QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Similar documents
product brochure Sump, Effluent and Sewage Controls

PRODUCT PRICE BOOK January 1, 2019

PRODUCT PRICE BOOK September 4, 2018

PRODUCT PRICE BOOK JUNE 4, 2018

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

We ve Got Panels Under Control.

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

Liquid Level Alarms & Controls

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Serious Products for Serious Contractors! User s Manual

2018 PRICING. alderonind.com STANDARD PRODUCTS

PO Box 827 Hawley, MN (218) Fax (218)

TYPE POS Oil Shield Sump Pump

SIMPLEX WEATHERPROOF CONTROL PANELS

Barnes Oil Sensor Switch

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

1. Read all instructions before proceeding with the installation. Improper installation may void warranties.

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Control Panel with Across The Line Starters

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

2

2

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

PRYCO, INC. FUEL CONTROL

STANCOR Oil-Minder Simplex & Duplex Pump and Control Systems

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

Professional Plumbing brands you trust.

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Specification/ Data Sheet

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

Plumbing Supply Products

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

International Catalog

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Plumbing Supply Products

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

CM800 Emergency Call System

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

SP-1000X. Panic Device Power Controller Installation Guide. Rev

SECTION SANITARY SEWAGE PUMP STATIONS

Mission Critical. Fuel Supply Systems

Safety & Installation Instructions

ion Genesis Pump Controller

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

DE5300 Delayed Egress System. General Information

CHAPTER 20 SERVICE EQUIPMENT

Variable Frequency Drive SERIES MP800 VFD

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

SECTION STEAM CONDENSATE PUMPS

Rack Mount Series Installation Guide

TM Series. Induced Draft, Counter Flow Optional Accessories

Freezers. Laboratory & Plasma. i.series Horizon Series

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Scroll Medical Air Compressor with Premium NFPA Control Panel

Commercial and Light Industrial Fire Alarm Control Panel

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Elevator Sump Kits and Components

RQE Series Temperature Controllers

GRUNDFOS INSTRUCTIONS SLC, DLC. Simplex and Duplex pump control panels. Installation and operating instructions

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

HOT FOOD HUMIDITY CABINET MODEL HFD-3

CONDENSATE MANAGEMENT SYSTEMS

Smart-Wall TV Kit - Installation & Operation Instructions -

Medical Vacuum Systems Product Selection Guide

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

SECTION LOW VOLTAGE LIGHTING CONTROLS

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

American Onsite Products

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Beacon 800 Gas Monitor Operator s Manual

Transcription:

QUICK SHIP Products Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE! www.sjerhombus.com

NEED PRODUCTS IN A HURRY? DON T WORRY! SJE-Rhombus is committed to being the best in the industry. In an effort to serve you better, we offer Quick Ship Products available to ship within one business day at NO ADDITIONAL CHARGE! Motor Contactor Control MODEL 112 SINGLE PHASE SIMPLEX The Model 112 control panel provides a reliable means of controlling one 120, 208, or 240 VAC single phase pump in pump chambers, sump pump basins, irrigation systems and lift stations. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audible/visual alarm system. 1019840 1121W114H17A 120/208/240V, Circuit Breaker, (3) SJE SignalMaster Switches Control panels Plugger Products MODEL 122 SINGLE PHASE DUPLEX The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in pump chambers, sump pump basins, irrigation systems and lift stations. The alternating action equalizes pump wear; and this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. 1019842 1221W114H6A17A 120/208/240V, Circuit Breakers, Aux. Contacts, (3) SJE SignalMaster Switches JB Plugger The JB Plugger system is a NEMA 4X junction box providing a convenient location to connect all wiring required for a typical pumping station installation. It employs a receptacle to accept a 120 VAC or 230 VAC piggy-back plug and a pump plug. It includes a terminal strip to connect an alarm system in the junction box. Package ensures a liquid-tight seal and strain relief for the cable entering the junction box from the pumping station. 1007936 JB Plugger, 120V, Cord Seal, Conduit Hubs, Riser Extension, No Alarm or Floats Ultra Nator The Ultra Nator control and alarm system controls two alternating single phase 120V pumps in duplex pump applications. Plug and play design features fail, high water, horn disable, pump run and power on. Touch pad buttons for alarm test, horn silence, manual pump run, test/reset and battery test function. 9V battery backup for alarm system. (Battery Not Included) 1029624 Ultra Nator, 120V, (2) 10 foot SJE MicroMaster Switches PS Patrol The outdoor rated PS Patrol system features a built-in high water alarm and provides a convenient location to connect all wiring required for a pumping station installation. It employs a receptacle to accept either a 120V or 230V pump and/or piggy-back pump switch. The pull out assembly allows easy wiring; no external cords. Vent holes help prevent moisture condensation inside of post. 2 1022728 PSP120V6H17A 120V, No Pump Switch, SJE SignalMaster Switch

