Infrared Single Light Barrier. Mounting Instructions DO560

Similar documents
INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

INFRARED MODULATED BARRIERS

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

English. Series. Installation and Use Manual

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Viewguard Motion detctors PIR and DUAL detectors

Topscan G3 Presence detector for automatic doors

Wind Alarm Instrument x.x0x

Class 1 laser beam sensor safe for your eyes

Silicon UVAB Sensor E xxx

UV Flame Supervision System

INDEX. Installation recommendation

Class 1 laser beam sensor safe for your eyes

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

D-Tect 2 GJD300 Quad PIR Movement Detector

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

Twin Photobeam Detectors Manual

Description. Optex Incorporated

FSLIMPRO

Laser Distance Sensor Type M Analog-Output

RS Pro Infrared Temperature Sensor

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

Class 1 laser beam sensor safe for your eyes

Snifter ATEX22 VERSION. User Manual. Distributor

CONFIGURATION OF THE OPTICALS

Long-Range Barrier Sensors

DUAL OPTIC. Installation manual

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Installation and Operation Manual

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Fireray 2000 Linear Smoke Detector

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Table of Contents. 1. Mounting Tips... 2

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

P E R I M E T E R m i n i c a t a l o g u e

Silicon Pyranometer GSM xx

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Photoelectric Beam Detector

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Movement Detector GJD 300

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Rules for Intruder Alarm Systems

FIRERAY 5000 range USER GUIDE

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

Active Infrared Multi Beam Sensors

Retroreflective sensor with polarization filter

Active Infrared Multi Beam Sensors. R Series

/ / 2018

QRA10... QRA53... QRA55...

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

SIMRAD GD10PE IR GAS DETECTOR

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

Retroreflective sensor with polarization filter

EWP2WIRELESS MOTION DETECTOR

Infrared Flame Detectors

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

E3M-V. Mark Sensor. Applications

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Control and Indicating Equipment

IR FLAME DETECTOR RIV-601/F

Wireless Alarm system s manual

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Downlight ENCORE DL6 15W 2700K

FLAME AMPLIFIER MODULE 3001D

Original operating instructions Safety switch with guard locking AC901S AC902S

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

SERIES 4000 AUTO GATE MANUAL

Wind Alarm Instrument

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

COMPACT FLAME CONTROLLER CFC 1000

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

INDEX. Installation recommendation

Installation manual SP3

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

CA60Plus. Installation manual

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Room Temperature Sensors

Transcription:

Infrared Single Light Barrier VdS-Approval No. G197078 Mounting Instructions DO560 WANING-Opto-Elektronik GmbH & Co Produktions KG Daimlerstraße 13 63303 Dreieich

Planning able of Contents DECLAAION OF CONFOMIY... 1 1 GENEAL INFOMAION... 2 1.1 Functioning... 2 1.2 Features... 2 1.3 Monitoring range... 2 2 PLANNING... 3 2.1 Effective range... 3 2.2 Optical Adjustment range... 3 2.3 Alarm Evaluation... 3 2.4 Extension possibilities... 4 2.4.1 Armed/Disarmed... 4 2.4.2 Alarm memory... 4 2.4.3 Disqualification... 4 2.5 Heater... 4 2.6 echnical Alarm... 4 3 INSALLAION... 5 3.1 VdS-Installation... 5 3.2 Wiring of the equipment... 5 3.2.1 Wiring diagram... 6 3.3 Installation of the equipment... 6 3.4 Mounting with moulded columns...7 3.4.1 Ground-plate... 7 3.4.2 Mounting of moulded columns... 7 4 ALIGNMEN... 8 5 PUING INO OPEAION... 9 6 COMPLEION WOK... 10 7 MAINENANCE... 10 8 APPENDIX... 10 8.1 echnical data... 10 8.1.1 ransmitter/eceiver... 10 8.1.2 B-board... 11 8.1.3 Moulded columns... 11 8.2 Error Elimination... 11 Declaration of Conformity It is herewith certified that the following product: Active Infrared Barrier as a single unit or to be installed in moulded columns consisting of : transmitter, receiver and B-board with Alarm memory and/or disqualification as single unit or transmitter, receiver and B-board with Alarm memory and/or disqualification as moulded column meets the essential protection standards according to the guidelines of the Council for harmonisation Standards within the EEC about electromagnetic compatibility EMV (89/336/EWG) as required. he following standards for the product s judgement with regard to electromagnetic compatibility (EMV) were drawn upon: 1. EN50082-2 Immunity 2. EN50081-2 Emissions 1 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG

General Information 1 General Information 1.1 Functioning Every Active Infrared Barrier consists of one I-ransmitter/I-eceiver. For to allow trouble-free monitoring disturbing influences from outside, for instance caused by sunlight or outside light, must be filtered out. his is effected by a special receiver circuit which is insensitive to direct sunlight radiation. In order to reach higher functioning security the transmitter is triggered by the receiver through a digital reference cable. An evaluation of the I-beam can only be carried out provided that the I-beam is running with the reference impulse at the same time. Extension possibilities for the Infrared Barrier he receiver can be extended by various options. herefore an additional PC (B-board) must be installed in the receiver: Alarm memory for identification of the detector armed/disarmed control input to erase blocking of the memory disqualification in case of decreasing sight distance for instance caused by severe snowfall or fog lens heater, in order to prevent thawing of the optical equipment in case of quickly changing temperatures 1.2 Features his infrared barriers which the alarm response sensibility will be modified by jumpers, can carry just B-boards and the alignment tool, with the extension N in their identification number. insensitive to direct sunlight radiation long distance ranges indoors and outdoors potential-free alarm output adjustable alarm technical alarm in case of function error reduced transmitting power at short distance ranges high EMV-resistance simple instalment and alignment as individual unit for wall mounting or as pillar-mounted unit in moulded columns weather- and corrosion-proof casing VdS admitted, no. G197078 1.3 Monitoring range he linear range is monitored between the transmitter and receiver. An alarm will be released only when the I-beam has been interrupted completely. Alarm Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG 2

Planning 2 Planning he following devices are suitable for to build up trap securities and light curtains. A B A B trap monitoring A B light curtain with 2 beams light curtain with 4 beams In case of planning kindly note the following: do not exceed the recommended distance range free sight distance communication between transmitter and receiver optimal alignment of transmitter and receiver use only shielded cables twisted together in pairs avoid double exposure of one receiver caused by several transmitters mounting of the equipment on solid ground provide adequate number of wire leads 2.1 Effective range I-radius / m 1,5 1,0 0,5 0 25 50 75 effective range 100 Distance / m he I-beam appears cone-shaped from the transmitter into direction of the receiver and reaches a dia. of 2.1. he following table is showing the relation between distance and diameter of the I-beam. Distance/m 1 2 3 4 5 10 20 30 40 50 60 70 80 90 100 I-beam/m 0,04 0,07 0,11 0,15 0,18 0,37 0,73 1,1 1,47 1,83 2,2 2,57 2,93 3,3 3,66 2.2 Optical Adjustment range For alignment the mirrors at the devices can be adjusted horizontally around ±95 and vertically ±10. hus putting the devices (transmitter and receiver) on an axial beam becomes unnecessary. ±10 ±95 horizontal alignment vertical alignment 2.3 Alarm Evaluation An alarm message is output via a potential-free relay contact (NO-COM). he single receivers only release when the I-beam has been completely interrupted. he alarm relay, however, falls of f for the time of the interruption, at least however, for 5 sec. Due to the alarm response time which can be adjusted individually at the receivers no false alarms caused by small animals or falling leaves are possible. (see 5 putting into operation) unning - 20ms walk - 100ms slow walk - 300ms 3 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG

