Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Similar documents
Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Forehead Infrared Thermometer

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Instructions. Consumer Info-Line

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

CLETEF-786. Infrared Thermometer Instruction Manual

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

Thermometer with Wired Sensor

No Touch Thermometer

Thermometer model 02059

Digital Cooking Thermometer models / 00282

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Kinsa Smart Ear ThermometerTM Instructions For Use

FEATURES AND SPECIFICATIONS

User Manual. 40 Tower Fan MODEL: WFTR40W

IMPORTANT SAFETY INFORMATION:

Digital Refrigerator/Freezer Thermometer model 00986

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Weather Station model 02001

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Towel Warmer. Luxurious warmth for towels, robes and blankets

Sound Soother 20 Soothing Sounds

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information TABLETOP & FLOOR STANDING WITH REMOTE CONTROL

Wireless Driveway and Intruder Alert

Digital Thermometer with Ice Alert and Clock

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Forehead Thermometer Instruction Manual

SOOTHING COOL MIST AROMA DIFFUSER

CHOKING HAZARD-Toy contains

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Instruction Manual and Warranty Information

USER MANUAL. Intelligent toilet Primus

100 Ft. LASER DISTANCE METER

9000P Wireless Alarm Owner s Manual

USER MANUAL OUTDOOR IR ILLUMINATOR

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Color-Changing LED Aromatherapy Diffuser

WIRELESS COLOR FORECAST STATION

CLEAN MIST SMART HUMIDIFIER. Instruction Manual and Warranty Information TABLETOP & FLOOR STANDING WITH REMOTE CONTROL & MOOD LIGHT

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Weather Forecaster models 75077/75107

CR85. Instruction Manual TONE

(Place Logo from Lab here)

WIRELESS COLOR WEATHER STATION

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

Hello Kitty Pancake Maker Item # APP Owner s Manual

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS

SUNRISE ALARM CLOCK. With Multicolor LED Lights HME040187N. Before using your Sunrise Alarm Clock, please read this manual.

Installer Guide smart connect

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

High Resolution Display WIRELESS COLOR WEATHER STATION

AmazonBasics 15-Sheet Cross-Cut Paper/ CD/ Credit Card Shredder. Customer Service ASIN: B01M0FMM70

Projection Alarm Clock

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

CONNEX Smart Thermostat CST R00

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Ultrasonic Aromatherapy Diffuser with Color Changing LED Lights Instruction Manual and Warranty Information - Read and Save These Instructions.

Ultra Quiet USE AND CARE MANUAL IMPORTANT!

Installer Guide smart connect

Universal Fan and Light Remote Control

Pour & Float Froggy TM

WINIX AIR PURIFIER. User Manual. Tower XQ

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

&Fan. Instruction Manual. ULTRASlimline Heater. Model: (with remote control) Voltage: 120V AC Frequency: 60 Hz Power: 1500 W

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

Personal Ultrasonic Humidifier. FALLH-01 series

REMOTE CONTROL MANUAL

Little Anne. Important Product Information

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

Twin Bell Digital Clock

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Enhance Your Assembly Experience. Intended Use...

Wireless Color Weather Station

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

DEHUMIDIFIER. User Manual 50BT, 70BT

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0002E READ AND SAVE THESE INSTRUCTIONS

WIRELESS COLOR FORECAST STATION

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Instruction Manual. AmazonBasics 24-Sheet Cross-Cut Paper Shredder ASIN# B00HFJWMV4. Customer Service

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Self-Setting Clock Radio

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Thermometer with Probe model 00891A

Transcription:

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Intended Use: A digital thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electric signal amplification, conditioning, and display unit. Safety Information: High, prolonged fever requires medical attention especially for young children. Please contact your physician. Do not allow children to take their temperatures unattended. Read the enclosed instructions carefully to ensure accurate temperature readings. Temperature readings are affected by many factors including exercise, drinking hot or cold beverages prior to taking a reading as well as technique. Do not allow children to walk or run during temperature taking. The probe could present a hazard. WARNING: Keep battery out of children s reach. Swallowing battery could be harmful. Battery should not be recharged or placed into extreme heat as it may explode. CAUTION: Do not take an axillary temperature through patient s clothing. Direct probe cover to skin contact is required. CAUTION: Biting the probe tip while taking a temperature may result in damage to the probe. CAUTION: Do not autoclave or immerse thermometer in water or any other liquid. The unit is not waterproof. Please note the cleaning procedures described in this manual. How to take temperature: It is recommended that for 15 minutes prior to use, to avoid eating or drinking, exercising, taking a shower or bath, or smoking. If the thermometer has been stored at a very low or very high temperature, allow the unit to adjust naturally to room temperature before using. Wait at least 1 minute between consecutive measurements for the unit to readjust to room temperature. Place a probe cover carefully over the tip (Figure 1). Select oral, underarm or rectal as your measurement site based on the individual requiring a temperature measurement. Figure 1 2

