Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation.

Similar documents
CAPITAL CONTROLS SERIES 480

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Section K CHLORINATION EQUIPMENT

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

PRODUCT LINE. Highest Quality, Best Service


Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Electrochemical Chlorine Sensor Module Addition or Replacement Series 1610B And 1620B

HIGH CAPACITY PRODUCT LINE

HIGH CAPACITY PRODUCT LINE

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Choosing the Right Pump

Sewage Treatment Plants. VTP Series Built-in Vacuum System

J-PRESS SIDEBAR FILTER PRESS

Acrison. Model 515 Polyelectrolyte Preparation Module. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

Pipeline. Medical Gas Pipeline Products

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SEMI-GAS Centurion TM Gas Source Panels/Manifolds

SVENMIX.D DRY POLYMER MIXING SYSTEM

TOTALPAC2 Integrated Fire Protection System

TECHNICAL. Series 18. Pump Packages

Williams & Davis Boilers

Instruction Manual Vaporizer for Chlorine or Sulfur Dioxide Series VAX4600

HYDRO-GUARD HG-1-BASIC/S ATMOSPEHERIC DISCHARGE DEVICE CONSTRUCTION FOR ABOVE GROUND INSTALLATIONS 1. GENERAL DESCRIPTION 2.

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association)

Pipeline. Medical Gas Pipeline Products

Komline-Sanderson Paddle Dryer. Drying technology for biosolids, sludges and by-products

FILTER PRESS TECHNOLOGY HIGH PERFORMANCE DEWATERING APPLICATIONS FOR MINING

SYSTEMS for CATALYTIC FILTERS

GOLF TECHNICAL BULLETIN

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

LBC MANUFACTURING Simple Solutions for Effluent Disinfection

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

Instruction Manual Series 1650/1660 Gas Detector Sensor CAPITAL CONTROLS

Acrison. Polymair. Model 500 Polyelectrolyte Preparation System. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Silhouette. Feedwater Heater. Boiler Feedwater

Williams & Davis Boilers

The iqe Boiler Range. Combination and System T Boilers.

EIMCO Clarifiers... Customized Designs to Match Unique Specifications Most standard or special sedimentation/clarification requirements can be accommo

NEOTeCHA Reactor Sampling Type PV

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

Prepared by Technical Team

BIOSOLIDS DRYER SYSTEM

PUMPS AND PROP AGITATORS

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

¼ Dosing and Transfer Pump. Same Great Name. Revolutionary New Design.

Custom Duct Heaters. Special Applications

DRINKING WATER WORKS PERMIT

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

MECHANICAL. Product Index Mechanical Product Index

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Blowers. Side channel compressors and vacuum pumps. Your Choice, Our Commitment

SECTION DOMESTIC WATER PIPING SPECIALTIES

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

Auto Technology Company Cyclic Corrosion Test Chamber

Alfa Laval spiral heat exchangers

SIMPLEX WEATHERPROOF CONTROL PANELS

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

MDX² INSTALLATION MANUAL

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

IN THE PULP AND PAPER INDUSTRY

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

BERMAD Fire Protection

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

USER S INFORMATION MANUAL

Duct smoke housings, 4-wire D341/D341P and D342/D342P

MODEL MW200 MODEL MW600 AIR DRYER

WD7664 / WD7663 Maxon Burner. Ellis Whisper Dryer Installation & Start UP

Excellence through Versatility

MS SERIES ROLL COMPACTORS

Custom Duct Heaters. Special Applications

STEAM TRAPS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Full-line Product Overview

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

FOB THIRD-GENERATION BENCH-TOP SATURATED-STEAM STERILIZERS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

APC BC300 Series 40kW 208/450/480V User Guide

User s Information Manual

Condensing Unit Installation and Operating Instructions

Progressive Cavity Sewer Systems

Open Charter Magnet School Water Retention System OPERATION, MAINTENANCE & INSPECTION SUPPLEMENT October 20, 2007 Richard Haimann, P.E.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

D R Y P O L Y M E R P R O C E S S I N G NORCHEM

Installation and Maintenance Guide

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Transcription:

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation. The Capital Controls Series 480 all-vacuum gas feeder is designed for direct mounting to a 150 pound gas cylinder or ton container. It is a basic alternative for those applications requiring a chlorine feed rate of 250 PPD (5 kg/h) or less. The gas feed rate is controlled under sonic flow conditions eliminating the need for an auxiliary differential pressure regulators. Multiple feed points can be fed using one feeder by utilizing additional remote meters and corresponding ejectors. A variety of different ejectors are available to meet specific hydraulic requirements. Safe and reliable all-vacuum operation Superior materials of construction for wet or dry gas service Safe integral venting system Six capacities up to 250 PPD (5 kg/h) Solid silver rate and inlet valves Direct cylinder mounted Replaceable inlet capsule Remote metering available Optional switchover capability with automatic reset for uninterrupted service WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Capital Controls Series 480 Easy to install, for indoor or outdoor installation, each Series 480 chlorinator is factory tested and needs no field adjustment prior to start-up. Five different flowmeter capacities provide versatility in meeting gas flow requirements. Chlorinators mount directly on the gas valve of a cylinder or ton container, utilizing a lead gasketed positive yoke clamp. Diaphragm ejectors are standard with a choice of diffuser outlets. A Series 480 chlorinator consists of a vacuum regulator, ejector or chemical induction unit and vacuum and vent tubing to make a complete system. If multiple feed points are required, remote meter panels and additional ejectors are provided. A variety of ejectors are available to meet your application needs. A switchover module is offered to provide for uninterrupted service. Design Features Sonic Flow: Gas flows at sonic velocity maintaining constant gas flow; additional pressure regulation is not required Automatic Switchover: A separate, independent device that does not require manual reset. Flow indication is available at both vacuum regulators. Each vacuum regulator has a separate independent vent and an integral pressure relief check valve Reliable: Over 35 years of experience with all-vacuum operation, loss of chlorine supply indicator, integral venting system, main regulating diaphragm, integral gas flow indicator Ease of maintenance: Simplicity of design and modularized components; such as the replaceable inlet capsule for minimized maintenance Superior materials of construction: Solid silver rate valve, corrosion resistant yoke assembly, tantalum springs Applications For process water, waste treatment and water treatment in the municipal or industrial marketplace: Potable water disinfection, well water, surface water treatment facilities Slime and algae control: irrigation systems, cooling towers, rechlorination points, remote systems Wastewater disinfection: packaged plants, lagoons, industrial effluents Process water: chemical and pharmaceutical manufacture, food (washdown, canning, bleaching, taste and odor control) Cyanide, chromium removal: metal finishing wastes Recreation water: swimming pools, fountains, spray ponds

Operation Water flowing through the ejector venturi, creates a vacuum which opens the check valve in the ejector. The vacuum is carried through the vacuum line to the vacuum regulator where the pressure differential created causes the inlet valve at the vacuum regulator to open, initiating gas flow. A spring opposed diaphragm in the vacuum regulator, regulates the vacuum. The gas passes under vacuum through the flowmeter, the rate control valve, the vacuum line and to the ejector. Here the gas is thoroughly mixed with the motive water and applied as a solution. The system is completely under vacuum from the ejector to the vacuum regulator inlet safety valve. If the water supply to any ejector stops or vacuum is lost for any other reason, the spring loaded inlet valve immediately closes and isolates the gas supply. If the gas source is depleted, the unit seals to prevent moisture from being drawn back into the gas source. When more than one feed point is desired multiple flowmeters and ejectors can be supplied. Technical Data Quality Standard: ISO 9001 Capacities: Standard dual-rate indicating flowmeters are available with the following capacities: 4, 10, 25, 50, 100, 250 PPD (75, 200 g/h, 0.5, 1, 2, 5 kg/h) of chlorine gas. Flowmeter: The minimum feed capacity is 1/20th of the maximum capacity. Accuracy is within ±4% of maximum flowmeter capacity. Series 480 Vacuum Gas Feeder Model 4 8 C FEATURE A B C POSITION Position Feature Description A Maximum Capacity 1 100 PPD (2 kg/h) 2 250 PPD (5 kg/h) B Gas Handled C C Vacuum Regulator Mounting 1 Cylinder or manifold mounted with rate valve 2 Container mounted with drip leg and rate valve 3 Cylinder or manifold mounted with remote meter(s) and rate valve 4 Container mounted with drip leg with remote meter(s) and rate valve