Planning 2.4 Extension possibilities he following options are available for supplementary instalment of a B-board: lens heater for transmitter and receiver B-PC with alarm memory and armed/disarmed control input B-PC with alarm memory, armed/disarmed control input, disqualification and lens heater for receiver further lens heater for transmitter 2.4.1 Armed/Disarmed he armed/disarmed control input serves for deleting and/or blocking the Alarm memory. By selecting armed/disarmed the Alarm memory is blocked. he memory is set as soon as during an armed period a beam is interrupted. 2.4.2 Alarm memory he Alarm memory is activated as soon as during an armed period a beam is interrupted (indicated by red LED on the B-board). For remote display an open collector output towards minus is available. 2.4.3 Disqualification In case of slow reduction of the I intensity at the receiver, for instance caused by severe upcoming fog, snow, dirtying of the lens system or mechanical changes the disqualification evaluation system becomes activated (indicated by yellow LED on the B-board). For remote display an open collector output towards minus is available. he time interval until the release of a disqualification can be adjusted optionally on the B-board between 5 and 30 seconds. During all this time the receiving amplitude of the I beam must be under a defined level. If this level is exceeded only for a short instant, the time starts running again. he alarm output can, as an option, be suppressed during disqualification. (see 5 putting into operation) 2.5 Heater o prevent the optical devices from dewing when applied outdoors or in areas exposed to sudden climate changes, transmitters and receivers must, by all means, be equipped with lens heaters. hose are to be inserted at the transmitters and receivers between lens and electronic board and must be fixed by a screw at the housing s subsoil. Finally a foil is bend carefully around the lens and then clamped between housing and PC board. he heaters are controlled thermostatically and run by separate current supply 12 V AC or DC voltage (see 3.2 wiring of the devices). For outdoor application with moulded columns at least one pillar heater per m column above the ground must be considered. 2.6 echnical Alarm he message of echnical Alarm is transmitted when the program processing unit has recognised an error or when it fails due to external disturbances. Such message can be connected via an open collector output (towards minus) and collected at the receiver board. Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG 4

Installation 3 Installation Installation procedure 1. For installation within moulded columns first of all prepare ground plate and moulded columns (see 3.4 installation with moulded columns) 2. For outdoor application install B-boards and heaters inside of the equipment (see 2.5 heaters) 3. Install the equipment at provided installation position (see 3.3 installation of the equipment) 4. Wire the equipment (see 3.2 wiring of the equipment) 5. Align transmitter and receiver (see 4 alignment) 6. Configuration of the system (see 5 putting into operation) 7. Check up system s functioning (see 6 completion work) 3.1 VdS-Installation he following has to be considered for the installation of a VdS-equipment: 1. he VdS-approval is only valid for indoor application 2. he alarm response time is to fix to 20 ms and not allowed to be altered 3. Never use a disqualification circuit when VdS is applied 4. Never use a heater for VdS application 5. Use only shielded cables with twisted pairs 6. he shielding of the supply line between transmitter and receiver are connected with minus potential on both sides 7. he shielding of the supply line to the central control unit must be connected with ground potential 8. he housings are to be connected with ground potential 9. For intended drilling work at moulded columns the devices have to be removed completely 10. After fixing seal screws either with adhesive lead or lead wire 11. For installation of moulded columns they have to be equipped with cover contact 12. he jumpers at the transmitter and receiver are to be plugged in (pre-adjustment) according to 5 putting into operation 13. Never apply any surface mirror at VdS-operation 3.2 Wiring of the equipment Use only shielded cables with twisted pairs. he shields of the supply lines are to be connected as described under VdS-application 3.2.1 wiring diagram. ransmitter 1 + / operating voltage 2 - / operating voltage 3 vacant (for shield, with connected) 4 sabotage (only for single devices) 5 sabotage (only for single devices) 6 vacant (for closing resistance) 7 reference eceiver 1 2 3 4 5 6 7 8 9 10 11 + / operating voltage - / operating voltage vacant (for shield, with - connected) sabotage (only for single devices) sabotage (only for single devices) vacant (for closing resistance) reference NO COM vacant (for closing resistance) technical interference he sabotage contact of moulded columns is not brought out (the clamps 4 and 5 at receiver and transmitter are not occupied). 5 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG

Installation B-board for receiver 5 Heater 12V AC/DC 4 Heater 12V AC/DC 3 Armed/Disarmed 2 Disqualification 1 Alarm memory A connection for the heater is only available at the B-board provided that it has been equipped with a disqualification. heaterboard for transmitter/receiver 2 Heater 12V AC/DC 1 Heater 12V AC/DC he heating board can be installed in both the transmitter and receiver. 3.2.1 Wiring diagram ransmitter eceiver ransmitter/eceiver + - S Connection for screen (clamp 3) 3. screen (connected internally with - Connection for earth potential Screen on both sides to be connected with - 2. Screen to be connected with earth potential 1. distributor to transmitter to central control unit to receiver o central control unit screen survey of wiring diagram distributor connection to supply voltage and screening he following items must be considered for the wiring of a VdS-installation: 1. Connect screen of the supply line leading to the distributor with earth potential. 2. he screen of the supply lines must be connected from the distributor to the devices from both sides with minus potential. Never connect the screen with earth potential. 3. he housings are to be connected with earth potential. 4. No signals are allowed to be transmitted over the screens. When inductive load is required at the output an additional protecting circuit must be provided i.e. Ccomponent or diode. 3.3 Installation of the equipment he devices are to be installed on a solid foundation in vertical order. he swivelling optic reduces the necessity of putting the devices on a common optical axis. For to open the single units untie the screws at the housing ends and remove the cover carefully. When closing the devices put on the cover carefully and fasten screws carefully again. Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG 6

