Dangerous Assumptions

Similar documents
BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

Shared Services Partnership

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

Loss Prevention Standards

Lakanal House inquest: Statement from the Fire Sector Federation

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

Waking Watch / Common Fire Alarm. Guidance to support a temporary simultaneous evacuation strategy in a purpose-built block of flats

Secretary of State determination under article 36 of the Fire Safety Order

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

Inspection & maintenance of fire doors a credible action plan. Presented by Clive Reilly Checkmate Fire Solutions Ltd

NOTTINGHAM CITY HOMES

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

PASSIVE FIRE PROTECTION GETTING IT RIGHT

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017

Managing technical risks

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Electrical Safety Policy and Management System

Martin Paren HM Inspector of Health & Safety

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Fire risk management plan. MH/05/Revised/06/17

Managing Fire Safety Through Construction. Reece Walker Arup Fire Engineer

SECURITY SERVICE LEVEL AGREEMENT

West Yorkshire Fire & Rescue Authority. Fire Protection Policy

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

Management Standard: Fire Safety

A 92 plus B C D E F 21-38

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Grenfell Tower Inquiry

Health and Safety Services. Safety Guide 5. Fire drills

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Why should getting a Fire Risk Assessment right be a vital management policy?

Standards and third party certification

A 92 plus B C D E 39-54

Energy Performance Certificate

Property Health and Safety Compliance at Housing and Education Centres

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

FP-PGN-14 Part of NTW(O)41 Fire Policy

Fire Risk Assessment Guide

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

Fire Risk Assessment Guide

Energy Efficiency Rating

BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS

Environmental Impact Assessment

Passive Fire Protection SEMINAR INTRODUCTION & OVERVIEW

Effectiveness of sprinklers in residential premises:

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

We can help you with the Fire Risk Assessment. What s more, we can help you put your evacuation plans in place.

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

Evacuation of Mobility Impaired Persons. Staff News: New Fire Evacuation Policy and Procedures Important for all staff and students

Fire Safety Management Audit Specification August 2017

Functional Safety: the Next Edition of IEC 61511

EVOLUTIONS FIRE PROTECTION

BRE & LPCB Ruth Tucker -Passive Fire Protection

The Association for Specialist Fire Protection

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

Exova Warringtonfire - Expert Witness Directory 2018

Fire Risk Management in Sheltered Housing

Practice Advisory 18: Fire safety design for tall buildings

Appendix 1 Fire safety and the Council s response to the Grenfell Tower Tragedy

FINAL VERSION. Report for London Borough of Hammersmith and Fulham FIRE RISK ASSESSMENT OF WOODFORD COURT, SHEPHERD S BUSH GREEN

Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:

Fire Safety Management

Energy Performance Certificate

Chesterfield Borough Council

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

Fire safety and high rise student accommodation

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

THE LOCAL GOVERNMENT GROUP GUIDE: FIRE SAFETY IN PURPOSE-BUILT BLOCKS OF FLATS

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Title: Room-sealed fanned draught flue systems concealed within voids

BETTER URBAN PLANNING

Emergency Evacuation. Made Simple. EVACUATION STRATEGIES - PROBLEMS & SOLUTIONS EXPLAINED Alan Oliver

The Association for Specialist Fire Protection

Fire Engineering in High Rise 15 November 2013

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Safety, Procedures and Risk Assessment Policy

FIRE RISK ASSESSMENT Self Assessment

London Borough of Hammersmith & Fulham

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

Fire Safety in Schools Post-Grenfell Fire

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

4.13 Security and System Safety

Related party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year

PASSIVE FIRE PROTECTION GETTING IT RIGHT

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

NOT PROTECTIVELY MARKED. Fire Legislation

Transcription:

Dangerous Assumptions In light of the lessons learned from the Lakanal House fire, the on-going competent inspection of passive fire protection is crucial to safeguarding those who put their trust in social housing. Jeremy Ockenden, Principal Fire Engineer at BRE Global The UK approach to fire safety in housing design is highly dependent on compartmentation as a strategy for inhibiting the spread of fire and managing the safe evacuation of occupants. Inadequate installation of passive fire protection, or subsequent damage to it, can however have fatal consequences as the Lakanal House fire in 2009 so tragically highlighted. Compartmentation should have protected residents who were told to stay put while the fire brigade responded. Yet the fire spread with alarming ferocity through the 14-storey block of flats in Camberwell, South London, claiming six lives, including three children. BRE Global, who assisted the London Fire Brigade and Emergency Planning Authority (LFBEPA) with its enforcement action against the London Borough of Southwark, identified major contributing issues arising from deficient passive fire resistance. Despite the warnings, problems with compartmentation are far too common, both in new builds and the existing housing stock, where errors are easily overlooked during construction. In working with clients on fire risk assessments and post-fire investigations, BRE continues to see a number of prevalent problems. Poor practice with fire resisting battens is common; typically they have not been installed in accordance with tested specifications, or are missing altogether. Fire-stopping around service cutouts is often inadequately sealed or completed with the wrong type of batten material. Similarly, pipe seals may be missed and the use of incorrect damper fixings frequently observed. Responsibility While these defects may have slipped through the net at construction stage, the on-going fire safety risk they pose falls squarely on the shoulders of the building owner or manager the Responsible Person as identified under the Regulatory Reform (Fire Safety) Order 2005. The Responsible Person has a clearly defined duty of care to ensure that buildings are managed appropriately with regard to fire risk. This includes those risks associated with inadequate passive fire protection even if they date from the time of construction, however long ago. Even if compliance certificates are held, it is unsafe to assume that a building is fully compliant with fire design standards, or that it continues to comply following historical alterations or maintenance. 1

