Technical Application Guide

Similar documents
Philips OneSpace luminous ceiling

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

Technical Application Guide for PHILIPS LED Lamps

Think LED. Think Philips TradeLED

Technical application guide

Maestro 0 10 V Dimmer Sensor

IP65 High Bay Dual Sense Sensor

Technical application guide

IP65 High Bay Dual Sense Sensor

DIMMING 0-10V Continuous

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

AmpLight Lighting Management System

Tri-level Control Sensor

EasyAir office sensor advanced grouping SNS200

Wembley Park. Case study. Case Study

VESICA LINEAR SUSPENDED VES L

Philips Master LED MR16

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Infrared Wall Mount Occupancy Sensor

Philips OneSpace luminous ceiling

LED Multi-Level Options

Extended Range DUAL TEC Motion Sensor

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Detector switch - Dual Tech SCS

Occupancy Sensor Operation with Lighting Fixtures

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

LED HIGH BAY LINEAR ECO SERIES

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

SCS motion sensors Surface/wall mounting - PIR

Wireless Occupancy Sensor:

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

HIGH POWER LED RETROFIT MODULE

Wireless Wall-Mount Sensor

Philips MASTER LEDbulb ClearClassic MV DimTone

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Data sheet. Function description. Benefits

Smart Starter Bundle. Hub. Smart Motion Sensor. Smart Door/ Window Sensor

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

Installation Instructions

LPCMPIRM65 & LPCMPIRDSI65

Indoor Controls. SpaceWise SWZG2. Wireless technology

Apex MediTech ALC109 ALARM SYSTEM

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

EWP2WIRELESS MOTION DETECTOR

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Motion Detector User Guide

180 Degree Ceiling Mounted Occupancy Sensors

High fidelity sound made portable. Philips Fidelio wireless portable speaker

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Installation Instructions

, ,

Infrared Ceiling Mount Sensor

Pioneering Petroleum Canopy Lighting Since 1976

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Infrared Ceiling Mount Sensor

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Passive infrared ceiling sensor

Tri-level Control HF Sensor

DHL-LP-LED Low Profile LED Linear High/Low Bay

LPC3BSP65 & LPC3BDP65

FR-A180 FR-A360. Occupancy detector. Use

Sensors Explained AUTOMATION

Detector switch - Dual Tech

Wireless Plug Load Control

Integrated PIR detectors

Wireless High Bay Sensor (WHS100) Installation Instructions

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Wireless Wall-Mount Sensor

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

600 Watt Dimmer Install Guide

Installation Guide. Ceiling PIR Detector (311) Features and Connections

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Sensors. EasyAir. office sensor advanced grouping SNS200. Design-in Guide. Single, compact, cost-effective luminaire control

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Tri-level Control HF Sensor

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LED Control Solutions

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

UP 258E11 OPTISENS OFFICE

Installation Instructions

Motion Sensor. Specifications

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

ENERGY EFFICIENCY EXPERTS

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

From the Originator and Leader in Integrated Motion Sensor Controls

Transcription:

Lighting Control Wireless Occupancy Sensor, Wireless Multi Sensor Technical Application Guide Philips wireless occupancy sensor and multi sensor, which are Interact Ready, mean easy upgrade to a smart lighting system. Its 2.4GHz mesh networking technology enables reliable and secure communication towards the lights in your space. It triggers automatic responses to turn on, off or dim the lights according to occupancy detection and daylight variation. The result? Even more energy saving and enhanced flexibility in your space!