Installation 3.4 Mounting with moulded columns 3.4.1 Ground-plate Weather influences could effect movements of the ground-plate. herefore they have to be fixed on a stable and solid mounting surface. hus, the ground-plate needs stationary connection. Please pay attention to the position of the cable inlet to the ground-plate. Ground-plate 350 Concrete anhor 600 (800) 800 Concrete anchor B25 600 (800) Column s height Fundament surface up to 2m (600 x 600) mm up to 2m (800 x 800) mm minimum size of the concrete fundament he minimum size of the concrete fundament is depending on the moulded column s height. For moulded columns up to 2 m the fundament s surface must be (60x60) cm at least. In case of moulded columns exceeding 2 m the fundament surface must be at least (80x80) cm. he fixing of the ground-plates on the concrete fundament is effected by means of 4 heavy-duty bolts (providing moulded column heights up to 2 m, length 140 mm, M16) or via 2 concrete anchors (for moulded columns exceeding 2, minimum depth 350 mm, dia. 16 mm). 3.4.2 Mounting of moulded columns For the mounting of moulded columns on ground-plates the moulded columns need to be pre-drilled depending on the drillings on the ground-plate. Please watch the specified maximum lengths of the moulded columns (max. length 1.5 m or 3.0 m, each depending on the ground-plate to be used). For the mounting of moulded columns at walls, at the mounting side a distance of approx. 4 mm for the roof has to be considered. Provided that the moulded columns are to be mounted inside of buildings a base-plate can be used instead of the roof which does not require any distance. he roof and the base cover can be secured by a cover contact. For this purpose the cover contact must be inserted either at the upper or lower end of the moulded column and then to be locked. he transmitter and receiver are to be inserted in the moulded columns at the head and will be adjusted to desired height through the screws at the upper and lower end of the housing. Before installation, please check the cable laying inside of the moulded columns. Devices and moulded columns which had already been pre-wired and checked in the laboratory facilitate installation. hus, only the earth cable needs to be connected on site. 7 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG

Alignment 4 Alignment A red LED has been attached as auxiliary alignment to the receiver which extinguishes by incident I beam. For alignment the mirrors can be adjusted horizontally approx. ±95 and vertically ±10. During the alignment procedure they have to be moved very carefully and sensitively. Luminous spot For pre-alignment of the transmitter and receiver an ordinary light source (alignment searchlight or incandescent bulb) can be applied. herefore the light-source is fixed at the receiver res. transmitter at the same level of the mirror and directed to the opposite side. Now the mirror at the transmitter and/or receiver can be displaced until the light-beam bundled through the lens (appearing as luminous spot on the yellow surface) arrives exactly in the middle of the I-transmitter and/or I-receiver diode. I-transmitter diode incorrect alignment alignment via alignment searchlight correct alignment For precision alignment of the receiver the alignment control device (available as accessory in a grey coloured boxing)or an oscilloscope can be adapted to the test points (signal and GND) provided therefore. he alignment correct as soon as a maximum of LED s appears on the alignment control unit. 1 2 3 4 5 6 7 8 Alignment control unit LED-indicator Evaluation of alignment indicator 1 LED insufficient incident I-energy (re-adjust transmitter) 2-3 LED barely sufficient I-energy 4-5 LED well-sufficient I-energy 6-8 LED excellent I-energy GND J3 test point for alignment control unit resp. oscilloscope SIG Jumper for alignment of alarm response sensitivity alignment with oscilloscope alignment oscilloscope 2V DC / 100us he alignment can also be checked by means of oscilloscope which must be connected to the receiver at the test point (SIG) and minus potential (GND). he number of impulses on the oscilloscope is corresponding with the number of LED s on the alignment checking device. Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG 8