Managers of social housing should understand the fire safety of properties in their guardianship by carrying out a thorough assessment of passive fire protection. Identification The first challenge is to identify if there is a problem and the extent of it. This can be difficult as access to inspect integral fire protection in social housing flats, particularly within walls between dwellings, is not always straightforward, often relying on tenant cooperation. It is best timed when tenants are moving out, but this can slow down the completion of potentially life-critical improvements. Housing managers should be prepared to invoke the powers at their disposal to negotiate expedient access for the fire risk engineer. A large proportion of fire-stopping defects lurk above false ceilings and in areas that are out of sight and difficult to access. It means that many potential weaknesses and gaps in passive fire protection will not be spotted even during a routine fire risk assessment. A suitably qualified specialist should be called in to carry out an initial sample survey of the building. This is a starting point that will give an indication of the quality and condition of passive fire protection to identify any deficiencies and make an expert judgement about whether there is probable cause to suspect widespread defects. Assessment If evidence of a systematic problem is found, what should follow is a rigorous process of determining the overall level of risk that these defects pose to the building. This will involve an understanding of fire dynamics, smoke movement, and the likely impacts on the building occupants, requiring expertise in fire behaviour and fire risk management. Such technical judgments rely on a forensic level of fire behaviour understanding and risk appraisal generally outside the expertise of a contractor installing passive fire protection or risk assessor. Without this insight, unqualified decisions may be taken to rip out and replace fire-stopping, involving unnecessary disruption and expense. Extensive replacement of fire-stopping may not actually be necessary, or it may be impractical if it causes undue disruption to occupants. A competent fire engineer should have the in depth knowledge of fire behaviour in order to make technical assessments of the impacts of a fire on a building and likely fire spread in its present condition. This risk assessment is paramount to the planning, design and cost rationalisation of efficient interventions to minimise intrusion on building activities. First and foremost, it provides a clear qualification of the current fire risk. Even if a defect has been identified, it may not have compromised the specified fire performance of the compartment. Can corrective work be targeted to avoid wholesale upgrades? Does the problem need action now or can treatment be safely managed in phases? 2

Planning A robust understanding of fire risk impacts will provide the scope and confidence to prioritise and plan a programme of work. This is especially important in tackling remediation in social housing settings with vulnerable residents such as extra care housing or accommodation designated for assisted living, where work should be implemented to minimise disruption and not introduce any new risks. It is advantageous to work with a fire risk specialist that can also provide coordinated expertise in planning interim strategies for fire risk management. This involves a range of often complex risk considerations. Will the current fire strategy and fire protection still function safely during a phased scheme of works, or do fire management systems need to be adjusted to address changing fire risks as work progresses? They can also advise on the implementation of suitable evacuation strategies in line with the changing logistics of work on site. Testing If an installation defect could require extensive replacement of fire protection, then testing of the current system may be advisable. Although a system may not have been installed in accordance with the tested specification, this does not necessarily mean that it will not achieve the intended standard of performance. Where it is considered plausible that a system may demonstrate the expected level of performance, it may be possible to test a sample section removed from the building to demonstrate whether the existing installation is acceptable and may be safely retained. A competent fire testing specialist may be able to assess whether a system is likely to perform to the expected standard, avoiding potentially significant costs and disruption of refurbishment for the client. Equally, they may be able to judge whether a simple modification is possible, via a desktop assessment involving professional judgment based on experience and previous test evidence. The process can help decide whether further verification of the performance (via standard testing) of an installed system is worthwhile, ensuring that time and resources are not wasted where a passive fire protection system is unlikely to perform. Resolution In summary, the following five key steps are recommended in addressing and remediating passive fire resistance risks: Survey the building to identify the presence, nature and extent of any problems with passive fire resistance. Identify the level of associated risk including: -Likely spread of smoke and fire -Persons at risk due to mobility, medical dependency or other circumstances -Presence of active fire safety systems and their reliability -Staffing considerations and safety -Other potential consequences of the risk 3

Compile a clear risk register to assess and prioritise works. Determine action: does passive fire protection need remediation or will existing installations, though not in accordance with specification, achieve the intended level of performance? Formulate a clear plan of remedial works which does not introduce new risks to the building. Inspection and treatment of passive fire resistance problems can be a major operation in terms of the cost and logistical impacts on facilities management. The best outcomes will be achieved by engaging a full service fire specialist who can provide a holistic, coordinated appraisal and strategy for risk management and treatment. This offers the most effective route to quantifying the problem, understanding the risk, controlling the cost of remediation and minimising the impacts on resident safety and comfort. ENDS www.bregroup.com Jeremy Ockenden, a Principal Fire Engineer at BRE Global, will be speaking at the third annual BRE Fire Research Conference on June 8th. Further details here: https://www.bre.co.uk/eventdetails.jsp?id=14702 Images (credit: BRE Global) (Img 1): The west face of Lakanal House showing the extent of fire spread, which started on the 9th floor, spread up to the 10th and 11th and dropped down to the 5th and 7th floors. (Img 2): Fire damaged boxing in along the 11th floor corridor at Lakanal House. (Img 3): The suspended ceiling structure on an unaffected floor at Lakanal House. 4

(Img 4): Inadequate fire-stopping of service penetrations is a prevalent defect observed during inspections of passive fire protection. (Img 5): BRE Global s 5-step plan to safeguarding passive fire protection in existing buildings. 5