for night-time cooling. To defrost the coil, set selector to a position. Then, set thermostat to a warmer position. 11

Problem Air conditioner cooling, but room is too warm- NO ice forming on cooling coil behind decorative front. Solution Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section. Thermostat set too warm. Turn thermostat clockwise to a colder setting. Air directional louvers positioned improperly. Position louvers for better air distribution. Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit. Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers. Unit recently turned on in hot room. Allow additional time to remove Stored heat from walls, ceiling, floor and furniture. Air conditioner turns on and off rapidly Noise when unit is cooling Water dripping INSIDE when unit is cooling. Water dripping OUTSIDE when unit is cooling. Dirty air filter- air restricted. Clean air filter. Outside temperature extremely hot. Set to high cool to bring air past cooling coils more frequently. Air movement sound. This is normal. If too loud, turn selector to lower setting. Sound of fan hitting water-moisture removal system. This is normal when humidity is high. Close doors, windows and registers. Window vibration - poor installation. Refer to installation instructions or check with installer. Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions - check with installer. Unit removing large quantity of moisture from humid room. This is normal during excessively humid days. SPECIFICATIONS Unit dimensions: MODEL(Btu/h) <9000 9000<Model<12000 12000<Model<18000 > 18000 BODY DIMENSION(mm) (WxHxD) 450x345x560 600x380x560 661x428x675 661x428x675 12

Minimum norminal cross-sectional area of conductors: Rated current of appliance (A) Nominal cross-sectional area (mm 2 ) 0.75 1 1.5 2.5 Suggest Minimum Wire Size( AWG: American Wire Gage) : Appliance Amps AWGWireSize 10 18 13 16 18 14 25 12 30 10 13

CS355-U 2200019053