EZ Series EZ Series Simplex The EZ Series Simplex control panel is designed to control one 120, 208, 240 VAC single phase pump in water and sewage installations. The control panel features a display on the inside of the front cover for programming and system monitoring including pump elapsed time (hh:mm) and events. The or demand dose. 1030111 EZS21W114H3A6A8AC10E15A17G 120/208/240V, Locking Latch, Pump & Control/Alarm Circuit Breakers, ETM, Cycle Counter, Aux. Alarm Contacts, (3) SJE MilliAmpMaster Switches EZ Series Plugger Installer Friendly Series The EZ Series Plugger control panel is easy to install and provides convenient installations. The panel includes a built-in high water alarm with test/normal/ silence switch and incorporates a receptacle to accept 120 VAC or 240 VAC pump and piggy-back pump switch. The mounting post (optional) includes an access door and cord seal which allows piggy-back and pump plugs to be easily routed and sealed into the panel. The post can be mounted in the ground directly, over a 4X4, or over conduit. 1032932 EZP11W6C0H10EP17A 120V, Locking Latch, Mounting Post, Alarm Switch, No Pump Switch, SJE Signal Master Switch IFS Single Phase Simplex (Demand/TD) The IFS simplex control panel is designed to control one 120, 208, 240 VAC single phase pump in water and sewage installations. The panel features an easy-to-use touch pad with display on the inner door for programming and system monitoring. Touch pad features: Level Status Indicators, HOA (Hand-Off-Automatic) Buttons, Pump Run Indicator, LED Display. The panel dose or demand dose. Pump ETM and cycle counter. control panels Model 1022726 IFS21W114H8AC17G 120/208/240V, Demand Dose, Display Board, Pump Circuit Breaker, (3) SJE MilliAmpMaster Switches IFS Single Phase Duplex (Demand/TD) The IFS duplex control panel is designed to control two (alternating) 120, 208, 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear and this system provides override control should either pump fail. The panel features an easy-to-use touch pad with display on the inner door for programming and system monitoring. Touch pad features: Level Status Indicators, HOA (Hand-Off-Automatic) Buttons, Pump Run Indicators, Lead/Lag Selector, LED Display. The panel dose or demand dose. Pump ETMS and cycle counters. 1022727 IFS41W114H8AC17G 120/208/240V, Demand Dose, Display Board, Pump Circuit Breakers, (3) SJE MilliAmpMaster Switches 3

Indoor Alarm Tank Alert AB The Tank Alert AB (auto-reset, battery backup) indoor alarm system provides audible/visual warning of threatening liquid level conditions in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural and other waste applications. The horn can be silenced, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. A green Power On light indicates 120 VAC primary power to the alarm. If primary power fails, the alarm system continues to work due to the 9VDC battery backup feature (battery not included). Low battery chirp feature indicates when battery should be replaced. Tank alert alarm systems 1011421 TA AB-01H 120V with 15 SJE SignalMaster High Level Indoor/Outdoor Alarm Tank Alert EZ The indoor/outdoor Tank Alert EZ alarm is easy to install and features an innovative, sleek 2-color molded enclosure which integrates the LED red translucent beacon. The alarm sounds and the upper housing half illuminates when a potentially threatening liquid level condition occurs. The audible alarm can be silenced by pressing the Test/Silence button, but the alarm light will remain on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. A green Power On light indicates power to the alarm panel. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. and external mounting tabs for easy installation. Includes auxiliary alarm contacts for easy attachment of remote devices. Patents Pending 1036592 TAEZ-01HTB 120V, Terminal Block with 15 SJE SignalMaster High Level 4

Control Switches SJE SignalMaster - Mechanical The SJE SignalMaster pump control panels and alarms in potable water, water and sewage applications. The SJE SignalMaster control switch is not sensitive to rotation. This normally open control switch turns on (closes) when the switch tips slightly above horizontal signaling a high level, and turns off (opens) when the switch drops slightly below horizontal. It has a control differential of 1.5 inches (4 cm) above or below horizontal and features a yellow Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water. 1006044 20SGMPCNO 20, Pipe Clamp, Normally Open Sensor Float - Mercury The Sensor Float control panels and alarms in sewage and non-potable water applications. The Sensor Float control switch is not sensitive to rotation and is suitable for use with intrinsically safe circuits. This normally open control switch turns on (closes) when the switch tips slightly above horizontal signaling a high level, and turns off (opens) when the switch drops slightly below horizontal. It has a control differential of.5 inches (1 cm) above or below horizontal. 1002117 15PCNO 15, Pipe Clamp, Normally Open Accessories Float Bracket UL Recognized cord strain relief connectors. 1009432 4 Float Bracket with Mounting Device Cable Weight use of tools. control switches & accessories 1002230 Cable Weight 5