Operating the 2 second digital thermometer: For first use: Remove the protective case from probe tip and the LCD protective sticker. 1. Turn the unit on by pressing the Multi-Function button, a short beep will follow. Wait 2 seconds for the unit to get ready. During these 2 seconds the following sequence will be displayed on the LCD: A: All display icons will appear. B: The display will show last measurement. C: The hourglass will disappear and the display will show the scale and mode icons. This will indicate the thermometer is now ready for measurement. 2. Select your preferred measurement location (oral/ rectal/underarm) by using the Mode button. Oral Rectal Axillary 3. Place the probe tip at the desired location. The temperature reading will be displayed within 2 seconds. One long beep will indicate that the measurement is completed. If you want to take another measurement, turn off the thermometer and wait 1 minute between consecutive measurements to allow the unit to readjust to room temperature. Please Note: Oral use: (for children 4 years and older) 1. Do not drink hot or cold fluids, exercise or perform other activities that will raise or lower temperature readings when compared to your normal, average temperature. The mouth should remain closed and sit still to help ensure an accurate measurement. 2. Place the probe tip well under the tongue as indicated (Figure 2). Figure 2 3

3. Instruct children not to bite down on the probe. 4. The peak temperature should be reached in approximately 2 seconds. Opening the mouth or improper placement of the probe tip could result in a longer time for a reading. Rectal use: 1. Commonly used for babies, young children or when it is difficult to take an oral or underarm temperature. 2. After placing the probe cover on the thermometer, lubricate with a water-soluble jelly or petroleum jelly. 3. Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do not force the tip into the rectum if resistance is encountered. 4. Dispose of the used probe cover and wash the thermometer as recommended. 5. The peak temperature should be reached in approximately 2 seconds. Underarm (Axillary) use: 1. Wipe underarm with a dry towel. 2. Place probe tip in armpit and bring arm down against the body. 3. The probe should be pointing upward in the same direction as your body if possible. 4. The time required for an accurate underarm temperature may be 2 seconds or longer depending on placement of the probe and closure of the arm against the body. Dual Color Display: In case the device detects a high heat flow from the patient s body the LCD backlight color will turn red. Otherwise, the LCD backlight color will display a green light. The LCD backlight color is an additional alert to the displayed temperature. WARNING! A high temperature requires immediate medical attention. Turning The Unit Off: Turn the thermometer off by pressing the Multi-Function button. If you forget to turn it off, the thermometer will automatically turn off after 1 minute. 4

Operation of the F - C feature: (How to change the measuring scale) 1. With the thermometer OFF, press simultaneously on the Mode button and on the Multi-Function button until you see the scale alternate. 2. Release both buttons and wait 5 seconds. The correct scale and the mode icon will appear, indicating the unit is ready to measure. Troubleshooting and special indications: The thermometer has been designed to display feedback-warnings to ensure proper usage and accurate temperature measurement. In the event of a malfunction or incorrect temperature measurement, the following warnings will be displayed: Display: Flickering LO (unit will beep 7 times): Indication: The measured temperature is below 95 F (35 C): 1. Turn the unit OFF, wait 1 minute and then turn ON again. 2. Retake temperature using proper technique while ensuring normal room temperature (between 73 F - 77 F / 23 C - 25 C). 3. If unit still reads LO, this indicates that the patient has low body temperature. WARNING! A low body temperature requires immediate medical attention. Display: Flickering HI (unit will beep 7 times): Indication: The measured temperature is above 107.6 F (42 C): 1. Turn the unit OFF, wait 1 minute and then turn ON again. 2. Retake temperature using proper technique. 3. If unit still reads HI, this indicates that the patient has an extremelyhigh temperature. WARNING! A high temperature requires immediate medical attention. Display: Er 1 (unit will beep 5 times and power off automatically): Indication: The thermometer is too cold or too hot to operate: 1. Verify room temperature is within product range 60.8 F-104 F (16 C - 40 C). 2. Wait 1 minute, retake temperature using proper technique. 5

