INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

Similar documents
INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Exhaust Air Plenum Heated Supply Air. Direct Impingement Convection Dryer. Heated Drum. Typical Conduction Heating System.

INFRARED HEATERS APPLICATIONS INFRARED HEATING

Ceramic Infrared Heaters

'7 Infrared Drying and Curing Systems w4

CATALYTIC EMITTER - An old idea in new clothes

PHYSICS OF FOIL HEAT GAIN/LOSS IN BUILDINGS

Curing with Electric Infrared

KERONE (AN ISO 9001: 2008 CERTIFIED COMPANY)

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

We offer ceramic radiant heaters and infra-red radiant tubes.

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Infrared Heaters Fast Response Medium Wavelength Infrared Panel Heaters Features: Configurations:

"NP" & "RG" AIRFLO. In-duct firing line burner

Advancement In Coating Curing On Railcars

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Radiant Process Heaters. Gemini. Medium Wave Heaters Twin Bore Quartz Tube Technology

Columbia Boiler Company

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

The Baked Food Company

RADIO FREQUENCY (RF) DRYER APPLICATIONS

INFRARED 101 How Does It Work and Will It Make You Money?

Greater temperature control

Radiant Process Heaters. Gemini. Medium Wave Heaters Twin Bore Quartz Tube Technology

2018 Year 11 Physics Week 8. Thermal Energy Transfer

Gas-Fired Unit Heaters Commercial & Industrial

CATALOG: HVAC - Gas Space Unit Heating

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Heat & Sensor Technology

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Thermal Fluid Heaters

Model 4150 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

Instruction Manual E4 ChamberIR Heater

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Radiant Process Heaters

FLAT FLAME AND EXCESS AIR BURNERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

High efficiency, cast-iron gas boiler

GARAGE / WORKSHOP INFRARED HEATERS

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

Parts List for Ener-Radiant XL Tube Heaters

The ACE Radiant Tube Oven

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Infrared Heaters For Controlled Concentrated Curing

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Cumberland Heating Systems

DIVISION FINNED WATER-TUBE WATER HEATERS

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Specifications of V-Line burners

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

Parts Lists with Exploded Views

Brooders. Better Brooding for Your Chicks... Since 1924

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

ACCELERATE YOUR CURING TIME

? Radiation. Radiation. How does heat energy get from the Sun to the Earth?

A. Product Data: Include rated capacities, furnished specialties and accessories.

Freestanding Ranges FGGF304DL F/ W/ B. 30" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions. Quick Boil Boils water faster.

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

WATER-TUBE POOL HEATERS

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Model 5306 FAST. FOCUSED. CONTROLLED. Infrared Heaters For Controlled Concentrated Heating. Infrared Heat. Instantaneous Results.

INFRARED RADIANT HEATERS

Heat Management Methodology

Installation Instructions U-RAD-LT Electric Radiant Heaters

FINNED WATER-TUBE POOL HEATERS

Gas Built-In Range EW30GS75KS. Featuring Wave-Touch Electronic Controls

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

burner head porting crescents Used on 30" ranges burner head porting crescents 3-1/8" 3-5 8" Used on 30" ranges burner head porting crescents

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

State of the Art. Exceptional Reliability

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)

G, SL & B-Series Old Honeycutt Road, Fuquay-Varina, NC

Freestanding Ranges FGGF301DN F/ W/ B. 30" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

WATER-TUBE POOL HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Freestanding Ranges FGGF301DN F/ W/ B. 30" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

THERMAL PROCESSING THEORY

Heating with Wood. Part 2

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

SECTION GAS-FIRED RADIANT HEATERS

This parts list is current as of the above revision date. See for the current revision.

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

30" GAS FREESTANDING SELF CLEAN CONVECT RANGE (Fingerprint Resistant Stainless Steel) MODELS: MGR8800FZ0 (Stainless)

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Science 7 Chapter 6 Section 1

Transcription:

MODEL: 3207 Revision: 0 BULLETIN 3207 DESCRIPTION The Infra-Red Burner is designed primarily for low temperature industrial process heating where heat transfer in the Infra-Red range is highly effective. The entire top surface of each burner is an Infra-Red generator. Sections are easily coupled together to form continuous lines of radiating surface. Lines of burners may be grouped to form radiating panels of various sizes and shapes. The gas and air mixture burns between the two Inconel screens with the heat of combustion raising the temperature of the screens to the most effective radiating point. Between the two chambers of each Infra-Red Burner is a simple, unique design metering orifice and mixture distributor. The adjustable distributor permits profile or contour heat patterns in any burner grouping. Flame travel from section to section and between limes is instantaneous so that single point ignition and flame failure protection may be applied. Infra-Red Burners are designed to operate with completely aerated mixtures at pressures of 1/2 w. c. or higher. Each section of Infra-Red Burner has two compartments. The lower chamber is the gas-air mixture feed manifold. Mixture pressures may range from 1/2 w. c. to 20 w. c. The upper section of the Infra-Red generator has an expansion chamber, special burner-diffuser screen and radiating screen. Inconel wire is used in both screens for higher heat releases and long life. The two screens are fabricated into one easily removable assembly for cleaning or replacement. 5. 6. 7. 8. 9. 10. 1 1 1 1 15. 16. USES INFRA-RED BURNERS ARE APPLIED TO: Paint and enamel drying. Ink drying. Drying porcelain frits on metals. Over-glaze drying on bisque ware. Core baking - particularly with resin binders. Drying coatings on paper. Railroad car thawing. Die preheating. Preheating of some metals. Drying moving metal strips or sheets. Textile drying, both yarn and woven cloth. Heating plastics for lamination or forming. Curing plastic and plastisole on metals. Skin drying of foundry molds. Other processes requiring temperatures up to 8000F. Area heating. 17700 MILES AVE. CLEVELAND, OHIO 44128 www.pyronics.com PHONE: (216) 662-8800 FAX: (216) 663-8954 marketing@pyronics.com NOTICE: Pyronics practices a policy of continuous improvement in the design of its products. It reserves the right to change the specifcations at any time without prior notice.

PAGE NO. 2 WHAT IS INFRA-RED? Infra-Red energy is electro-magnetic radiation, similar to radio waves, in the spectrum from the highest radar frequencies to visible light. Every object above absolute zero generates Infra- Red waves. Radiant energy travels in the same manner as light waves and is reflected and refracted according to the laws of optics. The radiant energy emitted by a surface depends on the nature of the surface and its temperature. At 600 F all radiation of a body is carried by wavelengths longer than visible red light. At 1300 F a body emits enough visible energy to be selfluminous and appears red hot. Most of energy emitted is still carried by non-visible Infra-Red rays. At 1600 F less than 0.05% of the total energy is in the visible range. Radiation differs from both convection and conduction in that the presence of matter (solid, liquid, or gas) is not required for radiant heat transfer. When a body absorbs radiation, its temperature rises. The medium through which radiant energy travels is not heated. INDUSTRIAL INFRA-RED Many materials used in industrial processes requiring temperatures up to 800 F will absorb heat from Infra-Red radiation sources faster than from convection or conduction sources. The quantity of radiant energy converted into heat depends upon the surface of the material and its reflection characteristics. With materials such as polished metals that are highly reflective, absorbtion of heat by the surface is slight and most of the radiated energy is wasted. On coated objects, the properties of the coating material play a major role in determining the behavior of the object subjected to radiation. If the coating is opaque to Infra-Red, all heat generation occurs near or at the surface and the metal underneath has little to do with the radiation absorbed. In most industrial processes heat is applied to the surface of the object and is then transmitted through the object by conduction. The choice between convection and radiation for heating a surface should be based on the heat absorbing characteristics of the surface. INFRA-RED ABSORBTION All materials exhibit an ability to absorb more energy at some wavelengths of radiation than others. For most industrial heat processing operations, the wavelengths between 2 and 6 microns are most favorable. For maximum heat transfer the Infra-Red generator should be operated so that most of its output energy will fall in the favorable absorption bands. At 1600 F face temperature, the IR series Infra-Red Burners have 92% of the total radiant energy above 0 microns. With face temperatures of 1700 F and higher, more energy falls outside the preferred bands and efficiency of heat transfer is reduced. APPLICATION OF INFRA-RED BURNERS Infra-Red energy waves travel in straight lines from the source. Infra-Red Burners should be mounted so that nearly all energy radiated falls on the surfaces to be heated. The distance between the burners and the absorbing surface should be set to give the desired heat transfer per square foot per unit time with the radiant face at least 2 away. The total heat input requried should be divided into enough sections to provide uniform heat transfer. For those installations where some of the radiant energy will not fall on the work, wing type reflectors of polished aluminum or stainless steel should be installed so that all energy is directed to the work. Infra-Red Burners will convert approximatedly 50% of their input energy into Infra-Red radiation. The balance of the input energy exists in hot flue gases. Drying operations particularly can use this additional convection energy to preheat, increase speeds and reduce heat losses from the work. An oven enclosure or hood will contain the flue gases and provide higher efficiencies. Normal venting practices should be followed for removal of flue gases after they have given up their energy to the work. BURNER SELECTION The ability of a material to absorb Infra-Red energy varies with its surface condition and the material itself. A measure of this ability is the emissivity or absorptivity (listed in standard handbooks) of the material at some preselected temperature. CHART A Chart A shows the Infra-Red transfer rates to be expected at various processing temperatures and absorptivity coefficients. The chart assumes that all of the Infra-Red energy available is directed to the work. The transfer rates should be modified directly by the estimated percentage of actual capture area of the work.

