Thermal Shock Chambers. acstestchambers.com

Similar documents
TEMPERATURE SHOCK TEST CHAMBERS

Vibration. test chambers. acstestchambers.com. powered by

Dry Corrosion. Test Cabinets. acstestchambers.com

Dry Corrosion. Test Cabinets. acstestchambers.com

UMWELTSIMULATION TEMPERATUR VARIO. Walk-in chambers in modular design for multifunctional applications in different industrial fields

Sunrise the beginning of a brand new day

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

I N D U S T R I E S p A M O R E T H A N T E C H N O L O G Y MOTHER MILK REFRIGERATOR / FREEZER

Thermal Shock Chamber TSE 11

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Reproducible Climate...

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Compact Ultra Low Temperature Chamber

VS LD series vertical steam sterilizers

EXCAL ENVIRONMENTAL TEST CHAMBER A STEP FURTHER ENVIRONMENTAL SIMULATION

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Remote Conditioners. RC-Series. ZPRC Series

Altitude Chambers.

Best Freeze Drying Solutions

Remote Conditioners. RC-Series. ZPRC Series

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Environmental simulation chamber for complex alternating climate profiles

Internet. Climate rating definitions. Customer service.

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Benchtop & Compact Test Chambers

Thermal processing equipment design and craft for laboratories and industry Vilnius, Lietuva

Protection, safety, reliability. And more.

Constant climate chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Medical Refrigerators

BIOMEDICAL REFRIGERATORS

DEKO 25 washer-disinfector

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

PR / MP I Laboratory / Medicine

Pilot Freeze Dryers Smart Processes

NC 100. Vertical Steam Sterilizer

Constant climate chamber with humidity

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Epsilon 1-4 LSCplus Epsilon 2-4 LSCplus

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

A660 Air Conditioning Laboratory Unit

FITOCLIMA 600 & 1200 STABILITY

FitoClima / FitoTerm SOL chambers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

FITOCLIMA 600 & 1200 PHARMA

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Air & Water Heat Pump R832

WR-KWAP (Platelet incubator/agitator) HPL

Long Term Storage Cabinet

Chromatographic Air circulated Refrigerator, two-door TC 603

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Environmental Chambers

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.


Laboratory Refrigerator/Deep Freezer TC 802

laboratory & sterilization technology

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

MEDICAL DEVICES. Blood bank refrigerators and freezers

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Laboratory refrigerators

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

DEKO Washer-disinfector WASHROOM SYSTEMS

Vacuum drying oven for non-flammable solvents

LABOKLAV. Autoclaves Made in Germany

FITOCLIMA 600 & 1200 BIO

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

HSD Dry Cabinet

DEKO 260 Washer - Disinfector - Dryer

HSD Dry Cabinet. Outstanding performance

Faster Temperature (& Humidity) Chamber

NEW GENERATION. Efficient use of valuable space INCUBATORS

Process Alarm Solutions

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

TCC-34. Features: TISSUE CULTURE

Temperature Cycling Chambers Global-N Series

Rotary Screw Compressors ASD Series

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

ULTRA LOW TEMPERATURE FREEZERS -40 C -86 C HPL LINE (High Performance Line)

Environmental Stress Chamber AR series

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Transcription:

Thermal Shock Chambers acstestchambers.com

Angelantoni Test Technologies stay ahead to meet the needs of the Industry of the Future, where Internet Technology, Remote Connections, Communication & Networking are the keywords for success.

CST130/2T Thermal Shock Chamber ACS is proud to announce the new Thermal Shock Chamber CST130/2T spinner! A new design for a more compact and precise equipment, powered now by the powerful and hyperconnecting control system MyKratos, which makes it possible to manage and monitor the chamber from the on board panel and desktop/mobile devices.

