APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation 24V Independent Audio/Visual Alarm driver Volt free contact outputs Digital display showing gas concentration Serially addressable detector options Battery backup options Optional additional input/output cards Easy installation Modbus Output Option The Tocsin 700 provides ultimate system flexibility for small gas detection systems up to 16 detectors in size. The Tocsin 700 control panel is compatible with the Tocsin 102, 103,103A, 102A and 902 range of Toxic Flammable and detectors and transmitters. To compliment the system a range of accessories, calibration sets and audio visual alarms are available. Power Source 85 to 260 VAC ( 18 to 30 VDC Option) Power Consumption 40 Watts Display 2 x 16 backlight LCD Operating Temperature 0 c to 50 c Operating Humidity Up to 95% non-condensing Resolution 0.00% or ppm Range Dependant Update Rate 1 Second Size (mm) 255 (H) x 265 (W) x 100 (D) Inputs Up to 4 or up to 8 x 4-20mA loops Inputs (Optional) Additional 8 analogue 4-20mA loops 1 x RS485 detector data highway for up to 16 detectors Outputs (Standard) 3 x configurable SP relays (7 Amp non conductive load) 1 x fault SP relays (7 Amp non conductive load) 1 x solid state audio/sounder 24VDC 1 x solid state visual/flasher 24VDC Outputs (Optional) 16 x configurable SP relays (7 Amp non conductive load) 16 x Analogue Outputs (4 per additional card) Optional Equipment Battery backup module 7AH 255 (H) x 265 (W) x 100 (D) CE Declaration EN50081-2: 1994 EN50082-2: 1995 EN61010-1: 2001 Sensors s Options For Flammable Gases Carbon Dioxide Carbon Monoxide Nitric Oxide Nitrogen Dioxide Hydrogen Cyanide Chlorine Hydrogen Sulphide Sulphur Dioxide Hydrogen Chloride 2 SO22 Bramhall Technology Parl Phone Website: : 086-8129925 Ref ROS66
D e t e c t o r C o n t r o l P a n e l D e t e c t o r O p t i o n s For non hazardous area use Tocsin 103 series detectors are available as both 4-20mA analogue or RS485 addressable units. For further information refer to the Tocsin 103 and Tocsin 102 series detector data sheets. 700 Up To 16 Sensors on One addressable Loop Tocsin 102A Flammable Infra-Red Tocsin 102A Flammable Pellistor Tocsin 102A Toxic Gases or Any Tocsin 102 Available with Tocsin 902 Local Display/Controller Any Tocsin 102 Available with Tocsin 902 Local Display/Controller Using 4-20mA Process Output to Tocsin 700 Control Panel. Tocsin 102 Flammable & 2 Infra-Red 4-20mA Tocsin 102 Flammable Pellistor 4-20mA Tocsin 102 Toxic Gases or 4-20mA TES. Basic Tocsin 700 is supplied configured with up to 4, up to 8 or up to 16 detectors. When the RS 485 addressable detector loop is enabled the panel is a Tocsin 700A and can handle up to 16 detectors either as all 16 serially addressable or up to 8 of the channels as 4-20mA analogue with the balance addressable. The system maximum is 16 Detectors. Battery backup and additional I/O modules require an add on accessory housing. For larger addressable systems see the Tocsin 900. 2 SO22 Q Instrument Tel: +44 (0)161 Services 483 1415 Limited, Phone Website: : 086-8129925
D e t e c t o r C o n t r o l P a n e l I / O O p t i o n s S t a n d a r d P a n e l I / O Basic Panel Equipped With 3 Assignable Relay Outputs Dedicated System fault O/P 700 Independent Audio and Visual Alarm Outputs O p t i o n a l I / O M o d u l e s Battery Backup Module P/N 5111401 Internal Sounder Option P/N 5133201 In Out In Out In Out In Out In Out 8 Channel Analogue 4-20mA Input Card. Converts Base Unit To Handle Up To 16 Detectors 8 Channel Relay P/N 5111001 8 Channel Relay P/N 5111001 Volt Free Contacts SP x 8 4 Channel 4-20mA Analogue P/N 5074601 4 Channel 4-20mA Analogue P/N 5074601 P/N 5133001 N o t e s Max 4 Additional Relay s Max 4 Additional Analogue s Additional I/O Modules can be supplied pre installed into the Tocsin 700 Accessory case ready mounted to the Tocsin 700 control panel or separately to allow for inclusion into custom panel builds. Please contact the sales office for further details. 2 SO22 Website: Phone : 086-8129925