Automatic Switchover For uninterrupted gas feeding on a round-the-clock basis, an automatic switchover system is required. Each system consists of two vacuum regulators, one vacuum type automatic switchover module, one ejector and one remote meter panel. An automatic switchover module allows gas to flow under vacuum from the regulator in service through the switchover module to the remote meter panel and the ejector, until that source is depleted. The vacuum sealing valve on the regulator then closes and the vacuum level in the system increases, initiating the spring-loaded toggle assembly in the switchover module. (See figure below) The open valve on the depleted source closes while the valve on the standby source opens to permit gas flow. When a fresh gas supply replaces the depleted source it will automatically be placed in standby. The fresh supply will not be accessed until the in-service supply is exhausted. Chemical Induction Units De Nora Water Technologies CHLOR-A-VAC Series 1420 chemical induction units offer improved chlorination and dechlorination through the high-efficiency mixing of gaseous chemical with process water. This translates into operating and chemical cost savings. CHLOR-A-VAC units produce a vacuum when process water passes through water inlet ports and through a venturi. The high vacuum and recessed impeller create great turbulence to insure complete chemical mixing. A chemical induction unit in lieu of an ejector should be considered for the following applications: contact basins, headwater, return sludge processes, clarifier inlets, collection basins, equalization tanks and clear wells. (Refer to Bulletin 130.0001) Automatic Switchover Flow Diagram Diaphragm To Remote Flowmeter O-Ring Seat From Vacuum Regulator No. 1 Toggle Assembly From Vacuum Regulator No. 2

Cylinder Mounted Chlorinator Flow Diagram Lead Gasket Cylinder Valve Stem Vacuum Seal O-Ring Inlet Safety Valve To Vent Rate Valve Outlet Connection Cylinder Valve Packing Unit Yoke Clamp X X Inlet Filter Vent Valve Rate Indicator Vacuum Line Gas Regulating Diaphragm Assembly Ejector and Check Valve Assembly Water Supply to Ejector Ejector Discharge Liquid Cylinder OR Check Valve Vacuum Line Power Chlor-A-Vac Chemical Induction Unit Contact Tank

Brief Specification The chlorinator design shall be of the vacuum operated, solution feed type. The chlorinator shall be constructed of materials suitable for wet or dry gas service. All springs used in the vacuum regulator shall be of tantalum alloy. The rate valve and seat shall be solid silver. A diaphragm shall be provided for vacuum regulation. The rate of gas feed shall be set manually and shall remain constant until manually changed. The gas shall flow at sonic velocity is eliminating the need for a differential pressure regulator. The vacuum regulator shall mount directly on the container valve by means of a corrosion resistant yoke assembly. A spring-opposed inlet valve shall close tight upon loss of vacuum. Each vacuum regulator shall be equipped with a loss-of-gas indicator, and a gas flowmeter. A spring-loaded diaphragm actuated pressure relief valve integral to the vacuum regulator shall be provided to relieve gas pressure. The inlet capsule shall be a complete module, installed without the use of any tools. The vacuum producing device shall be an ejector with a spring-loaded check valve to prevent flooding of the vacuum regulator or a CHLOR-A-VAC chemical induction unit, Series 1420. An automatic switchover module shall be provided with automatic reset. The chlorinator shall be De Nora Water Technologies Capital Controls Series 480C. Warranty De Nora Water Technologies offers a limited three (3) year warranty on the Series 480 chlorinator and a limited lifetime warranty on the springs and Halar diaphragm. De Nora Water Technologies is ISO 9001 certified to provide quality and precision materials.

Option: VEGA - Vent Exhaust Gas Arrestor Refer to Product Bulletin 141.0001 Typical Arrangement For those instances where occasional operational venting cannot be tolerated, a VEGA can be used to eliminate any errant gas emissions. The VEGA will last for a year under normal operating condition.

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL info.dnwt@denora.com www.denora.com Copyright 2017 Industrie De Nora S.p.A. - All rights reserved. De Nora, ON circle, Our research - your future, electrochemistry at your service (and any other trademark name) are trademarks or registered trademarks of Industrie De Nora S.p.A. in Europe and/or other countries. Other trademarks used herein are the registered trademarks of their respective owners. The information contained herein is offered for use by technically qualified personnel at their discretion and risk without warranty of any kind. DNWT - Capital Controls Series 480-100.0001.20-04/2017