Thermal Shock Chambers CST130/2T The CST130/2T spinner vertical thermal shock test chamber is made up of two test chambers placed one on top of the other: a hot chamber above and a cold chamber below. The machine takes its name from the spinner, the mechanism that moves the basket from one chamber to the other. The basket, which holds the products to be tested, is moved electrically by means of a motorized worm drive that ensures a fast transfer speed and significantly reduced vibrations. 4 NEW 10 ON BOARD DISPLAY Powered by MyKratos software, it makes available all the chamber functions from the operator panel with the same user-friendly interface presented on remote devices The same software in any device to manage all the chamber functions from the on-board panel and remote devices (PC, tablet and smartphones) NEW ECO FRIENDLY REFRIGERANT R449A With low GWP (Global Warming Potential), compliant with European Regulation 517/2014 New Interactive Assistance Support System which monitors the chamber to guarantee faster and more efficient services. MyAngel24 now features new functions for automatic reporting, self-diagnosys and preventive maintenance

CST130/2T spinner Main Technical Data Basket capacity 130 lt Basket useful dim. 614x500x425 (WxDxH) mm approx Maximum basket load 50 Kg Chamber external dim. 1252x2072x2844 (WxDxH) Temperature range (measured at room temperature of 22 C, empty working space and nominal voltage): upper chamber +70/+220 C lower chamber -80/+100 C Temperature fluctuation: ±1 C Basket displacement speed <10 sec. Max load with MIL 883 test (15 min resetting time on specimen): 13 kg Ics distributed on 2 shelves with MIL 883 test D 20 kg Ics distributed on 2 shelves with MIL 883 test C 26 kg Ics distributed on 2 shelves with MIL 883 test B Main Standards MIL-STD-883H, method 1010.8, test conditions A, B, C, D, F MIL-STD-810G (*), method 503.5 procedures I-B, I-C, I-D IEC 60068-2-14 test Na (*) with dedicated SW Rich basic configuration Electronic control of the ON/OFF solenoid valves makes it possible to optimize the operation of the cooling system according to the machine s working conditions Compressed air drying columns to improve chamber performance in terms of productivity, for long-term tests without the need to use defrosting cycles The new CST130/2T spinner allows you to add a preconditioning and postconditioning stage to the test cycle: - Preconditioning allows the obtaining of cycles that are closer to the thermal profile set in the first stages; - Postconditioning allows the specimen to be moved more rapidly at the end of the cycle. To speed up the cooling of the hot chamber, it is equipped with a compressed-air flushing system Hardware device for intelligent control of the heating elements, which by means of dedicated software algorithms reduces the absorption peaks, and thus saves energy Internal design conceived to obtain an ideal air flow that is optimized for the most demanding standards, such as the MIL-STD-883H METHOD 1010.8 Free PT100 sensor inside the basket, Port (95 mm), Electrical panel with IP54 protection, inspection window 5 ACS Smart Cooling Kit Developed by Angelantoni Test Technologies, ACS Smart Cooling Kit (patent pending) is a new concept of the compressor Stand-by mode, included in the chamber basic configuration, based on an innovative configuration of the refrigeration circuit managed through new, dedicated software algorithms. The new system allows a more efficient management of pressures upstream and downstream of the compressor, producing a better control of the cooling capacity and a reduction of the mechanical effort. The resulting benefits are: Up to 20% reduction of power consumption Up to 50% noise attenuation Increased system reliability Better temperature regulation inside the chamber Stand-by mode: the compressor works in reduced effort conditions, during the phases in which cooling capacity is not required. Total stand-by times can even reach 70% of the total time of a test

Thermal Shock Chambers CST130/2T spinner TM Control System Thanks to their hyper-connectivity, ACS test chambers equipped with MyKratos can match current and future needs related to the new demands of the Industrial Internet of Things and Industry 4.0 for integrated, interconnected and communicating machines. 6 Available on the new 10 inch display Simple to use graphical interface Clarity, consistency and efficiency of use Embedded Control Software MyKratos inside, to control monitor and assist the chamber from any device. No additional hardware or software required Free App to fully manage the chamber via mobile devices (Google Play and Apple Store) Easy remote access and control via integrated Wi-Fi / mobile network and Ethernet Chamber Internal Cloud for data storage The interface consists of a powerful software accessible from the 10 inch on board display and from remote devices (PC, tablet, smartphone), MyKratos, including the interactive assistance system MyAngel24. The chamber is equipped with a PLC (Programmable Logic Controller) for managing all the chamber s functions and safety interlocks. A special device controls the chamber via mobile devices, such as tablets and smartphones, or establishing a remote Internet connection. Ethernet WiFi Mobile network ACS Server WiFi Internet VPN Customer Home/Office WiFi Customer LAN

