Job #22 AS-BUILT ALL DIMENSIONS SUBJECT TO 1/4" TOLERANCES

Similar documents
Deaerator. Specifications

Encyclon Inc. Cyclonic Filtration Systems

INSTALLATION INSTRUCTIONS

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

TM Series. Induced Draft, Counter Flow Optional Accessories

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

1-866-PENNERS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

Tube Clamp Submittal Information Revision A: July 25, 2013

Paragon. Induced Draft, Counter Flow Optional Accessories

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Intelligent Variable Speed Pump

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

FLANGE-MOUNT CENTRIFUGAL PUMPS

MDX² INSTALLATION MANUAL

TOWN SQUARE 5 x 42 WHIRLPOOL AND BATHING POOL

3-1/2 Gallon Parts Washer

Barnes Oil Sensor Switch

americanstandard.com Phone: Fax:

IMPORTANT SAFETY INSTRUCTIONS GENERAL INSTRUCTIONS

POULTRY MARKET CATALOG

Owner s Manual. Spa Blower ONGA. Installation & operation instructions

454 INTERNATIONAL SERIES-A TRACTOR (EUROPE) (1/71-12/73) FUEL INJECTION PUMP, BOSCH INJECTION C.R. PUMP

Model # Lvl. 1 Issue Date: 4/84

teambrite Supply Mytee Escape ETM-LX-115 Electric Truckmount, 115V with 165 ft hose set and carpet cleaning wand Includes the following items:

Hoffman Specialty Pump Products

DUKE UNIVERSITY CONSTRUCTION STANDARDS

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

Easy Installation & Service

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Worldwide Contacts. Technical Data

COMPRESSOR SERVICE REPLACEMENT KIT P/N (WCC 500A, 115/60, AIR COOLED)

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Technical Data. Sizes 2 12 Inch (DN50 DN300)

2 Gallon Water Boiler

Standard Tank One (Approximately 1500 gallons)

Our Purifier systems

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

HDLV 55-Gallon Powder Drum Unloader

WATER HEATER PARTS CTN. QTY.

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

Plumbing Supply Products

1600 Series Rotating Suction Screen

R O T O - J E T O F A M E R I C A C O M P A N Y, I N C.

irritec USA irritec USA THE MODULAR SAND MEDIA FILTER TM Water Tool Filters

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

IMI CORNELIUS CHILLER

DUPLEX CONDENSATE TANK SYSTEM

Boiler Start-Up Cycle

COLD WATER START A P P L I C AT I O N S

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

Proximity Series. features: specifications: options: in-wall box. what great systems are built on.

Casey Craft

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

CL64T INDUSTRIAL TOTE WASHER

Domestic Pump Condensate Transfer Equipment

CHUGGER PUMP Chugger Max Models

HR Powder Feed Hopper

SECTION STEAM CONDENSATE PUMPS

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

IMPORTANT SAFETYINSTRUCTIONS GENERAL INSTRUCTIONS

Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube-Ice Machines

Group 13 Cooling System

PRESSURE WASHING SYSTEM

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

KUFO/SECO DUST COLLECTOR

GLYCOL HEAT EXCHANGE PACKAGE

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000

Models. Options. Standard Features. LoH 2 O

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

ELECTROLUX ELECTRONICALLY CONTROLLED COMPACT SIDE BY SIDE REFRIGERATORS

S-8720-CA-E S-8721-CA-E S-8710-CA-E S-8711-CA-E S-8700-CA-E S-8701-CA-E. Sensorflo Battery Powered Lavatory Faucet MODELS: FEATURES: COMPLIANCE:

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Twin-Agent Fire Fighting/Securing Systems Specifications

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

Boiler Manual. Series 3 Water & steam boilers for use with Gas, Light Oil, & Gas/Light Oil Fired Burners. Maintenance Parts. Installation Startup

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

LIGHTING COMMERCIAL AQUATICS

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

Econoburn Technical Datasheet

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Boiler Start-Up Cycle SYSTEM RETURN

C44A/C44AW DISHWASHER

Professional Plumbing brands you trust.

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

Hydro-Pnuematic Tank Contoller. HTC200 and 300 Series. User Manual

BRAVO! 2-STATION HANDWASH SINK Operations & Maintenance Guide

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Transcription:

SPECIFICATIONS SHELL WEIGHT: 3000 LBS. 10'-11" O.D. 10'-2 1/2" O.D. 8'-6" I.D. 6'-11 1/2" Job #22 WATER WEIGHT: 5656 LBS. TOTAL SHELL & 8656.1 LBS. WATER WEIGHT: WATER VOLUME: 90.7 Cu.Ft. R5'-1 1/4" WATER GALLONS: 678 SURFACE AREA: ICC ES LISTED #: 56.8 SQ. FT. PMG-1161 GAL. Crane Lift Extensions 6 1 2 " 7 1 2 " Crane Lift Extensions WATERPROOF SKID SUPPORT STRUCTURE ATTACHED TO SPA AT NESPA FACTORY LIGHT NICHE *SKIDS SUPPLIED BY NESPA 36 3/4" 4 4 1 " 6" 9" 1' 9" 6" 4 4 1 " 1'-3" 37 1/4" LED LV LIGHT, 12 VOLT, U.L. SIDEWALL SUCTION SIDEWALL SUMP AquaStar WAV9, 9" X 9" Frame, Approved Max Flow Rate: Floor = 316 GPM Wall = 208 GPM Complies w/ ANSI / ASME A112.19.8 & NSF / ANSI 16-2011 7 1 2 " 7 1 2 " 2'-4" Nespa Aquastar Approved Sump IAPMO Approval # SP4900 JET HYDRO INLETS 1-1/2" WATER - 1-1/2" AIR HYDROAIR #10-5100 COMPLIES W/ ANSI CODE ASME A112.19.8-07 UL RETURN INLET FITTINGS 1-1/2" WALL TYPE W/ EYEBALL HYDROAIR #10-3500 COMPLIES W/ ANSI CODE ASME A112.19.8-07 UL FILL INLET FITTINGS 1-1/2" WALL TYPE W/ EYEBALL HYDROAIR #10-3500 COMPLIES W/ ANSI CODE ASME A112.19.8-07 UL original proprietary designs of, 52 1/2" O.D. 40 1/2" 4 1 2 " 7 1 2 " 21 1/2" 19" 10" 8" Waterproof Skid Support Structure attached to spa at Nespa factory 6 1 2 " 71 2 " 9" 2' 4 1 4 " 3/8" = 1' permission to do so by, is illegal. 9/6/2018 10" 23 1/2" 17" 1' 18" 34 1/2" AS-BUILT ALL DIMENSIONS SUBJECT TO 1/4" TOLERANCES 1230 NEPTUNE PAGE 1 OF 9 SD

