Wheelock Notification Appliance Mounting Accessories

Similar documents
Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

MOUNTING ACCESSORIES. See Notes 1 & 8. See Note Thickness: 13/64 (A) UNIVERSAL MOUNTING PLATE (F) DOUBLE-GANG, FLUSH (BO) See Notes 4

MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep

s Notification Appliances Mounting Options

UL Online Certifications Directory

Protect. Alert. Inform.

Siemens: Cerberus Division

UL Online Certifications Directory

Wheelock RSS & RSSP Series

XPS and XNAC Installation Instructions

Analog fire panels FPA-1000 Family

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Spark Electrodes/Flame Sensors

Life safety notification

1. POWERPATH Operation

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

*15cd models are Listed at 15cd and meet 75cd on axis

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

FA-101U Fire Alarm Control Panel

DETECT-A-FIRE Heat Detectors

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Vibratone Horns. Models 350 and 450

s Notification Appliances

NBG-12LR and NBG-12LRA

Fire Alarm Control Panels

TrueAlert Notification Appliances

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

Dimensions of the Optional Mounting Box (BB-400R/W)

TrueAlert Addressable Notification Appliances

Silent Knight Device Compatibility

SAFEPATH SAFEPATH. Emergency communications system

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Linear Heat Detection for Coal Conveyors. Application Guide

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual

Conceal-Alarm Series FA100 & FA900. ETL listed to UL standards UL1971, UL1480, UL464

TrueAlert Multi-Candela Notification Appliances

L-Series, Emergency Communication Devices

PFC-3002T Fire Alarm Control Panel

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

AlarmLine Addressable Linear Heat Detector

SECTION FIRE ALARM SYSTEMS

The Advance You ve Been Looking For

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

L-Series, Indoor Strobes and Horn Strobes

Potter Wall Mount Select-A-Strobe

Honeywell Power Products

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

MODELS ASHP, ASHH, ASUP, and ASUH

Vibratone Horns. Models 350 and 450

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

FA-102U Fire Alarm Control Panel

TrueAlert Multi-Candela Notification Appliances

FIRE LINE CARD adiglobal.ca

DONALD H. BERG, ARCHITECT

Figure 1. Figure 2. See notes 1 and 2 below.

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Badger Universal Control Head

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

Cooper Fire Systems. UL Listed Range

'08 Series Notification A liances

Selectable Output Chimes and Chime/Strobes

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Our objective is to deliver quality electrical materials and services to construction and housing projects that are of the highest quality.

LifeAlarm Fire Alarm Controls

SC-6 Six Supervised Control Module

Hazardous Area Ringers & Loudspeakers

TrueAlert ES Addressable Notification Appliances

TrueAlert Addressable Notification

UL Systems. UL intelligent addressable systems Product Name

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

MODELS 304GC, 304GCX, 314GC, and 314GCX

PT700. Product Information

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Fire Alarm Manual Pull Station Wiring Diagram

ULCF3000 ULCF3000RM INSTALLATION MANUAL. Conforms to UL864 9th Edition. Assessed to ISO 9001:2008

EP5 Electropneumatic positioner

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Bravo II. High Performance Multi-Purpose Speaker

Proximity Series. features: specifications: options: in-wall box. what great systems are built on.

SERIES WATTAGE / LAMP POWER SUPPLY VOLTAGE OPTIONS. ET Electronic Transformer. MT Magnetic Transformer. TT Q-Tran Toroidal Transformer

Signature Series Auto-Sync Output Module (CC1S)

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

Hazardous Location Supervised Warning Light

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

TrueAlert Addressable Notification Appliances

TrueAlarm Analog Sensing

TrueAlarm Smoke Detectors

INTELLIKNIGHT 5895XL. Installation and Operations Manual. Intelligent Power Module for the 5820XL Systems. Part Number Rev E

DISCONTINUED PRODUCT. reference publication

Transcription:

Wheelock Notification Appliance Mounting Accessories K-75-008 Effective: April 2016 DESCRIPTION Kidde Fire Systems offers Eaton s Wheelock Notification Appliance Mounting Accessories for use in a large variety of applications. Note: All mounting plates and backboxes must be ordered separately. Select largest backbox shown in mounting options where possible to provide additional room for easy installation. (A) DBB Backbox Standard steel backbox provided with knockouts or interior surface mounting, concealed conduit mounting or semi-flush applications. It is painted to match the signal. Used with RSS, RSSP, 43T, MB, MT 4 Sq. (C) BB Backbox Standard steel backbox with knockouts for interior surface mounting, concealed conduit mounting or semi-flush applications. It is painted to match the signal. Used with RSS, RSSP, 43T, MB Note: When used with AC Horn BB must be used for surface mount. 5 2-3/16 Provided with knockouts for 1/2 & 3/4 conduit Provided with knockouts for 1/2 & 3/4 conduit 4 8 8 8 8 (B) ISP2-R Surface Extender Used with ET, ET70, MT 5-1/4 Sq. 4-5/32 Sq. 3-45/64 29/32 1-3/16