PAGE NO. 3 The total heat required by the process should be divided by the modified transfer rate determined above to find the total Infra-Red Burner area for the installation. EXAMPLE: Dry water from surface of pickled stainless steel strip 3 ft. wide. Water film.003 thick both sides. Strip moving at 100 feet per min. Absorpitivities: water 0.963; stainless steel 0.15. 2 x (0.003 /12 ) x 3 x 100 x 60 x 65#/cu. ft. x 1110 BTU/# = 620,000 BTU/hr. to evaporate water. Since absorptivity of stainless steel is so low, little heat will be absorbed. Thus, it may be neglected in calculations. Opposite 0.96 and 200 F line, read 31, 400 BTU/hr./sq. ft. of radiant surface. With Infra-Red Burners spaced 4 away from the moving sheet, a 80% view factor may be assumed. Actual radiant transfer is then 31, 400 x 0.8 = 25, 200 BTU/hr./sq. ft. which is equal to 25 sq. ft. of Infra-Red Burner. One half or 15 sq. ft. should be installed on each side of the stainless steel strip. BURNER DATA (Select Sections to Match Total Area Required) INFRA-RED BURNER RADIANT SURFACE BTU/HR INPUT PER CATALOG NUMBER WIDTH X LENGTH SQ. FT. AREA SECTION 46IR Straight 4" x 6" 1/6 10,000 412IR Straight 4" x 12" 1/3 20,000 412IRB-8 Bottom Inlet 4" x 12" 1/3 20,000 418IR 4" x 18" 1/2 30,000 412IRB-F Bottom Inlet Flanged 4" x 12" 1/3 20,000 418 IRB-8 Bottom Inlet 4" x 18" 1/2 30,000 NORMAL MIXTURE PRESSURE DEVELOPED AT VARIOUS AIR PRESSURES AIR PRESSURE AT MIXER OUNCES/SQ. IN. 2 4 6 8 10 12 16 MIXTURE PRESSURE INCHES W. C. 1 2 3 4 5 6 8 INLET CATALOG NUMBER & SIZE MAXIMUM INLET FEED CAPACITIES (Select Number of Inlets to Match Mixture Pressure and Total Area) SQUARE FEET OF RADIANT SURFACE AT VARIOUS MIXTURE PRESSURES IN INCHES W. C..5" 2" 4" 6" 8" IRP-3 0.2 0.3 0.4 0.5 0.7 End Plate with 3/8" NPT Tap IRP-4 0.3 0.5 0.7 0.9 1 End Plate with 1/2" NPT Tap IRP-6 0.5 1 3 6 9 End Plate with 3/4" NPT Tap IRP-8 0.8 5 2 5 3 End Plate with 1" NPT Tap IRF-16 3 6 8 10 12 Inlet Flange 2" NPT IRP-B - - - - - Blank End Plate NOTE: Each Burner Section, Flange, and Plate Includes Necessary Gaskets, Bolts, Nuts and Lockwashers for Assembly. 17700 MILES AVE. CLEVELAND, OHIO 44128 www.pyronics.com PHONE: (216) 662-8800 FAX: (216) 663-8954 marketing@pyronics.com NOTICE: Pyronics practices a policy of continuous improvement in the design of its products. It reserves the right to change the specifcations at any time without prior notice.

PAGE NO. 4 DIMENSIONS Approx. Distributor Adjustment Model No. A NPT B C D Mixture 46 IR --- --- 6 5-3/4 46 IR 412 IR 418 IR Pressure 412 IR --- --- 2" W. C. 2/3 turn 1-1/3 turn 2 turns 412 IR-8 1" 1-1/4" 12 11-3/4 4" W. C. 1/4 turn 1/2 turn 1 turn 412 IR-F --- 1-3/16" 6" W. C. 1/6 turn 3/8 turn 3/4 turn 418 IR --- --- 8" W. C. 1/8 turn 1/4 turn 5/8 turn 418 IR-8 1" 1-1/4" 18 17-3/4 Model No. IRP-B IRP-3 IRP-4 IRP-6 IRP-8 "A" INLET NONE 3/8" N.P.T. 1/2" N.P.T. 3/4" N.P.T. 1" N.P.T.

PAGE NO. 5 IR OPTIONS NOTE: SEE BULLETIN 3210 FOR IR REPAIR KITS Quantity and catalog number of sections required. Specify mixture pressure to be used with burners. Quantity and catalog number of inlet pieces. Quantity of #IRP Blank End Plates required. ORDERING INFORMATION Specify quantity of pilot brackets and #2 PBYS Pilots required. Catalog numbers of Mixers and Zero Governers. Combustion Air Blower (voltage, phase, frequency). Specify other controls, etc.