Air-to-Air or Liquid-to-Liquid: Extreme versatility ACS complete line of thermal shock chambers includes either Air-to-Air or Liquid-to-Liquid models, designed for thermal shock tests on components or complete equipment by submitting them to rapid temperature changes automatically. They are suitable for Quality Control Laboratories or in Production plants for the screening of commercial and military components. 7 The ACS Air-to-Air thermal shock chambers meet the following standards: The ACS Liquid-to-Liquid thermal shock chambers meet the following standards: MIL-STD-883H, method 1010.8, test conditions A, B, C, D, F MIL-STD-810G (*), method 503.5, procedures I-B, I-C, I-D IEC 60068-2-14 test Na MIL-STD-202G, method 107, test conditions AA, BB, CC MIL-STD-883H, method 1011.9, test conditions A,B,C IEC 60068-2-14 test Nc (*) with dedicated SW The extreme versatility of ACS chambers allows users to carry out a wide range of tests necessary to determine thermal characteristics under the effect of two alternating extreme temperatures. lt is possible to offer standard or custom-designed models, either vertical, horizontal or "walk-in" types. Their wide range of accessories, the large range of temperatures, the reliability of the mechanical cooling systems and the After-Sales Service Assistance contribute to make ACS chambers an essential factor for Quality ControI and Production facilities.

Thermal Shock Chambers The Traditional Approach Air-to-Air Thermal Shock Chambers: Two temperature method, specimen moving with the basket Traditional version with specimen moving in the basket 8 Vertical model, chain movement = CST320 2T Horizontal models, pneumatic movement = CST500 2T, CST1000 2T The two test compartments can be placed vertically or horizontally. An electrically driven basket moves between the two temperature zones which will produce a thermal shock on the specimen. The vertical model is available with basket useful volume of 320 litres; horizontal models are available with basket useful volumes of 500 and 1000 litres. Special models are available on request. The external structure is in painted carbon steel grey RAL7035; the interior and the basket are in AISI 304 stainless steel. The doors (one for each test compartment) are fitted with safety microswitches which immediately stop the chamber s operation when one of the doors is open. MODEL Basket dims. mm (WxDxH) Ext. dims. mm (WxDxH) Thermal load (Kg*) Weight (Kg) Voltage** (VAC) Rated Power (kw) Max CST320 2T 700x700x650 1530x2900x2400 15/7 1600 400 V ±10%/50Hz/3ph + N + G 29,1 CST500 2T 630x900x900 3830x2060x2640 25/13 3500 400 V ±10%/50Hz/3ph 48 + N + G CST1000 2T 730x1000x1400 4490x2360x2650 50/30 *** 4500 400 V ±10%/50Hz/3ph 91,2 + N + G * reference value in order to achieve the following recovery times : 2 min in the range -55/+125 C - 5 min in the range -65/+150 C ** other voltages or frequencies on request, according to customers specifications *** reference value in order to achieve the following recovery times : 6 min in the range -55/+125 C - 11 min in the range -65/+150 C

An Alternative Approach Air-to-Air Thermal Shock Chambers: Two temperature method, specimen fixed in its position Alternative version with specimen fixed in its position, flapper models The concept flapper is an innovative approach to thermal shock which can dramatically improve the space crowded situation of many testing laboratory and increase the use flexibility. The specimen is fixed in its position and the chamber is connected alternatively to hot and cold chambers (by flaps ). This technical solution creates the possibility of the unit being capable of performing as a standard thermal shock chamber and also gives the possibility to perform ESS tests and conventional thermal cycles. This style eliminates the problem of having to worry about cables that may need to travel with your test items. Since the unit under test stays in place it is easy to connect any wiring or sensors necessary to verify test results. The number of cycles before defrosting is considerably increased thanks to a pressure compensation system (bellows connected to both cold and hot rooms). Additional feature Further to the traditional thermal shock, the chamber can be used for some environmental stress screening and temperature profiles with a dedicated S W. According to MIL STD 883 and IEC 68-2-14 9 Temperature range Temperature accuracy in time Heating temperature rate from -55 C to + 125 C* Cooling temperature rate from +125 C to -55 C* Recovery time (-55 C / +125 C ) with 5 Kg load (IC) (*) with reference temperature sensor on the air blow out -80 C/+220 C ±0.5 C 40 C/min 20 C/min 15 min MODEL Basket dims. mm (WxDxH) Ext. dims. mm (WxDxH) Max load (Kg*) Weight (Kg) Voltage** (VAC) Rated Power (kw) Max CST130 S flapper 580x510x420 1400x1780x1950 30 1300 400 V ±10%/ 50Hz/3ph + N + G 19,8 CST320 S flapper 700x700x650 2740x1700x2450 50 2400 400 V ±10%/ 50Hz/3ph + N + G 39 ** other voltages or frequencies on request, according to customers specifications