(D) SBB Backbox For surface mounting speakers, chimes, and electronic applications. Used with RSS, RSSP, 43T, MB, E70, MT (F) SFP Semi-Flush Plate Stamped aluminum surface wall plate which mounts behind the basic unit and serves to cover recessed backboxes in semiflush mounting applications. It is painted to match the signal. Used with RSS, RSSP, 43T, MB, E70, E90, ET70, MT 5-9/16 6 Sq. Sq. 5/16 5-1/2 Sq. 3-9/16 3/4 Knockouts (each side) 1/2 Knockouts (each side) (G) AP Adapter Plate Stamped aluminum adapter plate designed for applications where semi-flush installations cannot be used. The plate can be mounted to standard octagon or round backboxes single or double gang boxes or plaster rings. The backbox and basic unit are then fastened to the plate. This type mounting is referred to as a concealed conduit installation. It is painted to match the signal. Used with 43T, MB (E) WBB Weather Resistant Backbox Sturdy die-cast housing, threaded conduit hole and knockout for outdoor applications. It is painted to match the signal. 6 Sq. Sq. 5/16 Used with 43T, MB, RSSWP, MTWP, MT-12/24-R Holes (4) 1/4 Dia. Tapped for 1/2 conduit 5 4-1/8 Sq. 2-1/16 2 1/2 Knockout 1/4-2 -

(H) IOB Backbox For indoor and outdoor surface mount applications. Used with MT, MTWP, ET70WP Note: MT or MTWP strobe are for outdoor mounting. Note: For weatherproof concealed conduit applications also order WP-KIT. (N) SBL-2 Surface Backbox Used with RSS, RSSP, 43T, MB 6-7/64 11/16 Knockouts for 1/2 conduit (top, bottom) 10-15/16 2-5/8 5-21/32 5-1/4 Sq. Sq. (R) WPSBB-R Used with RSSWP 1-11/16 2-5/8 Note: For weatherproof concealed conduit applications also order WP-KIT. 8 8 8 8 1-11/16 5-21/32 (M) SHBB Surface Backbox Used with RSS, RSSP, 43T, MB 2-19/32 1-9/16 11/16 5-3/16 5 Sq. Sq. 1/2 8 8 8 8-3 -

(S) WFP Plate Used with MT, MTWP, ET70WP, RSSWP (U) ESBC Backbox (Order Codes: Red ESBCR, White ESBCW) For indoor surface mounting of Exceder products 11/32 Used with Exceder STC, HSC, HNC 3 Sq. 1-11/16 6.875 2.0 (T) ESB Backbox (Order Codes: Red ESBR, White ESBW) For indoor surface mounting of Exceder products Used with Exceder ST, HS, HN ø6.816 5-3/8 4-3/4 2-1/16 AWG. #18 AWG. #16 AWG. #14 AWG. #12 5-1/8 AWG. #18 AWG. #16 AWG. #14 AWG. #12-4 -

ORDERING INFORMATION Part/Model Number Application Description Designation AP-R 43T, MB Concealed Conduit Plate G BB-R RSS, RSSP, 43T, MB Standard Indoor Backbox C DBB-R RSS, RSSP, 43T, MB, MT Deep Indoor Backbox A ESBR HNR, HSR, HSR-A, STR, STR-A Universal Backbox for Exceder Series, Wall Mount, Red ESBW HNW, HSW, HSW-A, STW, STW-R Universal Backbox for Exceder Series, Wall Mount, White ESBCR HNRC, HSRC Universal Backbox for Exceder Series, Ceiling Mount, Red ESBCW HNRW, HSWC Universal Backbox for Exceder Series, Ceiling Mount, White IOB-R MT, MTWP, ET70WP Indoor/Outdoor Surface Backbox (Surface Mount, Exposed Conduit) T T U U H IOB-R + WP-KIT (order separately) MT, MTWP, ET70WP Indoor/Outdoor Surface Backbox + Weather Proof Kit (Surface Mount, Concealed Conduit) H+WP-KIT ISP2-R ET, ET70, MT Indoor Surface Plate B SBB-R RSS, RSSP, 43T, MB, E70, MT Surface Backbox D SBL2-R RSS, RSSP, 43T, MB Surface Backbox N SFP-R RSS, RSSP, 43T, MB, E70, E90, ET70, MT Semi-Flush Plate F SHBB-R RSS, RSSP, 43T, MB Surface Backbox M WBB-R 43T, MB, RSSWP, MTWP, MT12/24 Weatherproof Backbox E WFP-R MT, MTWP, ET70WP, RSSWP Plate to flush mount weatherproof products S WPSBB-R RSSWP Weatherproof Backbox (Surface Mount, Exposed Conduit) R WPSSB-R + WP-KIT (order separately) RSSWP Weatherproof Backbox + Weather Proof Kit (Surface Mount, Concealed Conduit) R + WP-KIT - 5 -

The technical data contained herein is limited strictly for informational purposes only. Kidde-Fenwal believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. All trademarks are the properties of their respective owners. This literature is provided for informational purposes only. Kidde-Fenwal, Inc. assumes no responsibility for the product s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular question, contact Kidde-Fenwal, Inc., Ashland, MA 01721 USA. K-75-008 Rev AA 2016 Kidde-Fenwal Inc. EXPORT INFORMATION (USA) Jurisdiction: EAR US ECCN: EAR99 400 Main Street Ashland, MA 01721 USA Tel: 508.881.2000 www.kiddefiresystems.com