Job #22 Oceanside Glass and Tile Tourmaline 926-60% Incense Textura 957-40% original proprietary designs of, permission to do so by, is illegal. 5/25/2018 N/A 1230 NEPTUNE PAGE 2 OF 9 Tile

3" TEE > 3in > > 3in > 3" FILTER / EDGE PUMP SUCTION 3" BOOSTER SUCTION 3" TEE original proprietary designs of, 1/2" = 1' permission to do so by, is illegal. 8/17/2018 Suction Plumbing 1230 NEPTUNE PAGE 3 OF 9

> 3in > 3" FILTER RETURN 2" > 1-1/2" WATER FEATURE RETURN 3" BOOSTER RETURN original proprietary designs of, 1/2" = 1' permission to do so by, is illegal. 8/17/2018 Return Plumbing 1230 NEPTUNE PAGE 4 OF 9

1" SPA LIGHT CONDUIT 1" WATER FEATURE LIGHT 1" SPA LIGHT CONDUIT 1" SPA LIGHT CONDUIT original proprietary designs of, 1/2" = 1' permission to do so by, is illegal. 8/17/2018 Spa Lights 1230 NEPTUNE PAGE 5 OF 9

2'-9" (3) - 3" Transfer pipes - Gutter to Surge Tank Overflow Discharge 2-1/2" pipe Surge Tank 6' -1" 4' Depth Equipment to Tank - Edge Pump Suction - 3" Water fill Sensor stilling line - 1" Water Fill - 1" 12' Spa to equipment - Booster Suction 3" Booster Jet returns 3" Filter/ Heat/ edge suction 3" Filter return heat or edge 3" Water feature suction 2" Water feature return 2" Water feature light 1" Spa light - 1" ( qty 4) Valve Box (above waterline) Pipes above waterline- 1. 3 Spa Footwell Lights 2. Fountain Light Pipes up to Pumps 2800 Richter Ave. Suite C Oroville, CA 95966 E-Mail: jim@tiledspas.com Web Site: www.tiledspas.com 1/4" = 1' Spa Layout 1230 NEPTUNE 8/17/2018 PAGE 6 OF 9 original proprietary designs of, such are protected by the copyright laws of the United States permission to do so by, is illegal.

4'-8" 3'-2" Lifting Skid = 7" High 2'-9" Overflow - 2-1/2" 4'-3" 1'-8" 28" 2'-9" 7" 4'-5" 51 1/2" O.D. 18" 4" Lifting Skid = 7" High 1'-9 1/2" 4'-6" original proprietary designs of, 1/4" = 1' permission to do so by, is illegal. 8/20/2018 Plumbing Layout 1230 NEPTUNE PAGE 7 OF 9

Bolt 73" Washer Steel Plate Gasket < 2.5in < < 3in < < 3in < < 3in < 269 GAL. < 1in < < 1in < > 3in > Water fill Sensor Stilling line - 1" Steel Bolt Ring Washer Nut 3/4" 2 1/2" (3) - 3" Transfer pipes - Gutter to Surge Tank - 6" On-Center 2-1/2" Overflow Center - 4" 7 1/2" Water fill line - 1" Edge Pump Suction - 3" 23 1/2" 16" 19 1/2" 12" 1/2" 1" 2" 11" 24" 20" 11" 2" 1" 16" 12" 4" 3" = 1' 52 1/2" 51 1/2" 49 1/4" 43 1/4" > 3in > 2" 47 1/4" 1X4 Tube Steel Ø1/2" 8X 2X6 Tube Steel GASKET 1 4 " Thick original proprietary designs of, 1" = 1' As Noted permission to do so by, is illegal. 8/17/2018 3/8" = 1' AS-BUILT Surge Tank 1230 NEPTUNE PAGE 8 OF 9

Booster Jet Pump Water Feature Pump Valve Spa Suction Valve Surge Tank Valve Jandy 3-way Filter Pump Valve Filter Heater Filter Return Surge Tank Filter Suction Spa Filter Suction Booster Jet Suction Booster Jet Return Water Feature Suction Water Feature Return 4' 4' 2'-4" 2' 10' original proprietary designs of, 3/8" = 1' permission to do so by, is illegal. 5/27/2018 EQ Layout 1230 NEPTUNE PAGE 9 OF 9

3" Booster Jet Return Footwell Light Conduit 3" Booster Suction 3" Filter / Edge Return Basin Suction Gravity Feed (3) Footwell Light Conduit Water Feature Auto Fill 3" Filter / Edge Suction Footwell Light Conduit Center Water Feature Light Conduit Air Venturi Service Fitting Service Fitting original proprietary designs of, permission to do so by, is illegal. 8/20/2018 N/A Plumbing ID 1230 NEPTUNE PAGE 1 OF 1