Product Features Occupancy Detection Passive Infrared (PIR) technology to detect occupancy accurately. Adjustable sensitivity. Minimum false trigger. 40 sqm Field-of-View at typical mounting height. Daylight Sensing High accuracy of ambient light measurement from 1-2000 LUX Closed loop daylight regulation Daylight fast report for calibration Installation Battery-powered, no mains wire required. Quick and easy mounting with tapes or screws. Walk test mode available for optimal detection. Indoor use only. Environment No Mercury. Low Carbon Footprint. Connectivity 2.4GHz mesh networking technology. Reliable and secure wireless communication, nominal range 15m. Easy commissioning. Control Functionality Automatic light control based on occupancy detection and daylight sensing. Adjustable sensor parameters for personalized lighting behaviors. Reliability Reliable operation between -5 C and +45 C ambient temperature. Battery lifetime above 8 years. Minimum maintenance. [1] IP42 (IEC standard 60529 [1]: As calculated in typical conference room application. Application Retail Industry Schools Hospitals Offices Parking Lots Warehouses Public Areas 2

Field-of-View Field-of-view (FOV) for motion detection is determined at typical height (h=2.5m) for major and minor motion with NEMA tests, respectively. Daylight FOV is for multi sensor only. Motion FOV Sensor h 3.6 m (11.81 ft) 5.4 m (17.72 ft) h = 2.5-4 m (8.20-13.12 ft) At h = 2.5 m (8.2 ft) Valid at +20 C 5.4 m (17.72 ft) 7.2 m (23.62 ft) Daylight FOV h = max. 4 m/13.12 ft min. 0.7 x h h 1.4 x h lux 1.4 x h Motion FOV can be reduced using the plastic shield around the lens. 3

Installation Instructions 1 2 Instructions + 1 AA 3.6V 2 3 Commission sensor to network, Green LED 2 x blinks Red LED 2 x blinks > 3 m (9.8 ft) Push once: re-enter commissioning mode 4 5 Only for multi sensor 1 FOV indicator 2 3 x 4 sec: daylight fast reporting mode 4

A walk test will help to determine the optimal location to place the sensor by quickly testing the occupancy detection coverage. It's ONLY possible after sensor has been commissioned. Walk test ( 1 ) Press once AFTER commissioning to enter/exit the mode. ( 2 ) Red LED on - motion Red LED off - no motion If needed, the sensitivity for motion detection can be adjusted with the dial at the back. Three sensitivity levels are available from Low, Medium to High (High as default). Sensitivity L: low M: medium H: high Performing factory reset will restore sensor to un-commissioned status. Sensor will be removed from current network (if any). Factory reset x 4 sec 2 x Red and Green LED blinks 5

LED indicator LED pattern Green LED blinks every 10s Green LED blinks every 2s Green LED flash 2 Red LED flash 2 Green and Red LEDs flash 2 Red LED flash 1 Green LED flash 6 Red LED flash 3 Ready for commissioning Commissioning in progress Commissioning successful Commissioning failure Successful factory reset Motion detected in walk test mode Occupancy detected Occupancy detected and battery low Dimensions 26.4 mm (1.04 in) 29.9 mm (1.18 in) ø 86.5 mm(1.04 in) ø 86.5 mm(1.04 in) Temperature Operating temperature Toperating min -5 C max +45 C Storage temperature Tstorage min -25 C max +65 C Technical Specs and Order Information Product Product Description Type Mounting FOV Battery RF Daylight number height at lifetime range level 10NC h=2.5m open-air 9290018190 OCC SENSOR IA CM WH Occupancy, ceiling mounted ( m ) ( sqm ) ( yr ) ( m ) ( lux ) <= 4 40 > 8 15 -- 9290018191 OCC-DL SENSOR IA CM WH Occupancy and daylight, ceiling mounted <= 4 40 > 8 15 1-2000 Approbation & Certificates Philips wireless occupancy sensor and multi sensor follow applicable legislation and standard. The product complies with UL, cul and CE. 6

Application Notes Product is battery operated. Use only the specified battery type (3.6V AA). Misuse of battery may cause risk of fire or damage the device. Designed for indoor use only. DO NOT use in applications with high levels of condensation. Reliable operation between -5 C to +45 C ambient temperature. Modifications to the product void the limited warranty. For warranty information, please see www.philips.com/warranties. You are required to read and understand the Quick Installation Guide and all warnings, cautions and other materials related to installation before commencing installation work. 2018 Philips Lighting All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. 05/2018 www.philips.com