Thermal Shock Chambers Air-to-Air Optional Accessories 10 LN2 Auxiliary Cooling ACS thermal shock chambers can be equipped with an auxiliary cooling system with LN2 supplied by means of centralized tank or bottles. This auxiliary cooling system achieves a fast temperature recovery time in the same T range when the thermal load in the basket is exceeding the load limits. Another application is when the test has to perform low temperature values that cannot be achieved with the traditional mechanical cooling systems only (e.g. down to -180 C with LN2). In this case the equipment must be adapted with suitable thermal insulation and special construction. On request we can supply our chambers with LN2 only, without mechanical cooling. Graphic Recorder A six-channel μprocessor graphic recorder can be installed to previde a continuous recording of all the temperatures measured by the chamber. The recorder is provided with a digital display showing the actual printed value. lt is possible to print the time scale and the values unit dimensioning (according to the lnternational System of Units - ISU). The prints are made with 6 different colours. The six channel recorder is complete with two Pt100 probes, one for each cabinet. Specimen Temperature Recording Additional thermal probes can be connected to the recorder to measure the temperatures at additional points. The probes are installed in the movable basket passing through two special dedicated portholes (see further accessories). Connecting Portholes Various sizes of portholes are available according to chamber models. They allow an easy electric connection between equipment external to the chamber and the devices under test in the basket. Gaseous Nitrogen (N2) Purging System This system allows to avoid the condensation of internal humidity on the specimen under test, thus increasing the number of cycles before defrosting. The use of this option also eliminates the presence of oxygen in the chamber to prevent oxidation phenomena at high temperature on the contacts of the components under test. It is optional for 500 and 1000 l horizontal models, while it is included for 320 l vertical model (not available for flapper models). Set of no. 8 auxiliary contacts RS 232 interface + Winkratos SW For remote control and programming via PC. Remote air condenser (on request) Special voltages or frequency (on request)

Air-to-Air Features and benefits Constructive features Carbon steel, industrial paint finish, exterior; stainless steel AISI 304 interior, 18/8. Argon welded internal chamber. The internal structure is connected to the external structure by means of phenolic joints. 2 ea. large full-light doors with soft double silicone gaskets and key-locks. Internal ventilation realized by means of powerful propeller fans driven by external motors. They are provided with stainless steel shafts. Cooling systems driven by two cascade compressors complete with safety valves and thermal protections. Refrigerants: R449A for the first stage and R23 for the second stage. Heating system by means of armored finned type electric heaters. They are protected by adjustable failsafe overtemperature switches. Control and regulation by means of a PLC controller/programmer. Its control is based on PID feedback principle. Input/output are connected to Pt100 platinum variable resistance probes. Thermal probes: Pt100 platinum probes with 100 ohms at 0 C as per DIN specifications. Electric connections according to IEC specifications. Blowers stop during the basket movement. Microswitches on chamber doors. Safety push button in case of emergency. Your Advantages Heavy and rabust construction, ergonomic features and elegant design. No rust formation. No humidity penetration. No thermal bridge between internal chambers and external environment, resulting in energy savings. Full accessibility to the chambers. No water vapour infiltration at low temperatures. Possibility to use the cabinets separately. Quick response of the specimen to temperature changes. Uniform temperatures inside the cabinets. Rapid cooling with low noise level. Maximum reliability of the equipment. Low level of vibration. Ozone friendly and non-inflammable refrigerants. Low cost of operation. Fast recovery times due to low thermal inertia. Heat radiation in the cabinet is minimized. Fast thermal response with continuous and linear control over the whole range. Precise control of temperatures by means of Pt100 thermal probes. Fast response and good linearity in the range -100 C to + 200 C. High reliability and operator safety. Reduced air mixing between the cold and hot chambers. Chamber stop in case of doors opening. Operator safety. Easy protection of chamber and specimen in case of faiiure. 11 Undercooling or overheating operation modes available. Faster temperature recovery time after basket transfer.