Display: Er 2 (unit will beep 5 times and power off automatically): Indication: Temperature did not register because of poor contact, patient movement or poor placement. 1. Turn the unit OFF, wait 1 minute, turn it ON again and retake temperature using proper technique. (See Operating Instructions.) page.) Display: Er 3 (unit will beep 5 times and power off automatically): Indication: Unit malfunctioned. 1. Do not use the thermometer contact Customer Service. (See last Display: Flickering battery (after displaying the last temperature measurement) Indication: Low battery. 1. The battery has enough remaining life for approximately 10 more measurements. It is recommended to replace the battery as soon as possible. Display: Battery icon is on (unit will beep 5 times and power off automatically) Indication: Drained battery. 1. The battery is drained - replace battery. (See below on Replacing Batteries.) Care and Maintenance: Wipe the tip and probe with an alcohol swab or a cotton swab moistened with 70% isopropyl alcohol before and after each use. After cleaning, wait at least 2 minutes before taking a measurement for the unit to readjust to room temperature. Use only a soft dry cloth to clean the body of the thermometer (if necessary). Never use an abrasive cleanser or submerge the thermometer in water or other liquids. Do not expose the thermometer to extreme temperatures, humidity, direct sunlight or shock. Store at room temperature. 6

Parts and Assembly Display Window Flexible Probe Tip Mode Button Battery Cover (reverse side) Multi-Function Button Installing and replacing the Batteries: The thermometer uses one 2032Li 3V Coin Battery. To install/replace, first switch OFF the device: 1. Remove the battery cover by sliding it up. 2. Press the latch holding the battery to remove it from the housing. 3. Firmly attach the battery to its place; make sure polarity is correct (positive (+) side up). 4. Slide the battery cover back into place. Make sure the latch is firmly closed. IMPORTANT: It is recommended you remove the battery from the thermometer when it will not be used for a long period of time. WARNING: Do not dispose of batteries in fire, recharge, put in backwards, disassemble, or mix with used or other battery types they may explode or leak and cause injury. Waste batteries should be disposed of in accordance with local or national environmental regulations. 7

Specifications Size: Weight: Display: Battery: Battery Life: Measurement Time: Measurement Range: Accuracy: Measurement Mode: Audible Alarm: Auto Turn Off: Memory Feature: Operation Environment: Storage Environment: Standards: 5 L x 3/4 W x 3/8 H (12.7cm L x 1.905cm W x.9525cm H) 0.4903 oz. (13.90 gr) including battery LCD, Liquid Crystal Display - 15.9*18.6mm 2032Li 3V Coin Battery Minimum 1000 full duty cycles over a 24 month period Oral 2* Seconds / Rectal 2 Seconds / Axillary 2 Seconds 95 F - 107.6 F (35 C - 42 C) +/- 0.1 C/0.2 F between 37 C - 39 C /98.6 F - 102.2 F Predictive measurement 1 beep at start-up. Continuous beep at measurement completion 60 seconds Stores last temperature taken 60.8 F - 104 F (16 C - 40 C) Humidity: 15-95% (noncondensing) -4 F - 122 F (-20 C - 50 C) Humidity: 15-95% (noncondensing) Complies with ASTM E1112-00(2011) standard requirements *2 second response time achieved in water bath test. 8

THE FCC WANTS YOU TO KNOW... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency engergy and, if not installed and used according to the instructions, may cause harmful intereference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or to television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: A) Reorient or relocate the receiving antenna B) Increase the separation between the equipment and receiver C) Connect the equipment to an outlet on a different circuit from the one the receiver is connected to D) Consult the dealer or an experienced radio/tv technician WARRANTY: This Thermometer is guaranteed for a period of 24 months from date of purchase. This warranty does not cover batteries, or damage resulting from improper handling or use. Specific legal rights stipulated in your state may guide this warranty. If you have a legitimate claim under this warranty, send item(s) postage paid to Service Center, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase, a brief note explaining the problem, and your return address. Grand Bond Electronics Ltd Room 2208 22/F CCT Telecom Bldg. 11-19 Wo Shing Street Fotan, New Territories, Shatin Hong Kong Medes Limited 5 Beaumont Gate Shenley Hill, Radlett Hertfordshire, WD7 7AR United Kingdom Read the instructions carefully before using this device. Type BF applied part Distributed by: ADC 55 Commerce Drive Hauppauge NY 11788 Made in China Inspected in the U.S.A. tel: 1-631-273-9600 toll free: 1-800-232-2670 fax: 1-631-273-9659 www.adctoday.com email: info@adctoday.com Protected by US patent #6,280,397 B1 and other pending patents IB p/n 93-417-00 rev 1 0086 Printed in China