SENSOR S OPTIONS O & ACCESSORIES C S E S USING TOCSIN 102 SERIES E S DETECTORS E T Standard Junction Box P/N 5045801 DO T OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT. Ltd 4a Pepper Rd,, EEx d IIC T6 IP66 Rating 6W Max Sira 02ATEX1271X Serial Number 102-xxxxx-2002 0518 0-100 II2GD ppm Available Tocsin 102 Gas Detectors (See Tocsin 102 Data Sheet For Full Details) Tocsin 102 Part Numbers: Flammable Gas MK3 Sensor 4-20mA 5108601 Flammable Gases Infra-Red Point 5107901 Carbon Dioxide Infra-Red Point 5112701 Carbon Monoxide 5107101 Nitric Oxide 5106801 Nitrogen Dioxide 5106301 Hydrogen Cyanide 5107201 Chlorine 5106601 Hydrogen Sulphide 5106501 5107001 5106701 Sulphur Dioxide 5106401 Hydrogen Chloride 5106101 Add Suffix A to Part Numbers To Order an Addressable Gas Detector For Requirements Not Listed Above Contact Sales Collector Cone P/N 401061 Weather Protection Assembly And Test Gas Applicator P/N 401451 Test Gas Applicator/ P/N 401101 Flow Adaptor. Note Fittings For 1/4" Tube 2 SO22 Q Instrument Tel: +44 (0)161 Services 483 1415 Limited, Phone Website: : 086-8129925
SENSOR S OPTIONS O & ACCESSORIES C S E S USING TOCSIN 902 SERIES E S TRANSMITTERS T T R S Tocsin 902 is supplied with its gas detector fitted and calibrated see the table below. For full sensor information please refer to the Tocsin 102 or MKIII data sheet. Fn TOCSIN 902 HAZARDOUS GAS DETECTOR DO T OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT. Ltd 4a Pepper Rd,, EEx d IIC T6 IP66 Rating 6W Max Sira 02ATEX1271X Serial Number 102-xxxxx-2002 0518 0-100 II2GD ppm Available Tocsin 902 Gas Detectors Tocsin 102 Part Numbers: Flammable Gas MK3 Sensor 4-20mA Flammable Gases Infra-Red Point Carbon Dioxide Infra-Red Point Carbon Monoxide Nitric Oxide Nitrogen Dioxide Hydrogen Cyanide Chlorine (Safe Area) Hydrogen Sulphide Sulphur Dioxide Hydrogen Chloride 5111601 5112501 5112601 5111701 5111901 5112701 5112101 5112401 5112001 5112301 5111801 5112201 5112801 For Requirements Not Listed Above Contact Sales Collector Cone P/N 401061 Weather Protection Assembly And Test Gas Applicator P/N 401451 Test Gas Applicator/ P/N 401101 Flow Adaptor. Note Fittings For 1/4" Tube 2 SO22 Phone Website: : 086-8129925
SENSOR S OPTIONS O & ACCESSORIES C S E S USING TOCSIN 103 SERIES E S TRANSMITTERS T T R S Sensor type Flammable Gas MK3 Sensor 4-20mA All Flammable Gases Typically: Basic Part Number Suffix A For Addressable Sensor Min Range Max Range 5129901 A 0-100%LEL Methane Propane n-butane n-pentane n-hexane N-Heptane n-octane Hydrogen Methanol Ethanol Iso Propyl Alchohol Acetone Methyl Ethyl Ketone Benzene Toluene Di-ethyl Ether Cyclohexane Manufactured Pellistors MKIII & Type B Poison Resistant High Reliability Field Proven Flammable Gases Infra-Red Point 5130001 A 0-100%LEL Methane Propane n-butane n-pentane n-hexane Carbon Dioxide Infra-Red Point 5130101 A 0-5000ppm 0-5% Infra Red Gas Detectors Carbon Monoxide 5130201 A 0-50ppm 0-1000ppm Nitric Oxide 5130301 A 0-50ppm 0-500ppm Nitrogen Dioxide 5130401 A 0-10ppm 0-50ppm Chlorine 5130501 A 0-5ppm 0-50ppm Hydrogen Sulphide 5130601 A 0-20ppm 0-200ppm Electrochemical Gas Detectors 5130701 5130801 A A 0-100ppm 0-500ppm 0-500ppm 0-1000ppm 5130901 A 0-5% 0-25% Sulphur Dioxide 5131001 A 0-10ppm 0-100ppm 2 SO22 Phone Website: : 086-8129925