Thermal Shock Chambers Liquid-to-Liquid For more severe testing 12 ACS has developed and is producing a full range of chambers for Liquid-to-Liquid thermal shock tests. This standard range of chambers meets any commercial or military test specification. The chamber body is gray RAL 7035, the front is blue RAL 5015. Two powerful compressors are connected in cascade and provide rapid and reliable temperature cooling performance. Environmentally friendly refrigerants are also used. The basket movement is electrically operated. The time needed by the basket to move from one well to the other is less than 10 seconds. A plexiglass cover door closes the test volume in order to minimize the liquid consumption by evaporation. The ACS Liquid-to-Liquid thermal shock chambers are designed to use one fluid only such as the GALDEN D02. A special evaporator for the fluid vapour condensation (fitted as standard) is placed over the wells, and allows condensation and recovery of the fluid vapours. These features put our chambers at the top range of the worldwide production with highly reduced fluid consumption (i.e.approx.3 g/h for CSTL20 and only 0,5 g/h for the CSTL12!!). The chamber is equipped with an expansion bellow used for pressure compensation during the test operations. This avoids overpressure inside the chamber that can force the door and cause fluorinert leaks. The CSTL models can be equipped with a wide range of accessories (recorders, customized shelves for the specimen, vapour suction blower with automatic butterfly valve, etc.). CSTL20 MODEL Basket dims. mm (WxDxH) Ext. dims. mm (WxDxH) Thermal load (Kg*) Weight (Kg) Voltage** (VAC) Rated Power (kw) Max CSTL12 120x120x120 1200x1100x1940 1,5/0,8 700 400 V ±10%/50Hz/3ph + N + G 6 CSTL20 200x200x200 1400x1300x2130 2,5/1,5 950 400 V ±10%/50Hz/3ph 10 + N + G * reference value in order to achieve the following recovery times : 2 min in the range -54/+125 C - 5 min in the range -65/+150 C ** other voltages or frequencies on request, according to customers specifications

Control system and user interface Basic Configuration: KeyKratos Plus Hardware 65536 colours with TFT technology Faster control Memory support for recordings and alarms Secure digital card, pendrive (USB key style), Internal memory Software User friendly data input during editing, check and administration of cycle Real time recording of temperatures versus time (LOG on SD) USB interface on front panel for stick or printer Recordings in CSV format (Comma Separated Value) for easy export to Excel, program files are easily convertible into graphic format The system is available in 6 languages: Italian, English, German, Spanish, French, Dutch 13 Optional: WinKratos software for remote control and programming via PC Winkratos S/W package (running under Windows 7 or higher) offers a powerful and flexible control & management system. lt allows the user to: Control and Monitor the chamber from a remote personal computer Create and Manage a test programs archive Record and Manage a test records archive Graphic functions Graphic monitoring of chamber measure behavior with multiple charts panel Delayed Start of the chamber to optimize time scheduling Graphic test pragrams editor with two editing mode: entry-level and advanced Acquisition functions Record of occurred events such as alarms, commands, etc. Record of chamber values during tests Additional functions Print test programs in text format Export test data recorded in ASCII format Possibility to add notes on the graph Global monitor to control many chambers at the same time

Angelantoni Test Technologies, owned by the Angelantoni Group, is the only company capable of offering a comprehensive range of environmental test chambers - ACS branded - for a great variety of applications, thanks to the expertise and technical know-how of its teams of experts. Innovation, flexibility and organization have always been the keys to success for ACS, world-famous since 1952 also for its high-tech test equipment such as Thermal High Vacuum Chambers for Aerospace applications and Calorimeters. Angelantoni Test Technologies Località Cimacolle, 464 06056 Massa Martana (Pg) - Italy Tel. +39 075.89551 (a.r.) Fax +39 075 8955200 info@acstestchambers.it

Angelantoni Test Technologies Srl - All rights reserved

EN Angelantoni Test Technologies Srl - All rights reserved - September 2018 - Illustrations, descriptions and technical data may be changed without notice Subsidiaries Ofterdingen, GERMANY info@att-umweltsimulation.de Paris, FRANCE info@attfrance.fr Beijing, P.R. CHINA info@attasiapacific.com Noida, INDIA info@attindia.in Angelantoni Test Technologies Loc. Cimacolle, 464-06056 Massa Martana (Pg) - Italy Tel. +39 075.89551 (a.r.) - Fax +39 075 8955200 info@acstestchambers.it www.att-testing.com www.acstestchambers.com