Appendix 5 Putting into operation Device board jumper jumper plugged in jumper unplugged housing is connected to minus potential (*) housing is not connected to minus potential (*)(when VdS is applied alteration is not allowed) GND transmitter J3 SIG max. transmitting power (at medium and long distances) housing is connected to minus potential (*) reduced transmitting power (at short distances) housing is not connected to minus potential (*)(when VdS is applied alteration is not allowed) receiver / J3 alarm response time (see table below) alarm response time (see table below) jumper on pos. 2-3 jumper on pos. 1-2 DQ memory no alarm at DQ alarm at DQ DQ-alarm response time 5 sec. DQ-alarm response time 30 sec. 1 2 3 B-board Adjustment receiver J3 J3 J3 J3 alarm response time adjustments are only valid for B-boards with disqualification and Alarm memory (not for VdSapplication) 20ms pre-setting must not be changed in VdS applications 150ms 50ms 300ms explanation: jumper plugged in jumper unplugged (*) If disturbances should occur during outdoor application plug in jumper to transmitter and receiver. 9 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG

Appendix 6 Completion work Before switching on the equipment make sure that the following conditions are fulfilled: adjustments at the receiver are all correct optimum alignment of transmitter and receiver are all cables tight in the connecting terminal check voltage supply at transmitter and receiver in case of beam interruption LED must light up at the receiver and the alarm relay must be released for 5 sec. at least check sabotage line, when cover has been removed sabotage line must response attach cable release to the cable set up cover and tighten screws for VdS-applications screws must be fixed either with adhesive lead or lead wire 7 Maintenance It is recommended to open the device once a year in order to check its general condition or if there are any damages. When the optic is dirty it can be removed by a anti-static tissue. Use only mild detergents. Please recheck alignment after cleaning procedure. 8 Appendix 8.1 echnical data 8.1.1 ransmitter/eceiver single unit operating voltage 10-18V DC max. waviness 2Vss current consumption 50mA ea. pair range Indoor 160 m Outdoor 100 m moulded column elapse time 10sek. alarm output Potential-free relay contact Max. load 200 V DC, 0.5 A,. max. circuit breaking capacity 10W alarm response time 20 / 50 / 150 / 300ms, at coding plug adjustable to receiver, at VdS-application fixed setting to 20ms operating lag 5sek. technical alarm Electronic exit, open-collector against minus, max. load 12 V DC, 50 ma operating lag approx. 1.5 sec. tamper Potential-free switch contact Max. load 100V DC, 0.2 A infrared beam Wave length 940nm I-impulse length 20us Keying ratio 1:400 Beam width 2,1 alignment angle Horizontal ±95 Vertical ±10 environment class II, acc. to VdS 2110 operating temperature -5 C - +55 C -30 C - +55 C, with heaters air humidity 98% housing Die cast aluminium housing acc. to DIN 1725, black, alloy GD-Al Si, I exit through black Plexiglas window Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG 10

Appendix dimensions (173 x 60 x 60) mm (173 x 60 x 55) mm protection class IP54 IP44 with pillar weight 1,0kg 0,7kg 8.1.2 B-board With Alarm memory with Alarm memory and disqualification Alarm memory Electronic exit, open-collector against minus Max. load 12V DC, 50mA disqualification electronic exit, open collector against minus max. load 12V DC, 50mA response time 5 or 30 sec. adjustable armed/disarmed Armed < 1,5V disarmed 3,5V - Ub heater foil heating element thermostatically controlled 12V AC or DC, 160 ma 8.1.3 Moulded columns moulded column moulded column with one beam direction moulded column with 3 beam directions basic area (70 x 85) mm (86 x 100) mm length ea. Length up to max. 6 m material moulded column made of anodised aluminium, black, cover pane and base cover aluminium cast, cover panes made of Plexiglas protection class IP44 cover protection potential-free switch contact, max. load 100V DC, 200 ma, available as accessory surmount protection potential-free switch contact, max. load 100V DC, 200mA, available as accessory 8.2 Error Elimination error reason LED at receiver is always illuminated check voltage supply at transmitter check alignment insufficient alignment signal check if sight distance communication between transmitter and receiver partly blocked check if optic of the equipment is dirty new alignment of transmitter and receiver frequent false alarms or permanent alarm check if distance communication between transmitter and receiver is partly blocked check if optic of the equipment is dirty check wiring check heaters new alignment of transmitter and receiver equipment cannot be disarmed check alignment check alarm relay check wiring no alarm check alarm relay check wiring 11 Copyright 1996 WANING-Opto-Elektronik GmbH & Co Produktions KG