Mechanical Pump Switches SJE PumpMaster The SJE PumpMaster mechanically-activated, wide-angle pump switch is designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC in potable water, water and sewage applications. This pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. It features heavy-duty contacts and adjustable pumping range of 7 to 36 inches (18 to 91 cm). Available with or without piggy-back plug. Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water. 1002715 15PMDP1WP 15, Pump Down, 120V with plug 1002725 15PMUWOP 15, Pump Up, 120/230V without plug SJE PumpMaster Plus The SJE PumpMaster Plus mechanically-activated, wide-angle switch is designed for direct control of pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC in potable water, water, sewage applications. This pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. It also features heavy-duty contacts and adjustable pumping range of 7 to 36 inches (18 to 91 cm). Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water. 1003243 15PMPD1WP 15, Pump Down, 120V with plug Double Float Master The Double Float Master mechanically-activated, wide-angle pump switch is designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC in non-potable water and sewage not sensitive to rotation or turbulence. This switch is voltage sensitive - use with correct voltage. relay eliminates pump chatter in turbulent conditions allowing the pump switch to operate relay control panels for larger pump applications. It features an adjustable pump range of 3 to 48 inches (7.6 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available. 1016864 15DFMMD1WP 15, Pump Down 120V, with plug SJE VerticalMaster The SJE VerticalMaster mechanically-activated pump switch is designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC in non-potable water and sewage laundry trays, as well as in large tanks. The SJE VerticalMaster pump switch is not sensitive to turbulence. It features heavy-duty contacts and adjustable pumping range of.75 to 6.5 inches (2 to 17 cm). 6 1003590 10VM1WP 10, 120V with plug

Mercury Pump Switches Accessories 1008517 2 inch Cord Seal (1-3 Cables) 1037126 2.5 inch Cord Seal (1-6 Cables) Junior Super Single Double Float Cord Seal 1009305 1 inch Hub Assembly 1008848 1.5 inch Hub Assembly 1008849 2 inch Hub Assembly The Junior Super Single mercury-activated, wide-angle pump switch is designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC in non-potable water and sewage applications. Although this switch is not sensitive to rotation, it is affected by turbulence and should be mounted in a non-turbulent location. It features an adjustable pumping range of 6.5 to 19 inches (16.5 to 48 cm). 1001817 15JSD1WP 15, Pump Down, 120V with plug The Double Float mercury-activated, wide-angle pump switch is designed to control pumps up to 15 FLA, 90 LRA, 120 VAC or 240 VAC in non-potable water and sewage applications. It is rotation or turbulence. This switch is voltage sensitive - use with correct voltage. It consists of to function in series. The holding relay eliminates pump chatter in turbulent conditions allowing the pump switch to operate relay control panels for larger pump applications. It features an adjustable pumping range of 1.75 to 48 inches (4.45 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available. 1002022 15DFD1WP 15, Pump Down, 120V with Plug The Cord Seal provides strain relief and a liquid-tight seal. Seals 1-3 cables in a 2 terminal adapters and 1-6 cables in a 2 1/2 terminal adapters. PVC plugs are included (for unused cable positions). Ground wire included. Hub Assembly The Hub Assembly provides liquid-tight conduit attachment location. Available in 1, 1.5, 2 and 1037128 2.5 inch Hub Assembly U.S. Patent Nos. 4,529,854 & 4,572,934 Mercury PUMP switches & accessories 7

Quick Ship products normally ship within one (1) business day from receipt of order (as inventory allows) at no additional charge. Standard lead times may apply to orders combining Quick Ship and Non-Quick Ship products. For list pricing, please see the SJE-Rhombus price book or visit www.sjerhombus.com. 22650 County Highway 6, PO Box 1708 Detroit Lakes, MN 56502 USA Toll Free: 1-888-DIAL-SJE (1-888-342-5753) Phone: 218-847-1317 Fax: 218-847-4617 Email: sje@sjerhombus.com www.sjerhombus.com Follow us on: 2013 SJE-Rhombus Rev 04/13